BLX-9 Intraoral Imaging High Frequency X-ray Machine
$0.00
Shipped From Abroad
The BLX-9 Intraoral Imaging High-Frequency X-ray Machine provides portable, high-quality dental imaging with adjustable exposure times and low radiation leakage. Its compact design and compatibility with various imaging mediums make it an ideal choice for modern dental practices seeking efficiency and safety in radiography.
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Description
The BLX-9 Intraoral Imaging High-Frequency X-ray Machine is designed for dental professionals seeking a portable and efficient radiography solution. Operating at a high frequency of 30 kHz, it ensures clear and stable images. The device features adjustable exposure times ranging from 0.5 to 9 seconds, catering to various diagnostic needs. Its compact design, weighing approximately 6.5 kg, allows for easy transportation and use in multiple clinical settings. With a tube voltage of 70 kV and a tube current of 0.2 mA, it delivers precise imaging while maintaining radiation leakage below 20 μGy/h, adhering to international safety standards. The BLX-9 is compatible with both traditional dental films and digital sensors, making it a versatile addition to any dental practice.
Key Features
-
High-Frequency Operation: Operates at 30 kHz, ensuring stable and clear imaging results.
-
Adjustable Exposure Time: Exposure time ranges from 0.5 to 9 seconds, allowing flexibility based on diagnostic requirements.
-
Toshiba 0.3mm Micro-Focus Tube: Delivers clearer and more detailed images, crucial for precise diagnostics.
-
Radiation Protection: The tube head is equipped with excellent radiation-shield protection, ensuring safety for both operator and patient.
-
Portable Design: Compact in volume and light in weight (approximately 6.5 kg), convenient for carrying and operation
-
Compatibility: Compatible with both traditional dental films and digital sensors, facilitating integration into different imaging workflows.
Specifications
Specification | Details |
---|---|
Model | BLX-9 |
Tube Voltage | 70 kV |
Tube Current | 0.2 mA |
Frequency | 30 kHz |
Exposure Time | 0.5–9 seconds |
Focus Spot Size | 0.3 mm (Toshiba tube) |
Radiation Leakage | <20 μGy/h |
Power Supply | 24V DC, 8000 mAh |
Weight | Approximately 6.5 kg |
Dimensions | 28 × 20 × 8 cm (Mainframe) |
Focal Distance | ≥20 cm |
Operating Temperature | 5–40ºC |
Humidity | <80% RH |
Quick Comparison
Settings | BLX-9 Intraoral Imaging High Frequency X-ray Machine remove | Genoray Papaya Plus Panoramic Dental X-Ray remove | Manual Suction Machine (Pedal) remove | Ultrasonic scaler remove | Wall Mounted Dental X-Ray Unit remove | Intra Oral Camera remove | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Name | BLX-9 Intraoral Imaging High Frequency X-ray Machine remove | Genoray Papaya Plus Panoramic Dental X-Ray remove | Manual Suction Machine (Pedal) remove | Ultrasonic scaler remove | Wall Mounted Dental X-Ray Unit remove | Intra Oral Camera remove | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Image | ![]() | ![]() | ![]() | ![]() | ![]() | ![]() | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
SKU | SF10335601104 | SF1033560084-171 | SF10335601306 | SF103356013068 | SF103356013073 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Rating | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Price |
|
| $40.00 | $330.00 | $1,023.00 | $198.00 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Stock | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Availability | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Add to cart | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Description | Shipped From Abroad
The BLX-9 Intraoral Imaging High-Frequency X-ray Machine provides portable, high-quality dental imaging with adjustable exposure times and low radiation leakage. Its compact design and compatibility with various imaging mediums make it an ideal choice for modern dental practices seeking efficiency and safety in radiography. Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| Shipped From Abroad
The HQ-760DY Dry Imager is a thermo-graphic film processor designed for digital radiography imaging. It is the one and only domestically engineered medical dry thermal imager
Delivery & Availability:
Typically 14-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| In stock
| Shipped From Abroad
VRN-A8 Wireless control scaler with auto-water supply
Function: Scaling, Perio, Endo irrigation
Water supply: Auto-water supply
Wireless control foot switch
Handpiece: Metal Detachable handpiece
Color: White
Input: AC100~240V 47~63Hz
Main unit input: DC30V 1.5A
Foot switch battery: 1.5V× 2
Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| Shipped From Abroad
Technical Features:
1. Clear picture, high efficiency, international advanced technology
2. Low radiation: the radiation leakage is only 1% of the state regulations
3. Microcomputer control system, exposure parameters will be quickly and accurately formed at one button push.
4. Easy operation
Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| Shipped From Abroad
The functions include capture and storage. It can be controlled through VGA monitors or computers. It’s convenient for dentists and improving their working efficiency.
