CU Medical Plasma Sterilizer HPS-100

$0.00

Shipped From Abroad

Medium & Large 100L sterilizers Recommended for Small & Medium Medical Hospitals, Community Healthcare Centers, Military Hospitals and big surgical instruments can be sterilized

Delivery & Availability:
Typically 14-21 Working Days – excluding furniture and heavy/bulky equipment. Please contact us for further information.

SF10335601245
Brands:: CU Medical

Description

Medium & Large 100L sterilizers Recommended for Small & Medium Medical Hospitals, Community Healthcare Centers, Military Hospitals and big surgical instruments can be sterilized.

Features:

Easy to install
Simply plug into a standard 220v outlet and your HPS series sterilizers are ready to go. You won’t need additional facilities such as compressed air, drainage system, ventilation system.

Easy to use
You can start/cancel/control the sterilization process by simply pushing key buttons. The selected sterilization cycle will be progressed automatically and you can monitor relevant information such as sterilization conditions, progress status, error messages from the display.

Automatic notification system for regular maintenance
Your HPS series sterilizer will automatically notify you the replacement period of consumables such as pump oil, air filter and so on. After 250 cycles of sterilization, a warning message to change oil will be displayed and your sterilizer will stop working when reaches 300 cycles without change of oil to prevent equipment failure.

Self-Test Features
When malfunction occurs during operation, an error code is displayed by self-test features and the running sterilization cycle is interrupted automatically for safety.

Validation of Sterilization of HPS?100
A PCD(Process Challenge Device) in accordance with EU standards(EN 867-5) is used for the validation of sterilization of HPS-100 series sterilizers at the most difficult positions inside of the sterilization load so that the most challenging medical instruments including dead-end lumens can be sterilized efficiently and effectively. tem, ventilation system.

 

Specifications
Sterilizing Agent: Hydrogen Peroxide, 1 Cycle/Cartridge

Total Cycle Time :
1) Smart Mode – 40min
2) Standard Mode – 48min
3) Special Mode – 56min
Cycle Temperature : 45? ~ 60?
SAL(Sterility Assurance Level) : 10-6(Bacillus)

Material – Aluminum
Volume -100L
Dimensions : Overall – 700mm(W)×1610mm(H)×954mm(D), Chamber – 400mm(W)×358mm(H)×750mm(D)
Weight : 180?
Control : 32bit Micro Processor
Cycle Information : 2.7″(OLED) Display, Printer
Electrical : AC 220-230V~, 50/60Hz
Power Consumption : Max 3.4kw
Installation Requirements : Front – 100cm, Rear, Left side, Right side : 5cm
Placement : Bult-in wheels provide mobility
Room Conditions : Use Environment 10~40?, 30~75%RH, Installation Environment -20~60?, 0~95%RH
Printer : Built-in Thermal Printer(Brief Mode/Detail Mode) Cycle Parameters(Temp, Pressure, Time, Daily&Total Cycle, etc)

 

Click Here To Download Catalogue

Reviews

There are no reviews yet.

Be the first to review “CU Medical Plasma Sterilizer HPS-100”

Your email address will not be published. Required fields are marked *

Quick Comparison

SettingsCU Medical Plasma Sterilizer HPS-100 removeAvalun LabPad Device removeHawksley 1400 Haematocrit Centrifuge removeTest Strip for ApexBio HemoSmart Gold Hemoglobin Meter removeSkyla Hi POC Clinical Chemistry Analyzer removeDiscover 14 Panel Cup with Adulterants Per Pack remove
NameCU Medical Plasma Sterilizer HPS-100 removeAvalun LabPad Device removeHawksley 1400 Haematocrit Centrifuge removeTest Strip for ApexBio HemoSmart Gold Hemoglobin Meter removeSkyla Hi POC Clinical Chemistry Analyzer removeDiscover 14 Panel Cup with Adulterants Per Pack remove
ImageAvalun Labpad machineDrug Test Cup
SKUSF10335601245SF1033560084-65SF1033560084-118SF1033560084-30SF1033560060-2SF1033560084-28
Rating
Price

