BUFFERED FORMALIN 10% UNTINTED

$0.00

Shipped From Abroad

Available in 500mL 2Litre and 20L

Contains Formaldehyde 3.6% and phosphate buffer to pH 7.

Actions Buffered Formalin 10% has preservative properties.

Indications Buffered Formalin 10% is used for the preservation of pathological specimens but is not suitable for preserving urine for subsequent examination.

Precautions Not to be taken.

Description

Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
SF103356013099-22
Brands:: PharmAust

Description

Product Description

Contains Formaldehyde 3.6% and phosphate buffer to pH 7.

Actions Buffered Formalin 10% has preservative properties.

Indications Buffered Formalin 10% is used for the preservation of pathological specimens but is not suitable for preserving urine for subsequent examination.

Precautions Not to be taken.

Safety Directions Avoid contact with eyes and skin. Avoid breathing vapour.

Adverse Effects Repeated contact with formaldehyde solutions may induce contact dermatitis. Ingestion results in pain, inflammation, ulceration and necrosis of the mucous membranes.

Directions for Use  Use as indicated in the appropriate preservation techniques.

Poisoning For advice, contact a Poisons Information Centre (Australia 13 11 26) or a doctor. If swallowed, do not induce vomiting; give water, milk or charcoal. If in eyes, hold eyelids apart and flush the eye with continuously running water. Continue flushing until advised to stop by the Poisons Information Centre or doctor, or for at least 15 minutes. If skin or hair contact occurs, remove contaminated clothing and flush skin and hair with running water. If inhaled, remove from contaminated area. Apply artificial respiration if not breathing.

Storage Store above 15oC and below 30oC. Store out of direct sunlight.

Poison Schedule Classified as a Poison (Schedule 6) using the criteria in the Standard Uniform Schedule for Medicines and Poisons

Available in 500mL 2Litre and 20L

Reviews

There are no reviews yet.

Be the first to review “BUFFERED FORMALIN 10% UNTINTED”

Your email address will not be published. Required fields are marked *

Quick Comparison

SettingsBUFFERED FORMALIN 10% UNTINTED removeAlcohol Pad Per Pack removeiSED Fully Automated ESR Analyzer removeAvalun LabPad Device removeEppendorf Pipette Tip 200ul Per Pack removeAGD Erma EL-120 ELectrolyte Analyzer remove
NameBUFFERED FORMALIN 10% UNTINTED removeAlcohol Pad Per Pack removeiSED Fully Automated ESR Analyzer removeAvalun LabPad Device removeEppendorf Pipette Tip 200ul Per Pack removeAGD Erma EL-120 ELectrolyte Analyzer remove
ImageAvalun Labpad machineEppendorf Pipette Tip 200ul Per Pack
SKUSF103356013099-22SF1033560084-64SF1033560084-129SF1033560084-65SF1033560084-137SF1033560084-125
Rating
Price

