DynaMesh-IPST

$0.00

Shipped From Abroad

DynaMesh®-IPSTDynaMesh®-IPST visibleDynaMesh®-IPST-D visibleDynaMesh®-IPST-R and DynaMesh®-IPST-R visible implants are intended for the surgical treatment of parastomal hernias, and the prevention (not DynaMesh®-IPST-R or DynaMesh®-IPST-R visible) of parastomal hernias following ostomy surgery, and permanently bridge and reinforce the soft tissue of the abdominal wall in the area of the stoma.

Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
SF1033560130161-6
Brands:: Dyna Mesh

Description

ipst-intraperitoneal

 

 

3D Funnel
The device has a passage point with a connected funnel for the passage of the intestine. The base area of the device must be positioned in contact with the tissue, as flat and smooth as possible, with the funnel pointing in the direction of the abdominal cavity.
When selecting the device, the diameter of the passage point should be chosen so that the intestine is tightly sheathed in the funnel.

 

 

 

 

Prefabricated Slit & Smooth Warp-Knitted Selvedges
Only DynaMesh®-IPST-R and DynaMesh®-IPST-R visible have a one-sided slit along the funnel and the base area (mesh flaps), starting from the passage point.
During positioning, the tight sheathing of the intestine in the funnel is achieved through appropriate overlapping of the mesh flaps with non-absorbable closure of the aperture.

 

Specifications
Product DynaMesh®-IPST (1)
DynaMesh®-IPST visible (2)
DynaMesh®-IPST-D visible (3)
DynaMesh®-IPST-R (4)
DynaMesh®-IPST-R visible (5)
Surgical Treatment Parastomal Hernia
(Repair / Prevention) (1) – (3) / (Repair) (4) (5)
Surgical Approach Minimally Invasive / Open
Surgical Technique Chimney Technique
Mesh Position Intraperitoneal
Fixation Suture / Tacks / No Fibrin Glue
Green Filament Ends
gruene_punkte
Smooth Warp-Knitted Selvedges graue_punkte (1) – (3) / gruene_punkte (4) (5)
Visible Technology
graue_punkte (1) (4) / gruene_punkte (2) (3) (5)
Materials – Polyvinylidene fluoride (PVDF) (CAS 24937-79-9) > 85% (w/w) (1) – (5)
– Polypropylene (PP) (CAS 9003-07-0) < 13% (w/w) (1) – (5)
– Phthalocyanine green (CAS 1328-53-6) < 1% (w/w) (1) – (5)
– Triiron tetraoxide (CAS 1317-61-9) < 1% (w/w) (2) (3) (5)
Polymers (Monofilament) PVDF, PP
Biocompatibility
gruene_punkte[TR1]
Ageing Resistance
gruene_punkte[2A, 5VIT, 27A, 52VIT, 93A, 101]
Effective Porosity
gruene_punkteHigh effective porosity reduces inflammation and the risk of excessive scar formation. [103P, TR71]
Klinge’s Mesh Classification Class 1a [102P, TR71B]
gruene_punkte Applies to all product sizes
gaue_punkte Does not apply
[#] Reference “#” (see “References”)
[TR#] Internal test report (see “internal test report references”)
Limitations “A” animal trial, “B” bench test, “VIT” in-vitro trial,
“P” published results based on the analysis of human mesh explants,
“PB” published results mainly based on bench tests

DynaMesh®-IPST implants (1)-(5) must be inserted via an appropriate minimally invasive or open approach and must be placed intraperitoneally.

DynaMesh®-IPST implants (1)-(5) have a parietal side and a visceral side. The parietal side is identified by green filament ends and consists of PVDF on the surface and a small proportion of PP, whereas the visceral side consists of PVDF on the surface.

When using DynaMesh®-IPST-D visible (3), attention must be paid to the side specificity (left-sided/right-sided stoma), through which a particularly large overlap in a cranial as well as in a medial direction is ensured.

When positioning DynaMesh®-IPST-R and DynaMesh®-IPST-R visible (4) (5), the tight sheathing of the intestine in the funnel is achieved through appropriate overlapping of the mesh flaps with non-absorbable closure of the aperture

Click here to download Catalogue.

Reviews

There are no reviews yet.

