Deionized Water Purifier

$0.00

Shipped From Abroad

Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
SF1033560130127-45
Brands:: Scitek

Description

Deionized Water Purifier Features:
  1. The deionized water filter has power indicator, pump work indicator, low pressure indicator and system flushing indicator functions.
  2. Using imported ion filtration membranes and high-pressure, silent pure water pumps, the operation quality is more reliable and it is applicable to a wider range of water quality;
  3. It has system flushing function: every time before turning on the water machine, it will automatically flush for 30 seconds and then the system will start to make water;
  4. The water deionizer filter has system protection function: when the water pressure is too low or there is no water, the equipment automatically shuts down, and when the water source comes in, the equipment automatically turns on;
  5. WP-DU series deionized water filter has an online water quality monitoring function, which can monitor the incoming water quality (located above the instrument, near the function detection area, indicated by a digital tube), RO water quality and temperature, and pure water quality and temperature in real time.

 

Deionized Water Purifier Specifications:
Model WP-D20U WP-D30U WP-D40U WP-D50U WP-D60U
Water Output Speed 20L/h 30L/h 40L/h 50L/h 60L/h
Water Supply Requirement Tap water: TDS<200ppm; Water pressure>0.1Mpa;
Water temperature: 5-45℃
Pure Water Quality Conductivity 0.1us/cm (25℃)
PH Value (25℃) None
Oxidizable (Calculated as O) Technical requirements: ≦0.08mg/L;
Test results: ≦0.08mg/L
Evaporation Residue (105±2℃) Technical requirements: ≦1.0mg/L;
Inspection results: 0.7mg/L
Inspection Basis GB/T6682-2008
Consumption 25W
Control System Operation mode display: power, water shortage, flushing, full water, inlet water quality monitoring, RO water quality and temperature UP water quality and temperature, etc.
Safety Performance Automatically enters standby state when there is no water or low water pressure, and enters standby state when the system is full of water (constant pressure).
Purification System Pretreatment unit, external softening filter (recommended in places with high raw water hardness); 1μm deep PP filter element*2+precision activated carbon filter element
RO Reverse Osmosis Unit American original RO reverse osmosis membrane/membrane group
Post Purification Unit Purification column
Standard Accessories Host + accessory package
Shipping Size (WxDxH)(mm) 533x435x550
N.W/G.W 23kg/25kg 28kg/30kg 33kg/35kg

Reviews

There are no reviews yet.

Be the first to review “Deionized Water Purifier”

Your email address will not be published. Required fields are marked *

Quick Comparison

SettingsDeionized Water Purifier removeSkyla Hi POC Clinical Chemistry Analyzer removeZenithlab (IB-9025A) Laboratory Incubator removeDiscover 5 Panel Cup with Adulterants Per Pack remove8 Bucket Centrifuge removeLittle Sister Table Top Autoclave remove
NameDeionized Water Purifier removeSkyla Hi POC Clinical Chemistry Analyzer removeZenithlab (IB-9025A) Laboratory Incubator removeDiscover 5 Panel Cup with Adulterants Per Pack remove8 Bucket Centrifuge removeLittle Sister Table Top Autoclave remove
ImageDrug Test Cup
SKUSF1033560130127-45SF1033560060-2SF1033560084-109SF1033560084-23SF1033560084-114SF1033560084-46
Rating
Price

