BRAINSWAY Deep TMS H7 Coil

$0.00

Shipped From Abroad

The H7 Coil stimulates the anterior cingulate cortex and the medial prefrontal cortex. Complementing a large-scale, double-blind, multicenter randomized controlled trial, which demonstrated strong response rates, greater than 1 in 2 OCD patients who completed 29 sessions in real clinical practice achieved sustained response.

Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Brands:: BrainsWay

Description

The BrainsWay Deep TMS H7 Coil is a flexible coil used in transcranial magnetic stimulation (TMS) to stimulate the brain’s medial prefrontal cortex and anterior cingulate cortex:
The H7 Coil stimulates the anterior cingulate cortex and the medial prefrontal cortex. Treatment is designed to regulate the CSTC circuit believed to be involved in the inhibition of impulsive behavior. A sham coil is integrated above the treatment coil.
  • What it does

    The H7 Coil is FDA-cleared to treat obsessive-compulsive disorder (OCD). It can also be used to treat other neuropsychiatric disorders, such as addiction, major depressive disorder, and autism spectrum disorder. 

  • How it works

    TMS uses magnetic pulses to induce an electrical current in the brain’s neuronal tissue. The H7 Coil is integrated into a cooled, cushioned helmet that allows the patient to move around during treatment. 

  • How it’s used

    The H7 Coil is designed to reach deeper and broader regions of the brain than previous TMS coils. The treatment is non-invasive and well-tolerated, with no adverse or long-lasting side effects. 

  • How it’s delivered
    The treatment involves multiple sessions, each lasting about 18 minutes.

    Click here to download Brochure

Reviews

There are no reviews yet.

Be the first to review “BRAINSWAY Deep TMS H7 Coil”

Your email address will not be published. Required fields are marked *

Quick Comparison

SettingsBRAINSWAY Deep TMS H7 Coil removeDolphin-IQ Transcranial Doppler Probe removeFalcon-QUAD Transcranial Doppler Probe removeSelf-Retaining Retractor removeBRAINSWAY Deep TMS H7 RCT Coil removeND-8S EEG Monitor remove
NameBRAINSWAY Deep TMS H7 Coil removeDolphin-IQ Transcranial Doppler Probe removeFalcon-QUAD Transcranial Doppler Probe removeSelf-Retaining Retractor removeBRAINSWAY Deep TMS H7 RCT Coil removeND-8S EEG Monitor remove
Image
SKUSF1033560130142-3SF1033560130142-6
Rating
Price

$0.00

$6,325.00

$0.00

$0.00

$0.00

$0.00

Stock
Availability
Add to cart

DescriptionShipped From Abroad The H7 Coil stimulates the anterior cingulate cortex and the medial prefrontal cortex. Complementing a large-scale, double-blind, multicenter randomized controlled trial, which demonstrated strong response rates, greater than 1 in 2 OCD patients who completed 29 sessions in real clinical practice achieved sustained response.
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad All of the advantages and performance of the cutting-edge Dolphin TCD technology for measurements of cerebral blood flow velocities are implemented in the smart and compact Dolphin/IQ Transcranial Doppler module.
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.

Shipped From Abroad

State-of-the-Art technology to measure ABI, TBI, Doppler, PVR, PPG and stress testing. Falcon advanced EMR and PACS capabilities and reporting options are designed for medical centers and private clinics alike
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad The H7 Coil stimulates the anterior cingulate cortex and the medial prefrontal cortex.  Treatment is designed to regulate the CSTC circuit believed to be involved in the inhibition of impulsive behavior. A sham coil is integrated above the treatment coil. To the patient and operator, the helmet appears the same, pulses sound the same, and stimulation feels the same on the scalp.
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad

Early diagnosis and early treatment, are dedicated to the "stationary" solutions for brain function diagnosis and treatment.

Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Content
The BrainsWay Deep TMS H7 Coil is a flexible coil used in transcranial magnetic stimulation (TMS) to stimulate the brain's medial prefrontal cortex and anterior cingulate cortex:
The H7 Coil stimulates the anterior cingulate cortex and the medial prefrontal cortex. Treatment is designed to regulate the CSTC circuit believed to be involved in the inhibition of impulsive behavior. A sham coil is integrated above the treatment coil.
  • What it does
    The H7 Coil is FDA-cleared to treat obsessive-compulsive disorder (OCD). It can also be used to treat other neuropsychiatric disorders, such as addiction, major depressive disorder, and autism spectrum disorder. 
  • How it works
    TMS uses magnetic pulses to induce an electrical current in the brain's neuronal tissue. The H7 Coil is integrated into a cooled, cushioned helmet that allows the patient to move around during treatment. 
  • How it's used
    The H7 Coil is designed to reach deeper and broader regions of the brain than previous TMS coils. The treatment is non-invasive and well-tolerated, with no adverse or long-lasting side effects. 
  • How it's delivered
    The treatment involves multiple sessions, each lasting about 18 minutes.
    Click here to download Brochure
https://youtu.be/Id0Ma1_lEo0?si=kRJ1bUMjUCBuCAqR  
Features of Dolphin TCD Machine

Best Quality Doppler

Fully digital Doppler technology with the amazing Dolphin TCD post-processing capabilities lets you review and replay the measured spectrum with audio at any depth. Unmatched clinical diagnosis capabilities.