Be the first to review “DynaMesh-IPST”

Your email address will not be published. Required fields are marked *

Quick Comparison

DynaMesh-IPST removeOxygen Regulator (Japan Technology) removeDe Lineb Oxygen Face Mask removeMcKesson Sprague Rappaport Stethoscope removeBistos BT- 740 Patient Monitor removeAmbu Bag with Reservior remove
NameDynaMesh-IPST removeOxygen Regulator (Japan Technology) removeDe Lineb Oxygen Face Mask removeMcKesson Sprague Rappaport Stethoscope removeBistos BT- 740 Patient Monitor removeAmbu Bag with Reservior remove
ImageBistos BT- 740 Patient Monitor
SKUSF1033560130161-6SF1033560084-48SF1033560084-39SF1033560084-35SF1033560059-9SF1033560084-41
Rating
Price

$0.00

$17.00

$1.40

$17.00

$715.00

$17.00

Stock
Availability
Add to cart

DescriptionShipped From Abroad DynaMesh®-IPSTDynaMesh®-IPST visibleDynaMesh®-IPST-D visibleDynaMesh®-IPST-R and DynaMesh®-IPST-R visible implants are intended for the surgical treatment of parastomal hernias, and the prevention (not DynaMesh®-IPST-R or DynaMesh®-IPST-R visible) of parastomal hernias following ostomy surgery, and permanently bridge and reinforce the soft tissue of the abdominal wall in the area of the stoma.
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock
  • Full brass+chrome plated
  • Easy to read dual scal gauge with screw-on polycarbonate lens for durability.
  • Precision engineered pressure compensated design flowmeter for precise flow.
  • Flowmeter with easy to read tube and virtually unbreakable transparent polycarbonate outer cover for strength and 360 visibility.
  • Sintered metal inlet filter to trap impurities.
  • Reliable external safety relief valve.
  • Flush feature permits emergency oxygen to 40LPM.
Delivery & Availability: Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock
De Lineb Oxygen Face Mask: This mask provides a method to transfer breathing oxygen gas from a storage tank to the lungs. Oxygen masks may cover only the nose and mouth (oral nasal mask) or the entire face (full-face mask).
  Delivery & Availability: Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In Stock McKesson Sprague Rappaport Stethoscope: The McKesson Brand Two Sided Classic Nurse Stethoscope is an invaluable Diagnostic Instrument used by medical professionals when diagnosing heart, lung and vascular conditions. This high-quality stethoscope features an adjustable aluminum binaural, a single lumen 22-inch tube, a two-sided wide frequency chest piece, and comfortable ear tips.

Delivery & Availability:

Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped from Abroad Bistos BT - 740 Patient Monitor: Bistos Patient Vital Signs Monitor, ECG, Resp., SpO2, NIBP, Temp., BT-740. The Bistos BT-740 is a multi-parameter patient monitor with an 8.4" TFT Color screen. The standard paramaters are ECG, respiratory, SpO2, NIBP and temperature. Additional options are EtCO2, IBP, Multi-gas, CO and Masimo SpO2. The BT-740 has a fanless design for quiet operation. Delivery & Availability: Typically 7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.In stock
Ambu Bag with Reservior: The ventilation bag is highly reactive with fast recoil and excellent stroke volume which help relieving fatigue to the rescuer. The thin-walled compression bag provides an excellent feel of lung compliance and helps avoid excessive ventilation that could damage the lungs.
  Delivery & Availability: Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Content

ipst-intraperitoneal

    3D Funnel The device has a passage point with a connected funnel for the passage of the intestine. The base area of the device must be positioned in contact with the tissue, as flat and smooth as possible, with the funnel pointing in the direction of the abdominal cavity. When selecting the device, the diameter of the passage point should be chosen so that the intestine is tightly sheathed in the funnel.    

   

Prefabricated Slit & Smooth Warp-Knitted Selvedges Only DynaMesh®-IPST-R and DynaMesh®-IPST-R visible have a one-sided slit along the funnel and the base area (mesh flaps), starting from the passage point. During positioning, the tight sheathing of the intestine in the funnel is achieved through appropriate overlapping of the mesh flaps with non-absorbable closure of the aperture.

