Electrotherapy electrodes are an essential component of electrotherapy treatments, which use electrical currents to manage pain, improve circulation, repair tissues, and strengthen muscles. These electrodes are typically adhesive pads that stick to the skin and deliver mild electrical pulses to the targeted area

Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
SF1033560130165-22
Brands:: OBS

Reviews

There are no reviews yet.

Be the first to review “Electrotherapy Electrode”

Your email address will not be published. Required fields are marked *

Quick Comparison

SettingsElectrotherapy Electrode removeOBS-100C(I) Intelligent Electrosurgical Unit removeReusable Electrosurgical Pencil removeReusable Silicon Electrosurgical Pad removeElectrotherapy Electrode with Cables removeBipolar Irrigated Coagulator remove
NameElectrotherapy Electrode removeOBS-100C(I) Intelligent Electrosurgical Unit removeReusable Electrosurgical Pencil removeReusable Silicon Electrosurgical Pad removeElectrotherapy Electrode with Cables removeBipolar Irrigated Coagulator remove
Image
SKUSF1033560130165-22SF1033560130165-2SF1033560130165-11SF1033560130165-17SF1033560130165-23SF1033560130165-12
Rating
Price

$0.00

$0.00

$0.00

$0.00

$0.00

$0.00

Stock
Availability
Add to cart

DescriptionShipped From Abroad Electrotherapy electrodes are an essential component of electrotherapy treatments, which use electrical currents to manage pain, improve circulation, repair tissues, and strengthen muscles. These electrodes are typically adhesive pads that stick to the skin and deliver mild electrical pulses to the targeted area
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad Portable in size, available in both monopolar and bipolar modes, convenient handle power control and memory function, suitable for microsurgery, gynecology, and arthroscopy.
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad Reusable Silicon Electrosurgical Pad is a grounding pad made from medical-grade silicone. It's designed for use in electrosurgery to disperse electrical current safely. It features a large surface area, adhesive backing, and connectors for attachment to electrosurgical units. This pad can be sterilized and reused, making it cost-effective and suitable for various surgical procedures.
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Content  
Key Features
OBS-100 Electrosurgical Generator with state-of-art technology offers superb performance on the electro-surgery, and shows remarkable safety, reliability and convenience. 1. Two levels of coagulation: pinpoint coagulation and fulguration Pinpoint coagulation provides precise control of bleeding in localized areas. Fulguration provides greater control of bleeding in highly vascular over-surface areas. 2. Presets The unit incorporates as many as ten user-defined presets for easy recall of frequency and settings. 3. Isolated RF output for Cut, Blend, and Coag modes This minimizes the potential of alternate site burns. 4. Ground Referenced RF output for Fulguration modes 5. Self-diagnostics These diagnostics continually monitor the unit to ensure proper performance. If the diagnostics is unsuccessful, the warning tones can be heard.
Technical parameters:
Environmental temperature range: 5°C~ 40°C
Relative moisture range: ≤80%
Atmosphere pressure range: 86.0 ~ 106.0 Kpa
 Working modes:
Pure cut: 1w ~ 60w (Load 500Ω)
Blend: 1w ~ 60w (Load 800Ω)
Coagulation: 1w ~ 60w (Load 1000Ω)
Fulguration: 0.1w ~ 35w (Load 1000Ω)
Bipolar: 1w ~ 30w (Load 200Ω)
Technology data:
Voltage: 220V±10V, 50Hz ±1Hz
Working frequency: 357 KHz ~ 575 KHz
Leakage currents to ground: Less than 0.5mA
Leakage currents to patient: Less than 0.01mA
Display Setting: Fulguration a.      0-10 range: 0.1watt increments b.      10-35range: 1.0 watt increments Cut, Blend, Coagulation, and Bipolar 1.0-watt increments Power supply:220V±10%,50±1%Hz. Transportation and storage a)        Ambient temperature range: -40°C~55°C; b)        Relative moisture range: ≤95%; c)        Atmosphere pressure range: 500hPa~1060hPa. Accessories Included: Electrosurgical Pencil, disposable                           2pcs Bipolar Forceps with cable, reusable                      1pc Disposable Electrosurgical Pad                               2pcs Cable for Electrosurgical Pad, reusable                  1pc Footswitch                                                              1pc Power cord                                                             1pc Manual                                                                    1pc
Features
  • High-quality tried-and-tested materials guarantee a long service life for OBS reusable electrosurgical pencils.
  • Material is durable for high temperature and high press disinfection for more than 30 times.
  • Cost compared to disposable instruments
  • The initial cost of the reusable electrosurgical pencil is easily recouped after only a fraction of the expected number of uses and compares favorably to the cost of disposable pencils.
Features:
  1. Material: Made from medical-grade silicone, which is durable and flexible.
  2. Reusable: Can be used multiple times after proper sterilization, making it cost-effective.
  3. Adhesive Backing: Comes with an adhesive side to securely attach to the patient's skin.
  4. Large Surface Area: Designed to disperse electrical current over a wide area to minimize the risk of burns.
  5. Connectors: Typically equipped with connectors like REM or banana connectors for easy attachment to electrosurgical units.
Uses:
  1. Electrosurgical Procedures: Used in various surgical procedures, including cutting, coagulating, and desiccating tissue.
  2. Patient Safety: Ensures safe operation of electrosurgical units by dispersing the electrical current away from the patient's body.
  3. Versatility: Suitable for different types of surgeries, from open surgeries to laparoscopic procedures.
Electrotherapy electrodes with cables are used to connect the electrodes to the electrotherapy device, allowing electrical currents to be delivered to the targeted area. These cables typically have a standard 2mm pin connector that plugs into the device and the electrodes. There are different types of cables available, such as:
  • Standard Lead Wires: These are the basic cables that come with most electrotherapy units.
  • Bifurcation Cables: These cables allow you to connect multiple electrodes to a single channel, effectively doubling the number of electrodes you can use.
  • Extended Length Cables: These are longer cables that provide more flexibility in positioning the electrodes.
Features

1. LED light positioned between the electrodes enhances the vision during surgery.

2. Massive area hemostasis can be performed in a short time in order to reduce intraoperative blood loss 3. Saline line and dripping device are equipped in an attempt to contain the heat on the treated tissue and avoid thermal tissue damage
Indications for Use
  • Ensure that both electrodes are in contact with the tissue to be treated. Activation and saline flow occur simultaneously.
  • Ensure that saline is flowing at the time of activation
  • These devices should never be used when:
  • There is visible evidence of damage to the exterior of the device such as cracked or damaged plastic or connector damage.
  • These devices fail the inspection described herein.
  • In the presence of flammable gases, flammable prep solutions or drapes. Oxidizing. Gases such as Nitrous Oxide (N2O), or in oxygen-riched environments.
  • Do not use monopolar electrosurgery on small appendages, as in circumcision or finger surgery.
WeightN/AN/AN/AN/AN/AN/A
DimensionsN/AN/AN/AN/AN/AN/A