Electrosurgical Pad

$0.00

Shipped From Abroad

Electrosurgical Pad, also known as a dispersive electrode or grounding pad, is a crucial component used in electrosurgery. It helps to complete the electrical circuit by dispersing the electrical current away from the patient’s body, ensuring the safety and effective operation of the electrosurgical unit (ESU)

Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
SF1033560130165-16
Brands:: OBS

Description

 

Features:
  1. High Conductivity: They are made from materials that ensure efficient conduction of electrical current.
  2. Large Surface Area: This helps in dispersing the current over a wide area, reducing the risk of burns.
  3. Adhesive Backing: They usually have an adhesive side to securely attach to the patient’s skin.
  4. Flexible Design: They are designed to conform to the contours of the patient’s body.
  5. Safety Mechanisms: Modern pads often include features like dual-pad return electrodes for fail-safe operation.
Uses:
  1. Completing the Electrical Circuit: They act as a return path for the electrical current used in electrosurgery.
  2. Minimizing Burns: By dispersing the current, they help prevent burns at the surgical site.
  3. Ensuring Patient Safety: They are crucial for the safe operation of electrosurgical units, especially in patients with electronic implants like pacemakers.
  4. Versatile Applications: Used in various surgical procedures, including cutting, coagulating, and desiccating tissue.

Reviews

There are no reviews yet.

Be the first to review “Electrosurgical Pad”

Your email address will not be published. Required fields are marked *

Quick Comparison

SettingsElectrosurgical Pad removeElectrosurgical Bipolar Forceps removeElectrotherapy Electrode with Cables removeBipolar Artery Forceps removeOBS-50 High Frequency Coagulator removeOBS-100C(I) Intelligent Electrosurgical Unit remove
NameElectrosurgical Pad removeElectrosurgical Bipolar Forceps removeElectrotherapy Electrode with Cables removeBipolar Artery Forceps removeOBS-50 High Frequency Coagulator removeOBS-100C(I) Intelligent Electrosurgical Unit remove
Image
SKUSF1033560130165-16SF1033560130165-18SF1033560130165-23SF1033560130165-20SF1033560130165-3SF1033560130165-2
Rating
Price

$0.00

$0.00

$0.00

$0.00

$0.00

$0.00

Stock
Availability
Add to cart

DescriptionShipped From Abroad Electrosurgical Pad, also known as a dispersive electrode or grounding pad, is a crucial component used in electrosurgery. It helps to complete the electrical circuit by dispersing the electrical current away from the patient's body, ensuring the safety and effective operation of the electrosurgical unit (ESU)
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad Electrosurgical Bipolar Forceps are specialized surgical instruments used in electrosurgery. They have two electrodes at the tips, which allow for precise control of electrical current to coagulate, cut, or seal tissue with minimal damage to surrounding areas.
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad This unit is widely used in many different sectors including plastic surgery, dermatology, ENT, Ophthalmology, somatology, gynecology, proctology, and urology.
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad Portable in size, available in both monopolar and bipolar modes, convenient handle power control and memory function, suitable for microsurgery, gynecology, and arthroscopy.
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Content  
Features:
  1. High Conductivity: They are made from materials that ensure efficient conduction of electrical current.
  2. Large Surface Area: This helps in dispersing the current over a wide area, reducing the risk of burns.
  3. Adhesive Backing: They usually have an adhesive side to securely attach to the patient's skin.
  4. Flexible Design: They are designed to conform to the contours of the patient's body.
  5. Safety Mechanisms: Modern pads often include features like dual-pad return electrodes for fail-safe operation.
Uses:
  1. Completing the Electrical Circuit: They act as a return path for the electrical current used in electrosurgery.
  2. Minimizing Burns: By dispersing the current, they help prevent burns at the surgical site.
  3. Ensuring Patient Safety: They are crucial for the safe operation of electrosurgical units, especially in patients with electronic implants like pacemakers.
  4. Versatile Applications: Used in various surgical procedures, including cutting, coagulating, and desiccating tissue.
 
