BRAINSWAY Deep TMS H7 Coil

$0.00

Shipped From Abroad

The H7 Coil stimulates the anterior cingulate cortex and the medial prefrontal cortex. Complementing a large-scale, double-blind, multicenter randomized controlled trial, which demonstrated strong response rates, greater than 1 in 2 OCD patients who completed 29 sessions in real clinical practice achieved sustained response.

Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
SF1033560130162-5
Brands:: BrainsWay

Description

The BrainsWay Deep TMS H7 Coil is a flexible coil used in transcranial magnetic stimulation (TMS) to stimulate the brain’s medial prefrontal cortex and anterior cingulate cortex:
The H7 Coil stimulates the anterior cingulate cortex and the medial prefrontal cortex. Treatment is designed to regulate the CSTC circuit believed to be involved in the inhibition of impulsive behavior. A sham coil is integrated above the treatment coil.
  • What it does

    The H7 Coil is FDA-cleared to treat obsessive-compulsive disorder (OCD). It can also be used to treat other neuropsychiatric disorders, such as addiction, major depressive disorder, and autism spectrum disorder. 

  • How it works

    TMS uses magnetic pulses to induce an electrical current in the brain’s neuronal tissue. The H7 Coil is integrated into a cooled, cushioned helmet that allows the patient to move around during treatment. 

  • How it’s used

    The H7 Coil is designed to reach deeper and broader regions of the brain than previous TMS coils. The treatment is non-invasive and well-tolerated, with no adverse or long-lasting side effects. 

  • How it’s delivered
    The treatment involves multiple sessions, each lasting about 18 minutes.

    Click here to download Brochure

Reviews

There are no reviews yet.

Be the first to review “BRAINSWAY Deep TMS H7 Coil”

Your email address will not be published. Required fields are marked *

Quick Comparison

SettingsBRAINSWAY Deep TMS H7 Coil removeFalcon-ABI+ Transcranial Doppler Probe removeBRAINSWAY Deep TMS H4 RCT Coil removeRetractors removeBRAINSWAY Deep TMS H4 Coil removeEctron Ectonustim Series 6 Electroconvulsive Therapy ECT Machine remove
NameBRAINSWAY Deep TMS H7 Coil removeFalcon-ABI+ Transcranial Doppler Probe removeBRAINSWAY Deep TMS H4 RCT Coil removeRetractors removeBRAINSWAY Deep TMS H4 Coil removeEctron Ectonustim Series 6 Electroconvulsive Therapy ECT Machine remove
Image
SKUSF1033560130162-5SF1033560130142-7SF1033560130162-8SF1033560130176-9SF1033560130162-7SF10335601235
Rating
Price

$0.00

$0.00

$0.00

$0.00

$0.00

$0.00

Stock
Availability
Add to cart

DescriptionShipped From Abroad The H7 Coil stimulates the anterior cingulate cortex and the medial prefrontal cortex. Complementing a large-scale, double-blind, multicenter randomized controlled trial, which demonstrated strong response rates, greater than 1 in 2 OCD patients who completed 29 sessions in real clinical practice achieved sustained response.
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad The H4 Coil stimulates the bilateral insula and prefrontal cortex. This includes neurons in brain structures associated with addiction. A sham coil is integrated above the treatment coil. To the patient and operator, the helmet appears the same, pulses sound the same, and stimulation feels the same on the scalp.
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad The H4 Coil stimulates the bilateral insula and prefrontal cortex. Nearly 1 in 3 patients who completed 18 sessions achieved 4 or more weeks of abstinence from smoking in a large scale, double-blind, multicenter randomized controlled trial. 2 out of 3 patients who quit smoking by the end of treatment remained abstinent for at least an additional three months
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad

This machines have been developed from the well-proven Series 5A and 5B ECT apparatus. The series 6+ models incorporate all the features of the corresponding Series 5B versions. Experience has shown that a very few patients sometimes require higher dosage than was available with the earlier machines and the opportunity was therefore taken to produce equipment with a second, higher, output range.

