Cleveland Open Cup Flash Point Tester PE-TVO

$0.00

Shipped From Abroad

Purpose:
The tester PE-TVO is intended for usage as laboratory equipment to perform open cup flash point determination of oil products according to method A ASTM D92 and GOST 4333-87.

Delivery & Availability:
Typically 14-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.

SF1033560106
Brands:: ECROSKHIM

Description

Purpose:
The tester PE-TVO is intended for usage as laboratory equipment to perform open cup flash point determination of oil products according to method A ASTM D92 and GOST 4333-87.

Technical specifications:
– Maximum heating temperature, °C – up to 370
– Power supply voltage from AC mains with frequency of 50Hz, V – 220±22
– Power consumption, no higher than, W – 1000
– Instrument weight, kg – 5
– Service life, years at least – 5

Operation conditions:
– Air temperature, °C – 15?35
– Relative humidity, % – 30?90
– Overall dimensions (body), mm:
– Length, mm – 330
– Width, mm – 250
– Height, mm – 165
– Range of flash point determination, °C – 25-370
– Ignition device, type  – gas
– Control of electric heating power – electronic
– Automatic passage of burner above surface of sample at set speed
– Availability of gas network or cylinder (methane, propane/butane) is required

Scope of delivery:
1. The open cup flash point tester PE-TVO complete with cup – 1 pc.
2. Thermometer TH-2 according to GOST 400 – 1 pc.
3. Template for flame adjustment – 1 pc.
4. Operation manual- 1 pc.
5. Packaging crate – 1 pc.

Reviews

There are no reviews yet.

Be the first to review “Cleveland Open Cup Flash Point Tester PE-TVO”

Your email address will not be published. Required fields are marked *

Quick Comparison

SettingsCleveland Open Cup Flash Point Tester PE-TVO removeLittle Sister Table Top Autoclave removeErma B-111 Bilirubin Meter removeAvalun LabPad Device removeiSED Fully Automated ESR Analyzer removeDiscover 5 Panel Cup with Adulterants Per Pack remove
NameCleveland Open Cup Flash Point Tester PE-TVO removeLittle Sister Table Top Autoclave removeErma B-111 Bilirubin Meter removeAvalun LabPad Device removeiSED Fully Automated ESR Analyzer removeDiscover 5 Panel Cup with Adulterants Per Pack remove
ImageAvalun Labpad machineDrug Test Cup
SKUSF1033560106SF1033560084-46SF1033560084-6SF1033560084-65SF1033560084-129SF1033560084-23
Rating
Price

$0.00

$1,350.00

$715.00

$0.00

$0.00

$0.00

Stock
Availability
Add to cart

DescriptionShipped From Abroad
Purpose: The tester PE-TVO is intended for usage as laboratory equipment to perform open cup flash point determination of oil products according to method A ASTM D92 and GOST 4333-87. Delivery & Availability: Typically 14-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Out stock Little Sister Table Top Autoclave: This sterilizer is a table type in safety and auto controlled,which is designed for the unit of medical health, pharmacy, science and technology and mostly suitable for sterilizing of surgical,dental and eye instruments, glassware medicine, culture medium and biological dressing, food and other goods. Delivery & Availability: Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.Shipped From Aboard  The advanced B111 Bilirubinmeter provides fast, accurate results for Total bilirubin level in neonates with only 40μl serum or plasma sample. It determines total bilirubin by dual wavelength photometric analysis. Suited for pediatric setups, small workload labs & hospitals because of its compact and portable design. Advanced, benchtop and precise instrument for measuring Total Bilirubin.

Delivery & Availability:

Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock The coagulometer, LabPad® INR, measures blood coagulation time thanks to a patented optical technology. This portable In-Vitro Diagnostics (IVD) device works with the Tsmart® INR single-use microcuvettes. Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.In stock
The technical innovation of the iSED® fully-automated ESR analyzer consists of directly measuring the intensity of the red cell aggregation which is responsible for Erythrocyte Sedimentation Rate (ESR). Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock
The Discover Cup is an all-in-one drug of abuse test cup. The strips are self-contained and the entire cup is tamper resistant. Delivery & Availability:
Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Content

Purpose: The tester PE-TVO is intended for usage as laboratory equipment to perform open cup flash point determination of oil products according to method A ASTM D92 and GOST 4333-87.

Technical specifications: - Maximum heating temperature, °C - up to 370 - Power supply voltage from AC mains with frequency of 50Hz, V - 220±22 - Power consumption, no higher than, W - 1000 - Instrument weight, kg – 5 - Service life, years at least – 5

Operation conditions: - Air temperature, °C - 15?35 - Relative humidity, % - 30?90 - Overall dimensions (body), mm: - Length, mm - 330 - Width, mm - 250 - Height, mm - 165 - Range of flash point determination, °C - 25-370 - Ignition device, type  - gas - Control of electric heating power – electronic - Automatic passage of burner above surface of sample at set speed - Availability of gas network or cylinder (methane, propane/butane) is required

Scope of delivery: 1. The open cup flash point tester PE-TVO complete with cup - 1 pc. 2. Thermometer TH-2 according to GOST 400 – 1 pc. 3. Template for flame adjustment – 1 pc. 4. Operation manual- 1 pc. 5. Packaging crate – 1 pc.

