Cryometrix B-90 Freezer

$0.00

Shipped From Abroad

The B-90 is a state-of-the-art liquid nitrogen blast freezer. Blast freezers are different from regular lab freezers in that they freeze the product placed within them much faster. The B-90 blast freezer can cool the payload bay from 20°C to -90°C in 5 minutes.

The B-90 blast freezes products with air frozen by liquid nitrogen. No nitrogen is exposed to products during this process, maintaining high product quality.

 

Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
SF1033560130146-11
Brands:: Mira Lab

Description

 

Physical Property Metric Imperial
Dimensions (Depth x Width x Height) 1062 mm x 1224 mm x 2126 mm 41.8″ x 48.2″ x 83.7″
Weight 738 kg 1626 lbs.
Payload Capacity 700 L 24.7 ft3
2mL Vial Capacity 48,000 48,000
Payload Dimensions (Depth x Width x Height) 578 mm x 800 mm x 1524 mm 22.76″ x 31.5″ x 60″
Electrical 208 – 240 VAC 120 VAC, 60 Hz
LN2 Inlet Pressure 650 – 758 kPa 90 – 125 PSI
Adjustable Set Point 20°C to -90°C 68°F to -130°F
Temperature Uniformity 3°C ± at -90°C 5°F ± at -130°F
Cool Down Time 20°C to -80°C 7 min 7 min
Powerful Innovation
  • Next-Gen Liquid Nitrogen Tech
    • Cryometrix freezers don’t use traditional mechanical compressors. Mechanical compressors utilize refrigerants, an example being freon, to produce cold temperatures. These are noisy and use large amounts of electricity.
    • LN2 has a boiling point of -196°C, enabling freezers who use it to go to temperatures as low as -196°C. Most refrigerants have boiling points greater than -100°C, making it difficult for freezers using them to operate at temperatures below that.
  • Low Energy Usage
    • Cryometrix freezers use 7x less electricity than comparable lab freezers.
    • LN2 operates on pressure and requires no electricity to function, enabling it to function without power in an emergency situation.
  • Extreme Reliability
    • Cryometrix freezers don’t require HVAC systems to cool the ambient temperature in order to operate. They can operate in any ambiance, and actually cool the environment around it.
    • There are practically no moving parts on Cryometrix freezers, making them last up to 4 times as long as comparable lab freezers with hardly any maintenance.
    • Are practically silent when in operation.
  • Easily Expandable
    • Cryometrix freezers consume little electricity, enabling the customer to add units to their facility with zero electrical complications.
    • The effective footprint is below 8 square feet and little to no space is needed on the sides, easily fitting into any facility.
  • Extreme Versatility
    • Many blast freezers use metal plates to freeze product, severely limiting their use to thin and flat objects. Others inject LN2 directly into the payload bay, risking harmful exposure to the product.
    • The B-90 Blast Freezer uses liquid nitrogen in an efficient and powerful manner, allowing it to blast freeze anything that can fit inside it.
  • 20 Year Warranty
    • Cryometrix freezers automatically come with a 20-year warranty on their cooling systems.
Environment Friendly
  • Clean Emissions
    • Cryometrix freezers only emit nitrogen outside your building, which already makes up over 75% of the Earth’s atmosphere.
  • Long-Lasting
    • The cooling system of Cryometrix freezers are built to last 20 years, with a warranty to cover it.
Cost Efficient
  • Space Efficient
    • Cryometrix freezers have the smallest footprint for its volume, costing less in floor space and allowing you to fit more units in your current space.
  • Simple Design
    • The upright design allows for quick and convenient access, reducing labor costs and risks.
  • Low Energy Costs
    • LN2 technology uses much less electricity than traditional compressor-based technologies.
    • Cryometrix freezers don’t need energy intensive HVAC systems to operate efficiently.
  • Greater Throughput
    • The increased capability of Cryometrix freezers allows faster turnaround times and thus greater profits.
Complete Safety
  • Closed Nitrogen System
    • There is zero contact between LN2 and the operator or product.
    • LN2 storage is simple and completely autonomous.
  • Unreactive
    • Nitrogen isn’t flammable or explosive like many refrigerants used in compressor-based technologies.
  • Easy Cleaning
    • The 100% stainless steel interior/exterior of the freezer is easy to clean without harsh industrial chemicals.
Sample Integrity
  • Closed System
    • No LN2 is exposed to the sample, maintaining the samples integrity.
  • Data-Logging
    • Cryometrix freezers automatically track temperature and other useful data.
  • Emergency Valve
    • Cryometrix freezers have redundant manual valves that can be used during a power outage to maintain the temperature in the payload bay.
  • Temperature Uniformity
    • Multiple fans create a high flux of airflow to maintain uniform temperature within the payload bay.

Reviews

There are no reviews yet.

