CO2 Mainstream Module Capno-M+

$0.00

Shipped From Abroad

An original patented product that can be used for both intubated patients and non-intubated patients, breaking through the limitation that mainstream modules can only be used for intubated patients.

Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Brands:: Kingst

Description

Features of CO2 Mainstream Module Capno-M+
  • Patented Products

With its compact design and two kinds of adapters, the mainstream module can be used for intubated patients and non-intubated patients. Breathing light intuitively and qualitatively reacts to real-time concentration.

  • High Precision

Careful selection of infrared devices, hardware design and software algorithm, to achieve high signal-to-noise ratio and ensure the measurement accuracy within the temperature range of -5-50°C and the measurement range of 0-20%.

  • Suitable For Adults, Children and Newborns

Excellent performance and low cost. Plug and play, the host does not need an internal circuit, but just a serial port. The data can be measured within 4 seconds after power on.

  • Automatic Pressure Compensation

There is an atmospheric pressure sensor inside, which is suitable for various altitude ranges. Built-in interference gas compensation algorithm.

  • Reliable Carbon Dioxide OEM Solutions

A variety of protocols, so that your products quickly upgrade assembly.

 

Specifications of CO2 Mainstream Module Capno-M+
Technique Non-dispersive infrared gas analysis, multi-channel infrared detector, no moving parts
Storage condition -40°C to 70°C,<93% RH, non-condensing
Working condition 5 to 40℃,10 to 90% RH, non-condensing
Circumstance pressure 55-115kP
Power demand 5V ± 5% (max ripple 200 mVp-p)
Power consumption <150mA
lnterface RS-232/Standard E-8-1, 38.4 kBaud,10 ms data interval (KM) or customized communication protocol.
CO2 measurement range 0-150 mmHg, 0-20 kPa, 0-19.7%
CO2 resolution 0.1mmHg
co2 measurement accuracy 0 – 40 mmHg ± 2 mmHg

41 – 70 mmHg ± 5% of reading

71 – 100 mmHg ± 8% of reading

101 – 150 mmHg ± 10% of reading

Respiration rate 3-150 bpm
Respiration rate accuracy ±1% of reading or ±1 rpm whichever is greater
Anesthetic gas compensation N2O, O2, Agent (HOST supplied)
Barometric Pressure Barometric Pressure 400 to 860 mm Hg automatic
Warm-up time To reach designed deviation 97% within 8s, to reach designed deviation within 20s.
Rise time About 70ms
CO2 Stability Shortly drifting: drifting less than 1 mmHg, after 4 hours’ power on. Long drifting: drifting does not influence nominal accuracy after continu hous 140 hours’power on
Calibration No routine user calibration required
Zero proceeding when replacing adaptor
EtCO2 calcualtion every breath, or 10 or 20 seconds averagely
Application Scenarios of CO2 Mainstream Module Capno-M+
  • Innovative Patented Products

Capno-M+ is an innovative carbon dioxide module independently developed by Kingst, which can be used for both intubated and non-intubated patients. It breaks through the limit that the mainstream modules can only be used for intubated patients in the past.

  • High Accuracy

It is equipped with a high-quality Infrared device, hardware design, and software algorithm to achieve gas concentration measurement with a high signal-to-noise ratio;

  • Low Consumption and Easy to use

A variety of adapters for adults, children and newborns, cost-effective, reduce the cost of use;

  • Plug and Play,

No circuit is required inside the host, only one serial port is needed, and the data can be measured within 4 seconds after power-on;

  • Automatic Pressure Compensation

There is an internal atmospheric pressure sensor, suitable for various altitude ranges, and a built-in interference gas compensation algorithm;

  • OEM Solution

Reliable CO2 OEM solution, compatible with multiple protocols, enabling you to quickly upgrade your product.

Reviews

There are no reviews yet.