Little Sister Table Top Autoclave: This sterilizer is a table type in safety and auto controlled,which is designed for the unit of medical health, pharmacy, science and technology and mostly suitable for sterilizing of surgical,dental and eye instruments, glassware medicine, culture medium and biological dressing, food and other goods. Features:
  • Indicator light indicates working state.
  • For 4~6 minutes rapidly sterilizing.
  • Sterilizing temperature and time can be preset.
  • Steam-water inner circulation system: no steam discharge, and the environment for sterilizing will be clean and dry.
  • Over temperature & over pressure auto-protection.
  • Safe protection of water lacking.
  • Exhaust the cool air automatically.
  • With three stainless steel sterilizing plates.
  • The chamber of the sterilizer is made of stainless steel.
  • Automatically shut off with beep reminding after sterilization.
Technical Specifications:
   MODEL   MC-XB20J MC-XB24J

Sterilizing chamber volume

20L(φ250×420 mm) 24L(φ250×520 mm)
Maximum working pressure 0.22Mpa
Maximum working temperature 134℃
Adjustment of temperature 105-134℃
Timer 0-60 min
Chamber temperature equal ≤ ± 1℃
Source power 1.5KW/AC 220V 50Hz (AC110V 60HZ)
Sterilizing plate 340×200×30 mm (3 piece) 400×200×30 mm (3 piece)
Dimension 480×480×384 mm 580×480×384 mm
Package dimension 700×580×500 mm 800×580×500 mm
 G. W/N.W 44/40 kg

50/45 kg

   
 
 
The advanced B111 Bilirubinmeter provides fast, accurate results for Total bilirubin level in neonates with only 40μl serum or plasma sample. It determines total bilirubin by dual wavelength photometric analysis. Suited for pediatric setups, small workload labs & hospitals because of its compact and portable design. Advanced, benchtop and precise instrument for measuring Total Bilirubin. Feature
  • Auto zero function: Manual blanking not required
  • Dual wavelength measurement system:
  • 2 wave lengths 455nm and 575nm
  • Plays major role to remove the interference caused due to Hemolysis & turbidity of sample
  • LED Light source:
  • LED does not require replacement as it lasts longer
  • As compared to Lamp, LED are more suitable as there is no intensity fluctuations
  • No warm up time required.
  • Flexible unit selection:
  • Two units either mg/dl or umol/L are selectable, ease of reporting
  • Compact slot for Capillary:
  • Accuracy of results are directly related to proper alignment of Capillary
  • B-111 has the easiest mode to ensure precise values
  • Data transfer:
  • External device can be connected to instrument through RS232 por
  • USB port
Technical Specification
  • Light source - LED
  • Wavelength - 455nm and 575nm
  • Net weight - 1kg
  • Measuring range - 0-30 mg/dl , 510 umol/L
  • Display - 16×2 LCD module with backlight
  • Auto calibration - Yes
  • Sample type - Serum or plasma
  • Sample volume - 40-80μL
  • Test time - <5sec
  • Units - mg/dl or umol/L
  • Dimensions - 150 (W) × 115 (H) × 190 (D) mm
  • Interface - RS232
  • Reading cuvette - Heparinized micro capillary holder
  • Storage temperature - 15-40°c
  • Power supply - DC 9V(DC adapter)
  • Power consumption - <2W
The coagulometer, LabPad® INR, measures blood coagulation time thanks to a patented optical technology. This portable In-Vitro Diagnostics (IVD) device works with the Tsmart® INR single-use microcuvettes.
  • User-friendly: the LabPad® INR is designed to be easy to use especially thanks to its 3D-shaped microcuvette that only requires a small drop of blood from a fingertip. Thanks to the color screen, both measurement steps and browsing the list of results are easy to visualize.
  • Quick and reliable: the reliability of INR results is obtained by quality controls that are performed automatically before each measurement. In less than one minute, you can see if you are in your therapeutic range.
  • Connected: the result obtained after performing the test can be transferred to healthcare professionals in charge of your treatment monitoring. This result is complementary to the pie charts and trend reports directly displayed on the LabPad® INR to help you monitoring your treatment
 
Click Here To Download Catalogue
   
The technical innovation of the iSED® fully-automated ESR analyzer consists of directly measuring the intensity of the red cell aggregation which is responsible for Erythrocyte Sedimentation Rate (ESR). Unlike traditional ESR methodologies that measure the aggregation of the red blood cells indirectly, the iSED measures it directly and expresses the values in mm/hr. Features:
  • Results in 20 Seconds

  • 100µL sample drawn directly from primary EDTA tube

  • Fully automated, walk-away operation

  • Random access

  • Positive patient identification via internal barcode reader

  • Compatible with pediatric tube

     
Technical Specifications: 
Principle of Measure: Photometrical
Results: “Printed mm/hr, Range from 1-130 mm/hr”
Sample Requirements: 500uL whole blood, collected in EDTA anti-coagulant tested 24 hours from venipuncture at room temperature or refrigerated.
Tube Requirements: 13 x 75 mm, pierceable capped tube
Quality Control: Barcoded Seditrol® QC
Barcode Reader: Internal
Printer: Internal
Interface Specifications: serial RS232 port for LIS connection
Weight: 14 kg
Dimensions (H x W x D): 36 x 27 x 34 (cm) /14.3 x 10.5 x13.4 (in)
Voltage: 100-240VAC
Frequency Range: 50-60 Hz
Power: 160W
Click Here To Download Catalogue
All-in-One Design
FDA 510K & CLIA Waived 99% Accurate Results in as little as 1 minute 24 Month Shelf Life from Date of Manufacture Secure, seal and send to lab for confirmation Built in temperature strip Available to test up to 14 substances Adulterants available
 
 
WeightN/AN/AN/AN/AN/AN/A
DimensionsN/AN/AN/AN/AN/AN/A
Additional information
Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • Rating
  • Price
  • Description
Click outside to hide the comparison bar