Description | Shipped From Abroad
DFV Cerathos was designed with state-of-the-art technology to provide safe and effective treatment. Its optical system was developed to provide a safe dosage of energy homogeneously over the cornea to be treated. It has a dedicated microprocessor system that controls all functions and monitors the amount of energy emitted by the equipment. It's versatile and accurate!
Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| Shipped from abroad
Super lightweight design, reduce fatigue, operation is very convenient.
Delivery & Availability:
Typically 14 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| Shipped from abroad
- Top Optical System.
- High eyepoint, comfort.
- Five steps drum zoom design, easier to use 6x, 10x, 16x, 25x, 40x magnification.
- High Definition Eyepieces, More Comfortable for Viewing.
Delivery & Availability:
Typically 14 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| In Stock
Features:
The Bio-1000 automated perimeter absorbs the advantages of international advanced perimetry devices. It comprises the highly integrated computer, optics, machinery and electronics systems.
Delivery & Availability:
Typically 7-14 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| Shipped from abroad
The NJC-4 Lensmeter is used to measure the diopters of spherical lens and cylinder lens, the axis of cylinder lens, the strength and the baseline direction of shuttle lens, it can also stamp the optical center of lens, the axis of cylinder len and the base direction of shuttle lens.
Delivery & Availability:
Typically 14 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| Shipped from abroad
This ultra-portable is an excellent diagnostic instrument for the examination of anterior segment structures and ocular abnormalities.
Delivery & Availability:
Typically 14 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
|
Content |
Description
RELIABLE!
Power control with automatic calibration and reliability certified according to medical safety standards evaluated by Anvisa.
VERSATILE AND MODERN!
Dedicated microprocessor system; Commands integrated into the console; Agility in adjusting parameters on the touch screen;
Independent aiming system; Integrated color camera;
Treatment evolution bar.
FRIENDLY INTERFACE!
° Touch screen display that facilitates treatment configuration and monitoring.
° Integrated high sensitivity Watec color camera (0.3lx. F2.0).
° Color touchscreen display with high contrast.
° All controls integrated into a single-volume cabinet close to the patient.
° Clear identification of important treatment parameters.
° Agility in adjusting parameters on the same display screen.
° Progressive bar that indicates the temporal evolution of the treatment and the correct times for riboflavin application.
° Three treatment profile options record the desired parameters.
| Ophthalmoscope Features:
- LED bulb(low-temperature,low-pressure,high-brightness) with long lifetime to make the illumination uniformly and bright. The illumination brightness can be adjusted continuously.
- Imaging clearly,strong dimensional sense and large field of view range.The main body part of this device adopts engineering plastics and is designed to be compact and exquisite.
- Super lightweight design, reduce fatigue,operation is very convenient.
- The portable power supply is suitable for surgery, ward round and consultation.
- This device is equipped with color filter,teaching mirror and sclera depressor to be more handy in operation.
Technical Specifications:
Pupilary Adjustment |
52mm~74mm adjustable |
Intensity of Illumination |
continuous adjustment with the maximum intensity no less than 500Lx |
Headband |
520~640mm in circumference, 85~125mm in depth |
Light Spots |
Big spot, middle spot and small spot |
Filters |
Red-free, white and cobalt blue |
Light Source |
LED light |
Source of Power |
Li+ battery, DC 7.4V |
AC 100~240V, 50/60Hz |
Input Power |
Battery charger: 15 VA |
AC charger: 50VA |
Dimension of Main Part |
142mm × 48mm × 128mm(long×breadth×high) |
Weight of Main Part |
230g |
| Slit Lamp Features:
- Top Optical System.
- High eyepoint, comfort.
- Five steps drum zoom design, easier to use 6x, 10x, 16x, 25x, 40x magnification.
- High Definition Eyepieces, More Comfortable for Viewing.
Technical Specifications:
Microscope Type |
Galileo Parallel |
Optics |
Super Optic System |
Magnification Change Way |
Drum Rotation |
Eyepiece Magnification |
12.5x |
Total Magnifications |
6x 10x, 16x, 25x, 40x |
Diopter Adjustment |
-5D ~+5D |
Slit Width |
0-14MM Continuous |
Slit Height |
1-14MM Continuous |
Slit Angle |
0°- 180° Adjustable |
Light Source |
LED |
Light Spot Diameter |
0.2mm, 2mm, 3mm, 5mm, 10mm, 14mm |
Filter |
Heat Absorption; Grey; Redfree; Cobalt Blue |
Fixation |
Red LED |
Electrical |
|
Illumination Bulb |
LED |
Input Voltage |
110V/220V (±10%) |
Applanation Tonometer Interface |
Included |
| The Bio-1000 automated perimeter absorbs the advantages of international advanced perimetry devices. It comprises the highly integrated computer, optics, machinery and electronics systems. Incorporated with the advanced configuration, comprehensive software inspection categories, and strictly in accordance with international Goldman standard, it provide scientific means for glaucoma, fundus disease, visual pathway injury and neurological diseases.