Be the first to review “Cryometrix B-90 Freezer”

Your email address will not be published. Required fields are marked *

Quick Comparison

SettingsCryometrix B-90 Freezer removeSkyla Hi POC Clinical Chemistry Analyzer removeEppendorf Minispin Centrifuge removeErma B-111 Bilirubin Meter removePlastic Urine Container Per Pack removeSkyla HB1 POC Clinical Chemistry Auto Analyzer remove
NameCryometrix B-90 Freezer removeSkyla Hi POC Clinical Chemistry Analyzer removeEppendorf Minispin Centrifuge removeErma B-111 Bilirubin Meter removePlastic Urine Container Per Pack removeSkyla HB1 POC Clinical Chemistry Auto Analyzer remove
Image
SKUSF1033560130146-11SF1033560060-2SF1033560084-116SF1033560084-6SF1033560084-106SF1033560060-1
Rating
Price

$0.00

$0.00

$0.00

$715.00

$8.20

$0.00

Stock
Availability
Add to cart

DescriptionShipped From Abroad

The B-90 is a state-of-the-art liquid nitrogen blast freezer. Blast freezers are different from regular lab freezers in that they freeze the product placed within them much faster. The B-90 blast freezer can cool the payload bay from 20°C to -90°C in 5 minutes.

The B-90 blast freezes products with air frozen by liquid nitrogen. No nitrogen is exposed to products during this process, maintaining high product quality.  
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped from Abroad The skyla Hi POC Clinical Chemistry Analyzer provides clinical testing laboratories of medical facilities and clinics with an in-vitro clinical chemistry diagnostic tool that is compact, portable, and reports rapid results.The use of skyla Hi in the management of diabetes enables better access to testing and rapid clinical decision making, discussion,and implementation of optimized treatment. Delivery & Availability: Typically 14 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.In stock
Powerful and user-friendly MiniSpin Centrifuge are small enough so that each workstation can be equipped with a “personal” centrifuge. The rotor, inner centrifuge lid, and lid latch are made of metal for maximum operation safety. Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Aboard  The advanced B111 Bilirubinmeter provides fast, accurate results for Total bilirubin level in neonates with only 40μl serum or plasma sample. It determines total bilirubin by dual wavelength photometric analysis. Suited for pediatric setups, small workload labs & hospitals because of its compact and portable design. Advanced, benchtop and precise instrument for measuring Total Bilirubin.

Delivery & Availability:

Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock
  • Total Volume: 60mL.
  • Specimen Container, Leak-proof, Ideal for Pathology/Histology/Cytology reagent pre-filling sample preparation.
  • Made of premium PP material, it is durable for usage.
  • Some measurements can be used to not only use urine samples, it can also be used for other liquids.
Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped from Abroad The skyla HB1 Clinical Chemistry Analyzer provides clinical testing laboratories of medical facilities and clinics with an in-vitro clinical chemistry diagnostic tool that is compact, portable, and reports rapid results. The portable design of the clinical chemistry analyzer utilizes precision photometric measurement technology, combined with the single-use disposable reagent discs. The reagent disc contains a set of dry assay reagents that are used in the quantitative testing of various biomarkers in the blood sample. Delivery & Availability: Typically 14 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Content
 
