CO2 Mainstream Module Capno-M+
$0.00
Shipped From Abroad
An original patented product that can be used for both intubated patients and non-intubated patients, breaking through the limitation that mainstream modules can only be used for intubated patients.
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Description
Features of CO2 Mainstream Module Capno-M+
- Patented Products
With its compact design and two kinds of adapters, the mainstream module can be used for intubated patients and non-intubated patients. Breathing light intuitively and qualitatively reacts to real-time concentration.
- High Precision
Careful selection of infrared devices, hardware design and software algorithm, to achieve high signal-to-noise ratio and ensure the measurement accuracy within the temperature range of -5-50°C and the measurement range of 0-20%.
- Suitable For Adults, Children and Newborns
Excellent performance and low cost. Plug and play, the host does not need an internal circuit, but just a serial port. The data can be measured within 4 seconds after power on.
- Automatic Pressure Compensation
There is an atmospheric pressure sensor inside, which is suitable for various altitude ranges. Built-in interference gas compensation algorithm.
- Reliable Carbon Dioxide OEM Solutions
A variety of protocols, so that your products quickly upgrade assembly.
Specifications of CO2 Mainstream Module Capno-M+
Technique | Non-dispersive infrared gas analysis, multi-channel infrared detector, no moving parts |
Storage condition | -40°C to 70°C,<93% RH, non-condensing |
Working condition | 5 to 40℃,10 to 90% RH, non-condensing |
Circumstance pressure | 55-115kP |
Power demand | 5V ± 5% (max ripple 200 mVp-p) |
Power consumption | <150mA |
lnterface | RS-232/Standard E-8-1, 38.4 kBaud,10 ms data interval (KM) or customized communication protocol. |
CO2 measurement range | 0-150 mmHg, 0-20 kPa, 0-19.7% |
CO2 resolution | 0.1mmHg |
co2 measurement accuracy | 0 – 40 mmHg ± 2 mmHg
41 – 70 mmHg ± 5% of reading 71 – 100 mmHg ± 8% of reading 101 – 150 mmHg ± 10% of reading |
Respiration rate | 3-150 bpm |
Respiration rate accuracy | ±1% of reading or ±1 rpm whichever is greater |
Anesthetic gas compensation | N2O, O2, Agent (HOST supplied) |
Barometric Pressure | Barometric Pressure 400 to 860 mm Hg automatic |
Warm-up time | To reach designed deviation 97% within 8s, to reach designed deviation within 20s. |
Rise time | About 70ms |
CO2 Stability | Shortly drifting: drifting less than 1 mmHg, after 4 hours’ power on. Long drifting: drifting does not influence nominal accuracy after continu hous 140 hours’power on |
Calibration | No routine user calibration required |
Zero | proceeding when replacing adaptor |
EtCO2 calcualtion | every breath, or 10 or 20 seconds averagely |
Application Scenarios of CO2 Mainstream Module Capno-M+
- Innovative Patented Products
Capno-M+ is an innovative carbon dioxide module independently developed by Kingst, which can be used for both intubated and non-intubated patients. It breaks through the limit that the mainstream modules can only be used for intubated patients in the past.
- High Accuracy
It is equipped with a high-quality Infrared device, hardware design, and software algorithm to achieve gas concentration measurement with a high signal-to-noise ratio;
- Low Consumption and Easy to use
A variety of adapters for adults, children and newborns, cost-effective, reduce the cost of use;
- Plug and Play,
No circuit is required inside the host, only one serial port is needed, and the data can be measured within 4 seconds after power-on;
- Automatic Pressure Compensation
There is an internal atmospheric pressure sensor, suitable for various altitude ranges, and a built-in interference gas compensation algorithm;
- OEM Solution
Reliable CO2 OEM solution, compatible with multiple protocols, enabling you to quickly upgrade your product.