Be the first to review “CO2 Mainstream Module Capno-M+”

Your email address will not be published. Required fields are marked *

Quick Comparison

SettingsCO2 Mainstream Module Capno-M+ removeTimesco Jumper Fingertip Pulse Oximeter removeHersill Genesis Anaesthetic Machine removeAgary I.V. Cannula removeKIT FOR THORACENTESIS & PARACENTESIS removeTimesco Eclipse McCoy Laryngoscope Set remove
NameCO2 Mainstream Module Capno-M+ removeTimesco Jumper Fingertip Pulse Oximeter removeHersill Genesis Anaesthetic Machine removeAgary I.V. Cannula removeKIT FOR THORACENTESIS & PARACENTESIS removeTimesco Eclipse McCoy Laryngoscope Set remove
ImageFingertip Pulse OximeterHersill Genesis Anaesthetic MachineTimesco Eclipse McCoy Laryngoscope Set
SKUSF1033560084-2SF1033560450-1SF1033560084-221SF1033560130101-5SF1033560084-54
Rating
Price

$0.00

$17.00

$0.00

$7.10

$0.00

$0.00

Stock
Availability
Add to cart

DescriptionShipped From Abroad An original patented product that can be used for both intubated patients and non-intubated patients, breaking through the limitation that mainstream modules can only be used for intubated patients.
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In Stock Integrated with SPO2 probe and processing display module. Small in volume、light in weight and convenient in carrying. Operation of the product is simple ,low power consumption. SPO2 , PR and Ridisplay,. Pulse rate value display, bar graph display. Low-voltage indication: low-voltage indicator appears before working abnormally which is due to low-voltage. Automatically power off function: when the device is under the state of measuring interface . it will automatically power off within 5 seconds if the finger falls out of probe. Delivery & Availability: Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.Shipped from Abroad The Genesis anaesthesia workstations meet your most ambitious requirements. They stand out for their lung protective ventilation. Application Field: Neonates, Pediatrics & Adults Ventilation Modes: Volume controlled (VC), Pressure controlled (PC), Adaptive Pressure with Volume Guaranteed (APVG) & Pressure Support Ventilation (PSV) Delivery & Availability: Typically 21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.In stock I.V Cannula with wings & injection port 24G/19mm, 0.70mm/20ml/min Injection port with unidirectional valve for facilitating extra medication and preventing back flow. Specially engineered recessed plug with protective ring to avoid risk of contamination. Angle & grooved wings for easy cannulation and to prevent rolling of cannula over patient body. Colour coded cap for easy identification of guage size.
Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In Stock Sirius-XL Eclipse blades feature a flexible tip designed for difficult intubations and are available in Macintosh 4, 3 and 2. Supplied as a blade only in a case or as a blade and handle set in a case.

Delivery & Availability:

Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Content
Features of CO2 Mainstream Module Capno-M+
  • Patented Products
With its compact design and two kinds of adapters, the mainstream module can be used for intubated patients and non-intubated patients. Breathing light intuitively and qualitatively reacts to real-time concentration.
  • High Precision
Careful selection of infrared devices, hardware design and software algorithm, to achieve high signal-to-noise ratio and ensure the measurement accuracy within the temperature range of -5-50°C and the measurement range of 0-20%.
  • Suitable For Adults, Children and Newborns
Excellent performance and low cost. Plug and play, the host does not need an internal circuit, but just a serial port. The data can be measured within 4 seconds after power on.
  • Automatic Pressure Compensation
There is an atmospheric pressure sensor inside, which is suitable for various altitude ranges. Built-in interference gas compensation algorithm.
  • Reliable Carbon Dioxide OEM Solutions
A variety of protocols, so that your products quickly upgrade assembly.  
Specifications of CO2 Mainstream Module Capno-M+
Technique Non-dispersive infrared gas analysis, multi-channel infrared detector, no moving parts
Storage condition -40°C to 70°C,<93% RH, non-condensing
Working condition 5 to 40℃,10 to 90% RH, non-condensing
Circumstance pressure 55-115kP
Power demand 5V ± 5% (max ripple 200 mVp-p)
Power consumption <150mA
lnterface RS-232/Standard E-8-1, 38.4 kBaud,10 ms data interval (KM) or customized communication protocol.
CO2 measurement range 0-150 mmHg, 0-20 kPa, 0-19.7%
CO2 resolution 0.1mmHg
co2 measurement accuracy 0 - 40 mmHg ± 2 mmHg 41 - 70 mmHg ± 5% of reading 71 - 100 mmHg ± 8% of reading 101 - 150 mmHg ± 10% of reading
Respiration rate 3-150 bpm
Respiration rate accuracy ±1% of reading or ±1 rpm whichever is greater
Anesthetic gas compensation N2O, O2, Agent (HOST supplied)
Barometric Pressure Barometric Pressure 400 to 860 mm Hg automatic
Warm-up time To reach designed deviation 97% within 8s, to reach designed deviation within 20s.
Rise time About 70ms
CO2 Stability Shortly drifting: drifting less than 1 mmHg, after 4 hours’ power on. Long drifting: drifting does not influence nominal accuracy after continu hous 140 hours’power on
Calibration No routine user calibration required
Zero proceeding when replacing adaptor
EtCO2 calcualtion every breath, or 10 or 20 seconds averagely
Application Scenarios of CO2 Mainstream Module Capno-M+
  • Innovative Patented Products
Capno-M+ is an innovative carbon dioxide module independently developed by Kingst, which can be used for both intubated and non-intubated patients. It breaks through the limit that the mainstream modules can only be used for intubated patients in the past.
  • High Accuracy
It is equipped with a high-quality Infrared device, hardware design, and software algorithm to achieve gas concentration measurement with a high signal-to-noise ratio;
  • Low Consumption and Easy to use
A variety of adapters for adults, children and newborns, cost-effective, reduce the cost of use;
  • Plug and Play,
No circuit is required inside the host, only one serial port is needed, and the data can be measured within 4 seconds after power-on;
  • Automatic Pressure Compensation
There is an internal atmospheric pressure sensor, suitable for various altitude ranges, and a built-in interference gas compensation algorithm;
  • OEM Solution
Reliable CO2 OEM solution, compatible with multiple protocols, enabling you to quickly upgrade your product.
Integrated with SPO2 probe and processing display module • Small in volume, light in weight, convenient in carrying • Simple operation, lower power consumption • OLED screen display • SPO2, PR, bar graph of pulse, plethysmogram, blood perfusion index, battery indication display • 4 directions display, 6 display models, large fonts display • Brightness control, Demo mode, Setup menu • Movement interference • Alarm function and adjustable alarm parameters • Can be connected to mobile phones through Bluetooth; can support Android and iOS client • Auto power-off when no signal after 10s • Powered by 2*AAA alkaline batteries Specification: • Size: 62 x 37 x 32mm • Peak wavelength range of the light emitted from the probe: red light 660nm±3; infrared light 905nm±5 • Maximum optical output power of the probe: 1.2mW for infrared light (905nm) • Bluetooth module: 4.0 (single-mode) • Working temperature: 5℃ to 40℃ (41°F to 104°F) • Relative humidity: 15% to 80%, non-condensing • Atmospheric pressure: 70kPa to 106kPa • Rated voltage: DC 3V Package included: • 1 x JUMPER JPD-500F Bluetooth Fingertip Pulse Oximeter • 2 x AAA Batteries • 1 x Carry Case • 1 x Lanyard • 1 x English User ManualThe Genesis anaesthesia workstations meet your most ambitious requirements. They stand out for their lung protective ventilation, accuracy and performance, cost saving, design and ergonomics, safety and versatility.   TECHNICAL SPECIFICATION OPERATING DATA