Physical Property Metric Imperial
Dimensions (Depth x Width x Height) 1062 mm x 1224 mm x 2126 mm 41.8″ x 48.2″ x 83.7″
Weight 738 kg 1626 lbs.
Payload Capacity 700 L 24.7 ft3
2mL Vial Capacity 48,000 48,000
Payload Dimensions (Depth x Width x Height) 578 mm x 800 mm x 1524 mm 22.76″ x 31.5″ x 60″
Electrical 208 – 240 VAC 120 VAC, 60 Hz
LN2 Inlet Pressure 650 – 758 kPa 90 – 125 PSI
Adjustable Set Point 20°C to -90°C 68°F to -130°F
Temperature Uniformity 3°C ± at -90°C 5°F ± at -130°F
Cool Down Time 20°C to -80°C 7 min 7 min
Powerful Innovation
  • Next-Gen Liquid Nitrogen Tech
    • Cryometrix freezers don’t use traditional mechanical compressors. Mechanical compressors utilize refrigerants, an example being freon, to produce cold temperatures. These are noisy and use large amounts of electricity.
    • LN2 has a boiling point of -196°C, enabling freezers who use it to go to temperatures as low as -196°C. Most refrigerants have boiling points greater than -100°C, making it difficult for freezers using them to operate at temperatures below that.
  • Low Energy Usage
    • Cryometrix freezers use 7x less electricity than comparable lab freezers.
    • LN2 operates on pressure and requires no electricity to function, enabling it to function without power in an emergency situation.
  • Extreme Reliability
    • Cryometrix freezers don’t require HVAC systems to cool the ambient temperature in order to operate. They can operate in any ambiance, and actually cool the environment around it.
    • There are practically no moving parts on Cryometrix freezers, making them last up to 4 times as long as comparable lab freezers with hardly any maintenance.
    • Are practically silent when in operation.
  • Easily Expandable
    • Cryometrix freezers consume little electricity, enabling the customer to add units to their facility with zero electrical complications.
    • The effective footprint is below 8 square feet and little to no space is needed on the sides, easily fitting into any facility.
  • Extreme Versatility
    • Many blast freezers use metal plates to freeze product, severely limiting their use to thin and flat objects. Others inject LN2 directly into the payload bay, risking harmful exposure to the product.
    • The B-90 Blast Freezer uses liquid nitrogen in an efficient and powerful manner, allowing it to blast freeze anything that can fit inside it.
  • 20 Year Warranty
    • Cryometrix freezers automatically come with a 20-year warranty on their cooling systems.
Environment Friendly
  • Clean Emissions
    • Cryometrix freezers only emit nitrogen outside your building, which already makes up over 75% of the Earth’s atmosphere.
  • Long-Lasting
    • The cooling system of Cryometrix freezers are built to last 20 years, with a warranty to cover it.
Cost Efficient
  • Space Efficient
    • Cryometrix freezers have the smallest footprint for its volume, costing less in floor space and allowing you to fit more units in your current space.
  • Simple Design
    • The upright design allows for quick and convenient access, reducing labor costs and risks.
  • Low Energy Costs
    • LN2 technology uses much less electricity than traditional compressor-based technologies.
    • Cryometrix freezers don’t need energy intensive HVAC systems to operate efficiently.
  • Greater Throughput
    • The increased capability of Cryometrix freezers allows faster turnaround times and thus greater profits.
Complete Safety
  • Closed Nitrogen System
    • There is zero contact between LN2 and the operator or product.
    • LN2 storage is simple and completely autonomous.
  • Unreactive
    • Nitrogen isn’t flammable or explosive like many refrigerants used in compressor-based technologies.
  • Easy Cleaning
    • The 100% stainless steel interior/exterior of the freezer is easy to clean without harsh industrial chemicals.
Sample Integrity
  • Closed System
    • No LN2 is exposed to the sample, maintaining the samples integrity.
  • Data-Logging
    • Cryometrix freezers automatically track temperature and other useful data.
  • Emergency Valve
    • Cryometrix freezers have redundant manual valves that can be used during a power outage to maintain the temperature in the payload bay.
  • Temperature Uniformity
    • Multiple fans create a high flux of airflow to maintain uniform temperature within the payload bay.
skyla Hi Analyzer enables better access to testing and rapid clinical decision making, discussion, and implementation of optimized treatment. To get the result, only prepare <1 μl fingertips blood or venous blood (depends on test item) without pretreatment with easy steps and then read the result after 6 mins. The device allows two specimens be tested in one run and provides fully automatic procedures from checking the validity of cartridge to printing the results. Reagent Kit
  • HbA1C
  • CRP
  • Lipid Panel (TC,TG, HDL, LDL#)
  • Lipid Plus Panel (Glu,TC,TG, HDL, LDL#)
Main Specification
Principle
Turbidimetric Method / Biochemistry
Device
Testing Time
5~20 minutes (depends on test items)
Display and Interface
5″ TFT color touch screen LCD
Memory Capacity
50,000 test results
Dimension of Analyzer
270 x 188 x 148 mm
Weight of Analyzer
1.7 kg
Dimension of Printer Module
134 x 100 x 82.7 mm
Weight of Printer Module
0.37 kg
Power Supply
100~240 volts AC, 50-60Hz
Data Transmission
USB 2.0*4 / USB 3.0*1 / RS232*1 / RJ45*1 / Wi-Fi (optional)
Reagent and Samples
Samples
Fingertips blood or venous blood
Samples Volume
0.8 ~ 30 μL (depends on test item)
Storage Temperature (Reagent)
2 ~ 8˚C
Humidity
Relative humidity < 95% (Non-condensing)
Temperature
10 ~ 32 ˚C
Click Here To Download Catalogue
Powerful and user-friendly MiniSpin Centrifuge are small enough so that each workstation can be equipped with a “personal” centrifuge. The rotor, inner centrifuge lid, and lid latch are made of metal for maximum operation safety. Features:
  • Rotor capacity: 12 x 1.5/2.0 mL vessels, 2 x PCR strip
  • Max. speed: 14,100 x g (14,500 rpm)
  • Extremely compact footprint — measures 9”W x 4.”H x 9ó”D!
  • Aluminum rotor accommodates twelve 1.5- or 2.0-mL tubes (maximum diameter of 11 mm)
  • Rotor can be autoclaved at 121°C for 20 minutes
  • Minimal sample heat transfer — maximum of 12°C after 20 minutes at max speed
  • Eliminate costly repairs with the low maintenance drive
  • Soft-touch lid closure for ergonomic lid locking — and releases automatically at the end of a run
Technical Specifications:
Speed: 800 – 13,400 rpm (100 rpm steps)
Capacity: 12 x 1.5/2.0 mL
Electrical: 120 V, 60 Hz
Dimensions: (W x D x H) 22.6 x 23.9 x 12.0 cm
Weight: 4.3 kg
 
