Description | Shipped From Abroad
SONOST 3000 is a portable stand-alone quantitative ultrasound (QUS) bone densitometer with an embedded PC, colorful touch screen and a built-in thermal printer.
Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| Shipped from Abroad
OPENMARK 5000 is 0.51T MRI. It's approved by FDA and has CE mark. It adopts two-pillar magnet design with 280 degree openness and equipped with powerful
RF and gradient system, together with advanced imaging technology, making it as a high-end system which is comparable to high-field MRI.
Delivery & Availability:
Typically 90 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | Shipped from Abroad
The ANATOM 64 CT scanner is the latest innovation for cardiac imaging based on Precision Platform system. The excellent design of Ahart technology which innovatively combined single spiral scan + gated imaging + mA modulation for easy heart imaging at extremely low radiation dose. We provide you ANATOM 64 Clarity/Precision of two models which are low/high configurations for preferences. It also offers you conventional clinical applications of low dose, better image quality and faster exams.
Delivery & Availability:
Typically 90 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | Shipped from Abroad
Incorporating innovative technologies, P20’s user-friendly design with a simple operation panel, intuitive user interface and a variety of intelligent auxiliary scanning tools, will significantly improve your daily examination experience. Besides general imaging applications, P20 has entitled with diagnostic 4D technology which has an extraordinary performance in obstetrics and gynecology applications.
Delivery & Availability:
Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | In stock
- This white coat laboratory coat is a knee-length overcoat/smock is perfect for professionals in the medical field or by those involved in laboratory work.
- This garment is Easy to wash and made from a cotton polyester blend, allowing it to be washed at high temperature and make it easy to see if it is clean.
- Easy to wash.
Delivery & Availability:
Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | Shipped from Abroad
This Machine gives a possibility to perform computed tomography without any problems and on high quality level. This device is used to conduct exams of internal organs and their functioning. With its help, a physician has a possibility to assess the condition of the human body as a whole.
Delivery & Availability:
Typically 90 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. |
Content | Description
https://youtu.be/bEYyQ-uEd0c?si=B6zv0KwgpYM8nTbx
The Stand-alone QUS Bone Densitometer
Portable Device with Embedded PC, Touch Screen and Thermal Printer
SONOST 3000 offers a comfortable and easy-to-handle measurement through its high-sensitive touch screen without an external monitor or a keyboard. Moreover, the built-in thermal printer prints out report cards in a simple format to cut down maintenance cost. The semi-permanent waterless probe with high elasticity makes you feel comfortable on your heel bones. After the measurement, you can simply wipe out the ultrasound gel with a wet wipe. The automatic probe positioning is one of the best solutions for QUS system to minimize its positioning errors.
Features
- SOS and BUA for Measurement of BMD
The ultrasound pulse passing through the bones is significantly attenuated with diffusing signals and absorption by the spongy tissues. And QUS bone mineral density is calculated by the sound of speed (SOS) and Broadband Ultrasound Attenuation (BUA), the data obtained from a density differentiating process of sponge tissues.
- Windows-based Embedded PC
A windows-based embedded PC enables the stand-alone mobile devices.
- USB Port and VGA Connector for External Access
SONOST 3000 can be connected to an external printer, monitor, keyboard and a mouse by USB port and VGA connector.
- Precise Result with Temperature Compensation
SONOST 3000’s algorithm for a temperature compensation function offers more precise result by taking the nearby temperature into consideration at the time of the measurement.
- Optimized System for Minimizing Position Errors
SONOST 3000 minimizes the possible positioning errors by offering a calf supporter, foot positioner, foot supporter, and automatic moving probe table.
- Accurate Measurement with Automatic Moving Probes
An automatic moving probe table always situates itself in the center position, so that it enhances the accuracy of a measurement.