Feature:
* Comprehensive real-time monitoring,Heiji-krakau physiological blind spot monitoring,gaze tracking/head position tracking,automatic measurement of pupil diameter, reduce the impact of pupil effect on visual field detection.
* Personalized design,accurate clinical analysis,accurate and repid examination strategy.
* Under international Goldman standard,providing a variety of classic test procedures and report analysis.
Technical Specification:
Inspection range |
90° |
Inspection distance |
30cm |
Background light brightness |
White 31.5abs |
Visual target brightness |
1abs --- 10000abs |
Visual target size |
Goldmann III |
Visual target interval time |
200ms |
Visual target interval time |
Stardard or adjustment according to patient reflection |
Threshold test model |
Center5°- 16°,center10°- 68, 24-2, 30-2, 30°- 60°,nasal step |
Upper threshold test model |
30°-40,30°-76,P-60,60°-81,60°-120,190°-135,nasal side |
Special detection strategy |
Esterman monocular,Esterman binocular,user-customized test,150°driver monocular fast detection, 150°driver monocular standard detection, upper36°detection, blind spot detection, 150° horizontal straightness detection |
Pupil size test |
Automatic |
Fixation monitoring |
Blind spot monitoring, eye position deviation alarm, eyedeviation curve |
Enviroment light detection |
Automatic |
Analysis software |
Reliability analysis,single vision report,triple visionreport,GPA half vision analysis, GPA glaucoma developing analysis, VFI vision index analysis |
Operation system |
Win7 above |
| The NJC-4 Lensmeter is used to measure the diopters of the spherical lens and cylinder lens, the axis of cylinder lens, the strength and the baseline direction of shuttle lens, it can also stamp the optical center of the lens, the axis of cylinder lens, and the base direction of shuttle lens. This instrument (Both Ac and Dc are permitted Two cells When Dc) has clear readings and graduations as well as high objective precision and reliabilities except that it can be operated easily and conveniently, AU the lenses and the made glasses can be measured by it, therefore, it is a required and ideal measuring instrument for glasses manufactures, glasses stores and ophthalmological hospitals.
Technical Specifications:
- Eyepiece focusing range: ±5D
- The top point diopter measuring range: 0—±20D
- The minimum measuring square value: 0.125D
- The shuttle lens measuring range: 5A
- The shuttle lens square value: 1A
- The cylinder lens axial range: 0—180°
- The cylinder lens axial square value: 5°
- The maximum diameter of the measured lenses l00m/m
- Power supply: AC 110V-6V DC 3V
- Note: This item is AC 110V; The battery is not included!
| Features:
- Ultra-portable: This ultra-portable is an excellent diagnostic instrument for the examination of anterior segment structures and ocular abnormalities. Its easy-to-operate optical system produces a high-brightness, continuously adjustable slit image ideal for pediatric and geriatric setting, emergency department screenings, ward rounds, beside examination, post-op evaluations, and mission work;
- LED illumination: the first and the only portable slit lamp in the world applying LED illumination system. The most prominent advantage of our LED illumination system gives the examiner the clearest image without glare;
- Comfortable using experience: The low heat radiation from our LED lamp makes the most comfortable examine experience for the patient;
- Sharpest Slit: With the blade imaging system S150 gives equally sharpest slit as the best classic slit lamp in the world;
- No need to replace illumination lamp: The LED lamp used in S150 portable slit lamp is rated 20,000 hours at full power. Its lifetime is almost 10 times longer than a normal halogen lamp;
- Power-saving: S150 can work for long hours without changing batteries.
Technical Specifications:
- Magnification: 5x
- Range of slit length: 5mm~11mm
- Minimum slit width: 0.2mm
- Working distance: 12~32mm
- Power supply: AA batteries x 2
- Illumination: LED blub(3.3V/1W)
- Battery life: More than 3h(AA alkaline batteries x 2)
- Net weight: 150g(without batteries)
How to Operate:
- Press the Power Switch to turn the slit lamp on/off
- Loosen the Locking Screw
- Twist the Lamp Body while holding the Magnifier Bracket still till the slit is in the required angle
- Push or pull the Lamp Body while holding the Magnifier Bracket still to set the Magnifier into a position comfortable for observation
- Fasten the Locking Screw
- Pull the Lamp Head back and forth for adjusting the width and the length of the slit, as well as the intensity of the light
|
Reviews
There are no reviews yet.