The Center series uses city tap water as the water source, conveniently and quickly produces secondary RO reverse osmosis water, DI/EDI deionized water and UP ultrapure water. It adopts standard two-stage reverse osmosis system and EDI technology and modules*, and continuously produces Class II pure water with a TOC of more than 10MΩ.cm (25℃) and less than 30ppb*, and ultrapure water of 18.2MΩ.cm (25℃).There are currently four sub-product series of Center (Center-EDI) pure water and ultrapure water, and the system water output is: 45, 60, and 90 liters/hour.

Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
SF1033560130126-4
Brands:: Hi-Tech

Description

Performance characteristics
  • New 7.0-inch color touch screen

Animated menu, system information at a glance, and a new fingertip touch operation experience.

  • The lab optimized standard two-stage reverse osmosis system

The use of dual pumps, dual membranes and transition water tanks reduces system energy consumption, reduces wastewater and produces more stable water quality.

  • Advanced EDI technology and modules

Providing you with consistent 10MΩ.cm grade high purity water at an optimized operating cost.

  • Removable water tray

Prevent water droplets from splashing, store water in time, facilitate cleaning, and keep the system clean.

  • Built-in double water tank

Built-in 20L PE water tank and 1 20L pressure water bucket, saving more experimental space and eliminating the inconvenience of external water bucket.

Features and Advantages
  • The ultrapure water circulation system can be started and shut down freely to maintain the low bacterial contamination level of the system
  • Ultrapure water full pipeline disinfection program, can manually execute “circulation disinfection”, “water inlet disinfection”, “water tank filling”, “manual sewage discharge”, “stop disinfection”
  • Fully automatic RO membrane anti-scaling flushing (flushing interval and duration can be set) and manual forced flushing program to extend the service life of the RO membrane
  • The life of PP, KDF, AC, RO, UP, UF, TF, and UV consumables can be set, and the used time can be displayed, and automatic replacement reminders will be given when the time expires.
  • Water shortage and water full alarm, source water, RO reverse osmosis water, DI deionized water/UP ultrapure water exceeding the standard alarm
  • Compatible with two pure water storage methods: pressure water bucket and liquid level water tank, which can directly display the water storage capacity of the water tank to meet different application needs
  • System time setting (year/month/day/hour/minute), timed standby (0~60min), timed shutdown (0~24hour) functions
  • Record and check the replacement time of consumables at any time to fully grasp the equipment maintenance information
  • Complete information query and data management functions, fully control system operation status, water quality, consumables usage, timely alarm, historical alarm and other information
  • The entire pipeline adopts quick plug-in interface, and all pipes and joints are NSF certified
  • DOW RO reverse osmosis membrane ensures stable operation and high desalination rate
  • DOW’s high-purity nuclear-grade resin ensures that the water produced reaches 18.2MΩ.cm and reduces TOC precipitation
  • Ultra-long life 254 & 185nm dual wavelength UV lamp, effective sterilization, reducing TOC
  • MWCO 5000D UF ultrafiltration module, effectively removes endotoxins/pyrogens
  • 0.2μm PES polyethersulfone composite membrane terminal filter to ensure pure water quality

Reviews

There are no reviews yet.

Be the first to review “Full Touch Screen Water Purification System”

Your email address will not be published. Required fields are marked *

Quick Comparison

SettingsFull Touch Screen Water Purification System removeVENUS SOLO OEM SENSOR removeBistos BT-770-12.1" Touchscreen Patient Monitor removeCARBON MONOXIDE ATMOSPHERE MONITORING SYSTEM removeDISSUB ANALYSER removeFlowMir Disposable Turbine with Cardboard Mouthpiece remove
NameFull Touch Screen Water Purification System removeVENUS SOLO OEM SENSOR removeBistos BT-770-12.1" Touchscreen Patient Monitor removeCARBON MONOXIDE ATMOSPHERE MONITORING SYSTEM removeDISSUB ANALYSER removeFlowMir Disposable Turbine with Cardboard Mouthpiece remove
ImageBistos BT-770-12.1" Touchscreen Patient MonitorFlowMir Disposable Turbine with Cardboard Mouthpiece
SKUSF1033560130126-4SF1033560130141-15SF1033560059-1SF1033560130141-2SF1033560130141-17SF1033560084-22
Rating
Price

$0.00

$0.00

$902.00

$0.00

$0.00

$145.00

Stock
Availability
Add to cart

DescriptionShipped From Abroad The Center series uses city tap water as the water source, conveniently and quickly produces secondary RO reverse osmosis water, DI/EDI deionized water and UP ultrapure water. It adopts standard two-stage reverse osmosis system and EDI technology and modules*, and continuously produces Class II pure water with a TOC of more than 10MΩ.cm (25℃) and less than 30ppb*, and ultrapure water of 18.2MΩ.cm (25℃).There are currently four sub-product series of Center (Center-EDI) pure water and ultrapure water, and the system water output is: 45, 60, and 90 liters/hour.
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad
Key Features
  • Single gas (user defined)
  • Backward compatible with ADC’s ‘Eclipse’
  • Linearised Output
  • Continuous status signal to check device health
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped from Abroad The Bistos BT-770 patient monitor is equipped with a 12.1" touchscreen display, which allows for an easy operation and readability with a powerful rechargeable battery guaranteeing a continuous operation of 5 hours to monitor ECG, SpO2, NIBP, temperature and respiration Delivery & Availability: Typically 14 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.Shipped From Abroad