Delivery & Availability:
Typically, 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Content | The BLX-9 Intraoral Imaging High-Frequency X-ray Machine is designed for dental professionals seeking a portable and efficient radiography solution. Operating at a high frequency of 30 kHz, it ensures clear and stable images. The device features adjustable exposure times ranging from 0.5 to 9 seconds, catering to various diagnostic needs. Its compact design, weighing approximately 6.5 kg, allows for easy transportation and use in multiple clinical settings. With a tube voltage of 70 kV and a tube current of 0.2 mA, it delivers precise imaging while maintaining radiation leakage below 20 μGy/h, adhering to international safety standards. The BLX-9 is compatible with both traditional dental films and digital sensors, making it a versatile addition to any dental practice. Key Features
Specifications
| Features Panoramic Imaging - By choosing a sensor, which improves the image quality while keeping radiation exposure to a minimum, Genoray has shown that it puts patient’s safety first. Cephalometric Imaging - When compared to the standard scanning method, PAPAYA PLUS has the shortest scan time out there - Among patient discomfort, image's swing, and distortion, they are reduced along with the short scan time. Tomography Imaging (Optional) PAPAYA PLUS added Tomography function and without hardware upgrade and considering of manufacturing of Tomography function; in addition to S/W, PAPAYA provides Tomography image. High Resolution Cephalometric Technology It is enough only 4 second for scanning cephalo image on fast mode. This reduces motion artifacts. The Different Detector Types High-Definition images distinguish themselves from the old indirect conversion type of a CCD sensor. This should be the only way you view images User Friendly Face to face positioning / Fit each individual’s jaw shape. / Voice support system / Hand switch / Emergency switch / Wheelchair accessible Multi-Focus Function Multi-focus function ables to overcome operator's mistake from patient's faulty positioning and re-exposuring X-ray. By reconstructing image with software way, the panoramic images layer can be corrected by multi-focus function. Exposure Programs Lateral, AP, PA, Water’s view, Submento vertex, and carpus.Click Here To Download Catalogue | Pedal Suction offered by us is primarily used in hospitals of all levels for suction of phlegm, blood and other thick liquid during surgical operations and induced abortions. Due to its compact size, lightweight and trouble-free operation and it particularly fits for being extensively used in rural clinics, no power area, homes, remote areas, and other emergency occasions.
Features:
|
Ultrasonic scaler Features/Specification:
VRN-A8 Wireless control scaler with auto-water supply
Function: Scaling, Perio, Endo irrigation
Water supply: Auto-water supply
Wireless control foot switch
Handpiece: Metal Detachable handpiece
Color: White
Input: AC100~240V 47~63Hz
Main unit input: DC30V 1.5A
Foot switch battery: 1.5V× 2
Receiving sensitivity: -114Db
Power: 30VA~48VA
Vibration frequency of the tip: 25~31KHz Primary vibration excursion of the tip: ≤ 100μm
Output half-excursion: < 2N
Ultrasonic output power: 3W~20W
Water pressure: 0.01MPa~0.05MPa
Weight of main unit: 1.10kg
Weight of adapter: 0.25kg
| Technical Features: 1. Clear picture, high efficiency, international advanced technology 2. Low radiation: the radiation leakage is only 1% of the state regulations 3. Microcomputer control system, exposure parameters will be quickly and accurately formed at one button push. 4. Easy operation 5. Pictures could be rinsed in bright room, imaging in a minute provide much convenience to dentists. 6. Seat is free to lift up and down 7. Dental digital sensors could fit this X-ray equipment 8. Do not occupy any ground, save space for users 9. Rotating arm is stable, reliable, durable and easy to use 10. low pressure alarm, high pressure alarm, automatic failure detection alarm Specifications: Voltage: 220V/50Hz±10% 50/60 Hz Socket: Internalthree-pin/European three-pin Max power: 900VA Rated current: 4A Fuse: 6.3A Radiation focus: 0.8mm Tube-head voltage: 70kV±10% Anodal current: 7mA±15% Anodal angle: 19° Loading circle: 1/60 Half-value layer: 70kV 1.6mmAl Proper filter: ≥2.1mmAl Radiation leakage: 1m<0.007mGy/h | Intra Oral Camera Features
The functions include capture and storage. It can be controlled through VGA monitors or computers. It’s convenient for dentists and improving their working efficiency.
Standard Fittings:
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Weight | N/A | N/A | N/A | N/A | N/A | N/A | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Dimensions | N/A | N/A | N/A | N/A | N/A | N/A | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Additional information |
Reviews
There are no reviews yet.