CO2 Mainstream Module Capno-M+

$0.00

Shipped From Abroad

An original patented product that can be used for both intubated patients and non-intubated patients, breaking through the limitation that mainstream modules can only be used for intubated patients.

Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Brands:: Kingst

Description

Features of CO2 Mainstream Module Capno-M+
  • Patented Products

With its compact design and two kinds of adapters, the mainstream module can be used for intubated patients and non-intubated patients. Breathing light intuitively and qualitatively reacts to real-time concentration.

  • High Precision

Careful selection of infrared devices, hardware design and software algorithm, to achieve high signal-to-noise ratio and ensure the measurement accuracy within the temperature range of -5-50°C and the measurement range of 0-20%.

  • Suitable For Adults, Children and Newborns

Excellent performance and low cost. Plug and play, the host does not need an internal circuit, but just a serial port. The data can be measured within 4 seconds after power on.

  • Automatic Pressure Compensation

There is an atmospheric pressure sensor inside, which is suitable for various altitude ranges. Built-in interference gas compensation algorithm.

  • Reliable Carbon Dioxide OEM Solutions

A variety of protocols, so that your products quickly upgrade assembly.

 

Specifications of CO2 Mainstream Module Capno-M+
Technique Non-dispersive infrared gas analysis, multi-channel infrared detector, no moving parts
Storage condition -40°C to 70°C,<93% RH, non-condensing
Working condition 5 to 40℃,10 to 90% RH, non-condensing
Circumstance pressure 55-115kP
Power demand 5V ± 5% (max ripple 200 mVp-p)
Power consumption <150mA
lnterface RS-232/Standard E-8-1, 38.4 kBaud,10 ms data interval (KM) or customized communication protocol.
CO2 measurement range 0-150 mmHg, 0-20 kPa, 0-19.7%
CO2 resolution 0.1mmHg
co2 measurement accuracy 0 – 40 mmHg ± 2 mmHg

41 – 70 mmHg ± 5% of reading

71 – 100 mmHg ± 8% of reading

101 – 150 mmHg ± 10% of reading

Respiration rate 3-150 bpm
Respiration rate accuracy ±1% of reading or ±1 rpm whichever is greater
Anesthetic gas compensation N2O, O2, Agent (HOST supplied)
Barometric Pressure Barometric Pressure 400 to 860 mm Hg automatic
Warm-up time To reach designed deviation 97% within 8s, to reach designed deviation within 20s.
Rise time About 70ms
CO2 Stability Shortly drifting: drifting less than 1 mmHg, after 4 hours’ power on. Long drifting: drifting does not influence nominal accuracy after continu hous 140 hours’power on
Calibration No routine user calibration required
Zero proceeding when replacing adaptor
EtCO2 calcualtion every breath, or 10 or 20 seconds averagely
Application Scenarios of CO2 Mainstream Module Capno-M+
  • Innovative Patented Products

Capno-M+ is an innovative carbon dioxide module independently developed by Kingst, which can be used for both intubated and non-intubated patients. It breaks through the limit that the mainstream modules can only be used for intubated patients in the past.

  • High Accuracy

It is equipped with a high-quality Infrared device, hardware design, and software algorithm to achieve gas concentration measurement with a high signal-to-noise ratio;

  • Low Consumption and Easy to use

A variety of adapters for adults, children and newborns, cost-effective, reduce the cost of use;

  • Plug and Play,

No circuit is required inside the host, only one serial port is needed, and the data can be measured within 4 seconds after power-on;

  • Automatic Pressure Compensation

There is an internal atmospheric pressure sensor, suitable for various altitude ranges, and a built-in interference gas compensation algorithm;

  • OEM Solution

Reliable CO2 OEM solution, compatible with multiple protocols, enabling you to quickly upgrade your product.

