Benchtop pH Meter, 5 Calibration Point

$0.00

Shipped From Abroad

Model : PH-B120; PHI-B130; ION-B131

This Benchtop pH Meter with 5-Point Calibration is a laboratory instrument used for precise pH measurements. It offers high accuracy and stability, often used in research and quality control settings.

Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
SF1033560130127-97
Brands:: Scitek

Description

Benchtop pH Meter Features:

Different

  1. PH-B120: Customize 15 function parameters
  2. PH-B130: Customize 18 function parameters
  3. ION-B131: Customize 15 function parameters

Same

  1. 7-inch TFT display, high-definition and intuitive
  2. 1 to 5 points calibration, automatic recognition of USA, NIST, DIN standard buffers
  3. Automatic temperature compensation
  4. Automatic calibration date, time and 1-point offset calibration
  5. Large storage capacity of up to 1000 entries
  6. Solution temperature coefficient, compensates for pure water measurements and converts readings up to 25°C.
  7. Automatic alarm for measurements above the set range

 

Benchtop pH Meter Specifications:

 

Model PH-B120 PHI-B130 ION-B131
pH Range -2.000-20.000pH -2.000-20.000pH _
Resolution 0.001,0.01, selectable 0.001,0.01, selectable _
Accuracy ±0.002pH ±0.002pH _
Calibration Points 1 to 5 points 1 to 5 points _
Ph Buffer Options USA, NIST, DIN, 5 custom buffers USA, NIST, DIN, 5 custom buffers _
ORP mV Range ±2000.0mV ±2000.0mV ±2000.0mV
Relative mV Range ±2000.0mV ±2000.0mV _
Resolution 0.1mV 0.1mV 0.1mV
Accuracy ±0.2mV ±0.2mV ±0.2mV
Calibration Points 1 point 1 point _
Ion Range _ 0.001~30000 (depending on the range of ISE) 0.001~30000 (depending on the range of ISE)
Resolution _ 0.001, 0.01, 0.1, 1 0.001, 0.01, 0.1, 1
Accuracy _ ±0.5% F.S. (monovalent), ±1% F.S. (divalent)) ±0.5% F.S. (monovalent), ±1% F.S. (divalent))
Measurement _ ppm, mg/L, mol/L, mmol/L ppm, mg/L, mol/L, mmol/L
Units
Calibration Points _ 2 to 5 points (0.001, 0.01, 0.1, 1, 10, 100, 1000, 10000) 2 to 5 points (0.001, 0.01, 0.1, 1, 10, 100, 1000, 10000)
Measurement Methods _ Direct reading, known addition, known subtraction, sample addition, sample subtraction Direct reading, known addition, known subtraction, sample addition, sample subtraction
Electrode Management _ 1 to 3 electrodes 1 to 3 electrodes
Water Hardness Range _ 0.05~200mmol/L, 0~1122°dH, 0~1404°e, 0~2000°fH, 0~8000mg/L (Ca2+) 0.05~200mmol/L, 0~1122°dH, 0~1404°e, 0~2000°fH, 0~8000mg/L (Ca2+)
Resolution _ 0.001, 0.01, 0.1, 1 0.001,0.01,0.1,1
Accuracy _ ±1% F.S. ±1% F.S.
Calibration Points _ 2to 5points 0.01, 0.1, 1, 10, 100mmol/L) 2to 5points 0.01, 0.1, 1, 10, 100mmol/L)
Temperature Range 0~105°C / 32~221°F 0~105°C / 32~221°F 0~105°C/32~221°F
Resolution 0.1°C/0.1°F 0.1°C/0.1°F 0.1°C/0.1°F
Accuracy ±05°C/0.9°F ±05°C/0.9°F ±05°C/0.9°F
Offset Calibration 1 point, reading ±10°C 1 point, reading ±10°C 1 point, reading ±10°C
Other Specifications Temperature Compensation 0~100°C, manual or automatic 0~100°C, manual or automatic 0~100°C, manual or automatic
Solution Temperature Coefficient 25°C 25°C _
Stability Criteria Standard or high-accuracy Standard or high-accuracy Standard or high-accuracy
Calibration Due Alarm 1to 31 days or off 1to 31 days or off 1to 31 days or off
Interval Readings 10, 30, 60 seconds, 10, 30 minutes or off 10, 30, 60 seconds, 10, 30 minutes or off 10, 30, 60 seconds, 10, 30 minutes or off
Password Protection 4digits 4digits 4digits
Memory 1000 data sets 1000 data sets 1000 data sets
Communication Interface USB USB USB
Connector BNC, 3.5 mm jack socket BNC, 3.5 mm jack socket BNC, 3.5 mm jack socket
Display 7 inches TFT LCD 7 inches TFT LCD 7 inches TFT LCD
Power Requirements DC12V power adapter DC12V power adapter DC12V power adapter
Sizes (W×D×H)(mm) 240×220×80 240×220×80 240×220×80
Shipping Size (W×D×H)(mm) 300x250x200 300x250x200 300x250x200
N.W./G.W. (kg) 1.7/2.5 1.7/2.5 1.7/2.5