 
Specifications
Product DynaMesh®-IPST (1) DynaMesh®-IPST visible (2) DynaMesh®-IPST-D visible (3) DynaMesh®-IPST-R (4) DynaMesh®-IPST-R visible (5)
Surgical Treatment Parastomal Hernia (Repair / Prevention) (1) – (3) / (Repair) (4) (5)
Surgical Approach Minimally Invasive / Open
Surgical Technique Chimney Technique
Mesh Position Intraperitoneal
Fixation Suture / Tacks / No Fibrin Glue
Green Filament Ends
gruene_punkte
Smooth Warp-Knitted Selvedges graue_punkte (1) – (3) / gruene_punkte (4) (5)
Visible Technology
graue_punkte (1) (4) / gruene_punkte (2) (3) (5)
Materials – Polyvinylidene fluoride (PVDF) (CAS 24937-79-9) > 85% (w/w) (1) – (5) – Polypropylene (PP) (CAS 9003-07-0) < 13% (w/w) (1) – (5) – Phthalocyanine green (CAS 1328-53-6) < 1% (w/w) (1) – (5) – Triiron tetraoxide (CAS 1317-61-9) < 1% (w/w) (2) (3) (5)
Polymers (Monofilament) PVDF, PP
Biocompatibility
gruene_punkte[TR1]
Ageing Resistance
gruene_punkte[2A, 5VIT, 27A, 52VIT, 93A, 101]
Effective Porosity
gruene_punkteHigh effective porosity reduces inflammation and the risk of excessive scar formation. [103P, TR71]
Klinge’s Mesh Classification Class 1a [102P, TR71B]
gruene_punkte Applies to all product sizes
gaue_punkte Does not apply
[#] Reference “#” (see “References”)
[TR#] Internal test report (see “internal test report references”)
Limitations “A” animal trial, “B” bench test, “VIT” in-vitro trial, “P” published results based on the analysis of human mesh explants, “PB” published results mainly based on bench tests
DynaMesh®-IPST implants (1)-(5) must be inserted via an appropriate minimally invasive or open approach and must be placed intraperitoneally. DynaMesh®-IPST implants (1)-(5) have a parietal side and a visceral side. The parietal side is identified by green filament ends and consists of PVDF on the surface and a small proportion of PP, whereas the visceral side consists of PVDF on the surface. When using DynaMesh®-IPST-D visible (3), attention must be paid to the side specificity (left-sided/right-sided stoma), through which a particularly large overlap in a cranial as well as in a medial direction is ensured. When positioning DynaMesh®-IPST-R and DynaMesh®-IPST-R visible (4) (5), the tight sheathing of the intestine in the funnel is achieved through appropriate overlapping of the mesh flaps with non-absorbable closure of the aperture

Click here to download Catalogue.

  • Full brass+chrome plated
  • Easy to read dual scale gauge with screw-on poly carbonate lens for durability.
  • Precision engineered pressure compensated design flow meter for precise flow.
  • Flow meter with easy to read tube and virtually unbreakable transparent poly carbonate outer cover for strength and 360 visibility.
  • Sintered metal inlet filter to trap impurities.
  • Reliable external safety relief valve.
  • Flush feature permits emergency oxygen to 40LPM.
         
 
 
De Lineb Oxygen Face Mask: This mask provides a method to transfer breathing oxygen gas from a storage tank to the lungs. Oxygen masks may cover only the nose and mouth (oral nasal mask) or the entire face (full-face mask).
Features:
  • Non-toxic PVC
  • Medium concentration
  • Adjustable nose clip
  • Non-Autoclavable
  • Available size: adult, child
  Technical Specifications:
  • Product Name: Oxygen Mask
  • Material: Medical grade PVC
  • Color: Green
  • Size: S, M, L, L , XL
  • Package: PE bag
  • Tube size: 2m
  • Nose Clip: adjustable
  • Disposable Medical Oxygen Face Mask Types MSLMK01
 