  • Weight - 105 kg
  • Dimensions - 92 cm Wide x 68 cm Deep x 139 cm High (93 cm to the table surface)
  • Packaging Dimensions - 105 cm Wide x 75 cm Deep x 160 cm High
  • Operating voltage supply - 110 to 240 V~, 47 to 63 Hz (12 to 6 A)
  • Power input - 120 W typically (max. 1.2 kW with auxiliary outlets used)
  • Battery autonomy - 90 min typically
  • Auxiliary power outlets - 4, with automatic protection
  • O2, N2O and Air supply - 2.7 to 6.9 bar (39.1 to 100 psi)
  • Screen - TFT 18.5" (47 cm) projected capacitive touchscreen
  • Protection class - Class I, gas analyser type BF defibrillation proof
  • Classification - Class II b
  • Storage - One front drawer with self-brake system and two back cabinets with door
  • Lighting - LED bar below the screen controlled from the touchscreen
  • Auxiliary integrated systems - Auxiliary 02 flow meter (0-15 L/min), Auxiliary 02 suppy valve (NF standard) and Suction device
  • Communication ports - 1 x RS-232, 2 x USB, 1 x LAN Ethernet
Fresh Gases (02, N20 and Air, electronically controlled)
  • Fresh gas flow - 0 and 0.1 to 18 L/min 02/N20/Air
  • Accuracy - 0.1 to 0.5 L/min = ±0.05 L/min; 0.5 to 18 L/min = ±10 %
  • 02 concentration - 21 to 100% vol. with Air, 25 to 100% with N20 (minimum 200 ml/min 02)
  • 02 Safety fresh gas (backup) - 0-0.2-0.4-0.7-1-1.5- 2- 3- 4- 6- 8-10-12-15 L/min 02
  • 02 flush (+02) - 40 L/min standard (adjustable 25 - 75 L/min upon requirement)
Breathing System (CABS)
  • Autoclavable - 134 °C
  • Weight of breathing system - 9.8 kg
  • C02 absorber volume - 1.5 L
  • Leakage - < 150 mL/min (at 30 hPa)
  • Pressure limiting valve APL - 0 to 70 hPa
  • Pressure relief valve - 125 hPa
  • Vacuum safety valve - 0.3 hPa
  • resistance at 60L/min - 5.80 hPa
  • resistance at 60L/min - 2.90 hPa
  • resistance at 30L/min - 3.55 hPa
  • resistance at 30L/min - 0.89 hPa
  • Internal Compliance at 30 hPa - 15 mL
  VENTILATOR Operation / Ventilation Modes Volume controlled (VC) modes:
  • Volume Controlled Ventilation (VCV)
  • VC Synchronized Intermittent Mandatory Ventilation (VC-SIMV)
  • VC-SIMV with Pressure Support (VC-SIMV-PS) *
Pressure controlled (PC) modes:
  • Pressure Controlled Ventilation (PCV)
  • PC Synchronized Intermittent Mandatory (PC-SIMV)
  • PC-SIMV with Pressure Support (PC-SIMV-PS) *
Adaptive Pressure with Volume Guaranteed (APVG) modes (other trade names: Autoflow,PCVR, PRVC, AVAPS, VC+)
  • Adaptive Pressure with Volume Guaranteed (APVG) *
  • APVG Synchronized Intermittent Mandatory (APVG-SIMV) *
  • APVG -SIMV with Pressure Support (APVG-SIMV-PS) *
Pressure Support Ventilation (PSV) *
  • (other trade names: PS, ASB, SPS, IPS)
  Non-mechanical Operation / Ventilation Modes
  • Manual ventilation through the CABS system (Auto/Manual software controlled)
  • Spontaneous ventilation either through the bellows (auto mode) or through the bag
  • (manual mode) Manual ventilation through the external fresh gas outlet for non-rebreathing systems (Bain, Mapleson, ...)
Application field: Neonates, Pediatrics & Adults
  • Tidal volume - 5 to 1500 mL
  • Inspiratory pressure - 0 to 68 hPa
  • Ventilation frequency ­- 3 to 120/min
  • Inspiratory time - 0.05 to 16.6s
  • l:E ratio - 5:1 to 1:8
  • Inspiratory pause - 0 to 60%
  • Inspiratory flow - max. 150 L/min
  • PEEP - 0 to 30 hPa
  • Flow trigger - 0.2 to 15 L/min
  • Pressure support - 5 to 50 hPa
  • Ramp time - 0.1 to 2 s
  • Maximum pressure - 0 to 68 hPa
  MONITORING
  • 5" (47 cm) projected capacitive touchscreen, supported on a 360° rotating and 2 axis tilting arm.
  • Measurements displayed: Peak pressure; Plateau pressure; Mean pressure; Expiratory minute ventilation; Expiratory tidal volume; Inspiratory tidal volume; Expiratory volumeter; Breathing rate; Compliance and Resistance (in VC modes); Patient info (age, weight, MAC, Class ASA); Connected sensors; Battery status; Power supply status; Gases supply pressures for 02, N20 and Air; Inspiratory and expiratory concentration of 02, N20, C02 and Anaesthetic gas*
  • Parametres charted as curves (up to 3 simultaneously): Airway pressure; Expiratory flow; Inspiratory flow; Volume; Fresh gases (Rotstyle); Concentration of 02, N20, C02 and Anaesthetic gas*; Trends: Minute volume, MAC and gases (02, N20, C02 and Anaesthetic gas).
  • Display for the performance of the hospital Anaesthetic Gas Scavenging System (AGSS).
  • Configurable interface: bright/dark, multi-language.
  • Loops (up to 2 simultaneously): Volume-Pressure, Flow-Volume, Pressure-Flow, C02-Volume.
  • Fresh gas virtual rotameters for 02, N20, Air. * C02, N20 and Anaesthetic gas monitoring with the accessory multigas analyzer main-stream or side-stream; 02 real-time monitoring via paramagnetic
 
