DynaMesh®-SIS direct, DynaMesh®-SIS direct soft, and DynaMesh®-SIS direct visible implants are intended to be used as a mid-urethral sling for the surgical treatment of stress urinary incontinence caused by a hypermobile urethra and/or intrinsic sphincter deficiency. The devices permanently reinforce the soft tissue of the pelvic floor.

Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
SF1033560130161-8
Brands:: Dyna Mesh

Description



Retropubic Tape Position
(Inside-Out)

DM-SIS-retrosymphysary

 

Transobturator Tape Position
(Outside-In or Inside-Out)

DM-SIS-transobturatoric

 

DynaMesh®-SISDynaMesh®-SIS soft and DynaMesh®-SIS visible are positioned using the inside-out technique in case of a retropubic tape position, and using the outside-in or inside-out technique in case of a transobturator tape position.


The devices have a thread at the ends of the tape that is attached to the surgical instrument.

 

Several reusable instruments are available separately to position the device:

DynaMesh®-ISR01:
Instrument for transvaginal access for retropubic positioning of DynaMesh®-SIS, DynaMesh®-SIS soft and DynaMesh®-SIS visible using the inside-out technique.


Diameter: 5-7 cm

DynaMesh®-IST01 / DynaMesh®-IST02 / DynaMesh®-IST03:
Instrument set consisting of two instruments for transvaginal access for transobturator positioning of DynaMesh®-SIS, DynaMesh®-SIS soft and DynaMesh®-SIS visible using the inside-out or outside-in technique.

DynaMesh®-IVT01:
Instrument for transvaginal access for transobturator positioning of DynaMesh®-SIS, DynaMesh®-SIS soft and DynaMesh®-SIS visible using the outside-in technique.

Specifications
Product DynaMesh®-SIS (1)
DynaMesh®-SIS soft (2)
DynaMesh®-SIS visible (3)
Surgical Treatment Stress Urinary Incontinence (SUI)
Surgical Approach Transvaginal
Surgical Technique TVT – Retropubic – Inside-Out /
TOT – Transobturator – Outside-In
Fixation None
Smooth Warp-Knitted Selvedges
gruene_punkte
Shape Stability
gruene_punkte[TR12, TR13]
Defined Elasticity
gruene_punkte[TR10]
Visible Technology
graue_punkte (1) (2) / gruene_punkte (3)
Materials
– Polyvinylidene fluoride (PVDF) (CAS 24937-79-9) > 99% (w/w) (1) – (3)
– Phthalocyanine green (CAS 1328-53-6) < 1% (w/w) (1) (2)
– Triiron tetraoxide (CAS 1317-61-9) < 1% (w/w) (3)
Polymer (Monofilament)
PVDF
Biocompatibility
gruene_punkte[TR1]
Ageing Resistance
gruene_punkte[2A, 5VIT, 27A, 52VIT, 93A, 101]
Effective Porosity gruene_punkte  High effective porosity reduces inflammation and the risk of excessive scar formation. [103P, TR11]
Klinge’s Mesh Classification Class 1a  [102P, TR11]

 

Click here to download Catalogue

Reviews

There are no reviews yet.

Be the first to review “DynaMesh-SIS direct”

Your email address will not be published. Required fields are marked *

Quick Comparison

DynaMesh-SIS direct removeSpinal Epidural Pack removePortable Stainless Steel Autoclave Sterilizer removeAmbu Oval Silicone resuscitator (Ambu Bag) removeAmbu Bag with Reservior removeLittmann Classic III Stethoscope remove
NameDynaMesh-SIS direct removeSpinal Epidural Pack removePortable Stainless Steel Autoclave Sterilizer removeAmbu Oval Silicone resuscitator (Ambu Bag) removeAmbu Bag with Reservior removeLittmann Classic III Stethoscope remove
ImageLittmann Classic III Stethoscope
SKUSF1033560130161-8SF1033560084-25SF1033560084-4SF1033560084-62SF1033560084-41SF1033560084-34
Rating
Price

$0.00

$0.00

$216.00

$27.00

$17.00

$34.00

Stock

In stock

AvailabilityIn stock
Add to cart

DescriptionShipped From Abroad DynaMesh®-SIS direct, DynaMesh®-SIS direct soft, and DynaMesh®-SIS direct visible implants are intended to be used as a mid-urethral sling for the surgical treatment of stress urinary incontinence caused by a hypermobile urethra and/or intrinsic sphincter deficiency. The devices permanently reinforce the soft tissue of the pelvic floor.
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In Stock It is for performing spinal/epidural or combined spinal/epidural or never-block loco-regional anaesthesia on patinet in clinical surgery.