Quick Comparison

SettingsCO2 Mainstream Module Capno-M+ removeLab/Ward Coat removeRender SD-M2000D Anesthetic Machine removeRender SD-M2000B Anesthetic Machine removeSpinal Epidural Pack removeSiare Morpheus E Anaesthetic Machine remove
NameCO2 Mainstream Module Capno-M+ removeLab/Ward Coat removeRender SD-M2000D Anesthetic Machine removeRender SD-M2000B Anesthetic Machine removeSpinal Epidural Pack removeSiare Morpheus E Anaesthetic Machine remove
ImageAnesthetic Machine
SKUSF1033560084-222SF1033560011-15SF1033560011-10SF1033560084-25SF1033560101-1
Price

$0.00

$11.00

$5,940.00

$4,840.00

$0.00

$0.00

Add to cart
DescriptionShipped From Abroad An original patented product that can be used for both intubated patients and non-intubated patients, breaking through the limitation that mainstream modules can only be used for intubated patients.
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock
  • This white coat laboratory coat is a knee-length overcoat/smock is perfect for professionals in the medical field or by those involved in laboratory work.
  • This garment is Easy to wash and made from a cotton polyester blend, allowing it to be washed at high temperature and make it easy to see if it is clean.
  • Easy to wash.
Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped from Abroad
  • Contains Output interface for Anesthesia information management system.
  • Complete with backup battery for working more than 120 minutes.
Delivery & Availability: Typically 21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped from Abroad
  • Contains Output interface for Anesthesia information management system.
  • Complete with backup battery for working more than 30 minutes.
Delivery & Availability: Typically 21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In Stock It is for performing spinal/epidural or combined spinal/epidural or never-block loco-regional anaesthesia on patinet in clinical surgery.

Delivery & Availability:

Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped from Abroad The MORPHEUS E is an anaesthesia machine with electronic flowmeters and it can be used on adult, children and newborn patients. The MORPHEUS M is suitable for administration of Oxygen – Air – Nitrous Oxide – Halothane – Enflurane – Isoflurane – Sevoflurane – Desflurane mixtures. Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Content
Features of CO2 Mainstream Module Capno-M+
  • Patented Products
With its compact design and two kinds of adapters, the mainstream module can be used for intubated patients and non-intubated patients. Breathing light intuitively and qualitatively reacts to real-time concentration.
  • High Precision
Careful selection of infrared devices, hardware design and software algorithm, to achieve high signal-to-noise ratio and ensure the measurement accuracy within the temperature range of -5-50°C and the measurement range of 0-20%.
  • Suitable For Adults, Children and Newborns
Excellent performance and low cost. Plug and play, the host does not need an internal circuit, but just a serial port. The data can be measured within 4 seconds after power on.
  • Automatic Pressure Compensation
There is an atmospheric pressure sensor inside, which is suitable for various altitude ranges. Built-in interference gas compensation algorithm.
  • Reliable Carbon Dioxide OEM Solutions
A variety of protocols, so that your products quickly upgrade assembly.  
Specifications of CO2 Mainstream Module Capno-M+
Technique Non-dispersive infrared gas analysis, multi-channel infrared detector, no moving parts
Storage condition -40°C to 70°C,<93% RH, non-condensing
Working condition 5 to 40℃,10 to 90% RH, non-condensing
Circumstance pressure 55-115kP
Power demand 5V ± 5% (max ripple 200 mVp-p)
Power consumption <150mA
lnterface RS-232/Standard E-8-1, 38.4 kBaud,10 ms data interval (KM) or customized communication protocol.
CO2 measurement range 0-150 mmHg, 0-20 kPa, 0-19.7%
CO2 resolution 0.1mmHg
co2 measurement accuracy 0 - 40 mmHg ± 2 mmHg 41 - 70 mmHg ± 5% of reading 71 - 100 mmHg ± 8% of reading 101 - 150 mmHg ± 10% of reading
Respiration rate 3-150 bpm
Respiration rate accuracy ±1% of reading or ±1 rpm whichever is greater
Anesthetic gas compensation N2O, O2, Agent (HOST supplied)
Barometric Pressure Barometric Pressure 400 to 860 mm Hg automatic
Warm-up time To reach designed deviation 97% within 8s, to reach designed deviation within 20s.
Rise time About 70ms
CO2 Stability Shortly drifting: drifting less than 1 mmHg, after 4 hours’ power on. Long drifting: drifting does not influence nominal accuracy after continu hous 140 hours’power on
Calibration No routine user calibration required
Zero proceeding when replacing adaptor
EtCO2 calcualtion every breath, or 10 or 20 seconds averagely
Application Scenarios of CO2 Mainstream Module Capno-M+
  • Innovative Patented Products
Capno-M+ is an innovative carbon dioxide module independently developed by Kingst, which can be used for both intubated and non-intubated patients. It breaks through the limit that the mainstream modules can only be used for intubated patients in the past.
  • High Accuracy
It is equipped with a high-quality Infrared device, hardware design, and software algorithm to achieve gas concentration measurement with a high signal-to-noise ratio;
  • Low Consumption and Easy to use
A variety of adapters for adults, children and newborns, cost-effective, reduce the cost of use;
  • Plug and Play,
No circuit is required inside the host, only one serial port is needed, and the data can be measured within 4 seconds after power-on;
  • Automatic Pressure Compensation
There is an internal atmospheric pressure sensor, suitable for various altitude ranges, and a built-in interference gas compensation algorithm;
  • OEM Solution
Reliable CO2 OEM solution, compatible with multiple protocols, enabling you to quickly upgrade your product.
  • This white coat laboratory coat is a knee-length overcoat/smock is perfect for professionals in the medical field or by those involved in laboratory work.
  • This garment is Easy to wash and made from a cotton polyester blend, allowing it to be washed at high temperature and make it easy to see if it is clean.
  • Easy to wash.
Features:
  • Contains Output interface for Anesthesia information management system.
  • Complete with backup battery for working more than 120 minutes.
Click Here To Download Catalogue
   