The COSAMS unit was designed specifically for use on submarines, most directly those that operate on diesel engines. Built to exacting military standards for performance, reliability and endurance, the Analox COSAMS uses proprietary Gas Filter Correlation (GFC) technology to specifically analyze the unique properties of CO.

The COSAMS (Carbon Monoxide Submarine Atmosphere Monitoring System) has been designed for use on submerged submarines to support life, where crew can be living and working for up to 90 days. Carbon monoxide can be generated on a submarine in several ways, from cooking and fire, to the incomplete combustion of diesel fuel and chlorate candles.
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad
Key Features
  • Proven hyperbaric sensing capability
  • You have the ability to change sensors and maintain the unit in the dockyard, reducing costs and downtime
  • Backlit display for low/no light situations
  • Portable and lightweight making it easy to use around the submarine
  • Externally accessible batteries making for more convenient and safer changing
  • MODBUS RTU over RS485 digital communications, allowing for easy incorporation into your existing platform management system, including JANUS enabled underwater communication networks
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock Spirometry testing requires maximum accuracy and hygiene. Each Flowmir disposable turbine, which includes a cardboard mouthpiece, has been individually factory calibrated with a computerized system and it is packaged individually. FlowMIR® is an inexpensive alternative to a costly reusable flowmeter and replaces the need for an antibacterial filter Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Content
Performance characteristics
  • New 7.0-inch color touch screen

Animated menu, system information at a glance, and a new fingertip touch operation experience.

  • The lab optimized standard two-stage reverse osmosis system

The use of dual pumps, dual membranes and transition water tanks reduces system energy consumption, reduces wastewater and produces more stable water quality.

  • Advanced EDI technology and modules

Providing you with consistent 10MΩ.cm grade high purity water at an optimized operating cost.

  • Removable water tray

Prevent water droplets from splashing, store water in time, facilitate cleaning, and keep the system clean.

  • Built-in double water tank
Built-in 20L PE water tank and 1 20L pressure water bucket, saving more experimental space and eliminating the inconvenience of external water bucket.
Features and Advantages
  • The ultrapure water circulation system can be started and shut down freely to maintain the low bacterial contamination level of the system
  • Ultrapure water full pipeline disinfection program, can manually execute "circulation disinfection", "water inlet disinfection", "water tank filling", "manual sewage discharge", "stop disinfection"
  • Fully automatic RO membrane anti-scaling flushing (flushing interval and duration can be set) and manual forced flushing program to extend the service life of the RO membrane
  • The life of PP, KDF, AC, RO, UP, UF, TF, and UV consumables can be set, and the used time can be displayed, and automatic replacement reminders will be given when the time expires.
  • Water shortage and water full alarm, source water, RO reverse osmosis water, DI deionized water/UP ultrapure water exceeding the standard alarm
  • Compatible with two pure water storage methods: pressure water bucket and liquid level water tank, which can directly display the water storage capacity of the water tank to meet different application needs
  • System time setting (year/month/day/hour/minute), timed standby (0~60min), timed shutdown (0~24hour) functions
  • Record and check the replacement time of consumables at any time to fully grasp the equipment maintenance information
  • Complete information query and data management functions, fully control system operation status, water quality, consumables usage, timely alarm, historical alarm and other information
  • The entire pipeline adopts quick plug-in interface, and all pipes and joints are NSF certified
  • DOW RO reverse osmosis membrane ensures stable operation and high desalination rate
  • DOW's high-purity nuclear-grade resin ensures that the water produced reaches 18.2MΩ.cm and reduces TOC precipitation
  • Ultra-long life 254 & 185nm dual wavelength UV lamp, effective sterilization, reducing TOC
  • MWCO 5000D UF ultrafiltration module, effectively removes endotoxins/pyrogens
  • 0.2μm PES polyethersulfone composite membrane terminal filter to ensure pure water quality
Description
The Venus Solo OEM sensor is a self-contained unit designed for integration into other manufacturers’ equipment and provides a measurement of gas concentration according to specific user requirements. These GFC (Gas Filter Correlation) sensors generate a signal proportional to the infrared absorption of the measured gas. Providing the gas concentration lies within the designed range of the sensor, the signal is periodically compared with a reference gas. Gas concentrations are indicated through the non-linearised analogue signal output. Gas connections to and from the sensor are via suitable fittings on the gas measuring cell. The Venus Solo OEM Series sensors electrical supply is designed to accept 24V DC (3amp max). Our Venus Solo OEM sensor uses GFC (Gas Filter Correlation) technology to give highly accurate gas measurements. The Venus Solo can be integrated into your own gas analyzer or management system and offers the user a 0-2.5v analogue output.

