Description | Shipped From Abroad
18mm
Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| Shipped from abroad
The NJC-4 Lensmeter is used to measure the diopters of spherical lens and cylinder lens, the axis of cylinder lens, the strength and the baseline direction of shuttle lens, it can also stamp the optical center of lens, the axis of cylinder len and the base direction of shuttle lens.
Delivery & Availability:
Typically 14 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| Shipped from abroad
- Software image workstation
- B, B+B, B+A, A modes
- Video review for 100 images
- PDF report output
- Optional 20MHz B Probe: vitreous plus function
Delivery & Availability:
Typically 14 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| Shipped from abroad
This product is used to measure the intraocular pressure (IOP) by measuring the depth produced on the surface of the cornea by a load of a known weight. Each division on the scale corresponds to 1/20mm corneal depth.
Delivery & Availability:
Typically 14 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| In Stock
Features:
The Bio-1000 automated perimeter absorbs the advantages of international advanced perimetry devices. It comprises the highly integrated computer, optics, machinery and electronics systems.
Delivery & Availability:
Typically 7-14 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| Shipped from abroad
- Light rack with integral casting, CNC machining, the measuring system is more stable, good consistency.
- Color LCD display, 5.7 inches man-machine interface is more comfortable.
- PD automatic measurement function, automatically PD value.
Delivery & Availability:
Typically 14 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
|
Content | | The NJC-4 Lensmeter is used to measure the diopters of the spherical lens and cylinder lens, the axis of cylinder lens, the strength and the baseline direction of shuttle lens, it can also stamp the optical center of the lens, the axis of cylinder lens, and the base direction of shuttle lens. This instrument (Both Ac and Dc are permitted Two cells When Dc) has clear readings and graduations as well as high objective precision and reliabilities except that it can be operated easily and conveniently, AU the lenses and the made glasses can be measured by it, therefore, it is a required and ideal measuring instrument for glasses manufactures, glasses stores and ophthalmological hospitals.
Technical Specifications:
- Eyepiece focusing range: ±5D
- The top point diopter measuring range: 0—±20D
- The minimum measuring square value: 0.125D
- The shuttle lens measuring range: 5A
- The shuttle lens square value: 1A
- The cylinder lens axial range: 0—180°
- The cylinder lens axial square value: 5°
- The maximum diameter of the measured lenses l00m/m
- Power supply: AC 110V-6V DC 3V
- Note: This item is AC 110V; The battery is not included!
| Functions of Ophthalmic AB Scan Machine:
- Software image workstation
- B, B+B, B+A, A modes
- Video review for 100 images
- PDF report output
- Optional 20MHz B Probe: vitreous plus function
Technical Specifications:
A scan |
1.Probe: 10MHz frequencies, with LED
2.Depth: 40mm
3.Precision: ±0.05mm
4.Eye mode: Phakic / Aphakic / Dense / Various IOL
5.Measurement: Anterior chamber depth, lens thickness, vitreous body length, total length and average
6.IOL Formula: SRK-II, SRK-T, BINKHORST, HOLLADAY, HOFFER-Q, HAIGIS, Stat.
7.Calculation: Average and standard deviation
8.Store: 10 Scanning results for each eye |
B scan |
1.Probe: 10MHz/20MHz (optional), Magnetic driven, noiseless
2.Scanning Mode: Sector Scanning
3.Resolution: Lateral ≤0.3mm; Vertical≤0.2mm
4.Geometric Location Precision: Lateral≤10%; Vertical≤5%
5.Depth: 60mm
6.Enhance the part of vitreous body and retina
7.Gain of probe:30dB-105dB
8.Scanning Angle : 53°
9.Gray Scale: 256
10.False Color: Multi colors OTC
11.Measure Mode: distances, perimeter and area
12.Movies: 100 images movie review,AVI ZIP JPG format image output
13.Output: PDF format case report, connect to normal printer |
Others |
1.Display Mode :B, B+B, B+A, A
2.Hint: preset keyword
3.Case Search: Multi-keywords
4.Working Platform: Windows XP, VISTA, WINDOWS7
5.User-defined report template |
| This product is used to measure the intraocular pressure (IOP) by measuring the depth produced on the surface of the cornea by a load of a known weight. Each division on the scale corresponds to 1/20mm corneal depth.