Click Here To Download Catalogue
The advanced B111 Bilirubinmeter provides fast, accurate results for Total bilirubin level in neonates with only 40μl serum or plasma sample. It determines total bilirubin by dual wavelength photometric analysis. Suited for pediatric setups, small workload labs & hospitals because of its compact and portable design. Advanced, benchtop and precise instrument for measuring Total Bilirubin. Feature
  • Auto zero function: Manual blanking not required
  • Dual wavelength measurement system:
  • 2 wave lengths 455nm and 575nm
  • Plays major role to remove the interference caused due to Hemolysis & turbidity of sample
  • LED Light source:
  • LED does not require replacement as it lasts longer
  • As compared to Lamp, LED are more suitable as there is no intensity fluctuations
  • No warm up time required.
  • Flexible unit selection:
  • Two units either mg/dl or umol/L are selectable, ease of reporting
  • Compact slot for Capillary:
  • Accuracy of results are directly related to proper alignment of Capillary
  • B-111 has the easiest mode to ensure precise values
  • Data transfer:
  • External device can be connected to instrument through RS232 por
  • USB port
Technical Specification
  • Light source - LED
  • Wavelength - 455nm and 575nm
  • Net weight - 1kg
  • Measuring range - 0-30 mg/dl , 510 umol/L
  • Display - 16×2 LCD module with backlight
  • Auto calibration - Yes
  • Sample type - Serum or plasma
  • Sample volume - 40-80μL
  • Test time - <5sec
  • Units - mg/dl or umol/L
  • Dimensions - 150 (W) × 115 (H) × 190 (D) mm
  • Interface - RS232
  • Reading cuvette - Heparinized micro capillary holder
  • Storage temperature - 15-40°c
  • Power supply - DC 9V(DC adapter)
  • Power consumption - <2W
  • Total Volume: 60mL.
  • Specimen Container, Leak-proof, Ideal for Pathology/Histology/Cytology reagent pre-filling sample preparation.
  • Made of premium PP material, it is durable for usage.
  • Some measurements can be used to not only use urine samples, it can also be used for other liquids.
Skyla HB1 Clinical Chemistry Analyzer utilizes precision photometric measurement technology, combined with the single-use disposable reagent discs. The reagent disc contains a set of dry assay reagents that are used in the quantitative testing of various biomarkers in the blood sample. HB1 provides clinical testing laboratories of medical facilities and clinics with an in-vitro clinical chemistry diagnostic tool that is compact, portable, and reports rapid results. Only needs 200µl of blood (whole blood, serum or plasma is accepted.) and no sample preparation is required. All steps are designed automatically from checking the validity of reagent discs and cartridges to printing the results. Over 30 test parameters are allowed with fast analysis and results in 15 minutes. Internal Quality Control (IQC) with self-calibration of optical system, chemicals stability and interference alerts functions monitor and ensure the results with high accuracy. Available Test Panels
  • Renal Function - BUN, CREA eGFR
  • Liver Function - ALB, TP, ALP, ALT, AST, TBIL, DBIL, GGT, LDH A/G#, GLOB#, IBIL
  • Lipid Metabolism - TG, TC, HDL LDL#, VLDL
  • Pancreatitis Markers - AMY, LIPA
  • Carbohydrate Metabolism and Others - GLU , CPK, UA, LAC
  • Inflammatory Markers - CRP
  • Electrolyte - Na, K, Cl, Ca, PHOS, Mg, tCO2
SPECIFICATION Principle
  • Colormetric System : LEDs 340nm~940nm wavelength
Sample & Panel
  • Test Profiles : Panels
  • Measurement Time - Panel: up to 15 tests/ 15 min
  • Sample Type & Volume : 200 μl whole blood (PCV<60%), plasma, serum 
Device
  • User Interface : 5 inch color LCD touch screen
  • Internal Memory : Store up to 50,000 analysis results
  • Printer : Built in thermal printer or external USB printer (PCL 3GUI)
  • USB Socket : USB type A (Host) for external USB Printer, USB flash drive (FAT) or external barcode scanner
  • Data transmission to PC : RS232 serial port or RJ45 (LAN)
  • Dimensions : 233 (W) X 285 (D) X 300 (H) mm
  • Weight : 5.5 kg
Operating Condition
  • Temperature / Humidity : 10 to 32˚C / 5 to 90 %
 