Delivery & Availability:

Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In Stock
  • Can be set as required sterilization temperature, working tem. range:room tem.:+5~126 Degree.
  • Can ge set as required sterilization time of heat preservation, setting range:1~99min.
  • Having a low water to stop heating function.
  • This product uses the high quality stainless steel SUS304. Having to work under normal conditions adequate safety strength.
Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In Stock The Ambu Oval Silicone resuscitator is designed for manual ventilation of neonates though to adults. Delivery & Availability: Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.In stock
Ambu Bag with Reservior: The ventilation bag is highly reactive with fast recoil and excellent stroke volume which help relieving fatigue to the rescuer. The thin-walled compression bag provides an excellent feel of lung compliance and helps avoid excessive ventilation that could damage the lungs.
  Delivery & Availability: Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In Stock The Classic III stethoscope brings new design, materials, and technology to the Littmann stethoscope series that’s been used and trusted by millions of medical professionals worldwide for decades. With a two-sided chestpiece, dual tunable diaphragms, improved tubing, and much more, the Classic III stethoscope combines the best of new and traditional.

Delivery & Availability:

Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Content


Retropubic Tape Position (Inside-Out)

DM-SIS-retrosymphysary

 
Transobturator Tape Position (Outside-In or Inside-Out)

DM-SIS-transobturatoric

 
DynaMesh®-SISDynaMesh®-SIS soft and DynaMesh®-SIS visible are positioned using the inside-out technique in case of a retropubic tape position, and using the outside-in or inside-out technique in case of a transobturator tape position.

The devices have a thread at the ends of the tape that is attached to the surgical instrument.
 
Several reusable instruments are available separately to position the device:

DynaMesh®-ISR01: Instrument for transvaginal access for retropubic positioning of DynaMesh®-SIS, DynaMesh®-SIS soft and DynaMesh®-SIS visible using the inside-out technique.

Diameter: 5-7 cm

DynaMesh®-IST01 / DynaMesh®-IST02 / DynaMesh®-IST03: Instrument set consisting of two instruments for transvaginal access for transobturator positioning of DynaMesh®-SIS, DynaMesh®-SIS soft and DynaMesh®-SIS visible using the inside-out or outside-in technique.

DynaMesh®-IVT01: Instrument for transvaginal access for transobturator positioning of DynaMesh®-SIS, DynaMesh®-SIS soft and DynaMesh®-SIS visible using the outside-in technique.

Specifications
Product DynaMesh®-SIS (1) DynaMesh®-SIS soft (2) DynaMesh®-SIS visible (3)
Surgical Treatment Stress Urinary Incontinence (SUI)
Surgical Approach Transvaginal
Surgical Technique TVT – Retropubic – Inside-Out / TOT – Transobturator – Outside-In
Fixation None
Smooth Warp-Knitted Selvedges
gruene_punkte
Shape Stability
gruene_punkte[TR12, TR13]
Defined Elasticity
gruene_punkte[TR10]
Visible Technology
graue_punkte (1) (2) / gruene_punkte (3)
Materials
– Polyvinylidene fluoride (PVDF) (CAS 24937-79-9) > 99% (w/w) (1) – (3) – Phthalocyanine green (CAS 1328-53-6) < 1% (w/w) (1) (2) – Triiron tetraoxide (CAS 1317-61-9) < 1% (w/w) (3)
Polymer (Monofilament)
PVDF
Biocompatibility
gruene_punkte[TR1]
Ageing Resistance
gruene_punkte[2A, 5VIT, 27A, 52VIT, 93A, 101]
Effective Porosity gruene_punkte  High effective porosity reduces inflammation and the risk of excessive scar formation. [103P, TR11]
Klinge’s Mesh Classification Class 1a  [102P, TR11]
 

Click here to download Catalogue

It is for performing spinal/epidural or combined spinal/epidural or never-block loco-regional anaesthesia on patinet in clinical surgery. Component:
  • Epidural needle 16G,
  • Epidural catheter,
  • Epidural filter 0.2 um,
  • Catheter connector,
  • LOR syringe
Features:
  • Can be set as required sterilization temperature, working tem. range:room tem.:+5~126 Degree.
  • Can ge set as required sterilization time of heat preservation, setting range:1~99min.
  • Having a low water to stop heating function.
  • This product uses the high quality stainless steel SUS304. Having to work under normal conditions adequate safety strength.
Technical Specifications:
Model No.: YX280A
Sterilizing volume 18L
Working pressure 0.14-0.16Mpa
Working temperature 126ºC
Max. safety pressure 0.165Mpa
Characteristics Electric heated
The Ambu Oval Silicone resuscitator is designed for manual ventilation of neonates though to adults. Features
  • The Ambu Oval Silicone resuscitator has a special textured surface combined with the unique support strap to ensures that a comfortable and firm grip is guaranteed, allowing for effective ventilation over extended periods, without the problem of hand fatigue.
  • The Ambu Oval Silicone Resuscitators is made out of a view parts that can be disassembled easily. The Ambu Oval Silicone Resuscitator can easy be cleaned and autoclaved (except the oxygen reservoir) at a temperature of 134° Celsius.
  • The unique shape is small and easy to hold. The ergonomic, lightweight design of Ambu Oval Silicone Resuscitator is made for optimal user handling and support even during extended ventilations.
  • The resuscitators are semi-transparent allowing for a visual check of the patient’s condition. A pressure limitation valve is optional for the adult version and has been included into the design of the pediatric versions to ensure the safety of the patient*.