Reviews

There are no reviews yet.

Be the first to review “Benchtop pH Meter, 5 Calibration Point”

Your email address will not be published. Required fields are marked *

Quick Comparison

Benchtop pH Meter, 5 Calibration Point removeTest Strip for ApexBio HemoSmart Gold Hemoglobin Meter removeAlcohol Pad Per Pack removeAvalun LabPad Device removeErma B-111 Bilirubin Meter removeAvalun 48 INR Microcuvette remove
NameBenchtop pH Meter, 5 Calibration Point removeTest Strip for ApexBio HemoSmart Gold Hemoglobin Meter removeAlcohol Pad Per Pack removeAvalun LabPad Device removeErma B-111 Bilirubin Meter removeAvalun 48 INR Microcuvette remove
ImageAvalun Labpad machineAvalun 48 INR Microcuvette
SKUSF1033560130127-97SF1033560084-30SF1033560084-64SF1033560084-65SF1033560084-6SF1033560084-74
Rating
Price

$0.00

$9.50

$4.25

$0.00

$715.00

$0.00

Stock

Out of stock

AvailabilityOut of stock
Add to cart

DescriptionShipped From Abroad Model : PH-B120; PHI-B130; ION-B131 This Benchtop pH Meter with 5-Point Calibration is a laboratory instrument used for precise pH measurements. It offers high accuracy and stability, often used in research and quality control settings.
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In Stock Twenty Five (25) Test Strip per Pack

Delivery & Availability:

Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock Alcohol Pad (70% Isopropyl Alcohol Pre Pad, Alcohol Cleansing Swab). Clean the required area. Discard after single use. Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.In stock The coagulometer, LabPad® INR, measures blood coagulation time thanks to a patented optical technology. This portable In-Vitro Diagnostics (IVD) device works with the Tsmart® INR single-use microcuvettes. Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.Shipped From Aboard  The advanced B111 Bilirubinmeter provides fast, accurate results for Total bilirubin level in neonates with only 40μl serum or plasma sample. It determines total bilirubin by dual wavelength photometric analysis. Suited for pediatric setups, small workload labs & hospitals because of its compact and portable design. Advanced, benchtop and precise instrument for measuring Total Bilirubin.

Delivery & Availability:

Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Out stock LabPad®’s versatility comes especially from its Tsmart® single-use microcuvette, which contains a lyophilized reagent specific to each test. The Tsmart® microcuvette is the fruit of numerous innovations that have led to many benefits for users. Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Content
Benchtop pH Meter Features:
Different
  1. PH-B120: Customize 15 function parameters
  2. PH-B130: Customize 18 function parameters
  3. ION-B131: Customize 15 function parameters
Same
  1. 7-inch TFT display, high-definition and intuitive
  2. 1 to 5 points calibration, automatic recognition of USA, NIST, DIN standard buffers
  3. Automatic temperature compensation
  4. Automatic calibration date, time and 1-point offset calibration
  5. Large storage capacity of up to 1000 entries
  6. Solution temperature coefficient, compensates for pure water measurements and converts readings up to 25°C.
  7. Automatic alarm for measurements above the set range
 
Benchtop pH Meter Specifications:
 