Click Here To Download Catalogue
I.V Cannula with wings & injection port 24G/19mm, 0.70mm/20ml/min Injection port with unidirectional valve for facilitating extra medication and preventing back flow. Specially engineered recessed plug with protective ring to avoid risk of contamination. Angle & grooved wings for easy cannulation and to prevent rolling of cannula over patient body. Colour coded cap for easy identification of guage size.

KIT FOR THORACENTESIS & PARACENTESIS

The device is used to drain ascitic fluid and pleural liquid, it contains everything necessary for performing thoracentesis and paracentesis procedure (needles  syringe and collection bag). Products are customized upon request.  
Reference Description Qty per box
H92000E TORASET 1-55 30 pcs
H92010E TORASET 1-80 30 pcs
H92020E TORASET 1-VER 30 pcs
H92030E TORASET2-55 30 pcs
H92040E TORASET 2-80 30 pcs
H92050E TORASET 2-VER 30 pcs
H92001E TORAMATIC 1-55 30 pcs
H92011E TORAMATIC 1-80 30 pcs
H92021E TORAMATIC 1-VER 30 pcs
H92120E PARASET 2 30 pcs
H92160E PARASET 5 20 pcs
H92200E PARASET 8 20 pcs
H92240E PARASET 12 15 pcs
 
Click here to download Catalogue
Sirius-XL Eclipse blades feature a flexible tip designed for difficult intubations and are available in Macintosh 4, 3 and 2. Supplied as a blade only in a case or as a blade and handle set in a case.
  • The non-replaceable glass fibre bundle is fully enclosed in the blade which allows easy cleaning.
  • Rigid metal construction from fully autoclaveable, antimagnetic stainless steel.
  • Lever positioned at the rear of the blade to control the tilting tip.
  • 3 metal ball bearings for secure fitting.
  • Green ISO 7376 fitting metal block compatible with fibre optic handles.
  • Tilting tip for elevation of the epiglottis, providing an improved view of the larynx, without excessive force.
  • Atraumatic distal end.
  • Fully autoclaveable metal blade, covered by a 5 year guarantee or 4,000 autoclaves, whichever is sooner.
Click Here To Download Catalogue
WeightN/AN/AN/AN/AN/AN/A
DimensionsN/AN/AN/AN/AN/AN/A
Additional information
Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • Rating
  • Price
  • Description
Click outside to hide the comparison bar
Compare