* International guidelines recommend that all manual resuscitators for infant and pediatric patients should be equipped with a pressure limitation mechanism so the airway pressure does not exceed 45 cm H2O.

Ambu Bag with Reservior: The ventilation bag is highly reactive with fast recoil and excellent stroke volume which help relieving fatigue to the rescuer. The thin-walled compression bag provides an excellent feel of lung compliance and helps avoid excessive ventilation that could damage the lungs.
Features:
  • Brand: OEM
  • Item No.: AM-DMR-M06-0/1/4
  • Color: Green
  • Size: Adult/Pediatric/Infant
  • Material: Disposable
  • Application: Emergency Resuscitation
  • MOQ: 300
  • Lead Time: 60 days
  • Shipping Terms: FOB
  • Packaging Details: Each set is packed into a white PP box
  • Carton Size: 57 x 34 x 46 CM / 12 SETS
  • Shipping Weight: 9.8 Kilos
  Technical Specifications:
Type Infant Pediatric Adult
Patient weight ≤10kg 10kg-40kg >40kg
Stroke volume 150ml 400ml 800ml
Resuscitator volume 280ml 600ml 1650ml
Dimensions L x D 135 x 75mm 146 x 100mm 212 x 131mm
Resuscitator weight 350g 410g 600g
Pressure limiting valve 40cmH2O 40cmH2O 60cmH2O
Inspiratory resistance <5cmH2O (at 50L/min)
Expiratory resistance <5cmH2O (at 50L/min)
Bag volume 1600ml 1600ml 2000ml
Patient connector ISO5356-1:φ22/15mm Male/Female
Recommended operating temperature -18℃~+50℃
Storage Tested at -40℃ and 60℃
 
 
The Classic III stethoscope brings new design, materials, and technology to the Littmann stethoscope series that’s been used and trusted by millions of medical professionals worldwide for decades. With a two-sided chestpiece, dual tunable diaphragms, improved tubing, and much more, the Classic III stethoscope combines the best of new and traditional. Full adult and pediatric auscultation is available through its dual head chestpiece simply by rotating the central spline to alternate between the two sides. The more compact one piece diaphragm and rim assemblies have further increased acoustic sensitivity. The binaurals have been redesigned with larger diameter ear tubes and a thicker single lumen binaural to transfer sound more effectively. The selector spline is now recessed to allow a flush fit with the binaural tube and now features a visual indicator for easy identification of the operational diaphragm. Features
  • NEW: double-sided, dual diaphragm chestpiece for both adult and paediatric assessment.
  • NEW: The paediatric side is also easily transformed into a traditional open bell by replacing the single-piece diaphragm with the supplied non-chill rim.
  • NEW: chestpiece is precision-machined into an aesthetically pleasing, less angular shape.
  • NEW: single-piece diaphragm instead of separate diaphragm/rim making it easier to attach and easier to clean due to the smooth unbroken surface.
  • NEW: The stem features an open side indicator to easily identify which diaphragm is in operation.
  • NEW: next-generation tubing gives even longer tube life with improved resistance to skin oils, alcohol and staining.
  • 3M’s ‘Tunable Technology’ lets you easily switch from low to high frequency sounds by switching from light to firm pressure on both the adult and paediatric sides of the chestpiece.
  • High acoustic sensitivity when performing general physical assessment.
  • Laser engraving of text and symbols to personalise your scope and avoid theft/loss
  • Larger ear tubes on the anatomically designed headset comfortably positioned for better sound transfer. Easy adjustment by simply squeezing or pulling apart the eartubes.
  • Comfortable Snap-Tight soft seal eartips create an excellent acoustic seal to reduce ambient noise.
  • No natural rubber latex or phthalate plasticisers are used in the tubing or any other component—to help protect health and the environment.
  • Complement your personal style with Littmann’s large range of chestpiece finishes and tubing colours.
  • Used as a diagnostic aid as part of the physical assessment of a patient.
WeightN/AN/AN/AN/AN/AN/A
DimensionsN/AN/AN/AN/AN/AN/A
Additional information
Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • Rating
  • Price
  • Description
Click outside to hide the comparison bar
Compare