Specifications
Measurement method |
Ultrasound |
Measurement site |
Calcaneus (Heel) |
Measured parameter |
T-score, Z-score, SOS, BUA, BQI index |
Reproducibility |
SOS – ≤ 1% CV
BUA – ≤ 2% CV |
QC check |
Daily QC phantom |
Dimension |
(W)615mm × (D)310mm × (H)312mm (Calf supporter folded)
(W)615mm × (D)310mm × (H)387mm |
Weight |
12.6kg |
| OPENMARK 5000 is 0.51T MRI. It's approved by FDA and has CE mark. It adopts two-pillar magnet design with 280 degree openness and equipped with powerful
RF and gradient system, together with advanced imaging technology, making it as a high-end system which is comparable to high-field MRI.
Features:
- With the highest system stability and the highest homogeneity of the
magnet field in permanent MRI
- Screens on both sides facilitate positioning; 280 degree two-pillar magnet
design ensures stable magnet structure and facilitates interventional
treatment.
- Active and passive shimming calibrate technology ensures the magnetic
field uniformity
- Motor-driven patient couch makes it easier for patients to access and for
positioning
- Powerful hardware and software platforms ensure the scan speed, image
quality and make it possible for advanced imaging functions
- Fast scan speed eliminates motion artifact
- Rich scan sequences, advanced imaging technology and powerful postprocessing
technology ensure image quality, extend more applications,
which can fully satisfy the clinical needs
- Intelligent user-friendly operating system ensures you easy operation
Technical Specifications:
No. |
Technique Description |
Parameter |
1 |
Magnet System |
|
1.1 |
Magnet Type |
Permanent Magnet
Automatic constant temperature
system |
1.2 |
Field Strength |
0.51T |
1.3 |
Magnet Shape |
Dual-pillar shape |
1.4 |
Homogeneity(40cm,DSV,VRMS) |
≤1.6ppm |
1.5 |
Shim Method |
Active/Passive |
1.6 |
Magnet Vertical Gap (Cover) |
40cm |
1.7 |
Magnetic Pole Dia. (Exclude Cover) |
145cm |
1.8 |
Accessibility(Horizontal Opening Angle, |
280° |
1.9 |
5 Gauss fringe field |
X-axis:horizontal ≤2.5m
Y-axis:Vertical ≤2.5m
Z-axis:horizontal ≤2.5m |
2 |
Patient Couch and Communication |
|
2.1 |
Patient Couch Driven mode |
Motor-driven |
2.2 |
Max. Patient Weight |
≥200kg(440lbs) |
2.3 |
Patient Positioning Tools |
Laser Light Localizer for positioning of center slice Motor-driven transfer to center of imaging volume |
2.4 |
Position accuracy |
±1mm |
2.5 |
Emergency Call Key |
Yes |
2.6 |
Intercom System |
Yes |
3 |
Gradient System |
|
3.1 |
Gradient Field Strength(Single Axis) |
≥30mT/m |
3.2 |
Gradient Slew Rate (Single Axis) |
≥100mT/m/ms |
3.3 |
Rise Time |
≤0.3ms |
3.4 |
Gradient Cooling System ( Gradient coils
and Power electronics) |
Air Cooling |
4 |
RF System |
|
4.1 |
RF System Type |
Digital Transmit and
Receive signal |
4.2 |
Number of RF Channels |
4 |
4.3 |
Transmitter Amplifier Peak Power |
6kW |
4.4 |
RF Bandwidth of Receiver |
≥1.25MHz |
4.5 |
Head Coil |
Yes |
4.6 |
Neck Coil |
Yes |
4.7 |
Body/Spine Coil (17 inch) |
Yes |
4.8 |