$0.00

$0.00

$350.00

$0.00

$72.50

$1,350.00

Stock
Availability
Add to cart

DescriptionShipped From Abroad
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped from Abroad The skyla Hi POC Clinical Chemistry Analyzer provides clinical testing laboratories of medical facilities and clinics with an in-vitro clinical chemistry diagnostic tool that is compact, portable, and reports rapid results.The use of skyla Hi in the management of diabetes enables better access to testing and rapid clinical decision making, discussion,and implementation of optimized treatment. Delivery & Availability: Typically 14 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.In stock
  • Microprocessor control.
  • Digital display setting and actual temperature.
  • Over temperature alarm, PID self-tuning.
  • Digital display running timer.
  • Stainless steel interior.
  • Electricity leakage protection.
  • With glass inner door, With hidden door locks.
  • Mechanical overheat protection, cut off the heating sources.
  • Automatic alarm after operation.
  • Suitable for constant temperature tests.
  • Suitable for bacteria cultivation, breeding, ferment.
Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock
The Discover Cup is an all-in-one drug of abuse test cup. The strips are self-contained and the entire cup is tamper resistant. Delivery & Availability:
Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock
Classification: Laboratory Centrifuge
Brand Name: xiangtian
Model Number: 800-1
Place of Origin: Jiangsu, China
Time range: 0-60min
Max speed: 4000r/min
Max RCF: 1790xg
Capacity: 20ml*6
  Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Out stock Little Sister Table Top Autoclave: This sterilizer is a table type in safety and auto controlled,which is designed for the unit of medical health, pharmacy, science and technology and mostly suitable for sterilizing of surgical,dental and eye instruments, glassware medicine, culture medium and biological dressing, food and other goods. Delivery & Availability: Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Content
Deionized Water Purifier Features:
  1. The deionized water filter has power indicator, pump work indicator, low pressure indicator and system flushing indicator functions.
  2. Using imported ion filtration membranes and high-pressure, silent pure water pumps, the operation quality is more reliable and it is applicable to a wider range of water quality;
  3. It has system flushing function: every time before turning on the water machine, it will automatically flush for 30 seconds and then the system will start to make water;
  4. The water deionizer filter has system protection function: when the water pressure is too low or there is no water, the equipment automatically shuts down, and when the water source comes in, the equipment automatically turns on;
  5. WP-DU series deionized water filter has an online water quality monitoring function, which can monitor the incoming water quality (located above the instrument, near the function detection area, indicated by a digital tube), RO water quality and temperature, and pure water quality and temperature in real time.
 
Deionized Water Purifier Specifications:
Model WP-D20U WP-D30U WP-D40U WP-D50U WP-D60U
Water Output Speed 20L/h 30L/h 40L/h 50L/h 60L/h
Water Supply Requirement Tap water: TDS<200ppm; Water pressure>0.1Mpa;
Water temperature: 5-45℃
Pure Water Quality Conductivity 0.1us/cm (25℃)
PH Value (25℃) None
Oxidizable (Calculated as O) Technical requirements: ≦0.08mg/L;
Test results: ≦0.08mg/L
Evaporation Residue (105±2℃) Technical requirements: ≦1.0mg/L;
Inspection results: 0.7mg/L
Inspection Basis GB/T6682-2008
Consumption 25W
Control System Operation mode display: power, water shortage, flushing, full water, inlet water quality monitoring, RO water quality and temperature UP water quality and temperature, etc.
Safety Performance Automatically enters standby state when there is no water or low water pressure, and enters standby state when the system is full of water (constant pressure).
Purification System Pretreatment unit, external softening filter (recommended in places with high raw water hardness); 1μm deep PP filter element*2+precision activated carbon filter element
RO Reverse Osmosis Unit American original RO reverse osmosis membrane/membrane group
Post Purification Unit Purification column
Standard Accessories Host + accessory package
Shipping Size (WxDxH)(mm) 533x435x550
N.W/G.W 23kg/25kg 28kg/30kg 33kg/35kg
skyla Hi Analyzer enables better access to testing and rapid clinical decision making, discussion, and implementation of optimized treatment. To get the result, only prepare <1 μl fingertips blood or venous blood (depends on test item) without pretreatment with easy steps and then read the result after 6 mins. The device allows two specimens be tested in one run and provides fully automatic procedures from checking the validity of cartridge to printing the results. Reagent Kit
  • HbA1C
  • CRP
  • Lipid Panel (TC,TG, HDL, LDL#)
  • Lipid Plus Panel (Glu,TC,TG, HDL, LDL#)
Main Specification
Principle
Turbidimetric Method / Biochemistry
Device
Testing Time
5~20 minutes (depends on test items)
Display and Interface
5″ TFT color touch screen LCD
Memory Capacity
50,000 test results
Dimension of Analyzer
270 x 188 x 148 mm
Weight of Analyzer
1.7 kg
Dimension of Printer Module
134 x 100 x 82.7 mm
Weight of Printer Module
0.37 kg
Power Supply
100~240 volts AC, 50-60Hz
Data Transmission
USB 2.0*4 / USB 3.0*1 / RS232*1 / RJ45*1 / Wi-Fi (optional)
Reagent and Samples
Samples
Fingertips blood or venous blood
Samples Volume
0.8 ~ 30 μL (depends on test item)
Storage Temperature (Reagent)
2 ~ 8˚C
Humidity
Relative humidity < 95% (Non-condensing)
Temperature
10 ~ 32 ˚C
Click Here To Download Catalogue
Features:
  • Microprocessor control.
  • Digital display setting and actual temperature.
  • Over temperature alarm, PID self-tuning.
  • Digital display running timer.
  • Stainless steel interior.
  • Electricity leakage protection.
  • With glass inner door, With hidden door locks.
  • Mechanical overheat protection, cut off the heating sources.
  • Automatic alarm after operation.
  • Suitable for constant temperature tests.
  • Suitable for bacteria cultivation, breeding, ferment.
  Technical Specification: Model: IB-9025A Working size: 250x250x250mm/9.84x9.84x9.84inch Power: 150W Temperature range: Room temperature+5~65℃ Temperature resolution: 0.1℃ Temperature fluctuation: ±0.5℃ Timer: 0-9999min Voltage: 110V 60Hz / 220V 50Hz Dimension: 380x370x580mm/14.96x14.57x22.83inch Size: 52cm*46cm*75cm / 20.5in*18.2in*29.6in Gross Weight:42kg / 93lb Net Weight: 23kg / 51lb Warranty: 1 year
All-in-One Design
FDA 510K & CLIA Waived 99% Accurate Results in as little as 1 minute 24 Month Shelf Life from Date of Manufacture Secure, seal and send to lab for confirmation Built in temperature strip Available to test up to 14 substances Adulterants available
 
