CO2 Sidestream Module Capno-S

$0.00

Shipped From Abroad

A side stream EtCO2 sensor, accurate and durable, suitable for various complex environments. Compatible with multiple protocols. Plug and play, no zero calibration required. Stable and durable.

Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
SF1033560130170-8
Brands:: Kingst

Description

Features of CO2 Sidestream Module Capno-S
  • Plug And Play

There is no circuit inside the host, just a serial port.

  • High Precision

Temperature pressure compensation, timing and self-calibration functions, full-range calibration, to ensure accurate measurement within the range of 0-20%

Long Service Life And Extremely Low Noise

The gas circuit, hardware and software are carefully designed to ensure the long-term stability of the module

Low Power Consumption

Suitable for battery-powered use, automatic pressure compensation. Maintain measurement accuracy in an extremely wide air pressure range of 400-960mmHg.

Patented Water Filters

The Filters can work continuously for a long time, and can be reused, reducing the user’s cost.

Dedicated Fi-lock Air Inlet Interface

Intelligent identification and light indication of filter insertion and breathing status.

 

Complete EtCO2 OEM Solutions

Multiple communication protocols, and more than 20 years of accumulated technology and experience, easily help you achieve technical and practical improvements

 

Specifications of CO2 Sidestream Module Capno-S
Technique Non-dispersive infrared gas analysis, multi-channel infrared detector, no moving parts
Storage condition -40°C to 70°C,<93% RH, non-condensing
Working condition 5°C to 40°C, 30 to 75% RH, non-condensing
Circumstance pressure 55-115 KPa
Power demand 5V ± 5% (max ripple 200 mVp-p)
Power consumption Usual typical value 120 mA during deviation and calibration, typical value 280 mA
lnterface RS-232/Standard E-8-1, 38.4 kBaud,10 ms data interval (KM) or customization
CO2 measurement range 0-150 mmHg, 0-20 kPa, 0-19.7%
CO2 resolution 0.1mmHg
co2 measurement accuracy 0 – 40 mmHg ± 2 mmHg

41 – 70 mmHg ± 5% of reading

71 – 100 mmHg ± 8% of reading

101 – 150 mmHg ± 10% of reading

Respiration rate 3-150 bpm
Respiration rate accuracy ±1% of reading or ±1 rpm whichever is greater
Anesthetic gas compensation N2O, O2, Agent (HOST supplied)
Barometric Pressure Barometric Pressure 400 to 860 mm Hg automatic
Warm-up time To reach designed deviation 97% within 8s, to reach designed deviation within 2 min.
Rise time <200ms
Calibration No routine user calibration required
Flow control Range: 50-250ml/min adjustable Accuracy: <±20%

 

Application Scenarios of CO2 Sidestream Module Capno-S
  • High signal-to-noise ratio

Capno-S is a side stream CO2 module.

It is equipped with high-quality Multi-Channel Narrowband Filters, IR Light Source, Well-designed Hardware Circuit and Software Algorithms to achieve gas concentration measurement with high signal-to-noise ratio;

  • Long continuous working time

For side stream modules, there are built-in long-life sampling pumps, ensuring a one-way flow of exhaled air; and a high-quality filter that can work for a long time even in a high-temperature environment.

  • Plug-and-play

It can be used in conjunction with a multi-parameter monitor. The monitor only needs one interface, which can be connected to the module for use.

  • Atmospheric pressure compensation

There is an internal atmospheric pressure sensor, which can automatically adjust the atmospheric pressure and suitable for various altitude ranges and harsh environments;

  • OEM solutions

We provide reliable carbon dioxide OEM solutions, with multiple protocols, so that products can be quickly upgraded and assembled.

Reviews

There are no reviews yet.

Be the first to review “CO2 Sidestream Module Capno-S”

Your email address will not be published. Required fields are marked *

Quick Comparison

SettingsCO2 Sidestream Module Capno-S removeMeasuring Beaker 250ml removeLab/Ward Coat removePetri Dish Per Pack removeGlass Measuring Cylinder 1000ml removePlastic Test Tube Rack remove
NameCO2 Sidestream Module Capno-S removeMeasuring Beaker 250ml removeLab/Ward Coat removePetri Dish Per Pack removeGlass Measuring Cylinder 1000ml removePlastic Test Tube Rack remove
Image
SKUSF1033560130170-8SF1033560084-153SF1033560084-222SF1033560084-172SF1033560084-164SF1033560084-174
Rating
Price