The sensor is currently available as either: Carbon dioxide (CO2), carbon monoxide (CO), nitrous oxide (N20), methane (CH4) or nitric oxide (NO). If your application requires a different gas, just let us know and we can customise it to your needs. The Venus Solo is used in Military applications to protect submariners from carbon monoxide (CO) exposure.  

Technical Specification
Venus Solo
Bistos BT-770 is a 12.1" touchscreen patient monitor designed for easy operations. SPECIFICATIONS
  • 12.1“ color TFT touch screen
  • ECG, Resp., SpO2, NIBP, Temp., CO2, IBP, Multi-gas, C.O., Masimo SpO2
  • Precise ECG measurement with pacemaker detection ST segment and 16 types of arrhythmia analysis Double overpressure protection for NIBP Intelligent cuff inflation pressure adjustment
  • Smart Hook/Stand design, provide multiple placement modes Plug & Play Modular IBP& C.O., Modular Printer Multiple configuration options: 4-channel IBP, CO2, invasive C.O., Multi-gas Over 5 hours continuous working on battery 12-15V wide range DC input, suitable for ambulance Capable to connect with central monitoring system HL7 export to clinical information systems (option)
 
Click Here To Download Catalogue
Key Features
  • Uses a GFC infra-red sensing technique ensuring the system is not sensitive to hydrogen or water vapor
  • Built-in auto-zero function ensures sensor stability
  • Real-time monitoring ensures rapid response to carbon monoxide (CO) issues as they occur
  • 90 days data-logging allows records to be stored and used should they ever be needed
  • Easy to maintain allowing you to be more self-sufficient whilst minimizing downtime
  • Designed specifically for the submarine environment so it is able to cope with the demands of the environment in terms of EMC, shock and temperature
 
Technical Specifications

Click here to download Data Sheet
Click here to download Manual
Description

The Sub Mk3P Continuous Gas Monitor from Analox is designed specifically to monitor life support gasses aboard a submarine in the event of a distressed submarine (DISSUB) situation.

Portable and lightweight, the Sub Mk3P monitor provides crucial information to the senior survivor about the state of the atmosphere inside the submarine during a time of crisis. This information helps that officer make one of the most challenging decisions any submariner ever has to make – attempt to escape the submarine or wait for rescue teams.
Technical Specification

Temperature & Humidity Sensor

Main Unit
Battery power 4 x ‘D’ alkaline cells (Hyperbaric)
External power 24V dc (9-36V dc), <0.5A
Backup batteries 2 x LR43 alkaline manganese cells
Displays 6 x 4 character LCD, with symbols and LED backlights
Operating temperature -5 to 50°C
Storage temperature -5 to 50°C
Operating pressure 0.7 to 10barA
Operating humidity 0 to 100%RH (Non-condensing)
Standards/ compliance NATO STANAG 1476:2014 ANEP/MNEP 85 & 86 (2014) DEF STAN 59-411:2014 (EMC) IACs E10:2014 (MarED) type tested IP65 CE marked (RoHS)"
Dimensions (W, H, D) 240mm x 198mm x 127mm
Weight 2kg with batteries installed
O2 Sensor
Range 0 to 2000mbar pO2
Accuracy ±10mbar (0 to 300mbar pO2) ±50mbar (300 to 2000mbar pO2)
Response time (t90) 20s
Detection mode Electro-chemical
Shelf life (in sealed packaging) 6 months
Expected life (in air) 12 months
CO2 Sensor
Range 0 to 100mbar pCO2
Accuracy ±10mbar
Response time (t90) 60s
Detection mode Infrared
Expected life (in air) 5 years
Pressure Sensor
Range 0.7 to 10barA (-3 to 90MSW or -10 to 300FSW)
Accuracy (including annual drift) -0.07bar +0.04bar
Response time (t90) <1s
Detection mode Piezoresistive
Expected life (in air) >12 months (Replaced as a part of the O2sensor)
Click here to download Data Sheet
Click here to download Technical Manual
    • Comfortable Packaging
    • Singularly Tested and Packed
    • Always 100% accurate and hygienic
    • No Calibration required
    • No Sterilization required
    • No Antibacterial Filter required
    • No Cross Contamination
    • Not affected by Vapour Condensation
    • Not affected by Ambient conditions
    •  A full Spirometry session can be performed, including a Bronchial Challenge and POST Bronchodilator test. For each patient after the Spirometry test, both turbine and spirometer mouthpiece are thrown away
    • .
   
WeightN/AN/AN/AN/AN/AN/A
DimensionsN/AN/AN/AN/AN/AN/A
Additional information
Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • Rating
  • Price
  • Description
Click outside to hide the comparison bar
Compare