Corneal Trephine

$0.00

Shipped From Abroad

18mm

Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
SF103356013094-84
Brands:: HASA-OPTIX

Reviews

There are no reviews yet.

Be the first to review “Corneal Trephine”

Your email address will not be published. Required fields are marked *

Quick Comparison

SettingsCorneal Trephine removePantoscopic Ophthalmoscope removeBinocular Indirect Ophthalmoscope removeOphthalmic Ultrasound Pachymeter removeAutomatic Computer Goldmann (Visual Field Analyzer) removeApplanation Tonometer remove
NameCorneal Trephine removePantoscopic Ophthalmoscope removeBinocular Indirect Ophthalmoscope removeOphthalmic Ultrasound Pachymeter removeAutomatic Computer Goldmann (Visual Field Analyzer) removeApplanation Tonometer remove
ImageMecan MCE-800 Pantoscopic OphthalmoscopeMecan YZ25C Binocular Indirect OphthalmoscopeMecan SW 1000P Ophthalmic Ultrasound PachymeterMecan Applanation Tonometer YZ30X
SKUSF103356013094-84SF1033560107-3SF1033560107-4SF1033560107-18SF103356013013SF1033560107-1
Rating
Price

$0.00

$0.00

$880.00

$2,365.00

$3,850.00

$0.00

Stock
Availability
Add to cart

DescriptionShipped From Abroad 18mm
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped from abroad The brand-new Pantoscopic Ophthalmoscope is a portable digital imaging device which makes it possible to view and take pictures of the eyes.
Delivery & Availability: Typically 14 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.  
Shipped from abroad Super lightweight design, reduce fatigue, operation is very convenient.
Delivery & Availability: Typically 14 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.  
Shipped from abroad
  • Large color liquid-crystal screen.
  • Touch screen input, easy operation.
  • Curve freezing: Manual/Auto mode, controlled by pedal.
  • Built-in speed thermal printer.
  • Can display ultrasound waveform when measuring.
Delivery & Availability: Typically 14 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.  
In Stock
Features: The Bio-1000 automated perimeter absorbs the advantages of international advanced perimetry devices. It comprises the highly integrated computer, optics, machinery and electronics systems.   Delivery & Availability: Typically 7-14 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped from abroad The product is designed on the principle basis of Goldman tonometer. It can be connected with slit lamp(Carl Zeiss type).
Delivery & Availability: Typically 14 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.  
ContentThe brand-new Pantoscopic Ophthalmoscope is a portable digital imaging device which makes it possible to view and take pictures of the eyes. The optical access of the Pantoscopic Ophthalmoscope is aligned to the visual axis of the smartphone camera by the adaptor which allows to you take pictures of the fundus and retinal nerve in high resolution. You could save pictures for each patient or email and print as needed. The Pantoscopic Ophthalmoscope provides a 5X larger view of the fundus compared with the standard ophthalmoscope. It has a wider view field of 230. Without dilating the pupil, the fundus imagines could be captured at any time and places. Features:
  • Rapid capture of fundus images on your cellphone.
  • Get eyeground documentation in an easy and low-cost way.
  • Send images to your peers across the continum of care instantly.
  • Easy carry to capture images at any clinical circumstance and work efficiently.
  • Make patient education easier.
  • 5X larger view of the fundus vs. standard ophthalmoscopes in an undilated eye.
  • Halogen lamp provides bright, white light.
  • Apertures and Filters: Looking at the pupil through an add-on corneal viewing lens, the practitioner can detect lens opacities easily.
Ophthalmoscope Features:
  • LED bulb(low-temperature,low-pressure,high-brightness) with long lifetime to make the illumination uniformly and bright. The illumination brightness can be adjusted continuously.
  • Imaging clearly,strong dimensional sense and large field of view range.The main body part of this device adopts engineering plastics and is designed to be compact and exquisite.
  • Super lightweight design, reduce fatigue,operation is very convenient.