$0.00

$4.95

$11.00

$0.00

$7.00

$3.00

Stock
Availability
Add to cart

DescriptionShipped From Abroad A side stream EtCO2 sensor, accurate and durable, suitable for various complex environments. Compatible with multiple protocols. Plug and play, no zero calibration required. Stable and durable.
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock • Height: 95mm • Width: 85mm • Diameter: 75mm • Volume: 250ml
Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock
  • This white coat laboratory coat is a knee-length overcoat/smock is perfect for professionals in the medical field or by those involved in laboratory work.
  • This garment is Easy to wash and made from a cotton polyester blend, allowing it to be washed at high temperature and make it easy to see if it is clean.
  • Easy to wash.
Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock Premium petri dishes made to withstand wet or dry repeated sterilisation. The heavy borosilicate glass and can handle direct flames.
Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock
  • Class B (+/-10ml)
  • Graduations: 10ml, 100ml to 1000ml
  • O.D. x Height: 66 x 458mm (2.5 x 18in) (approx.), Base: 125mm (5 in)
  • Type 1 Class A Borosilicate 3.3 Glass
  • Capacity in accordance with ASTM E-1272
Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock
  • Sturdy high-impact plastic rack will hold from 6 to 31 test tubes up to 25mm in a diameter
  • Easy to assemble
  • Chemical resistant
Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Content
Features of CO2 Sidestream Module Capno-S
  • Plug And Play
There is no circuit inside the host, just a serial port.
  • High Precision
Temperature pressure compensation, timing and self-calibration functions, full-range calibration, to ensure accurate measurement within the range of 0-20%
Long Service Life And Extremely Low Noise
The gas circuit, hardware and software are carefully designed to ensure the long-term stability of the module
Low Power Consumption
Suitable for battery-powered use, automatic pressure compensation. Maintain measurement accuracy in an extremely wide air pressure range of 400-960mmHg.
Patented Water Filters
The Filters can work continuously for a long time, and can be reused, reducing the user's cost.
Dedicated Fi-lock Air Inlet Interface
Intelligent identification and light indication of filter insertion and breathing status.  
Complete EtCO2 OEM Solutions
Multiple communication protocols, and more than 20 years of accumulated technology and experience, easily help you achieve technical and practical improvements  
Specifications of CO2 Sidestream Module Capno-S
Technique Non-dispersive infrared gas analysis, multi-channel infrared detector, no moving parts
Storage condition -40°C to 70°C,<93% RH, non-condensing
Working condition 5°C to 40°C, 30 to 75% RH, non-condensing
Circumstance pressure 55-115 KPa
Power demand 5V ± 5% (max ripple 200 mVp-p)
Power consumption Usual typical value 120 mA during deviation and calibration, typical value 280 mA
lnterface RS-232/Standard E-8-1, 38.4 kBaud,10 ms data interval (KM) or customization
CO2 measurement range 0-150 mmHg, 0-20 kPa, 0-19.7%
CO2 resolution 0.1mmHg
co2 measurement accuracy 0 - 40 mmHg ± 2 mmHg 41 - 70 mmHg ± 5% of reading 71 - 100 mmHg ± 8% of reading 101 - 150 mmHg ± 10% of reading
Respiration rate 3-150 bpm
Respiration rate accuracy ±1% of reading or ±1 rpm whichever is greater
Anesthetic gas compensation N2O, O2, Agent (HOST supplied)
Barometric Pressure Barometric Pressure 400 to 860 mm Hg automatic
Warm-up time To reach designed deviation 97% within 8s, to reach designed deviation within 2 min.
Rise time <200ms
Calibration No routine user calibration required
Flow control Range: 50-250ml/min adjustable Accuracy: <±20%
 
Application Scenarios of CO2 Sidestream Module Capno-S
  • High signal-to-noise ratio
Capno-S is a side stream CO2 module. It is equipped with high-quality Multi-Channel Narrowband Filters, IR Light Source, Well-designed Hardware Circuit and Software Algorithms to achieve gas concentration measurement with high signal-to-noise ratio;
  • Long continuous working time
For side stream modules, there are built-in long-life sampling pumps, ensuring a one-way flow of exhaled air; and a high-quality filter that can work for a long time even in a high-temperature environment.
  • Plug-and-play
It can be used in conjunction with a multi-parameter monitor. The monitor only needs one interface, which can be connected to the module for use.
  • Atmospheric pressure compensation
There is an internal atmospheric pressure sensor, which can automatically adjust the atmospheric pressure and suitable for various altitude ranges and harsh environments;
  • OEM solutions
We provide reliable carbon dioxide OEM solutions, with multiple protocols, so that products can be quickly upgraded and assembled.
Measuring beaker • Lined with metric increments up to 200ml • Material: Borosilicate glass • Pouring lip • Great for molecular mixology and molecular gastronomy • Height: 95mm • Width: 85mm • Diameter: 75mm • Volume: 250ml
  • This white coat laboratory coat is a knee-length overcoat/smock is perfect for professionals in the medical field or by those involved in laboratory work.
  • This garment is Easy to wash and made from a cotton polyester blend, allowing it to be washed at high temperature and make it easy to see if it is clean.
  • Easy to wash.
Premium petri dishes made to withstand wet or dry repeated sterilisation. The heavy borosilicate glass and can handle direct flames. Features:
  • Heavy duty borosilicate glass petri dish
  • Autoclavable, can withstand direct flames and harsh chemicals
  • Individually wrapped top and bottom in wax paper
  • Class B (+/-10ml)
  • Graduations: 10ml, 100ml to 1000ml
  • O.D. x Height: 66 x 458mm (2.5 x 18in) (approx.), Base: 125mm (5 in)
  • Type 1 Class A Borosilicate 3.3 Glass
  • Capacity in accordance with ASTM E-1272
Capacity 1000.0 milliliters
Ean 0817556011295
Graduation Interval 10.00 milliliters
Item Weight 1.93 pounds
Material Borosilicate Glass
Number of Items 1
Part Number 213I15
Size Single
  • Sturdy high-impact plastic rack will hold from 6 to 31 test tubes up to 25mm in a diameter
  • Easy to assemble
  • Chemical resistant

WeightN/AN/AN/AN/AN/AN/A
DimensionsN/AN/AN/AN/AN/AN/A
Additional information
Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • Rating
  • Price
  • Description
Click outside to hide the comparison bar
Compare