Features:
- Schiotz type
- All the parts that contact the cornea are made of stainless steel and are anti-acid, which does no harm to issues
- The instrument is safe, reliable, accurate, and convenient to carry
| The Bio-1000 automated perimeter absorbs the advantages of international advanced perimetry devices. It comprises the highly integrated computer, optics, machinery and electronics systems. Incorporated with the advanced configuration, comprehensive software inspection categories, and strictly in accordance with international Goldman standard, it provide scientific means for glaucoma, fundus disease, visual pathway injury and neurological diseases.
Feature:
* Comprehensive real-time monitoring,Heiji-krakau physiological blind spot monitoring,gaze tracking/head position tracking,automatic measurement of pupil diameter, reduce the impact of pupil effect on visual field detection.
* Personalized design,accurate clinical analysis,accurate and repid examination strategy.
* Under international Goldman standard,providing a variety of classic test procedures and report analysis.
Technical Specification:
Inspection range |
90° |
Inspection distance |
30cm |
Background light brightness |
White 31.5abs |
Visual target brightness |
1abs --- 10000abs |
Visual target size |
Goldmann III |
Visual target interval time |
200ms |
Visual target interval time |
Stardard or adjustment according to patient reflection |
Threshold test model |
Center5°- 16°,center10°- 68, 24-2, 30-2, 30°- 60°,nasal step |
Upper threshold test model |
30°-40,30°-76,P-60,60°-81,60°-120,190°-135,nasal side |
Special detection strategy |
Esterman monocular,Esterman binocular,user-customized test,150°driver monocular fast detection, 150°driver monocular standard detection, upper36°detection, blind spot detection, 150° horizontal straightness detection |
Pupil size test |
Automatic |
Fixation monitoring |
Blind spot monitoring, eye position deviation alarm, eyedeviation curve |
Enviroment light detection |
Automatic |
Analysis software |
Reliability analysis,single vision report,triple visionreport,GPA half vision analysis, GPA glaucoma developing analysis, VFI vision index analysis |
Operation system |
Win7 above |
| Features:
- Using the ARM processor and the latest domestic image processing, the system is fast and the image is clear.
- Japan’s mature optical path system, humanized automatic mist measurement process, to reduce the error caused by adjustment, more precise measurements.
- Light rack with integral casting, CNC machining, the measuring system is more stable, good consistency.
- Color LCD display, 5.7 inches man-machine interface is more comfortable.
- PD automatic measurement function, automatically PD value.
- One key lock function, quickly locking mobile platforms.
- Innovative designs, according to the structure of human body engineering, to bring customers good aesthetic feeling and comfortable.
- Data transmission with CV7200, improved efficiency of online 5x magnification options, respond to different viewing needs.
Technical Specifications:
Measurement Range
Vertex distance.......................................0.0,12.0,13.75,15mm
Sphere.......................................-20D~+20D(0.12/0.25D step)
Cylinder...........................................0~±10D(0.12/0.25D step)
Axis...............................................................1~180°(1° step)
PD distance............................................................30~85mm
PD..........................................................................10~86mm
Minimum pupil diameter..............................................Ø2.0mm
Target................................................automatic fogging target
Hardware specifications
Monitor.............................................................5.7" color LCD
Printer......................................................Fast thermal printer
Power saving function....................OFF, 5/15 mins (selectable)
Power supply................................AC110~220V, 60/50Hz, 50W
Dimension/weight..............................288x500x480mm(14kgs) |
Reviews
There are no reviews yet.