 
Features:
  • Contains Output interface for Anesthesia information management system.
  • Complete with backup battery for working more than 30 minutes.
  Technical Specifications:
Model: SD-M2000B
Brand: RENDER
Origin: Made In China
Category: Electronics & Electricity / Electronic Instrument / Electricity Meter & Instrument
Label: anesthesia machine , anesthesia ventilator , anesthesia machine
 
Click Here To Download Catalogue
 
It is for performing spinal/epidural or combined spinal/epidural or never-block loco-regional anaesthesia on patinet in clinical surgery. Component:
  • Epidural needle 16G,
  • Epidural catheter,
  • Epidural filter 0.2 um,
  • Catheter connector,
  • LOR syringe
The MORPHEUS E is an anaesthesia machine with Electronic Flowmeters and it can be used on adult, children and newborn patients. The MORPHEUS E is suitable for administration of Oxygen – Air – Nitrous Oxide – Halothane – Enflurane – Isoflurane – Sevoflurane – Desflurane mixtures. Features:
  • Mechanic gas mixing system
  • Electronic lung ventilator with 12” TFT colour display
  • Valves group: open, semi-closed, closed, heated, with soda lime absorber (1,5 Kg)
  • SIARETEX rapid connection device, Selectatec compatible for 2 vaporizers
  • Gas supply group
  • Ventilation modalities: APCV-PCV; APCV-TV; PSV; APNEA BACK-UP; VC-VAC; VC-VAC BABY; SIMV+PS (volumetric); SPONT; MANUAL.
  • Measured parameters: PAW; PEEP; Vte; ExpMV; Rate; I:E; FiO2, Pmax; Pmean; Pause; Vti; FLOWi; FLOWe; Tinsp; Tesp; Tpause; Cs; Ri
  • Displayed ventilation curves: Paw, Flow, Volume, Loop (Volume/Paw ; Volume/Flow)
  • Adjustable parameters: – O2 built-in Mixer device from 21% to 99% – I:E Adjustable Ratio: 1:1-1:2-1:3-1:4-2:1-3:1 – Inspiratory Flow – PEEP – Breathing Rate – Minute Volume; – Tidal Volume – Inspiratory Pressure Limit – Inspiratory Pause – Inspiratory Time – Trigger
  • Breathing system: The breathing system of Morpheus guarantees to the user an absolute flexibility and easy handling thanks to the noble construction materials employed. The valves group can be drawn-up and it’s totally autoclavable at 121°C and all its parts are manually dismountable, with no need of special tools.The breathing system is made of; Calibrated APL valve, Fresh gas collecting bag, O2 cell for reading of FiO2, Removable 1 kg soda lime canister, Manually inspectionable bellows jar, Safety valve for ambience air suction in case of fresh gas failure, Flow transducer inside the group located on the expiratory line.
Optional accessories 11054 AIRPAK 54 stand-alone medical air compressor 100150/IDF Isoflurane Vaporizer 100148/IDF Fluo-Halotane Vaporizer 100145/IDF Sevoflurane Vaporizer 100151/IDF Desflurane Vaporizer A57.049-800601 gas analysis module (5 AA – CO2 – N2O – O2 – MAC) ric.auto.  
Click Here To Download Catalogue
WeightN/AN/AN/AN/AN/AN/A
DimensionsN/AN/AN/AN/AN/AN/A
en English
Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • Rating
  • Price
  • Description
Click outside to hide the comparison bar