Best TCD Robotic Probe

The unique Dolphin/XF robotic probe changes the Transcranial Doppler monitoring market as is known to date. Fast and simple scanning is achieved thanks to special algorithms and processes for blood flow detection. The Dolphin/XF robot is comfortable and stable, simplifying probe fixation and saving time.

Continuous Monitoring Made Easy

The Dolphin devices are well designed to assist the technician or physician in performing short or long-term Monitoring. The Dolphin Headset design comes with the unique probe Quick-Lock – the best locking solution. The Dolphin software is rich with quality features for optimal patient diagnosis, including a complete replay of the entire recording, placement of automatic and predefined markers, and availability of trends display.

Unbeatable Durability and Reliability

The Dolphin is considered by many as the most reliable Transcranial Doppler machine in the market. A range of high-quality Doppler probes is available for different clinical applications and optimal Doppler penetration of the temporal window.

Designed for Portability

The Dolphin TCD machines are the most portable TCD machine on the market. Dolphin/MAX and Dolphin/4D are slim, lightweight, and have a large 18″ Touch Screen, which can be seen from a distance in the ICU or other clinical settings. Their design allows you to simply hand carry them or use the VESA mount options to easily connect the TCD system to a cart or trolley. The Dolphin/MAX has a built-in integrated battery that lasts for hours.

Complete Network Connectivity

The unmatched Dolphin connectivity capabilities are ideal for hospital IT personnel and EMR / PACS administrators. The advanced Dolphin TCD networking abilities allow a simple plug-and-play operation to quickly configure connectivity with automated DICOM Worklist & Storage, Structured Report, and HL7. With unlimited Review Stations, measurements can be reanalyzed and interpreted from the comfort of your office. Final reporting can also be configured and finalized from any location.

Unmatched HITS Detection

Optimal and accurate counts of suspected embolic events using a high-resolution proprietary algorithm that simultaneously detects HITS (emboli events) in all gates! The numerous advanced analysis options of each suspected emboli include an extraordinary high-resolution power M Mode display during HITS detection (up to 50 times faster than the Doppler spectrum!).
https://youtu.be/YSWvhSIS1ho?si=rXtjG78U7PQgzrlf  
Features of Falcon Physiologic Machine

Segmental Blood Pressures

Measure lower extremity pressures easily with 10 color-coded channels and a variety of Doppler probes and PPG sensors. Complete the vascular diagnosis with supportive stress testing. Falcon is considered by many the best segmental pressure machine with numerous advanced features such as 10 simultaneous PVR measurements and limitless post-processing capabilities.

Fast and Accurate ABI & TBI

Quickly measure ABI and TBI with either Doppler or Photoplethysmography (PPG). With the Falcon ABI and TBI machine, all measurements are saved automatically and sent directly to the dedicated interactive summary screen.

Highest Durability and Reliability

The Falcon is the most reliable peripheral vascular machine in the market. Thanks to the high quality Doppler probes, 10 Independent Pressure Channels (IPU Technology) and 5 PPG Ports, the Falcon design significantly reduces any down-time. Falcon is in distributed worldwide for over 10 years with the lowest fail rate in the market!

Complete Network Connectivity

The Falcon unmatched connectivity capabilities are a paradise to hospital IT personnel and EMR and PACS managers. The advanced networking abilities allow a plug-and-play operation to easily configure connectivity with automated DICOM Worklist & Storage, Structured Report, and HL7. With unlimited Review Stations, measurements can be reanalyzed and interpreted from the comfort of your office. Final reporting can also be configured and finalized from any location.

Simplify Your Workflow

The Falcon vascular diagnosis device has the ability to configure as many dedicated examination protocols that allow to save time and optimize the patient vascular diagnosis​. Enjoy the user-friendly protocol builder to configure your workflow according to your needs!​

Ease of Use

Minimal learning curve thanks to user-friendly software with a large touch-screen display. A selection of wired and wireless remote control​ and footswitch allows keeping your focus on the patient rather than on the physiologic vascular equipment.

Dedicated Specialty Tests

The Falcon is the complete vascular physiologic assessment machine with dedicated protocols that guide you through step-by-step diagnostic measurements of specific vascular conditions.  The dedicated diagnosis protocols include measurements of Thoracic Outlet Syndrome (TOS), diagnosis of Raynaud’s Phenomenon, evaluation of Penile Function or Erectile Dysfunction, assessment of Allen’s Test (or Palmar Arch Test), measurements of Venous Reflux and Venous Capacitance and Outflow, Pulse Wave Velocity, and more.
Advanced Reporting The famous Falcon user-friendly report builder tool allows you to design your own report layout easily. Then, add your institute/clinic logo and details to create a detailed and impressive diagnosis report that meets your institute standards. Save a lot of time by building your report with preconfigured interpretation templates.