Model PH-B120 PHI-B130 ION-B131
pH Range -2.000-20.000pH -2.000-20.000pH _
Resolution 0.001,0.01, selectable 0.001,0.01, selectable _
Accuracy ±0.002pH ±0.002pH _
Calibration Points 1 to 5 points 1 to 5 points _
Ph Buffer Options USA, NIST, DIN, 5 custom buffers USA, NIST, DIN, 5 custom buffers _
ORP mV Range ±2000.0mV ±2000.0mV ±2000.0mV
Relative mV Range ±2000.0mV ±2000.0mV _
Resolution 0.1mV 0.1mV 0.1mV
Accuracy ±0.2mV ±0.2mV ±0.2mV
Calibration Points 1 point 1 point _
Ion Range _ 0.001~30000 (depending on the range of ISE) 0.001~30000 (depending on the range of ISE)
Resolution _ 0.001, 0.01, 0.1, 1 0.001, 0.01, 0.1, 1
Accuracy _ ±0.5% F.S. (monovalent), ±1% F.S. (divalent)) ±0.5% F.S. (monovalent), ±1% F.S. (divalent))
Measurement _ ppm, mg/L, mol/L, mmol/L ppm, mg/L, mol/L, mmol/L
Units
Calibration Points _ 2 to 5 points (0.001, 0.01, 0.1, 1, 10, 100, 1000, 10000) 2 to 5 points (0.001, 0.01, 0.1, 1, 10, 100, 1000, 10000)
Measurement Methods _ Direct reading, known addition, known subtraction, sample addition, sample subtraction Direct reading, known addition, known subtraction, sample addition, sample subtraction
Electrode Management _ 1 to 3 electrodes 1 to 3 electrodes
Water Hardness Range _ 0.05~200mmol/L, 0~1122°dH, 0~1404°e, 0~2000°fH, 0~8000mg/L (Ca2+) 0.05~200mmol/L, 0~1122°dH, 0~1404°e, 0~2000°fH, 0~8000mg/L (Ca2+)
Resolution _ 0.001, 0.01, 0.1, 1 0.001,0.01,0.1,1
Accuracy _ ±1% F.S. ±1% F.S.
Calibration Points _ 2to 5points 0.01, 0.1, 1, 10, 100mmol/L) 2to 5points 0.01, 0.1, 1, 10, 100mmol/L)
Temperature Range 0~105°C / 32~221°F 0~105°C / 32~221°F 0~105°C/32~221°F
Resolution 0.1°C/0.1°F 0.1°C/0.1°F 0.1°C/0.1°F
Accuracy ±05°C/0.9°F ±05°C/0.9°F ±05°C/0.9°F
Offset Calibration 1 point, reading ±10°C 1 point, reading ±10°C 1 point, reading ±10°C
Other Specifications Temperature Compensation 0~100°C, manual or automatic 0~100°C, manual or automatic 0~100°C, manual or automatic
Solution Temperature Coefficient 25°C 25°C _
Stability Criteria Standard or high-accuracy Standard or high-accuracy Standard or high-accuracy
Calibration Due Alarm 1to 31 days or off 1to 31 days or off 1to 31 days or off
Interval Readings 10, 30, 60 seconds, 10, 30 minutes or off 10, 30, 60 seconds, 10, 30 minutes or off 10, 30, 60 seconds, 10, 30 minutes or off
Password Protection 4digits 4digits 4digits
Memory 1000 data sets 1000 data sets 1000 data sets
Communication Interface USB USB USB
Connector BNC, 3.5 mm jack socket BNC, 3.5 mm jack socket BNC, 3.5 mm jack socket
Display 7 inches TFT LCD 7 inches TFT LCD 7 inches TFT LCD
Power Requirements DC12V power adapter DC12V power adapter DC12V power adapter
Sizes (W×D×H)(mm) 240×220×80 240×220×80 240×220×80
Shipping Size (W×D×H)(mm) 300x250x200 300x250x200 300x250x200
N.W./G.W. (kg) 1.7/2.5 1.7/2.5 1.7/2.5
Twenty Five (25) Test Strip per PackAlcohol Pad (70% Isopropyl Alcohol Pre Pad, Alcohol Cleansing Swab). Clean the required area. Discard after single use. Size and packing of Medical Alcohol pad:
  • Pad Size: Unfolded: 30 x 60 mm (other size can be request ).
  • Folded: 30x30 mm, 30 x 35mm,can be 2ply or 4ply ( other size, ply can be request ).
  • Aluminum Package: 60 x 50 mm , 50 x 50mm approximate ( other size can be request ).
  • Packing: 100/200 pcs per inner box, 50/ 100 boxes per carton(packing can be request).
Use of Medical Alcohol pad:
  • For cleaning prior to injection or to disinfect the hurted skin for family and medical treatment organization use.
  • For preparation and immediate disinfection of skin, wound area orr Instrument and utensil.
Notice of Medical Alcohol pad:
  • Not for eyes;
  • keep out of reach of children;
  • For external use only;
  • please stop using if you feel allergic or amyctic
Materials - Non-Woven Fabric
Trademark - OEM/ODM
Specification - CE&ISO13485
   
