Cleveland Open Cup Flash Point Tester PE-TVO

Ask for Price$0.00

Shipped From Abroad

Purpose:
The tester PE-TVO is intended for usage as laboratory equipment to perform open cup flash point determination of oil products according to method A ASTM D92 and GOST 4333-87.

Delivery & Availability:
Typically 14-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.

SF1033560106
Brands:: ECROSKHIM

Description

Purpose:
The tester PE-TVO is intended for usage as laboratory equipment to perform open cup flash point determination of oil products according to method A ASTM D92 and GOST 4333-87.

Technical specifications:
– Maximum heating temperature, °C – up to 370
– Power supply voltage from AC mains with frequency of 50Hz, V – 220±22
– Power consumption, no higher than, W – 1000
– Instrument weight, kg – 5
– Service life, years at least – 5

Operation conditions:
– Air temperature, °C – 15?35
– Relative humidity, % – 30?90
– Overall dimensions (body), mm:
– Length, mm – 330
– Width, mm – 250
– Height, mm – 165
– Range of flash point determination, °C – 25-370
– Ignition device, type  – gas
– Control of electric heating power – electronic
– Automatic passage of burner above surface of sample at set speed
– Availability of gas network or cylinder (methane, propane/butane) is required

Scope of delivery:
1. The open cup flash point tester PE-TVO complete with cup – 1 pc.
2. Thermometer TH-2 according to GOST 400 – 1 pc.
3. Template for flame adjustment – 1 pc.
4. Operation manual- 1 pc.
5. Packaging crate – 1 pc.

Reviews

There are no reviews yet.

Be the first to review “Cleveland Open Cup Flash Point Tester PE-TVO”

Your email address will not be published. Required fields are marked *

Quick Comparison

SettingsCleveland Open Cup Flash Point Tester PE-TVO removeSugentech Inclix (POCT) Immunoassay Analyzer removeEppendorf Minispin Centrifuge removeHawksley 1400 Haematocrit Centrifuge removeDiscover 5 Panel Cup with Adulterants Per Pack removeIISM VPism-C (Compact Type) Vein Probe remove
NameCleveland Open Cup Flash Point Tester PE-TVO removeSugentech Inclix (POCT) Immunoassay Analyzer removeEppendorf Minispin Centrifuge removeHawksley 1400 Haematocrit Centrifuge removeDiscover 5 Panel Cup with Adulterants Per Pack removeIISM VPism-C (Compact Type) Vein Probe remove
ImageDrug Test CupIISM VPism-C (Compact Type) Vein Probe
SKUSF1033560106SF1033560084-89SF1033560084-116SF1033560084-118SF1033560084-23SF1033560090-1
Rating
Price

Ask for Price$0.00

Ask for Price$0.00

Ask for Price$0.00

$690.00

Ask for Price$0.00

Ask for Price$0.00

Stock
Availability
Add to cart

DescriptionShipped From Abroad
Purpose: The tester PE-TVO is intended for usage as laboratory equipment to perform open cup flash point determination of oil products according to method A ASTM D92 and GOST 4333-87. Delivery & Availability: Typically 14-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock INCLIX™ is an immunochromatographic analyzer providing immediate point-of-care testing (POCT) at patient care settings or clinical laboratories. It facilitates automatic detection of various biomarkers for cardiovascular disease, infectious disease, cancer, diabetes, allergy, and etc. with high accuracy and sensitivity. INCLIX™ analyzer is a compact, easy-to-use and cost-effective multi-parameter POCT instrument and its unique user friendly software provides an efficient data management system. Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.In stock
Powerful and user-friendly MiniSpin Centrifuge are small enough so that each workstation can be equipped with a “personal” centrifuge. The rotor, inner centrifuge lid, and lid latch are made of metal for maximum operation safety. Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock
The Hawksley Haematospin 1400 Centrifuges are built in the UK and are made from durable and high-quality components. These centrifuges are ideal for veterinary laboratories and practices specifically designed to produce reliable and accurate results on blood and urine. One of the main features of this centrifuge is that it takes both 2ml microtubes and 75mm microhaematocrits. The classic design of these centrifuges is used worldwide with guaranteed support for all servicing and parts. Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock
The Discover Cup is an all-in-one drug of abuse test cup. The strips are self-contained and the entire cup is tamper resistant. Delivery & Availability:
Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped from Abroad The iiSM VPism-C Vein Probe - Compact Unit is a compact, non-invasive infrared device to view blood vessels just beneath the skin. Includes a camera, touchscreen display, connector cable, power supply, camera stand, gooseneck arm, and instruction manual. Delivery & Availability: Typically 10 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Content

Purpose: The tester PE-TVO is intended for usage as laboratory equipment to perform open cup flash point determination of oil products according to method A ASTM D92 and GOST 4333-87.

Technical specifications: - Maximum heating temperature, °C - up to 370 - Power supply voltage from AC mains with frequency of 50Hz, V - 220±22 - Power consumption, no higher than, W - 1000 - Instrument weight, kg – 5 - Service life, years at least – 5

Operation conditions: - Air temperature, °C - 15?35 - Relative humidity, % - 30?90 - Overall dimensions (body), mm: - Length, mm - 330 - Width, mm - 250 - Height, mm - 165 - Range of flash point determination, °C - 25-370 - Ignition device, type  - gas - Control of electric heating power – electronic - Automatic passage of burner above surface of sample at set speed - Availability of gas network or cylinder (methane, propane/butane) is required

Scope of delivery: 1. The open cup flash point tester PE-TVO complete with cup - 1 pc. 2. Thermometer TH-2 according to GOST 400 – 1 pc. 3. Template for flame adjustment – 1 pc. 4. Operation manual- 1 pc. 5. Packaging crate – 1 pc.

