Biological Safety Cabinet Class II A2
$0.00
Shipped From Abroad
Class II A2 biological safety cabinet is biological safety isolation equipment used in biological safety labs, It can prevent harmful or unknown biological particulate aerosol from escaping during operation, it’s suitable for working with microbiological research in the absence of volatile or toxic chemicals and radionuclide.
- Protection: Operator, samples and the environment.
- Airflow System: 70% air recirculation, 30% air exhaust
- Work area: Negative pressure
- Standard with ULPA filter
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Description
Class II Biological Safety Cabinet Features:
- UV sterilization function and timing function can be set by appointment.
- Automatic air speed adjustable.
- With memory function in case of power-failure.
- Audio and visual alarm (Abnormal airflow velocity, filter failure, UV lamp failure, Front window at unsafe height).
- Interlock function: UV lamp and front window; UV lamp and blower, LED lamp; Blower and front window.
Advantages
1.Standard with ULPA filter.
2.UV sterilization function and timing function can be set by appointment.
3.Automatic air speed adjustable.
4.With memory function in case of power-failure.
5.Audio and visual alarm (Abnormal airflow velocity, filter failure, UV lamp failure, Front window at unsafe height).
6.Interlock function: UV lamp and front window; UV lamp and blower, LED lamp; blower and front window.
Biological Safety Cabinet Specifications:
Quick Comparison
Settings | Biological Safety Cabinet Class II A2 remove | Discover 5 Panel Cup with Adulterants Per Pack remove | Erma B-111 Bilirubin Meter remove | Skyla Hi POC Clinical Chemistry Analyzer remove | Avalun LabPad Device remove | Automatic Pipette remove |
---|---|---|---|---|---|---|
Name | Biological Safety Cabinet Class II A2 remove | Discover 5 Panel Cup with Adulterants Per Pack remove | Erma B-111 Bilirubin Meter remove | Skyla Hi POC Clinical Chemistry Analyzer remove | Avalun LabPad Device remove | Automatic Pipette remove |
Image | ![]() | ![]() | ![]() | ![]() | ![]() | ![]() |
SKU | SF1033560130127-36 | SF1033560084-23 | SF1033560084-6 | SF1033560060-2 | SF1033560084-65 | SF1033560084-130 |
Rating | ||||||
Price |
|
| $715.00 |
|
|
|
Stock | ||||||
Availability | ||||||
Add to cart | ||||||
Description | Shipped From Abroad
Class II A2 biological safety cabinet is biological safety isolation equipment used in biological safety labs, It can prevent harmful or unknown biological particulate aerosol from escaping during operation, it's suitable for working with microbiological research in the absence of volatile or toxic chemicals and radionuclide.
Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| In stock
The Discover Cup is an all-in-one drug of abuse test cup. The strips are self-contained and the entire cup is tamper resistant.
Delivery & Availability:
| Shipped From Aboard
The advanced B111 Bilirubinmeter provides fast, accurate results for Total bilirubin level in neonates with only 40μl serum or plasma sample. It determines total bilirubin by dual wavelength photometric analysis. Suited for pediatric setups, small workload labs & hospitals because of its compact and portable design. Advanced, benchtop and precise instrument for measuring Total Bilirubin.
Delivery & Availability: Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | Shipped from Abroad The skyla Hi POC Clinical Chemistry Analyzer provides clinical testing laboratories of medical facilities and clinics with an in-vitro clinical chemistry diagnostic tool that is compact, portable, and reports rapid results.The use of skyla Hi in the management of diabetes enables better access to testing and rapid clinical decision making, discussion,and implementation of optimized treatment. Delivery & Availability: Typically 14 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | In stock The coagulometer, LabPad® INR, measures blood coagulation time thanks to a patented optical technology. This portable In-Vitro Diagnostics (IVD) device works with the Tsmart® INR single-use microcuvettes. Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | In stock
|
Content | Class II Biological Safety Cabinet Features:
Advantages1.Standard with ULPA filter. 2.UV sterilization function and timing function can be set by appointment. 3.Automatic air speed adjustable. 4.With memory function in case of power-failure. 5.Audio and visual alarm (Abnormal airflow velocity, filter failure, UV lamp failure, Front window at unsafe height). 6.Interlock function: UV lamp and front window; UV lamp and blower, LED lamp; blower and front window.Biological Safety Cabinet Specifications: |
All-in-One Design
| The advanced B111 Bilirubinmeter provides fast, accurate results for Total bilirubin level in neonates with only 40μl serum or plasma sample. It determines total bilirubin by dual wavelength photometric
analysis. Suited for pediatric setups, small workload labs & hospitals because of its compact and portable design. Advanced, benchtop and precise instrument for measuring Total Bilirubin.
Feature
| skyla Hi Analyzer enables better access to testing and rapid clinical decision making, discussion, and implementation of optimized treatment. To get the result, only prepare <1 μl fingertips blood or venous blood (depends on test item) without pretreatment with easy steps and then read the result after 6 mins. The device allows two specimens be tested in one run and provides fully automatic procedures from checking the validity of cartridge to printing the results.
Reagent Kit
Main SpecificationPrinciple
Turbidimetric Method / Biochemistry
Device
Testing Time
5~20 minutes (depends on test items)
Display and Interface
5″ TFT color touch screen LCD
Memory Capacity
50,000 test results
Dimension of Analyzer
270 x 188 x 148 mm
Weight of Analyzer
1.7 kg
Dimension of Printer Module
134 x 100 x 82.7 mm
Weight of Printer Module
0.37 kg
Power Supply
100~240 volts AC, 50-60Hz
Data Transmission
USB 2.0*4 / USB 3.0*1 / RS232*1 / RJ45*1 / Wi-Fi (optional)
Reagent and SamplesSamples
Fingertips blood or venous blood
Samples Volume
0.8 ~ 30 μL (depends on test item)
Storage Temperature (Reagent)
2 ~ 8˚C
HumidityRelative humidity < 95% (Non-condensing)
| The coagulometer, LabPad® INR, measures blood coagulation time thanks to a patented optical technology. This portable In-Vitro Diagnostics (IVD) device works with the Tsmart® INR single-use microcuvettes.
Click Here To Download Catalogue | This Automatic Pipette will help you get your lab up and running in no time—at a great price!
Features:
|
Weight | N/A | N/A | N/A | N/A | N/A | N/A |
Dimensions | N/A | N/A | N/A | N/A | N/A | N/A |
Additional information |
Reviews
There are no reviews yet.