Description | Shipped From Abroad
Model : PH-B120; PHI-B130; ION-B131
This Benchtop pH Meter with 5-Point Calibration is a laboratory instrument used for precise pH measurements. It offers high accuracy and stability, often used in research and quality control settings.
Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| In stock
The technical innovation of the iSED® fully-automated ESR analyzer consists of directly measuring the intensity of the red cell aggregation which is responsible for Erythrocyte Sedimentation Rate (ESR).
Delivery & Availability:
Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | Shipped From Abroad
Electrolyte Analyzer ERMA EL-120 is ideal for medium to high volume Laboratories and Hospitals . It offers reliable, automated samples handling and work flow offences . It also allows measurement of specific ions, accurately and precisely . This supports fast diagnosis of critically ill patients and reduces the risks of patient discomfort associated with repeated sampling Precise & Accurate Results Economical to use Large Touchscreen Display with Graphical User Interface.
Delivery & Availability:
Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | In stock
- Microprocessor control.
- Digital display setting and actual temperature.
- Over temperature alarm, PID self-tuning.
- Digital display running timer.
- Stainless steel interior.
- Electricity leakage protection.
- With glass inner door, With hidden door locks.
- Mechanical overheat protection, cut off the heating sources.
- Automatic alarm after operation.
- Suitable for constant temperature tests.
- Suitable for bacteria cultivation, breeding, ferment.
Delivery & Availability:
Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | In stock
The coagulometer, LabPad® INR, measures blood coagulation time thanks to a patented optical technology. This portable In-Vitro Diagnostics (IVD) device works with the Tsmart® INR single-use microcuvettes.
Delivery & Availability:
Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | In Stock
Twenty Five (25) Test Strip per Pack
Delivery & Availability:
Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. |
Content | Benchtop pH Meter Features:
Different
- PH-B120: Customize 15 function parameters
- PH-B130: Customize 18 function parameters
- ION-B131: Customize 15 function parameters
Same
- 7-inch TFT display, high-definition and intuitive
- 1 to 5 points calibration, automatic recognition of USA, NIST, DIN standard buffers
- Automatic temperature compensation
- Automatic calibration date, time and 1-point offset calibration
- Large storage capacity of up to 1000 entries
- Solution temperature coefficient, compensates for pure water measurements and converts readings up to 25°C.
- Automatic alarm for measurements above the set range
Benchtop pH Meter Specifications:
Model |
PH-B120 |
PHI-B130 |
ION-B131 |
pH |
Range |
-2.000-20.000pH |
-2.000-20.000pH |
_ |
Resolution |
0.001,0.01, selectable |
0.001,0.01, selectable |
_ |
Accuracy |
±0.002pH |
±0.002pH |
_ |
Calibration Points |
1 to 5 points |
1 to 5 points |
_ |
Ph Buffer Options |
USA, NIST, DIN, 5 custom buffers |