INCLIX™ is an immunochromatographic analyzer providing immediate point-of-care testing (POCT) at patient care settings or clinical laboratories. It facilitates automatic detection of various biomarkers for cardiovascular disease, infectious disease, cancer, diabetes, allergy, and etc. with high accuracy and sensitivity. INCLIX™ analyzer is a compact, easy-to-use and cost-effective multi-parameter POCT instrument and its unique user friendly software provides an efficient data management system. Features: • Good accuracy owning to superior CMOS sensor & our own Algorism • 10,000 test results data storage • Instrument Check by Reference Kit • Remote Support available (when connected via Internet) • Built-in Thermal Printer and Barcode Scanner • Data export to USB(PDF, Excel), Email and LIS • Storage Temperature of Test Cassette & Buffer : Room temperature, 2 ~ 30 ℃ • Shelf Life of Test Cassette & Buffer : 24 months  
Click Here To Download Catalogue
 
Powerful and user-friendly MiniSpin Centrifuge are small enough so that each workstation can be equipped with a “personal” centrifuge. The rotor, inner centrifuge lid, and lid latch are made of metal for maximum operation safety. Features:
  • Rotor capacity: 12 x 1.5/2.0 mL vessels, 2 x PCR strip
  • Max. speed: 14,100 x g (14,500 rpm)
  • Extremely compact footprint — measures 9”W x 4.”H x 9ó”D!
  • Aluminum rotor accommodates twelve 1.5- or 2.0-mL tubes (maximum diameter of 11 mm)
  • Rotor can be autoclaved at 121°C for 20 minutes
  • Minimal sample heat transfer — maximum of 12°C after 20 minutes at max speed
  • Eliminate costly repairs with the low maintenance drive
  • Soft-touch lid closure for ergonomic lid locking — and releases automatically at the end of a run
Technical Specifications:
Speed: 800 – 13,400 rpm (100 rpm steps)
Capacity: 12 x 1.5/2.0 mL
Electrical: 120 V, 60 Hz
Dimensions: (W x D x H) 22.6 x 23.9 x 12.0 cm
Weight: 4.3 kg
 
Click Here To Download Catalogue
The Hawksley Haematospin 1400 Centrifuges are built in the UK and are made from durable and high-quality components. These centrifuges are ideal for veterinary laboratories and practices specifically designed to produce reliable and accurate results on blood and urine. One of the main features of this centrifuge is that it takes both 2ml microtubes and 75mm microhaematocrits. The classic design of these centrifuges is used worldwide with guaranteed support for all servicing and parts. Technical specifications:
  • Speed: 11,800rpm with 24- place rotor
  • RCF: 14,000g with 24-place rotor
  • Acceleration: 0-11,800rpm in 60 seconds, with 24-place rotor
  • Brake: Automatic
  • Noise: 62dB running with 24-place rotor
  • Motor: High precision AC/DC series wound motor, brush gear, computer wound coil winding, balance armature and high speed bearings.
  • Timer: 0-15 minute timer, graduated in 1 minute increments. Automatic switch at zero
  • Weight: 5.1Kg net (without rotor)
  • Dimensions: 23.5cm height x 27cm diameter, footprint 16cm diameter
  • Construction: Aluminium casing with a steel lid
  • Finish: Body cream white baked enamel, with matt black baked enamel lid
 
Click Here To Download Catalogue
All-in-One Design
FDA 510K & CLIA Waived 99% Accurate Results in as little as 1 minute 24 Month Shelf Life from Date of Manufacture Secure, seal and send to lab for confirmation Built in temperature strip Available to test up to 14 substances Adulterants available
 
 
The iiSM VPism-C Vein Probe - Compact Unit is a compact, non-invasive infrared device to view blood vessels just beneath the skin. Includes a camera, touchscreen display, connector cable, power supply, camera stand, gooseneck arm, and instruction manual. This handheld, portable device is lightweight and includes the touchscreen and camera with attached clip. The camera can be removed and handled by hand, or can clip to the touchscreen unit for a hands-free experience. The back of the device also has a kickstand, so that physicians can stand the device on its own. The VPism-C can also be mounted to an armrest, if a patient needs to be stationary, or attached to a SLism-F Specialized Light Source for patients with deeper vessels. This device can be a vital tool in providing accurate placement of injections or other vascular treatments, such as for varicose veins. The infrared video shows the location of the veins and capillaries in real time, as well as save images for further discussion or diagnosis. For patients who have difficult-to-find veins, this device will save them from incorrect or painful injection sites. Features: Probe Target: Subcutaneous blood vessels of various patients (including capillaries) Probe Method: Non-invasive infrared technology Probe Depth: Within 10 mm under the skin Magnification Function: Up to 1X, 2X and 4X Automatic Adjustment Function: Adjusts the brightness automatically based on the targeted vein Specialized Light Function: Shows the veins more clearly by using the specialized light source Operation Method: Easy to operate with touchscreen Internal Battery Support: Continuous running time: 1.5 hours Warranty: 1 year
Click Here To Download Catalogue
 
WeightN/AN/AN/AN/AN/AN/A
DimensionsN/AN/AN/AN/AN/AN/A
Additional information
Model

Advanced, Advanced Plus, Basic, Smart

Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • Rating
  • Price
  • Description
Click outside to hide the comparison bar
Compare