Body/Spine Coil (21 inch) |
Yes |
4.9 |
Knee Coil |
Yes |
4.10 |
Shoulder Coil |
Yes |
4.11 |
Flexible Coil |
Optional |
4.12 |
Breast Coil |
Optional |
5 |
Computer System |
|
5.1 |
Host Computer |
DELL Computer (for MR) |
5.2 |
System Software |
Windows XP |
5.3 |
Operation Software |
APEX |
5.4 |
CPU Clock rate |
3.0GHz |
5.5 |
Main Memory |
4GB |
5.6 |
Color LCD Monitor |
19” |
5.7 |
Keyboard and Mouse |
Standard |
5.8 |
Image Reconstruction Speed(256 x 256
Matrix) |
200 frame/Sec. |
5.9 |
Hard Disk |
500GB |
5.10 |
Image Storage Capacity(256 x 256
Matrix) |
500,000 |
5.11 |
Media Driver |
DVD RW |
5.12 |
DICOM 3.0 |
Yes |
5.13 |
Ethernet |
Yes |
5.14 |
Operation Console |
Yes |
5.15 |
Operation Chair |
Yes |
6 |
Scanning Parameter |
|
6.1 |
Max. FOV |
410mm |
6.2 |
Min. FOV |
5mm |
6.3 |
Min. TE(SE) |
5ms |
6.4 |
Min. TR(SE) |
11ms |
6.5 |
Min. TE(GR) |
1ms |
6.6 |
Min. TR(GR) |
3ms |
6.7 |
Min. 2D Thickness |
1.0mm |
6.8 |
Min. 3D Thickness |
0.1mm |
6.9 |
Max. Image Matrix |
512x512 |
7 |
Scanning Sequence & Imaging Technique |
|
7.1 |
Spin Echo 2D/3D (SE 2D/3D) |
Yes |
7.2 |
DE/QE |
Yes |
7.3 |
Fast Spin Echo 2D/3D(FSE 2D/3D) |
Yes |
7.4 |
Single Shot FSE 2D/3D |
Yes |
7.5 |
Inversion Recovery(IR) |
Yes |
7.6 |
Fast Inversion Recovery(FIR) |
Yes |
7.7 |
Gradient Echo 2D/3D(GR 2D/3D) |
Yes |
7.8 |
Fast GR 2D/3D |
Yes |
7.9 |
SPGR |
Yes |
7.10 |
FLAIR |
Yes |
7.11 |
Fat Imaging |
Yes |
7.12 |
Fat Suppression imaging |
Yes |
7.13 |
Water-Fat Separation imaging |
Yes |
7.14 |
TOF MRA(2D/3D) |
Yes |
7.15 |
MRCP(2D/3D) |
Yes |
7.16 |
MRU (2D/3D) |
Yes |
7.17 |
MRM |
Yes |
7.18 |
Fast Hydrograph Imaging |
Yes |
7.19 |
Diffusion Weighted Imaging(DWI) |
Yes |
7.20 |
Max. b Value |
1000s/mm2 |
7.21 |
Breath Hold Technology |
Yes |
7.22 |
Magnetization Transfer Contrast(MTC) |
Yes |
7.23 |
Multi-slice and Angle-free Presaturation |
Yes |
7.24 |
Saturation Tracking |
Yes |
7.25 |
Maximum Intensity Projection(MIP) |
Yes |
7.26 |
Multi-Angle Projection(MAP) |
Yes |
7.27 |
3D Reconstruction |
Yes |
7.28 |
Multi-planar Reconstruction(MPR) |
Yes |
7.29 |
Multi-Artifacts Eliminating technology |
Yes |
7.30 |
Checking with Part Metal Implant |
Yes |
7.31 |
Online Image Filtration |
Yes |
7.32 |
Online Post Procession |
Yes |
7.33 |
3D Scout |
Yes |
7.34 |
Scanning Protocol Preset |
Yes |
7.35 |
Scanning Protocol Queue Waiting |
Yes |
7.36 |
Advanced Image Post Processing |
Yes |
7.37 |
Image Fusion Technology of Vascular |
Yes |
7.38 |
Image Fusion Technology of Spine |
Yes |
| The ANATOM 64 CT scanner is the latest innovation for cardiac imaging based on Precision Platform system. The excellent design of Ahart technology which innovatively combined single spiral scan + gated imaging + mA modulation for easy heart imaging at extremely low radiation dose. We provide you ANATOM 64 Clarity/Precision of two models which are low/high configurations for preferences. It also offers you conventional clinical applications of low dose, better image quality and faster exams.