  • The portable power supply is suitable for surgery, ward round and consultation.
  • This device is equipped with color filter,teaching mirror and sclera depressor to be more handy in operation.
Technical Specifications:
Pupilary Adjustment 52mm~74mm adjustable
Intensity of Illumination continuous adjustment with the maximum intensity no less than 500Lx
Headband 520~640mm in circumference, 85~125mm in depth
Light Spots Big spot, middle spot  and small spot
Filters Red-free, white and cobalt blue
Light Source LED light
Source of Power Li+ battery, DC 7.4V
AC 100~240V, 50/60Hz
Input Power Battery charger: 15 VA
AC charger: 50VA
Dimension of Main Part 142mm × 48mm × 128mm(long×breadth×high)
Weight of Main Part 230g
Features:
  • Large color liquid-crystal screen.
  • Touch screen input, easy operation.
  • Curve freezing: Manual/Auto mode, controlled by pedal.
  • Built-in speed thermal printer.
  • Can display ultrasound waveform when measuring.
  • Each group is the average of 20 measurements.
  • Switch between IOP measured value and actual value.
  • Can input name, ID and operator's name.
Technical Specifications:
P scan probe 20MHZ, angle of 45 degrees makes easier operation
Resolution 5um
Measuring range 150um~1500um
Display SINGLE mode and MAP mode
The Bio-1000 automated perimeter absorbs the advantages of international advanced perimetry devices. It comprises the highly integrated computer, optics, machinery and electronics systems. Incorporated with the advanced configuration, comprehensive software inspection categories, and strictly in accordance with international Goldman standard, it provide scientific means for glaucoma, fundus disease, visual pathway injury and neurological diseases. Feature:         * Comprehensive real-time monitoring,Heiji-krakau physiological blind spot monitoring,gaze tracking/head position tracking,automatic measurement of pupil diameter, reduce the impact of pupil effect on visual field detection. * Personalized design,accurate clinical analysis,accurate and repid examination strategy. * Under international Goldman standard,providing a variety of classic test procedures and report analysis. Technical Specification:
Inspection range 90°
Inspection distance 30cm
Background light brightness White 31.5abs
Visual target brightness 1abs --- 10000abs
Visual target size Goldmann III
Visual target interval time 200ms
Visual target interval time Stardard or adjustment according to patient reflection
Threshold test model Center5°- 16°,center10°- 68, 24-2, 30-2, 30°- 60°,nasal step
Upper threshold test model 30°-40,30°-76,P-60,60°-81,60°-120,190°-135,nasal side
Special detection strategy Esterman monocular,Esterman binocular,user-customized test,150°driver monocular fast detection, 150°driver monocular standard detection, upper36°detection, blind spot detection, 150° horizontal straightness detection
Pupil size test Automatic
Fixation monitoring Blind spot monitoring, eye position deviation alarm, eyedeviation curve
Enviroment light detection Automatic
Analysis software Reliability analysis,single vision report,triple visionreport,GPA half vision analysis, GPA glaucoma developing analysis, VFI vision index analysis
Operation system Win7 above
 
Click Here To Download Catalogue
Applanation Tonometer is designed on the principle basis of Goldman tonometer. It can be connected with slit lamp(Carl Zeiss type). Features of Applanation Tonometer:
  • When used with slit lamp, it can be used to examine the eyes and measure ocular pressure.
  • Accurate measurement and total tolerance are less than 0.066KPa(0.55Hg).
  • Directly get the ocular pressure and do not need to look up the conversion table.
  • The measured ocular pressure is not affected by hardness of eye.
  • The affected?ocular volume is just 0.56 cubic millimeter.
  • Adjustable measuring pressure ensures the long-term stability and reliability.
Technical Specifications Applanation Tonometer:
  • Measuring Range: 0~1064 Kpa
  • Light Ring Displacement: 1.53×2=3.06mm
  • Diameter of Prism Head: 7mm
  • Moving Range of Prism Head: 3mm
WeightN/AN/AN/AN/AN/AN/A
DimensionsN/AN/AN/AN/AN/AN/A
Additional information
Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • Rating
  • Price
  • Description
Click outside to hide the comparison bar
Compare