$0.00

$4.25

$0.00

$0.00

$0.00

$1,320.00

Stock
Availability
Add to cart

DescriptionShipped From Abroad Available in 500mL 2Litre and 20L Contains Formaldehyde 3.6% and phosphate buffer to pH 7. Actions Buffered Formalin 10% has preservative properties. Indications Buffered Formalin 10% is used for the preservation of pathological specimens but is not suitable for preserving urine for subsequent examination. Precautions Not to be taken. Description
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock Alcohol Pad (70% Isopropyl Alcohol Pre Pad, Alcohol Cleansing Swab). Clean the required area. Discard after single use. Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.In stock
The technical innovation of the iSED® fully-automated ESR analyzer consists of directly measuring the intensity of the red cell aggregation which is responsible for Erythrocyte Sedimentation Rate (ESR). Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock The coagulometer, LabPad® INR, measures blood coagulation time thanks to a patented optical technology. This portable In-Vitro Diagnostics (IVD) device works with the Tsmart® INR single-use microcuvettes. Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.In stock
  • Made of high quality PP material with good transparency.
  • Applied for Gilson/Finland/Eppendorf Pipettors.
  • Carefully inspect of raw material and manufactured under strict process check, all tips are with excellent accuracy and precison.
  • Special siliconizing on the inner surface ensure no liquid adhesion and accurate sample transfer.
  • Standard tips and filter tips can be autoclaved, high temperature sterilization acceptable.
Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad
Electrolyte Analyzer ERMA EL-120 is ideal for medium to high volume Laboratories and Hospitals . It offers reliable, automated samples handling and work flow offences . It also allows measurement of specific ions, accurately and precisely . This supports fast diagnosis of critically ill patients and reduces the risks of patient discomfort associated with repeated sampling Precise & Accurate Results Economical to use Large Touchscreen Display with Graphical User Interface. Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Content
Product Description
Contains Formaldehyde 3.6% and phosphate buffer to pH 7. Actions Buffered Formalin 10% has preservative properties. Indications Buffered Formalin 10% is used for the preservation of pathological specimens but is not suitable for preserving urine for subsequent examination. Precautions Not to be taken. Safety Directions Avoid contact with eyes and skin. Avoid breathing vapour. Adverse Effects Repeated contact with formaldehyde solutions may induce contact dermatitis. Ingestion results in pain, inflammation, ulceration and necrosis of the mucous membranes. Directions for Use  Use as indicated in the appropriate preservation techniques. Poisoning For advice, contact a Poisons Information Centre (Australia 13 11 26) or a doctor. If swallowed, do not induce vomiting; give water, milk or charcoal. If in eyes, hold eyelids apart and flush the eye with continuously running water. Continue flushing until advised to stop by the Poisons Information Centre or doctor, or for at least 15 minutes. If skin or hair contact occurs, remove contaminated clothing and flush skin and hair with running water. If inhaled, remove from contaminated area. Apply artificial respiration if not breathing. Storage Store above 15oC and below 30oC. Store out of direct sunlight. Poison Schedule Classified as a Poison (Schedule 6) using the criteria in the Standard Uniform Schedule for Medicines and Poisons Available in 500mL 2Litre and 20L
Alcohol Pad (70% Isopropyl Alcohol Pre Pad, Alcohol Cleansing Swab). Clean the required area. Discard after single use. Size and packing of Medical Alcohol pad:
  • Pad Size: Unfolded: 30 x 60 mm (other size can be request ).
  • Folded: 30x30 mm, 30 x 35mm,can be 2ply or 4ply ( other size, ply can be request ).
  • Aluminum Package: 60 x 50 mm , 50 x 50mm approximate ( other size can be request ).
  • Packing: 100/200 pcs per inner box, 50/ 100 boxes per carton(packing can be request).
Use of Medical Alcohol pad:
  • For cleaning prior to injection or to disinfect the hurted skin for family and medical treatment organization use.
  • For preparation and immediate disinfection of skin, wound area orr Instrument and utensil.
Notice of Medical Alcohol pad:
  • Not for eyes;
  • keep out of reach of children;
  • For external use only;
  • please stop using if you feel allergic or amyctic
Materials - Non-Woven Fabric
Trademark - OEM/ODM
Specification - CE&ISO13485
   
The technical innovation of the iSED® fully-automated ESR analyzer consists of directly measuring the intensity of the red cell aggregation which is responsible for Erythrocyte Sedimentation Rate (ESR). Unlike traditional ESR methodologies that measure the aggregation of the red blood cells indirectly, the iSED measures it directly and expresses the values in mm/hr. Features:
  • Results in 20 Seconds