Features:
- Modularized OptiWave HD detector features low-cost & easy maintenance, high spatial resolution and long lifetime
- Admir3D iterative technology delivers optimal dose efficiency and noise reduction without compromising image quality
- High configurations of main components ensure the best results and maximum patient throughput
- Uniquely and creatively uses 140kV and 80kV dual energy scan mode for brain imaging on 16-slice CT to offers you extraordinary image quality both in low and high density resolutions
- AdoseTM mA modulation ensures you low dose imaging without compromising image quality particularly useful in pediatric applications
- Equipped with dedicated Abast and Amast for bone and metal artifacts
- The brilliant Ahart technology enables you to experience so easy and low-dose cardiac imaging applications
Technical Specifications:
Model |
ANATOM 64 Precision |
ANATOM 64 Fit |
Rack type |
Low pressure slip ring |
Low pressure slip ring |
Scan aperture |
70cm |
70cm |
Rack Physical inclination |
± 30 ° |
N.A |
Rack digital inclination |
± 50 ° |
± 50 ° |
cooling method |
Air-cooled |
Air-cooled |
Focus to the center distance |
56 cm |
53 cm |
|
|
|
Maximum power (non-equivalent) |
80kW |
42kW |
Votage (kV) |
80kV / 100kV / 120kV / 140kV |
70kV / 80kV / 100kV / 120kV /
140kV |
|
|
|
Heat capacity |
8MHU |
5.0MHU |
Heat dissipation rate |
931 kHU / min |
748kHU / min |
cooling method |
Oil cool |
Oil cool |
Large focus size |
1.1mm × 1.2mm |
1.2mm × 1.4mm |
Small focus size |
0.6mm × 1.2mm |
0.7mm × 0.8mm |
Tube current range |
10-670mA |
10-350mA |
|
|
|
Detector type |
Optiwave detectors |
Optiwave detectors |
Number of Z-axis |
32 |
32 |
The width of the Z-axis |
20mm |
20mm |
The number of elements per row |
912 |
848 |
Total number of detectors |
29184 |
27136 |
Acquisition mode |
64x0.625, 32x0.625,
16x0.625 |
64x0.625, 32x0.625,
16x0.625 |
|
|
|
Scanning range |
1800mm |
1800mm |
Horizontal positioning accuracy |
± 0.25mm |
± 0.25mm |
weight capacity |
205kg |
205kg |
Minimum height |
43cm |
43cm |
Anti - collision protection device |
Yes |
Yes |
Foot control switch |
Yes |
Yes |
IV rack |
Yes |
Yes |
|
|
|
CPU |
3.5GHz |
3.5GHz |
RAM |
16 GB × 4 |
16 GB × 4 |
Hard drive capacity |
1T × 2 |
1T × 2 |
Display size |
24 inch LCD monitor |
24 inch LCD monitor |
Display resolution |
1920 × 1200 |
1920 × 1200 |
Computer operating system |
Windows 7 |
Windows 7 |
Image reconstruction speed |
65 frames/ second |
65 frames/ second |
Number of image store |
1000000 |
1000000 |
Data external storage mode |
CD / DVD / USB |
CD / DVD / USB |
|
|
|
Minimum Scan Time of 360 degree |
0.39sec |
0.75sec |
Sub-millimeter acquisition layers |
64 |
64 |
Double sub-millimeter acquisition
layers |
64 |
64 |
Thinnest acquisition thickness |
0.625mm |
0.625mm |
The thinnest reconstruction
thickness |
0.3125mm |
0.625mm |
Conventional reconstruction
thickness (mm) |
0.3125 mm, 0.625 mm, 1.25 mm, 2.5
mm, 5.0 mm, 7.5 mm, 10 mm |
0.625 mm, 1.25 mm, 2.5 mm, 5.0
mm, 7.5 mm, 10 mm |
The reconstruction matrix |
512 x 512, 1024 x 1024 |
512 x 512, 1024 x 1024 |
Display matrix |
