CO2 Mainstream Module Capno-M+
$0.00
Shipped From Abroad
An original patented product that can be used for both intubated patients and non-intubated patients, breaking through the limitation that mainstream modules can only be used for intubated patients.
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Description
Features of CO2 Mainstream Module Capno-M+
- Patented Products
With its compact design and two kinds of adapters, the mainstream module can be used for intubated patients and non-intubated patients. Breathing light intuitively and qualitatively reacts to real-time concentration.
- High Precision
Careful selection of infrared devices, hardware design and software algorithm, to achieve high signal-to-noise ratio and ensure the measurement accuracy within the temperature range of -5-50°C and the measurement range of 0-20%.
- Suitable For Adults, Children and Newborns
Excellent performance and low cost. Plug and play, the host does not need an internal circuit, but just a serial port. The data can be measured within 4 seconds after power on.
- Automatic Pressure Compensation
There is an atmospheric pressure sensor inside, which is suitable for various altitude ranges. Built-in interference gas compensation algorithm.
- Reliable Carbon Dioxide OEM Solutions
A variety of protocols, so that your products quickly upgrade assembly.
Specifications of CO2 Mainstream Module Capno-M+
Technique | Non-dispersive infrared gas analysis, multi-channel infrared detector, no moving parts |
Storage condition | -40°C to 70°C,<93% RH, non-condensing |
Working condition | 5 to 40℃,10 to 90% RH, non-condensing |
Circumstance pressure | 55-115kP |
Power demand | 5V ± 5% (max ripple 200 mVp-p) |
Power consumption | <150mA |
lnterface | RS-232/Standard E-8-1, 38.4 kBaud,10 ms data interval (KM) or customized communication protocol. |
CO2 measurement range | 0-150 mmHg, 0-20 kPa, 0-19.7% |
CO2 resolution | 0.1mmHg |
co2 measurement accuracy | 0 – 40 mmHg ± 2 mmHg
41 – 70 mmHg ± 5% of reading 71 – 100 mmHg ± 8% of reading 101 – 150 mmHg ± 10% of reading |
Respiration rate | 3-150 bpm |
Respiration rate accuracy | ±1% of reading or ±1 rpm whichever is greater |
Anesthetic gas compensation | N2O, O2, Agent (HOST supplied) |
Barometric Pressure | Barometric Pressure 400 to 860 mm Hg automatic |
Warm-up time | To reach designed deviation 97% within 8s, to reach designed deviation within 20s. |
Rise time | About 70ms |
CO2 Stability | Shortly drifting: drifting less than 1 mmHg, after 4 hours’ power on. Long drifting: drifting does not influence nominal accuracy after continu hous 140 hours’power on |
Calibration | No routine user calibration required |
Zero | proceeding when replacing adaptor |
EtCO2 calcualtion | every breath, or 10 or 20 seconds averagely |
Application Scenarios of CO2 Mainstream Module Capno-M+
- Innovative Patented Products
Capno-M+ is an innovative carbon dioxide module independently developed by Kingst, which can be used for both intubated and non-intubated patients. It breaks through the limit that the mainstream modules can only be used for intubated patients in the past.
- High Accuracy
It is equipped with a high-quality Infrared device, hardware design, and software algorithm to achieve gas concentration measurement with a high signal-to-noise ratio;
- Low Consumption and Easy to use
A variety of adapters for adults, children and newborns, cost-effective, reduce the cost of use;
- Plug and Play,
No circuit is required inside the host, only one serial port is needed, and the data can be measured within 4 seconds after power-on;
- Automatic Pressure Compensation
There is an internal atmospheric pressure sensor, suitable for various altitude ranges, and a built-in interference gas compensation algorithm;
- OEM Solution
Reliable CO2 OEM solution, compatible with multiple protocols, enabling you to quickly upgrade your product.