Features:
  1. Two Electrodes: The tips of the forceps act as both the active and return electrodes.
  2. Precision Control: Allows for targeted application of electrical energy.
  3. Reduced Risk of Burns: The current is confined between the forceps, minimizing the risk of accidental burns.
  4. Reusable: Often made from stainless steel or titanium and can be sterilized for multiple uses.
  5. Variety of Designs: Available in straight, angled, and bayonet styles to suit different surgical needs.
Uses:
  1. Coagulation: Used to stop bleeding by coagulating blood vessels.
  2. Tissue Cutting: Can be used to cut tissue with precision.
  3. Sealing: Effective in sealing blood vessels and tissue bundles.
  4. Versatility: Used in various surgical fields such as general surgery, gynecology, neurosurgery, and ENT (Ear, Nose, and Throat) surgery.
Electrotherapy electrodes with cables are used to connect the electrodes to the electrotherapy device, allowing electrical currents to be delivered to the targeted area. These cables typically have a standard 2mm pin connector that plugs into the device and the electrodes. There are different types of cables available, such as:
  • Standard Lead Wires: These are the basic cables that come with most electrotherapy units.
  • Bifurcation Cables: These cables allow you to connect multiple electrodes to a single channel, effectively doubling the number of electrodes you can use.
  • Extended Length Cables: These are longer cables that provide more flexibility in positioning the electrodes.
  The OBS-50 is a market leader across the world due to its ease of use, high security, power on self test, full-range monitoring, remote control and precise output.
  • Power output can be controlled by the easy to use power adjustment button on the electrosurgical hand pencil which can shorten the operation time.
  • With the inbuilt memory function on the device, you can set the required function parameters then power off the unit, next time the unit is powered on, the unit the last set parameter will be displayed.
  • Output power of between 10 and 30 watts or less can be adjusted up and down by 0.1-watt increments, which is suitable for various delicate procedures.
  • It can be used with disposable dispersive electrode
 What's in the box?
  • x1 OBS-50 High-Frequency Electric Coagulator Unit
  • x1 Reusable power control electrosurgical pencil
  • x10 Non-Sterile Single-Use Short Sharp Tips
  • x10 Non-Sterile Single-Use Short Blunt Tips
  • x1 Power cord
  • x1 Instruction manual
Multiple Applications to meet your different clinic demands
Desiccation 
  • Monopolar output mode without using the dispersive electrode
  • Contact or insert into the tissue with the electrode
  • The unit produces a high-frequency current, which runs through the patient via the electrode and then returns to the unit through grounding.
  • High-frequency current vaporises the liquid inside the tissue cell therefore causing denaturation on the protein
Fulguration
  • Another monopoly output mode without using a dispersive electrode
  • Holding the electrode above the lesions rather than contact directly, will release an electric arc to the tissue.
  • Range of action in this mode is limited to the surface where the arc contacts the tissue
Coagulation
  • Suitable for hemostasis and shrinkage of tissue
  • Used in control of hemostasis
  • Suitable for more difficult cutting procedures for good hemostasis
Monopolar coagulation
  • Monopolar output mode using the dispersive electrode
  • Under this mode, the high-frequency current that is produced from the unit flows through the patient and then returns to the unit via a dispersive electrode
  • The dispense electrode can draw more high-frequency current to the electrode, making the tip of electrode produce a more powerful desiccation to the tissue.
Bipolar Coagulation
  • An Output mode in which the high-frequency current circulates between two nearby electrodes (bipolar forceps), without using the dispersive electrode.
  • In contrast to the effect of monopolar coagulation, since the high-frequency current is only circulated separately in the forceps, the bipolar coagulation effect acts only on the tissue surface, causing minimal damage to the tissue.
Standard Accessories (Can be purchased Separately)
  • Single foot switch
  • Reusable power control electrosurgical pencil
  • Reusable dispersive electrode (Patient Plate) & Cable
  • Reusable bipolar forceps & cable
  • Reusable Connecting Cable (for disposable dispersive electrode)
  • Disposable dispersive electrodes
  • Wall mounting Plate
Output Mode  Monopolar coagulation: (30W, load:1000Ω) Bipolar coagulation: (30W, load:200Ω) Technical parameters
Ambient Temperature  10°C - 40°C
RH Range ≤80%
atmospheric pressure range 50.0kPa-106.0kPa
Power supply 220/110V,50/60Hz
operating Frequency 550kHz+10%
 
Key Features
OBS-100 Electrosurgical Generator with state-of-art technology offers superb performance on the electro-surgery, and shows remarkable safety, reliability and convenience. 1. Two levels of coagulation: pinpoint coagulation and fulguration Pinpoint coagulation provides precise control of bleeding in localized areas. Fulguration provides greater control of bleeding in highly vascular over-surface areas. 2. Presets The unit incorporates as many as ten user-defined presets for easy recall of frequency and settings. 3. Isolated RF output for Cut, Blend, and Coag modes This minimizes the potential of alternate site burns. 4. Ground Referenced RF output for Fulguration modes 5. Self-diagnostics These diagnostics continually monitor the unit to ensure proper performance. If the diagnostics is unsuccessful, the warning tones can be heard.
Technical parameters:
Environmental temperature range: 5°C~ 40°C
Relative moisture range: ≤80%
Atmosphere pressure range: 86.0 ~ 106.0 Kpa
 Working modes:
Pure cut: 1w ~ 60w (Load 500Ω)
Blend: 1w ~ 60w (Load 800Ω)
Coagulation: 1w ~ 60w (Load 1000Ω)
Fulguration: 0.1w ~ 35w (Load 1000Ω)
Bipolar: 1w ~ 30w (Load 200Ω)
Technology data:
Voltage: 220V±10V, 50Hz ±1Hz
Working frequency: 357 KHz ~ 575 KHz
Leakage currents to ground: Less than 0.5mA
Leakage currents to patient: Less than 0.01mA
Display Setting: Fulguration a.      0-10 range: 0.1watt increments b.      10-35range: 1.0 watt increments Cut, Blend, Coagulation, and Bipolar 1.0-watt increments Power supply:220V±10%,50±1%Hz. Transportation and storage a)        Ambient temperature range: -40°C~55°C; b)        Relative moisture range: ≤95%; c)        Atmosphere pressure range: 500hPa~1060hPa. Accessories Included: Electrosurgical Pencil, disposable                           2pcs Bipolar Forceps with cable, reusable                      1pc Disposable Electrosurgical Pad                               2pcs Cable for Electrosurgical Pad, reusable                  1pc Footswitch                                                              1pc Power cord                                                             1pc Manual                                                                    1pc
WeightN/AN/AN/AN/AN/AN/A
DimensionsN/AN/AN/AN/AN/AN/A
Additional information
Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • Rating
  • Price
  • Description
Click outside to hide the comparison bar
Compare