1024 × 1024 |
1024 × 1024 |
Max FOV |
52cm |
50cm |
The maximum display field of view |
70cm |
50cm |
Maximum scan length |
1800mm |
1800mm |
Maximum continuous helix scan
time |
120s |
120s |
Pitch range |
0.5-1.5 |
0.5, 1.0, 1.5 |
|
|
|
High contrast resolution |
21 Lp / cm @ 0% MTF |
21 Lp / cm @ 0% MTF |
Low contrast resolution |
2mm @ 0.3% |
2mm @ 0.3% |
Image noise |
≤ 0.25 |
≤ 0.29 |
|
|
|
MPR |
Yes |
Yes |
CPR |
Yes |
Yes |
SSD |
Yes |
Yes |
VR |
Yes |
Yes |
MIP |
Yes |
Yes |
MinIP |
Yes |
Yes |
Virtual endoscopy |
Yes |
Yes |
CT angiography |
Yes |
Yes |
Tissue segmentation |
Yes |
Yes |
One-key bone removal |
Yes |
Yes |
Automatically patient table removal |
Yes |
Yes |
Contrast Agent Automatic Tracking
Technology- bolus tracking |
Yes |
Yes |
Automatic linkage trigger
technology |
Yes |
Yes |
Cine mode display |
Yes |
Yes |
Bone artifact suppression technique |
AbastTM |
AbastTM |
Metal artifact suppression technique |
AbastTM |
AbastTM |
Iterative reconstruction technique |
Admir3D global iteration |
Admir3D full-domain iteration |
Low - dose children 's scanning
technology |
Yes |
Yes |
Low - dose lung scan |
Yes |
Yes |
Gray matter enhancement
technology |
AccuHead |
AccuHead |
High resolution imaging of the lung |
AccuLung |
AccuLung |
Inner ear high resolution imaging |
AccuOtica |
AccuOtica |
Body high resolution imaging |
AccuBody |
AccuBody |
Bone high resolution imaging |
AccuBone |
AccuBone |
Head dual-energy imaging |
Ahead |
Ahead |
CT perfusion imaging |
Optional |
Optional |
Quantitative analysis of blood
vessels |
Optional |
Optional |
Heart coronary artery imaging |
Aheart |
N.A |
ECG gated |
Yes |
N.A |
Low dose cardiac scan |
Yes |
N.A |
|
|
|
Green energy saving technology |
AccuSaving |
AccuSaving |
Dual-energy scan technology |
Optional |
Optional |
| DETAILS
Upgraded Images with More Clarity
SonoScape never stops making progress in improving the image quality of its ultrasound products to enhance the confidence of diagnosis for doctors. With extraordinary images provided by P20, the anatomy structures are clearer than ever.
C-Xlasto Imaging
With C-xlasto Imaging, P20 enables comprehensive quantitative elastic analysis. Meanwhile, C-xlasto on P20 is supported by linear, convex and transvaginal probes, to ensure good reproducibility and highly consistent quantitative elastic results.
S-Live
S-Live allows for detailed visualization of subtle anatomical features, thereby enabling intuitive diagnosis with real-time 3D images and enriching patient communication.
Pelvic Floor 4D
Transperineal 4D pelvic floor ultrasound can provide useful clinical values in assessing the vaginal delivery impact on the female anterior compartment, judging whether the pelvic organs are prolapsed or not and the extent, determining if the pelvic muscles were torn accurately.
Anatomic M Mode
Anatomic M Mode helps you observe the myocardial motion at different phases by freely placing sample lines. It accurately measures the myocardial thickness and the heart size of even difficult patients and supports the myocardial function and LV wall-motion assessment.