$0.00

$0.00

$690.00

$9.50

$0.00

$0.00

Stock
Availability
Add to cart

DescriptionShipped From Abroad

Medium & Large 100L sterilizers Recommended for Small & Medium Medical Hospitals, Community Healthcare Centers, Military Hospitals and big surgical instruments can be sterilized

Delivery & Availability: Typically 14-21 Working Days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock The coagulometer, LabPad® INR, measures blood coagulation time thanks to a patented optical technology. This portable In-Vitro Diagnostics (IVD) device works with the Tsmart® INR single-use microcuvettes. Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.In stock
The Hawksley Haematospin 1400 Centrifuges are built in the UK and are made from durable and high-quality components. These centrifuges are ideal for veterinary laboratories and practices specifically designed to produce reliable and accurate results on blood and urine. One of the main features of this centrifuge is that it takes both 2ml microtubes and 75mm microhaematocrits. The classic design of these centrifuges is used worldwide with guaranteed support for all servicing and parts. Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In Stock Twenty Five (25) Test Strip per Pack

Delivery & Availability:

Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped from Abroad The skyla Hi POC Clinical Chemistry Analyzer provides clinical testing laboratories of medical facilities and clinics with an in-vitro clinical chemistry diagnostic tool that is compact, portable, and reports rapid results.The use of skyla Hi in the management of diabetes enables better access to testing and rapid clinical decision making, discussion,and implementation of optimized treatment. Delivery & Availability: Typically 14 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.In stock
The Discover Cup is an all-in-one drug of abuse test cup. The strips are self contained and the entire cup is tamper resistant. Delivery & Availability:
Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
ContentMedium & Large 100L sterilizers Recommended for Small & Medium Medical Hospitals, Community Healthcare Centers, Military Hospitals and big surgical instruments can be sterilized. Features: Easy to install Simply plug into a standard 220v outlet and your HPS series sterilizers are ready to go. You won’t need additional facilities such as compressed air, drainage system, ventilation system. Easy to use You can start/cancel/control the sterilization process by simply pushing key buttons. The selected sterilization cycle will be progressed automatically and you can monitor relevant information such as sterilization conditions, progress status, error messages from the display. Automatic notification system for regular maintenance Your HPS series sterilizer will automatically notify you the replacement period of consumables such as pump oil, air filter and so on. After 250 cycles of sterilization, a warning message to change oil will be displayed and your sterilizer will stop working when reaches 300 cycles without change of oil to prevent equipment failure. Self-Test Features When malfunction occurs during operation, an error code is displayed by self-test features and the running sterilization cycle is interrupted automatically for safety. Validation of Sterilization of HPS?100 A PCD(Process Challenge Device) in accordance with EU standards(EN 867-5) is used for the validation of sterilization of HPS-100 series sterilizers at the most difficult positions inside of the sterilization load so that the most challenging medical instruments including dead-end lumens can be sterilized efficiently and effectively. tem, ventilation system.   Specifications Sterilizing Agent: Hydrogen Peroxide, 1 Cycle/Cartridge Total Cycle Time : 1) Smart Mode – 40min 2) Standard Mode – 48min 3) Special Mode – 56min Cycle Temperature : 45? ~ 60? SAL(Sterility Assurance Level) : 10-6(Bacillus) Material – Aluminum Volume -100L Dimensions : Overall – 700mm(W)×1610mm(H)×954mm(D), Chamber – 400mm(W)×358mm(H)×750mm(D) Weight : 180? Control : 32bit Micro Processor Cycle Information : 2.7″(OLED) Display, Printer Electrical : AC 220-230V~, 50/60Hz Power Consumption : Max 3.4kw Installation Requirements : Front – 100cm, Rear, Left side, Right side : 5cm Placement : Bult-in wheels provide mobility Room Conditions : Use Environment 10~40?, 30~75%RH, Installation Environment -20~60?, 0~95%RH Printer : Built-in Thermal Printer(Brief Mode/Detail Mode) Cycle Parameters(Temp, Pressure, Time, Daily&Total Cycle, etc)  
Click Here To Download Catalogue
The coagulometer, LabPad® INR, measures blood coagulation time thanks to a patented optical technology. This portable In-Vitro Diagnostics (IVD) device works with the Tsmart® INR single-use microcuvettes.
  • User-friendly: the LabPad® INR is designed to be easy to use especially thanks to its 3D-shaped microcuvette that only requires a small drop of blood from a fingertip. Thanks to the color screen, both measurement steps and browsing the list of results are easy to visualize.
  • Quick and reliable: the reliability of INR results is obtained by quality controls that are performed automatically before each measurement. In less than one minute, you can see if you are in your therapeutic range.
  • Connected: the result obtained after performing the test can be transferred to healthcare professionals in charge of your treatment monitoring. This result is complementary to the pie charts and trend reports directly displayed on the LabPad® INR to help you monitoring your treatment
 