Quick Comparison
Settings | CO2 Mainstream Module Capno-M+ remove | Render SD-M2000A(P) Transport/Portable Anesthetic Machine remove | Littman Stethoscope remove | Agary I.V. Cannula remove | Siare Morpheus M Anaesthetic Machine remove | CryoIQ CIQ-DP-L- Cryo DERM Plus Liquid Device with LED Light (CiQ-A-LED) remove | ||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Name | CO2 Mainstream Module Capno-M+ remove | Render SD-M2000A(P) Transport/Portable Anesthetic Machine remove | Littman Stethoscope remove | Agary I.V. Cannula remove | Siare Morpheus M Anaesthetic Machine remove | CryoIQ CIQ-DP-L- Cryo DERM Plus Liquid Device with LED Light (CiQ-A-LED) remove | ||||||||||||||||||||||||||||||||||||||||
Image | ![]() | ![]() | ![]() | ![]() | ![]() | ![]() | ||||||||||||||||||||||||||||||||||||||||
SKU | SF1033560011-12 | SF1033560084-5 | SF1033560084-221 | SF1033560101-2 | SF1033560096-4 | |||||||||||||||||||||||||||||||||||||||||
Rating | ||||||||||||||||||||||||||||||||||||||||||||||
Price |
| $1,320.00 | $13.20 | $7.10 |
|
| ||||||||||||||||||||||||||||||||||||||||
Stock | ||||||||||||||||||||||||||||||||||||||||||||||
Availability | ||||||||||||||||||||||||||||||||||||||||||||||
Add to cart | ||||||||||||||||||||||||||||||||||||||||||||||
Description | Shipped From Abroad
An original patented product that can be used for both intubated patients and non-intubated patients, breaking through the limitation that mainstream modules can only be used for intubated patients.
Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| Shipped from Abroad
| In Stock
Delivery & Availability: Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | In stock
I.V Cannula with wings & injection port 24G/19mm, 0.70mm/20ml/min Injection port with unidirectional valve for facilitating extra medication and preventing back flow. Specially engineered recessed plug with protective ring to avoid risk of contamination. Angle & grooved wings for easy cannulation and to prevent rolling of cannula over patient body. Colour coded cap for easy identification of guage size.
| Shipped from Abroad The MORPHEUS M is an anaesthesia machine and it can be used on adult, children and newborn patients. The MORPHEUS M is suitable for administration of Oxygen – Air – Nitrous Oxide – Halothane – Enflurane – Isoflurane – Sevoflurane – Desflurane mixtures. Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | Shipped from Abroad
CryoIQ device is perfectly fitted for treatment of warts and other common skin lesions. Its unique construction with a built-in non-return valve prevents gas leakage thus giving a maximum use of the gas content. Areas of application are general practice, dermatology, pediatrics, podiatry, aesthetics, veterinary and gynecology/urology.
| ||||||||||||||||||||||||||||||||||||||||
Content | Features of CO2 Mainstream Module Capno-M+
With its compact design and two kinds of adapters, the mainstream module can be used for intubated patients and non-intubated patients. Breathing light intuitively and qualitatively reacts to real-time concentration.
Careful selection of infrared devices, hardware design and software algorithm, to achieve high signal-to-noise ratio and ensure the measurement accuracy within the temperature range of -5-50°C and the measurement range of 0-20%.
Excellent performance and low cost. Plug and play, the host does not need an internal circuit, but just a serial port. The data can be measured within 4 seconds after power on.
There is an atmospheric pressure sensor inside, which is suitable for various altitude ranges. Built-in interference gas compensation algorithm.
A variety of protocols, so that your products quickly upgrade assembly.
Specifications of CO2 Mainstream Module Capno-M+
Application Scenarios of CO2 Mainstream Module Capno-M+
|
Click Here To download Catalogue | Littman Stethoscope Features:
| I.V Cannula with wings & injection port 24G/19mm, 0.70mm/20ml/min Injection port with unidirectional valve for facilitating extra medication and preventing back flow. Specially engineered recessed plug with protective ring to avoid risk of contamination. Angle & grooved wings for easy cannulation and to prevent rolling of cannula over patient body. Colour coded cap for easy identification of guage size. | The MORPHEUS M is an anaesthesia machine and it can be used on adult, children and newborn patients. The MORPHEUS M is suitable for administration of Oxygen – Air – Nitrous Oxide – Halothane – Enflurane – Isoflurane – Sevoflurane – Desflurane mixtures.
Features:
Click Here To Download Catalogue) | CryoIQ device is perfectly fitted for treatment of warts and other common skin lesions. Its unique construction with a built-in non-return valve prevents gas leakage thus giving a maximum use of the gas content. Areas of application are general practice, dermatology, pediatrics, podiatry, aesthetics, veterinary and gynecology/urology. The device uses a state-of-the-art cooling technology that does not require handling of potentially dangerous gases and liquids meaning that the gas cartridge is safely replaced when empty. The device features an ergonomic design where the cooling medium is evenly, accurately and economically distributed by depressing the metering lever.
Features:
| ||||||||||||||||||||||||||||||||||||||||
Weight | N/A | N/A | N/A | N/A | N/A | N/A | ||||||||||||||||||||||||||||||||||||||||
Dimensions | N/A | N/A | N/A | N/A | N/A | N/A | ||||||||||||||||||||||||||||||||||||||||
Additional information |
Reviews
There are no reviews yet.