Tissue Doppler Imaging
P20 is endowed with Tissue Doppler Imaging which provides velocities and other clinical information on myocardial functions, facilitating clinical doctors with the ability to analyze and compare the motions of different parts of the patient's heart.
|
- This white coat laboratory coat is a knee-length overcoat/smock is perfect for professionals in the medical field or by those involved in laboratory work.
- This garment is Easy to wash and made from a cotton polyester blend, allowing it to be washed at high temperature and make it easy to see if it is clean.
- Easy to wash.
| This Machine gives a possibility to perform computed tomography without any problems and on high quality level. This device is used to conduct exams of internal organs and their functioning. With its help, a physician has a possibility to assess the condition of the human body as a whole.
Features:
- It is easy to use;
- Convenience;
- Multi functionality;
- Obtained images are of high definition;
- High-definition 3D images of the area under study;
- The procedure is pain-free;
- The data is processed fast;
- The image can be stored in the computer memory;
- The diagnostics does not take a lot of time;
- Acceptable radiation dose.
Technical Specifications:
No. |
Technical Features |
Descriptions |
1 |
Gantry |
|
1.01 |
Gantry type |
Low voltage slip-ring |
1.02 |
Gantry driven type |
Strap-driven |
1.03 |
Patient opening |
70cm |
1.04 |
Gantry tilt mode |
Digital gantry tilt |
1.05 |
Digital tilt capability |
±50° |
1.06 |
Detector type |
OptiWave rare-earth ceramic detector |
1.07 |
Numbers of detector rows |
16 |
1.08 |
Width of Z-axle detector |
20mm |
1.09 |
Detector columns of channels per row |
848 |
1.10 |
Numbers of detector columns |
13568 |
1.11 |
Data-transfer type |
RF, optical fiber communication |
1.12 |
Distance of focus-ISO-center |
53cm |
1.13 |
Distance of focus-detector |
94cm |
1.14 |
3D laser orientation |
Provided |
1.15 |
13" integrated display panel |
Provided |
1.16 |
Adose automatic exposure control (mA
Modulation) |
Provided |
1.17 |
Auto-voice manager |
Breath Graphical Display
Hold Message (Record/Playback)
Breath Message (Record/Playback) |
1.18 |
AccuSaving energy conservation management |
Provided |
2 |
HVPS and X-ray tube |
|
2.01 |
Maximum continuous output of HVgenerator |
42kW |
2.02 |
Tube kV selections |
70kV, 80kV, 100 kV, 120 kV, 140 kV |
2.03 |
Tube mA range |
10~350mA |
2.04 |
Tube anode heat capacity |
3.5MHU |
2.05 |
Max. anode cooling rate |
735kHU/min |
2.06 |
Type of cooling |
Oil cooling + Air cooling |
2.07 |
Tube focus |
Large: 1.2mm×1.4mm
Small: 0.7mm×0.8mm |
2.08 |
Collimator width selection |
4-level election |
2.09 |
Focus spot tracking technology |
Provided |
3 |
Patient table |
|
3.01 |
Maximum horizontal-movable range |
1850mm |
3.02 |
Table horizontal-scannablerange |
1800mm |
3.03 |
Table horizontal-position repeatability |
±0.25mm |
3.04 |
Minimum height above floor |
430mm |
3.05 |
Maximum vertical-movable range |
500mm |
3.06 |
Maximum speed of vertical movement |
35mm |
3.07 |
Maximum speed of horizontal movement |
150mm/s |
3.08 |
Maximum patient weight |
205kg |
3.09 |
Foot pedal of patient table control |