Quick Comparison
Settings | CO2 Mainstream Module Capno-M+ remove | Hersill Genesis Anaesthetic Machine remove | Timesco Jumper Fingertip Pulse Oximeter remove | Lab/Ward Coat remove | Elastomeric Pump (Disposable Infusion Pump) with PCA remove | Timesco Orion Laryngoscope Set remove | ||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Name | CO2 Mainstream Module Capno-M+ remove | Hersill Genesis Anaesthetic Machine remove | Timesco Jumper Fingertip Pulse Oximeter remove | Lab/Ward Coat remove | Elastomeric Pump (Disposable Infusion Pump) with PCA remove | Timesco Orion Laryngoscope Set remove | ||||||||||||||||||||||||||||||||||||||||
Image | ![]() | ![]() | ![]() | ![]() | ![]() | ![]() | ||||||||||||||||||||||||||||||||||||||||
SKU | SF1033560450-1 | SF1033560084-2 | SF1033560084-222 | SF1033560084-18 | SF1033560084-53 | |||||||||||||||||||||||||||||||||||||||||
Rating | ||||||||||||||||||||||||||||||||||||||||||||||
Price |
|
| $17.00 | $11.00 |
| $98.50 | ||||||||||||||||||||||||||||||||||||||||
Stock | ||||||||||||||||||||||||||||||||||||||||||||||
Availability | ||||||||||||||||||||||||||||||||||||||||||||||
Add to cart | ||||||||||||||||||||||||||||||||||||||||||||||
Description | Shipped From Abroad
An original patented product that can be used for both intubated patients and non-intubated patients, breaking through the limitation that mainstream modules can only be used for intubated patients.
Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| Shipped from Abroad The Genesis anaesthesia workstations meet your most ambitious requirements. They stand out for their lung protective ventilation. Application Field: Neonates, Pediatrics & Adults Ventilation Modes: Volume controlled (VC), Pressure controlled (PC), Adaptive Pressure with Volume Guaranteed (APVG) & Pressure Support Ventilation (PSV) Delivery & Availability: Typically 21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | In Stock Integrated with SPO2 probe and processing display module. Small in volume、light in weight and convenient in carrying. Operation of the product is simple ,low power consumption. SPO2 , PR and Ridisplay,. Pulse rate value display, bar graph display. Low-voltage indication: low-voltage indicator appears before working abnormally which is due to low-voltage. Automatically power off function: when the device is under the state of measuring interface . it will automatically power off within 5 seconds if the finger falls out of probe. Delivery & Availability: Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | In stock
| In Stock
This product make the tension of silicon capsule as the driving force to control the flow by micro porous tube, it was pre-selected by doctor base on patients'situation, and then and then handed over to the patients ' self- management “to relieve or ease the pain
Delivery & Availability: Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | In Stock
Timesco’s laryngoscope sets are available in a variety of configurations to suit your requirements, containing 3 blades and 1 handle and supplied in a convenient polypropylene case. Alternatively, Timesco also supplies single-use sets as a ready to use a system containing one blade and one handle in a clear pouch.
Delivery & Availability: Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | ||||||||||||||||||||||||||||||||||||||||
Content | Features of CO2 Mainstream Module Capno-M+
With its compact design and two kinds of adapters, the mainstream module can be used for intubated patients and non-intubated patients. Breathing light intuitively and qualitatively reacts to real-time concentration.
Careful selection of infrared devices, hardware design and software algorithm, to achieve high signal-to-noise ratio and ensure the measurement accuracy within the temperature range of -5-50°C and the measurement range of 0-20%.
Excellent performance and low cost. Plug and play, the host does not need an internal circuit, but just a serial port. The data can be measured within 4 seconds after power on.
There is an atmospheric pressure sensor inside, which is suitable for various altitude ranges. Built-in interference gas compensation algorithm.
A variety of protocols, so that your products quickly upgrade assembly.