USA, NIST, DIN, 5 custom buffers |
_ |
ORP |
mV Range |
±2000.0mV |
±2000.0mV |
±2000.0mV |
Relative mV Range |
±2000.0mV |
±2000.0mV |
_ |
Resolution |
0.1mV |
0.1mV |
0.1mV |
Accuracy |
±0.2mV |
±0.2mV |
±0.2mV |
Calibration Points |
1 point |
1 point |
_ |
Ion |
Range |
_ |
0.001~30000 (depending on the range of ISE) |
0.001~30000 (depending on the range of ISE) |
Resolution |
_ |
0.001, 0.01, 0.1, 1 |
0.001, 0.01, 0.1, 1 |
Accuracy |
_ |
±0.5% F.S. (monovalent), ±1% F.S. (divalent)) |
±0.5% F.S. (monovalent), ±1% F.S. (divalent)) |
Measurement |
_ |
ppm, mg/L, mol/L, mmol/L |
ppm, mg/L, mol/L, mmol/L |
Units |
Calibration Points |
_ |
2 to 5 points (0.001, 0.01, 0.1, 1, 10, 100, 1000, 10000) |
2 to 5 points (0.001, 0.01, 0.1, 1, 10, 100, 1000, 10000) |
Measurement Methods |
_ |
Direct reading, known addition, known subtraction, sample addition, sample subtraction |
Direct reading, known addition, known subtraction, sample addition, sample subtraction |
Electrode Management |
_ |
1 to 3 electrodes |
1 to 3 electrodes |
Water Hardness |
Range |
_ |
0.05~200mmol/L, 0~1122°dH, 0~1404°e, 0~2000°fH, 0~8000mg/L (Ca2+) |
0.05~200mmol/L, 0~1122°dH, 0~1404°e, 0~2000°fH, 0~8000mg/L (Ca2+) |
Resolution |
_ |
0.001, 0.01, 0.1, 1 |
0.001,0.01,0.1,1 |
Accuracy |
_ |
±1% F.S. |
±1% F.S. |
Calibration Points |
_ |
2to 5points 0.01, 0.1, 1, 10, 100mmol/L) |
2to 5points 0.01, 0.1, 1, 10, 100mmol/L) |
Temperature |
Range |
0~105°C / 32~221°F |
0~105°C / 32~221°F |
0~105°C/32~221°F |
Resolution |
0.1°C/0.1°F |
0.1°C/0.1°F |
0.1°C/0.1°F |
Accuracy |
±05°C/0.9°F |
±05°C/0.9°F |
±05°C/0.9°F |
Offset Calibration |
1 point, reading ±10°C |
1 point, reading ±10°C |
1 point, reading ±10°C |
Other Specifications |
Temperature Compensation |
0~100°C, manual or automatic |
0~100°C, manual or automatic |
0~100°C, manual or automatic |
Solution Temperature Coefficient |
25°C |
25°C |
_ |
Stability Criteria |
Standard or high-accuracy |
Standard or high-accuracy |
Standard or high-accuracy |
Calibration Due Alarm |
1to 31 days or off |
1to 31 days or off |
1to 31 days or off |
Interval Readings |
10, 30, 60 seconds, 10, 30 minutes or off |
10, 30, 60 seconds, 10, 30 minutes or off |
10, 30, 60 seconds, 10, 30 minutes or off |
Password Protection |
4digits |
4digits |
4digits |
Memory |
1000 data sets |
1000 data sets |
1000 data sets |
Communication Interface |
USB |
USB |
USB |
Connector |
BNC, 3.5 mm jack socket |
BNC, 3.5 mm jack socket |
BNC, 3.5 mm jack socket |
Display |
7 inches TFT LCD |
7 inches TFT LCD |
7 inches TFT LCD |
Power Requirements |
DC12V power adapter |
DC12V power adapter |
DC12V power adapter |
Sizes (W×D×H)(mm) |
240×220×80 |
240×220×80 |
240×220×80 |
Shipping Size (W×D×H)(mm) |
300x250x200 |
300x250x200 |
300x250x200 |
N.W./G.W. (kg) |
1.7/2.5 |
1.7/2.5 |
1.7/2.5 |
| The technical innovation of the iSED® fully-automated ESR analyzer consists of directly measuring the intensity of the red cell aggregation which is responsible for Erythrocyte Sedimentation Rate (ESR). Unlike traditional ESR methodologies that measure the aggregation of the red blood cells indirectly, the iSED measures it directly and expresses the values in mm/hr.