McKesson Sprague Rappaport Stethoscope: The McKesson Brand Two Sided Classic Nurse Stethoscope is an invaluable Diagnostic Instrument used by medical professionals when diagnosing heart, lung and vascular conditions. This high-quality stethoscope features an adjustable aluminum binaural, a single lumen 22-inch tube, a two-sided wide frequency chest piece, and comfortable ear tips. Features
  • McKesson Dual-Head Scope – Black
  • Lightweight combination diaphragm/bell chestpiece for wide frequency response.
  • Proprietary diaphragm enhances acoustic response by 50% over traditional designs.
  • Non-chill bell ring and diaphragm rims.
  • Adjustable aluminum binaurals with PVC eartips.
  • 21 inch PVC tubing.
  • Weighs 4 oz.
  • Overall length 32-1/4 inches.
  • Not Made with Natural Rubber Latex.
 Technical Specification
  • Bell Size: 0 – 3/5 Inch Bell
  • Binaurals Material: Adjustable Aluminum Binaurals
  • Chestpiece Material: Aluminum Chestpiece
  • Diaphragm Diameter: 1-3/4 Inch Diaphragm
  • Ear Pieces Type: 1 Pair PVC Ear Tips , 1 Pair Black Mushroom Ear Tips
  • Head Type: Double-Sided Chestpiece
  • Number of Tubes: 1 – Tube
  • Tube Length: 22 Inch Tube
  • Tube Type: Single Lumen
  • Latex Free Indicator: Not Made with Natural Rubber Latex
Bistos BT - 740 Patient Monitor: Bistos Patient Vital Signs Monitor, ECG, Resp., SpO2, NIBP, Temp., BT-740. The Bistos BT-740 is a multi-parameter patient monitor with an 8.4" TFT Color screen. The standard paramaters are ECG, respiratory, SpO2, NIBP and temperature. Additional options are EtCO2, IBP, Multi-gas, CO and Masimo SpO2. The BT-740 has a fanless design for quiet operation. Features:
  • 8.4" TFT Color Screen - (Optional Touch Screen Upgrade)
  • Standard parameters are ECG, Resp., SpO2, NIBP, Temp.
  • Ultra-low power consumption
  • Quiet operation
  • High accuracy SpO2 reading
  • Data transfer or firmware upgrade via USB
  • 2 Years Manufacturer's Warranty
  Technical Specifications:
Model BT-740
Display 8.4" Color TFT Screen
ECG Lead type 3/5 Lead
Gain Selection x0.25, x0.5, x1, x2, x4, auto
Sweep speed (mm/s) 12.5, 25, 50
Bandwith:(Diagnostic Mode) 0.05-130Hz
Monitoring Mode 0.5-40Hz
Surgery Mode 1-25Hz
Strong Mode 5-20Hz
Heart Rate Range (bpm) Adult:15-300
Pediatric/neonate: 15-350
Respiration Method Trance-thoracic Impedance
Measurement Range 0-120rpm
Sweep Speed (mm/s) 6.25, 12.5, 25
SpO2 Measurement Range 0-100%
Accuracy (70-100%) Adult/Pediatric +/-2%
Neonate +/-3%
Accuracy (0-69%) Unspecified
Perfusion Index 0.05-20%
Pulse Rate Range (bpm) 25-250bpm
NIBP** Method Automatic (Oscillometric)
Operation Mode Manual/Auto/STAT
Parameter Systolic, Diastolic, Mean
Systolic Range (mmHg) Adult 40-270
Pediatric 40-200
Neonate 40-130
Diastolic Range (mmHg) Adult 10-210
Pediatric 10-160
Neonate 10-90
Mean Range (mmHg) Adult 20-230
Pediatric 20-175
Neonate 20-100
Temperature Range 0-50°C
Parameter T1, T2 and TD
IBP" Channel 2 Channel, 4 Channel
Range (mmHg) -50-400
Printer* Type Thermal dot array
Print Speed (mm/s) 12.5, 25, 50
Paper Size (mm) 50
CO2* Sidestream Masimo ISA / Bistos
Mainstream Masimo IRMA / Bistos
Multi-gas O2* Masimo ISA
SpO2 Masimo* Masimo SpO2
CO* Method Thermodilution
Range 0.2-20 L/min
Battery Type (Capacity) Li-ion (440mAh)
Run Time 6 hour
Charging Time 4 hour
Interface RJ45, USB, Nursing Call
Warranty 2 Years
 
Click Here To Download Catalogue
 
Ambu Bag with Reservior: The ventilation bag is highly reactive with fast recoil and excellent stroke volume which help relieving fatigue to the rescuer. The thin-walled compression bag provides an excellent feel of lung compliance and helps avoid excessive ventilation that could damage the lungs.
Features:
  • Brand: OEM
  • Item No.: AM-DMR-M06-0/1/4
  • Color: Green
  • Size: Adult/Pediatric/Infant
  • Material: Disposable
  • Application: Emergency Resuscitation
  • MOQ: 300
  • Lead Time: 60 days
  • Shipping Terms: FOB
  • Packaging Details: Each set is packed into a white PP box
  • Carton Size: 57 x 34 x 46 CM / 12 SETS
  • Shipping Weight: 9.8 Kilos
  Technical Specifications:
Type Infant Pediatric Adult
Patient weight ≤10kg 10kg-40kg >40kg
Stroke volume 150ml 400ml 800ml
Resuscitator volume 280ml 600ml 1650ml
Dimensions L x D 135 x 75mm 146 x 100mm 212 x 131mm
Resuscitator weight 350g 410g 600g
Pressure limiting valve 40cmH2O 40cmH2O 60cmH2O
Inspiratory resistance <5cmH2O (at 50L/min)
Expiratory resistance <5cmH2O (at 50L/min)
Bag volume 1600ml 1600ml 2000ml
Patient connector ISO5356-1:φ22/15mm Male/Female
Recommended operating temperature -18℃~+50℃
Storage Tested at -40℃ and 60℃
 
 
WeightN/AN/AN/AN/AN/AN/A
DimensionsN/AN/AN/AN/AN/AN/A
Additional information
Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • Rating
  • Price
  • Description
Click outside to hide the comparison bar
Compare