Provided |
4 |
Computer |
|
4.01 |
CPU |
3.5GHz |
4.02 |
Memory |
32GB |
4.03 |
Storage of hard-disk |
1TB×2 |
4.04 |
Monitor |
24’’ LCD Monitor |
4.05 |
Resolution of monitor |
1920×1200 |
4.06 |
Image-data external storage type |
CD/DVD/USB |
4.07 |
Time of image reconstruction (512×512) |
33.3ms/image |
4.08 |
Speed of image reconstruction (512×12) |
30fps |
4.09 |
DICOM 3.0 interface |
Provided |
4.10 |
Printer DICOM 3.0 interface |
Provided |
4.11 |
Auto filming |
Provided |
4.12 |
Worklist function |
Provided |
5 |
Scan parameters |
|
5.01 |
Shortest 360 degree rotation time |
0.75s |
5.02 |
Allowed rotation times |
0.75s, 1.0s, 1.5s, 2.0s, 3.0s, 4.0s |
5.03 |
Maximum slice numbers per rotation |
32 |
5.04 |
Minimum slice thickness of scan |
1.25mm |
5.05 |
Minimum slice thickness of reconstruction |
0.625mm |
5.06 |
Maximum slice thickness of scan |
20mm |
5.07 |
Nominal reconstruction slice thickness |
0.625mm, 1.25mm, 2.5mm, 5.0mm, 7.5mm,
10mm, 20mm |
5.08 |
Speed of image reconstruction (512×512) |
30 frames/s |
5.09 |
Scan FOV |
50cm |
5.10 |
Image reconstruction matrix |
512×512, 1024×1024 (Optional) |
5.11 |
Image reconstruction matrix |
512×512, 1024×1024 (Optional) |
5.12 |
Image display matrix |
512×512, 1024×1024 (Optional) |
5.13 |
Maximum continuous scan duration |
120s |
5.14 |
Maximum continuous scan length |
180cm |
5.15 |
Direction of TOPO |
Front-back, Left-right |
5.16 |
Max. length of TOPO |
180cm |
5.17 |
Range of pitch |
0.5~1.5 |
5.18 |
Scan mode |
Scout scan
Axial scan
Helical scan
Cine scan |
6 |
Image Quality |
|
6.01 |
High contrast resolution |
21lp/cm@0%MTF |
6.02 |
Low contrast resolution |
2.0mm@0.30% |
6.03 |
Isotropic imaging resolution |
0.24mm |
6.04 |
Range of CT numbers |
-32767~32768 |
6.05 |
Image noise |
≤0.29@28mGy |
7 |
Advanced application |
|
7.01 |
Multi-Planar Reconstruction (MPR) |
Provided |
7.02 |
Curve Multi-Planar Reconstruction (CPR) |
Provided |
7.03 |
Surface Shaded Display (SSD) |
Provided |
7.04 |
Volume Rendering (VR) |
Provided |
7.05 |
Maximum Intensity Projection (MIP) |
Provided |
7.06 |
Minimum Intensity Projection (MinIP) |
Provided |
7.07 |
Virtual Endoscopy (VE) |
Provided |
7.08 |
CT angiography (CTA) |
Provided |
7.09 |
Tissue segmentation |
Provided |
7.10 |
One click bone remove |
Provided |
7.11 |
One click patient table remove |
Provided |
7.12 |
Bolus-tracking Technology |
Provided |
7.13 |
Spiral auto start |
Provided |
7.14 |
Cine display |
Provided |
7.15 |
AbastTM bone artifact suppression technology |
Provided |
7.16 |
AmastTM metal artifact suppression technology |
Provided |
7.17 |
Admir3D all-domain iterative reconstruction |
Provided |
7.18 |
Low-dose pediatric scan technology |
Provided |
7.19 |
Low-dose lung scan technology |
Provided |
7.20 |
AccuHead grey-white matter enhanced
technology |
Provided |
7.21 |
AccuOrgan lung high resolution scan technology |
Provided |
7.22 |
AccuOrgan inner-ear high resolution scan
technology |
Provided |
7.23 |
AccuOrgan body high resolution scan technology |
Provided |
7.24 |
AccuOrgan bone high resolution scan technology |
Provided |
7.25 |
AccuMatter dual-energy with Admir3D for new
application |
Provided |
|
Reviews