Click Here To Download Catalogue
   
The Hawksley Haematospin 1400 Centrifuges are built in the UK and are made from durable and high-quality components. These centrifuges are ideal for veterinary laboratories and practices specifically designed to produce reliable and accurate results on blood and urine. One of the main features of this centrifuge is that it takes both 2ml microtubes and 75mm microhaematocrits. The classic design of these centrifuges is used worldwide with guaranteed support for all servicing and parts. Technical specifications:
  • Speed: 11,800rpm with 24- place rotor
  • RCF: 14,000g with 24-place rotor
  • Acceleration: 0-11,800rpm in 60 seconds, with 24-place rotor
  • Brake: Automatic
  • Noise: 62dB running with 24-place rotor
  • Motor: High precision AC/DC series wound motor, brush gear, computer wound coil winding, balance armature and high speed bearings.
  • Timer: 0-15 minute timer, graduated in 1 minute increments. Automatic switch at zero
  • Weight: 5.1Kg net (without rotor)
  • Dimensions: 23.5cm height x 27cm diameter, footprint 16cm diameter
  • Construction: Aluminium casing with a steel lid
  • Finish: Body cream white baked enamel, with matt black baked enamel lid
 
Click Here To Download Catalogue
Twenty Five (25) Test Strip per Packskyla Hi Analyzer enables better access to testing and rapid clinical decision making, discussion, and implementation of optimized treatment. To get the result, only prepare <1 μl fingertips blood or venous blood (depends on test item) without pretreatment with easy steps and then read the result after 6 mins. The device allows two specimens be tested in one run and provides fully automatic procedures from checking the validity of cartridge to printing the results. Reagent Kit
  • HbA1C
  • CRP
  • Lipid Panel (TC,TG, HDL, LDL#)
  • Lipid Plus Panel (Glu,TC,TG, HDL, LDL#)
Main Specification
Principle
Turbidimetric Method / Biochemistry
Device
Testing Time
5~20 minutes (depends on test items)
Display and Interface
5″ TFT color touch screen LCD
Memory Capacity
50,000 test results
Dimension of Analyzer
270 x 188 x 148 mm
Weight of Analyzer
1.7 kg
Dimension of Printer Module
134 x 100 x 82.7 mm
Weight of Printer Module
0.37 kg
Power Supply
100~240 volts AC, 50-60Hz
Data Transmission
USB 2.0*4 / USB 3.0*1 / RS232*1 / RJ45*1 / Wi-Fi (optional)
Reagent and Samples
Samples
Fingertips blood or venous blood
Samples Volume
0.8 ~ 30 μL (depends on test item)
Storage Temperature (Reagent)
2 ~ 8˚C
Humidity
Relative humidity < 95% (Non-condensing)
Temperature
10 ~ 32 ˚C
Click Here To Download Catalogue
All-in-One Design
FDA 510(K) & CLIA Waived Up to 99% accuracy rate Results in as little as 1 minute 24 Month Shelf Life from Date of Manufacture Secure, seal and send to lab for confirmation Built in temperature strip Available to test up to 17 substances with adulterants or 18 without adulterants Adulterants available
 
 