Specifications of CO2 Mainstream Module Capno-M+
Application Scenarios of CO2 Mainstream Module Capno-M+
| The Genesis anaesthesia workstations meet your most ambitious requirements. They stand out for their lung protective ventilation, accuracy and performance, cost saving, design and ergonomics, safety and versatility.
TECHNICAL SPECIFICATION
OPERATING DATA
Click Here To Download Catalogue | Integrated with SPO2 probe and processing display module • Small in volume, light in weight, convenient in carrying • Simple operation, lower power consumption • OLED screen display • SPO2, PR, bar graph of pulse, plethysmogram, blood perfusion index, battery indication display • 4 directions display, 6 display models, large fonts display • Brightness control, Demo mode, Setup menu • Movement interference • Alarm function and adjustable alarm parameters • Can be connected to mobile phones through Bluetooth; can support Android and iOS client • Auto power-off when no signal after 10s • Powered by 2*AAA alkaline batteries Specification: • Size: 62 x 37 x 32mm • Peak wavelength range of the light emitted from the probe: red light 660nm±3; infrared light 905nm±5 • Maximum optical output power of the probe: 1.2mW for infrared light (905nm) • Bluetooth module: 4.0 (single-mode) • Working temperature: 5℃ to 40℃ (41°F to 104°F) • Relative humidity: 15% to 80%, non-condensing • Atmospheric pressure: 70kPa to 106kPa • Rated voltage: DC 3V Package included: • 1 x JUMPER JPD-500F Bluetooth Fingertip Pulse Oximeter • 2 x AAA Batteries • 1 x Carry Case • 1 x Lanyard • 1 x English User Manual |
| This product make the tension of silicon capsule as the driving force to control the flow by micro porous tube, it was pre-selected by doctor base on patients'situation, and then and then handed over to the patients ' self- management “to relieve or ease the pain Product Components: one-way valve medicated device, elastic liquid storage device, liquid medicine filter, current limiting device, automatic liquid feeding device ( CBI & PCA ), pipe and the external connector; Product Features: 1. The continued to liquid (CBI) make the drug-stored sac mechanical stretch as a driving force, limited the flow through the micro porous tube to the patient safely, effectively, slightly, continuous uniform injection of liquid to analgesic effect; extrusion pump body does not affect the liquid normal velocity; liquid filtering device which can control the particles enter the body better; 2. Continued to liquid + self control to liquid ( CBI+PCA ) make the drug-stored sac mechanical stretch as a driving force, limited the flow through the micro porous tube to the patient safely, effectively, slightly, continuous uniform injection of liquid to analgesic effect; Automatic medicated function is the patients can medicate according to pain independently. Extrusion pump body does not affect the liquid normal velocity; liquid filtering device which can control the particles enter the body better; How to use: 1. Get analgesia pump out from sterile packaging, removing the cap of medicine inlet and outlet; pour the analgesic liquid in the liquid storage device, draw out the air from the liquid storage. 2. Finish medicating, waiting for the liquid outflow from the medicine outlet; please clamp tightly to stop flowing for preparation. 3. Control keys (PCA key) is a function key to add the medicine base on continue to medicated by patients' self-controlled. So the patients can self-control the PCA key under the guidance of doctors, according to the needs while they are in treatment. At the same time, doctor should fill in PCA treatment card, so that they can analyze the condition from PCA additional times. | Timesco’s laryngoscope sets are available in a variety of configurations to suit your requirements, containing 3 blades and 1 handle and supplied in a convenient polypropylene case. Alternatively, Timesco also supply single use sets as a ready to use system containing one blade and one handle in a clear pouch.
Click Here To Download Catalogue | ||||||||||||||||||||||||||||||||||||||||
Weight | N/A | N/A | N/A | N/A | N/A | N/A | ||||||||||||||||||||||||||||||||||||||||
Dimensions | N/A | N/A | N/A | N/A | N/A | N/A | ||||||||||||||||||||||||||||||||||||||||
Additional information |
Reviews
There are no reviews yet.