Delivery & Availability: Typically 3 Months – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Content
The BrainsWay Deep TMS H7 Coil is a flexible coil used in transcranial magnetic stimulation (TMS) to stimulate the brain's medial prefrontal cortex and anterior cingulate cortex:
The H7 Coil stimulates the anterior cingulate cortex and the medial prefrontal cortex. Treatment is designed to regulate the CSTC circuit believed to be involved in the inhibition of impulsive behavior. A sham coil is integrated above the treatment coil.
  • What it does
    The H7 Coil is FDA-cleared to treat obsessive-compulsive disorder (OCD). It can also be used to treat other neuropsychiatric disorders, such as addiction, major depressive disorder, and autism spectrum disorder. 
  • How it works
    TMS uses magnetic pulses to induce an electrical current in the brain's neuronal tissue. The H7 Coil is integrated into a cooled, cushioned helmet that allows the patient to move around during treatment. 
  • How it's used
    The H7 Coil is designed to reach deeper and broader regions of the brain than previous TMS coils. The treatment is non-invasive and well-tolerated, with no adverse or long-lasting side effects. 
  • How it's delivered
    The treatment involves multiple sessions, each lasting about 18 minutes.
    Click here to download Brochure
https://youtu.be/YSWvhSIS1ho?si=3W6Cb6LTqWccEtiz
Features of Falcon Physiologic Machine

Segmental Blood Pressures

Measure lower extremity pressures easily with 10 color-coded channels and a variety of Doppler probes and PPG sensors. Complete the vascular diagnosis with supportive stress testing. Falcon is considered by many the best segmental pressure machine with numerous advanced features such as 10 simultaneous PVR measurements and limitless post-processing capabilities.

Fast and Accurate ABI & TBI

Quickly measure ABI and TBI with either Doppler or Photoplethysmography (PPG). With the Falcon ABI and TBI machine, all measurements are saved automatically and sent directly to the dedicated interactive summary screen.  

High Quality Doppler Probes

In addition, to the 4 MHz and 8 MHz probes for standard use, the advanced Falcon/Quad and Falcon/Pro Doppler machines offer a unique 10 MHz probe, which is designed to measure particularly small peripheral blood vessels. All Falcon Doppler probes produce complete high-resolution Doppler spectral analysis with the aid of the Falcon vascular software and algorithms.

State-of-the-Art PPG Sensors

Falcon offers a wide selection of Photoplethysmography sensors.   The 5 completely independent PPG ports allow simultaneous fingers/toes measurements, which is especially useful for Raynaud’s diagnosis along with a an integrated temperature sensor.  Fingerclip and Toeclip PPG sensors are recommended for routine examinations. The Disc PPG sensors are particularly useful for Venous Reflux testing and are supplied with dedicated adhesive stickers.  

Highest Durability and Reliability

The Falcon is the most reliable peripheral vascular machine in the market.  Thanks to the high quality Doppler probes, 10 Independent Pressure Channels (IPU Technology) and 5 PPG Ports, the Falcon design significantly reduces any down-time.  Falcon is in distributed worldwide for over 10 years with the lowest fail rate in the market!

Complete Network Connectivity

The Falcon unmatched connectivity capabilities are a paradise to hospital IT personnel and EMR and PACS managers. The advanced networking abilities allow a plug-and-play operation to easily configure connectivity with automated DICOM Worklist & Storage, Structured Report, and HL7. With unlimited Review Stations, measurements can be reanalyzed and interpreted from the comfort of your office. Final reporting can also be configured and finalized from any location.

Simplify Your Workflow

The Falcon vascular diagnosis device has the ability to configure as many dedicated examination protocols that allow to save time and optimize the patient vascular diagnosis​. Enjoy the user-friendly protocol builder to configure your workflow according to your needs!​

Ease of Use

Minimal learning curve thanks to user-friendly software with a large touch-screen display. A selection of wired and wireless remote control​ and footswitch allows keeping your focus on the patient rather than on the physiologic vascular equipment.