  • 100µL sample drawn directly from primary EDTA tube

  • Fully automated, walk-away operation

  • Random access

  • Positive patient identification via internal barcode reader

  • Compatible with pediatric tube

     
Technical Specifications: 
Principle of Measure: Photometrical
Results: “Printed mm/hr, Range from 1-130 mm/hr”
Sample Requirements: 500uL whole blood, collected in EDTA anti-coagulant tested 24 hours from venipuncture at room temperature or refrigerated.
Tube Requirements: 13 x 75 mm, pierceable capped tube
Quality Control: Barcoded Seditrol® QC
Barcode Reader: Internal
Printer: Internal
Interface Specifications: serial RS232 port for LIS connection
Weight: 14 kg
Dimensions (H x W x D): 36 x 27 x 34 (cm) /14.3 x 10.5 x13.4 (in)
Voltage: 100-240VAC
Frequency Range: 50-60 Hz
Power: 160W
Click Here To Download Catalogue
The coagulometer, LabPad® INR, measures blood coagulation time thanks to a patented optical technology. This portable In-Vitro Diagnostics (IVD) device works with the Tsmart® INR single-use microcuvettes.
  • User-friendly: the LabPad® INR is designed to be easy to use especially thanks to its 3D-shaped microcuvette that only requires a small drop of blood from a fingertip. Thanks to the color screen, both measurement steps and browsing the list of results are easy to visualize.
  • Quick and reliable: the reliability of INR results is obtained by quality controls that are performed automatically before each measurement. In less than one minute, you can see if you are in your therapeutic range.
  • Connected: the result obtained after performing the test can be transferred to healthcare professionals in charge of your treatment monitoring. This result is complementary to the pie charts and trend reports directly displayed on the LabPad® INR to help you monitoring your treatment
 
Click Here To Download Catalogue
   
  • Made of high quality PP material with good transparency.
  • Applied for Gilson/Finland/Eppendorf Pipettors.
  • Carefully inspect of raw material and manufactured under strict process check, all tips are with excellent accuracy and precison.
  • Special siliconizing on the inner surface ensure no liquid adhesion and accurate sample transfer.
  • Standard tips and filter tips can be autoclaved, high temperature sterilization acceptable.
  Classification: PIPETTE Brand Name: Vchanslab,Yingmed,OEM Model Number: YM-K7028 Place of Origin: China Product name: Pipette Tips Material: Polypropylene Certificate: CE/ISO13485/FDA Color: Natural, Blue, Yellow Application: Laboratory, Teaching, Hospital
Electrolyte Analyzer ERMA EL-120 is ideal for medium to high volume Laboratories and Hospitals . It offers reliable, automated samples handling and work flow offences . It also allows measurement of specific ions, accurately and precisely . This supports fast diagnosis of critically ill patients and reduces the risks of patient discomfort associated with repeated sampling Precise & Accurate Results Economical to use Large Touchscreen Display with Graphical User Interface. Features:
  • Parameters: Na+,K+,Cl-, iCa++ / Li
  • It works on ISE principle
  • Sample Type: Whole blood, Serum, Plasma, Urine
  • Low reagent consumption
  • Sample requirement is only 90ul
  • 60 samples per hour
  • Automatic two point calibration after 4hrs and one point calibration with each sample analysis
  • Air bubble detection
  • Track reagents consumption and provides alerts
  • For low reagent volume
  • Precision testing facility to get CV and SD
  • Trilevel Quality Control with LJ plots of last 30days
  • Low aspiration volume
  • Fast sample processing
  • Accurate and Precise results
Technical Specifications:
Parameters Na+, K+, Cl– /Ca++
Principle Ion Selective Electrode (ISE)
Sample Type Analyses whole blood, serum, plasma and urine
Sample Volume ≤100 µL
Analysis Time ≤60 seconds
Throughout ≤60 samples per hour
Data Link Serial (RS232)
External Interface USB (Keyboard, Mouse)
Operating Condition 10° C to 35° C, Relative Humidity up to 85%
Storage Condition Temp: 10° C to 40° C
Relative Humidity up to 85% non- condensing
Power Supply 100 to 240 VAC ±10%, 50Hz
Dimensions 395 x 260 x 375 mm
Weight 7.5 kg
 
Click Here To Download Catalogue
WeightN/AN/AN/AN/AN/AN/A
DimensionsN/AN/AN/AN/AN/AN/A
Additional information
Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • Rating
  • Price
  • Description
Click outside to hide the comparison bar
Compare