 
800-1  electric centrifuge is widely used in hospitals, chemical and Biological Chemistry Laboratory for serum, plasma, immune qualitative analysis experiment. Has beautiful shape, large capacity, small volume, complete function. Its performance is stable, the speed is adjustable and can automatically adjust the balance, low temperature, high efficiency and wide applicability and advantages. Technical Specifications:
Type No.
800-1
Power  source
220V 50HZ     110V  60HZ
Speed Range (rpm)
0~4000(rpm)
Time Range(min)
0-60min
Capacity (ml)
20(ml)×6
Maximum centrifugal force(xg)
1790(xg)
Package Size (cm)
29*29*26
 
Click Here To Download Catalogue
Little Sister Table Top Autoclave: This sterilizer is a table type in safety and auto controlled,which is designed for the unit of medical health, pharmacy, science and technology and mostly suitable for sterilizing of surgical,dental and eye instruments, glassware medicine, culture medium and biological dressing, food and other goods. Features:
  • Indicator light indicates working state.
  • For 4~6 minutes rapidly sterilizing.
  • Sterilizing temperature and time can be preset.
  • Steam-water inner circulation system: no steam discharge, and the environment for sterilizing will be clean and dry.
  • Over temperature & over pressure auto-protection.
  • Safe protection of water lacking.
  • Exhaust the cool air automatically.
  • With three stainless steel sterilizing plates.
  • The chamber of the sterilizer is made of stainless steel.
  • Automatically shut off with beep reminding after sterilization.
Technical Specifications:
   MODEL   MC-XB20J MC-XB24J

Sterilizing chamber volume

20L(φ250×420 mm) 24L(φ250×520 mm)
Maximum working pressure 0.22Mpa
Maximum working temperature 134℃
Adjustment of temperature 105-134℃
Timer 0-60 min
Chamber temperature equal ≤ ± 1℃
Source power 1.5KW/AC 220V 50Hz (AC110V 60HZ)
Sterilizing plate 340×200×30 mm (3 piece) 400×200×30 mm (3 piece)
Dimension 480×480×384 mm 580×480×384 mm
Package dimension 700×580×500 mm 800×580×500 mm
 G. W/N.W 44/40 kg

50/45 kg

   
 
 
WeightN/AN/AN/AN/AN/AN/A
DimensionsN/AN/AN/AN/AN/AN/A
Additional information
Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • Rating
  • Price
  • Description
Click outside to hide the comparison bar
Compare