Dedicated Specialty Tests

The Falcon is the complete vascular physiologic assessment machine with dedicated protocols that guide you through step-by-step diagnostic measurements of specific vascular conditions.  The dedicated diagnosis protocols include measurements of Thoracic Outlet Syndrome (TOS), diagnosis of Raynaud’s Phenomenon, evaluation of Penile Function or Erectile Dysfunction, assessment of Allen’s Test (or Palmar Arch Test), measurements of Venous Reflux and Venous Capacitance and Outflow, Pulse Wave Velocity, and more.

Advanced Reporting

The famous Falcon user-friendly report builder tool allows you to design your own report layout easily. Then, add your institute/clinic logo and details to create a detailed and impressive diagnosis report that meets your institute standards. Save a lot of time by building your report with preconfigured interpretation templates.

Advanced Research Options

The Falcon vascular research machine is famous for its built-in statistics tool with on-screen graphs, segments filtering, and Excel tool, which are all designed to simplify the work of vascular and physiological researchers. Export to PDF, Excel, Word, JPEG, VSX, Video clips, and more to support your vascular research and teaching needs, as well as support your clinical vascular publications.
Features
  • Targets the bilateral insula and prefrontal cortexThe H4 Coil stimulates brain structures associated with addiction. 
  • FDA-cleared for smoking addiction treatmentThe H4 Coil was cleared by the FDA to treat smoking addiction in adults. 
  • Integrated sham coilThe helmet includes a sham coil that has similar acoustic artifacts and scalp sensations as the active coil. This helps maintain blinding. 
  • Embedded in a cushioned, cooled helmetThe H-Coils are integrated into a helmet that includes a touchscreen interface, adjustable positioning arm, and foot pedal operation. 
  • Delivers electromagnetic pulsesThe H4 Coil generates electromagnetic pulses that stimulate neurons in the brain. 
  • Reaches deeper and broader brain regionsThe H-Coil design allows for deeper and broader stimulation than traditional TMS coils. 
  • Noninvasive treatmentDeep TMS is a noninvasive treatment that is well-tolerated and doesn't require a significant recovery period. 

Click here to download Brochure

CODE SIZE FINISH
01-01-02 12.8 cm sharp
The BrainsWay Deep TMS H4 Coil is a non-invasive treatment that uses magnetic energy waves to stimulate brain structures associated with addiction and weight loss: 
  • Treatment
    The H4 Coil is used to treat smoking addiction and weight loss. It generates electromagnetic pulses that stimulate the bilateral insula and prefrontal cortex of the brain.
  • Benefits
    Deep TMS is a well-tolerated treatment that can be integrated into a patient's daily schedule. It's said to have no side effects and no recovery period. Patients may start to feel relief from symptoms within a few weeks.
  • Technology
    The H4 Coil is part of a helmet that contains BrainsWay's patented H-Coils, which are designed to stimulate deeper and broader areas of the brain than traditional TMS coils. The helmet also has a touchscreen interface, adjustable positioning arm, and cooling system.
  • Safety
    The H4 Coil has lower rates of headache, treatment site discomfort, and jaw pain than other coils, but higher rates of general discomfort

Click here to download Brochure

This machines have been developed from the well-proven Series 5A and 5B ECT apparatus. The series 6+ models incorporate all the features of the corresponding Series 5B versions. Experience has shown that a very few patients sometimes require higher dosage than was available with the earlier machines and the opportunity was therefore taken to produce equipment with a second, higher, output range. Features: Constant Current stimulus Delivered Dosage Displayed Patient Dynamic Impedance Indicator Simple Single Dose Control Technical Specification: Input Supply: AC 100-120, 210-240 V 40/60 Hz Load: 70 W Apparatus Size: 305 x 170 x 105mm (12” x 6.5” x 4”) Weight: 3.24kg Low Range: 50-700mC @ 750mA High Range: 200-100mC @ 900mA Contents: Two-hand headpiece: 1 C.S lead: 1 Disposable electrodes: 50 Mains cable: 1 Operating & service manual: 1 Removable stand: 1  
Click Here To Download Catalogue
WeightN/AN/AN/AN/AN/AN/A