Advanced Research Options

The Falcon vascular research machine is famous for its built-in statistics tool with on-screen graphs, segments filtering, and Excel tool, which are all designed to simplify the work of vascular and physiological researchers. Export to PDF, Excel, Word, JPEG, VSX, Video clips, and more to support your vascular research and teaching needs, as well as support your clinical vascular publications.
CODE SIZE FINISH
01-01-02 12.8 cm sharp
The Brainsway Deep TMS H7 RCT Coil is a flexible coil used in transcranial magnetic stimulation (TMS) to treat obsessive-compulsive disorder (OCD) and other neuropsychiatric conditions:
  • What it does
    The H7 Coil stimulates the medial prefrontal cortex and the anterior cingulate cortex of the brain. TMS uses magnetic pulses to create an electrical current in the brain's neuronal tissue. 
  • How it's used
    The H7 Coil is integrated into a cooled, cushioned helmet that allows the patient to move around during treatment. A sham coil is also included so that the patient and operator can't tell the difference between the treatment and sham coils. 
  • What it's used for
    The H7 Coil is FDA-cleared for OCD, but it's also been shown to be effective in treating other conditions, including addiction, major depressive disorder, and autism spectrum disorder. 
  • How it works
    The H7 Coil is designed to regulate the CSTC circuit, which is thought to be involved in impulsive behavior. 
  • Safety
    A 2023 paper that analyzed adverse events from five large, randomized controlled trials found that most adverse events were transient and resolved within days.
Features
  • Stimulates specific brain regions
    The H7 Coil targets the anterior cingulate cortex and the medial prefrontal cortex. 
  • Flexible windings
    The H7 Coil's flexible windings conform to the shape of the patient's head. 
  • FDA-cleared for OCD
    The H7 Coil is FDA-cleared for treating obsessive-compulsive disorder (OCD). 
  • Demonstrated efficacy
    The H7 Coil has been shown to be effective in treating OCD patients with varying degrees of severity and comorbidities. 
  • Integrated sham coil
    The helmet includes a sham coil that makes the treatment appear, sound, and feel the same to the patient and operator.

Click here to download Brochure

Features
HIE multi-dimensional identification and application 1) According to the amplitude and continuity of the upper/lower boundary of aEEG, the neonatal EEG activity will be classified, and the Hellstrom-Westas background five-classification method will be used to improve the ability of medical staff to identify the aEEG waveforms; 2) Masimo Rainbow SET pulse oximetry monitoring, monitor the SpO2/PI/PR change in a non-invasive and continuous manner, effectively eliminate the exercise interference, and improve the measurement performance under low perfusion and body motion.
  • Rechargeable battery Equipped with a rechargeable lithium-ion battery to support 2h independent working time, which is convenient for transfer of patient.
  • Real-time detection of electrode impedance Provide the function of real-time detection of electrode impedance to ensure the validity of the detection information.
  • Stable integrated medical trolley Compliant with the allowable load in IEC60601-1, more stable than ordinary trolleys, easy to move, and special for bedside monitoring.
     
  • Epilepsy rapid identification and application 1) Envelope trend chart (ENVELOPE) is used to represent the change in the EEG amplitude, which can better eliminate the artifacts caused by interference and identify epileptic seizure events more accurately; 2) TP (total power), also known as total energy, reflects the change in the EEG amplitude and has high sensitivity and low specificity for clinically detecting epileptic seizures.
 
  • Medical all-in-one machine - "intuitive display in the multi-trend chart" 1) Complies with the EU CE-related: EN60601-1-2: 2015 and EN60601-1: 2006 standards, with better hardware security, stability, durability, and anti-interference; 2) Equipped with a 19-inch color touch medical-grade display screen, displays each trend chart and corresponding values clearly and intuitively; 3) Provides a variety of trend chart displays and real-time EEG displays to help clinicians interpret data in time and ensure the accuracy of clinical diagnosis.
 
  • Signal amplifier - "multi-channel signal acquisition" 1) Standard 4 channels and optional 8/12 channels, with impedance selection button, built-in SpO2 input channel, less interference from the environment, and more stable signal acquisition; 2) With strong anti-interference performance, it can also record high-quality electrophysiological signals in the complex NICU and operating room environments and during the transfer process.
 
  • High-definition night-vision video monitoring 1) The optional high-definition camera with night vision function supports horizontal and vertical rotation, and the illumination distance can be up to 20m; 2) The physical movement of patients can be monitored in a real-time manner through the LCD screen, eliminate artifacts caused by various interference, and detects EEG signals accurately.
WeightN/AN/AN/AN/AN/AN/A
DimensionsN/AN/AN/AN/AN/AN/A
Additional information
Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • Rating
  • Price
  • Description
Click outside to hide the comparison bar
Compare