The coagulometer, LabPad® INR, measures blood coagulation time thanks to a patented optical technology. This portable In-Vitro Diagnostics (IVD) device works with the Tsmart® INR single-use microcuvettes.
  • User-friendly: the LabPad® INR is designed to be easy to use especially thanks to its 3D-shaped microcuvette that only requires a small drop of blood from a fingertip. Thanks to the color screen, both measurement steps and browsing the list of results are easy to visualize.
  • Quick and reliable: the reliability of INR results is obtained by quality controls that are performed automatically before each measurement. In less than one minute, you can see if you are in your therapeutic range.
  • Connected: the result obtained after performing the test can be transferred to healthcare professionals in charge of your treatment monitoring. This result is complementary to the pie charts and trend reports directly displayed on the LabPad® INR to help you monitoring your treatment
 
Click Here To Download Catalogue
   
The advanced B111 Bilirubinmeter provides fast, accurate results for Total bilirubin level in neonates with only 40μl serum or plasma sample. It determines total bilirubin by dual wavelength photometric analysis. Suited for pediatric setups, small workload labs & hospitals because of its compact and portable design. Advanced, benchtop and precise instrument for measuring Total Bilirubin. Feature
  • Auto zero function: Manual blanking not required
  • Dual wavelength measurement system:
  • 2 wave lengths 455nm and 575nm
  • Plays major role to remove the interference caused due to Hemolysis & turbidity of sample
  • LED Light source:
  • LED does not require replacement as it lasts longer
  • As compared to Lamp, LED are more suitable as there is no intensity fluctuations
  • No warm up time required.
  • Flexible unit selection:
  • Two units either mg/dl or umol/L are selectable, ease of reporting
  • Compact slot for Capillary:
  • Accuracy of results are directly related to proper alignment of Capillary
  • B-111 has the easiest mode to ensure precise values
  • Data transfer:
  • External device can be connected to instrument through RS232 por
  • USB port
Technical Specification
  • Light source - LED
  • Wavelength - 455nm and 575nm
  • Net weight - 1kg
  • Measuring range - 0-30 mg/dl , 510 umol/L
  • Display - 16×2 LCD module with backlight
  • Auto calibration - Yes
  • Sample type - Serum or plasma
  • Sample volume - 40-80μL
  • Test time - <5sec
  • Units - mg/dl or umol/L
  • Dimensions - 150 (W) × 115 (H) × 190 (D) mm
  • Interface - RS232
  • Reading cuvette - Heparinized micro capillary holder
  • Storage temperature - 15-40°c
  • Power supply - DC 9V(DC adapter)
  • Power consumption - <2W
LabPad®’s versatility comes especially from its Tsmart® single-use microcuvette, which contains a lyophilized reagent specific to each test. The Tsmart® microcuvette is the fruit of numerous innovations that have led to many benefits for users.
Features:
  • Fully automated "plug-and-play"   behavior
  • Reduced blood volume (only 3µL)
  • A large space for blood drop-off
  • Fills up quickly, using just capillarity
  • Easy handling, thanks to its 3D shape
  • Optimized preservation in individual pouches, in boxes of 12, 24, or 48 units
WeightN/AN/AN/AN/AN/AN/A
DimensionsN/AN/AN/AN/AN/AN/A
Additional information
Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.