Features:
-
-
100µL sample drawn directly from primary EDTA tube
-
Fully automated, walk-away operation
-
-
Positive patient identification via internal barcode reader
-
Compatible with pediatric tube
Technical Specifications:
Principle of Measure: |
Photometrical |
Results: |
“Printed mm/hr, Range from 1-130 mm/hr” |
Sample Requirements: |
500uL whole blood, collected in EDTA anti-coagulant tested 24 hours from venipuncture at room temperature or refrigerated. |
Tube Requirements: |
13 x 75 mm, pierceable capped tube |
Quality Control: |
Barcoded Seditrol® QC |
Barcode Reader: |
Internal |
Printer: |
Internal |
Interface Specifications: |
serial RS232 port for LIS connection |
Weight: |
14 kg |
Dimensions (H x W x D): |
36 x 27 x 34 (cm) /14.3 x 10.5 x13.4 (in) |
Voltage: |
100-240VAC |
Frequency Range: |
50-60 Hz |
Power: |
160W |
Click Here To Download Catalogue | Electrolyte Analyzer ERMA EL-120 is ideal for medium to high volume Laboratories and Hospitals . It offers reliable, automated samples handling and work flow offences . It also allows measurement of specific ions, accurately and precisely . This supports fast diagnosis of critically ill patients and reduces the risks of patient discomfort associated with repeated sampling Precise & Accurate Results Economical to use Large Touchscreen Display with Graphical User Interface.
Features:
- Parameters: Na+,K+,Cl-, iCa++ / Li
- It works on ISE principle
- Sample Type: Whole blood, Serum, Plasma, Urine
- Low reagent consumption
- Sample requirement is only 90ul
- 60 samples per hour
- Automatic two point calibration after 4hrs and one point calibration with each sample analysis
- Air bubble detection
- Track reagents consumption and provides alerts
- For low reagent volume
- Precision testing facility to get CV and SD
- Trilevel Quality Control with LJ plots of last 30days
- Low aspiration volume
- Fast sample processing
- Accurate and Precise results
Technical Specifications:
Parameters |
Na+, K+, Cl– /Ca++ |
Principle |
Ion Selective Electrode (ISE) |
Sample Type |
Analyses whole blood, serum, plasma and urine |
Sample Volume |
≤100 µL |
Analysis Time |
≤60 seconds |
Throughout |
≤60 samples per hour |
Data Link |
Serial (RS232) |
External Interface |
USB (Keyboard, Mouse) |
Operating Condition |
10° C to 35° C, Relative Humidity up to 85% |
Storage Condition |
Temp: 10° C to 40° C |
Relative Humidity |
up to 85% non- condensing |
Power Supply |
100 to 240 VAC ±10%, 50Hz |
Dimensions |
395 x 260 x 375 mm |
Weight |
7.5 kg |
| Features:
- Microprocessor control.
- Digital display setting and actual temperature.
- Over temperature alarm, PID self-tuning.
- Digital display running timer.
- Stainless steel interior.
- Electricity leakage protection.
- With glass inner door, With hidden door locks.
- Mechanical overheat protection, cut off the heating sources.
- Automatic alarm after operation.
- Suitable for constant temperature tests.
- Suitable for bacteria cultivation, breeding, ferment.
Technical Specification:
Model: IB-9025A
Working size: 250x250x250mm/9.84x9.84x9.84inch
Power: 150W
Temperature range: Room temperature+5~65℃
Temperature resolution: 0.1℃
Temperature fluctuation: ±0.5℃
Timer: 0-9999min
Voltage: 110V 60Hz / 220V 50Hz
Dimension: 380x370x580mm/14.96x14.57x22.83inch
Size: 52cm*46cm*75cm / 20.5in*18.2in*29.6in
Gross Weight:42kg / 93lb
Net Weight: 23kg / 51lb
Warranty: 1 year |
The coagulometer, LabPad® INR, measures blood coagulation time thanks to a patented optical technology. This portable In-Vitro Diagnostics (IVD) device works with the Tsmart® INR single-use microcuvettes.
- User-friendly: the LabPad® INR is designed to be easy to use especially thanks to its 3D-shaped microcuvette that only requires a small drop of blood from a fingertip. Thanks to the color screen, both measurement steps and browsing the list of results are easy to visualize.
- Quick and reliable: the reliability of INR results is obtained by quality controls that are performed automatically before each measurement. In less than one minute, you can see if you are in your therapeutic range.
- Connected: the result obtained after performing the test can be transferred to healthcare professionals in charge of your treatment monitoring. This result is complementary to the pie charts and trend reports directly displayed on the LabPad® INR to help you monitoring your treatment
| Twenty Five (25) Test Strip per Pack |
Reviews
There are no reviews yet.