Full Touch Screen Water Purification System

$0.00

Shipped From Abroad

The Center series uses city tap water as the water source, conveniently and quickly produces secondary RO reverse osmosis water, DI/EDI deionized water and UP ultrapure water. It adopts standard two-stage reverse osmosis system and EDI technology and modules*, and continuously produces Class II pure water with a TOC of more than 10MΩ.cm (25℃) and less than 30ppb*, and ultrapure water of 18.2MΩ.cm (25℃).There are currently four sub-product series of Center (Center-EDI) pure water and ultrapure water, and the system water output is: 45, 60, and 90 liters/hour.

Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
SF1033560130126-4
Brands:: Hi-Tech

Description

Performance characteristics
  • New 7.0-inch color touch screen

Animated menu, system information at a glance, and a new fingertip touch operation experience.

  • The lab optimized standard two-stage reverse osmosis system

The use of dual pumps, dual membranes and transition water tanks reduces system energy consumption, reduces wastewater and produces more stable water quality.

  • Advanced EDI technology and modules

Providing you with consistent 10MΩ.cm grade high purity water at an optimized operating cost.

  • Removable water tray

Prevent water droplets from splashing, store water in time, facilitate cleaning, and keep the system clean.

  • Built-in double water tank

Built-in 20L PE water tank and 1 20L pressure water bucket, saving more experimental space and eliminating the inconvenience of external water bucket.

Features and Advantages
  • The ultrapure water circulation system can be started and shut down freely to maintain the low bacterial contamination level of the system
  • Ultrapure water full pipeline disinfection program, can manually execute “circulation disinfection”, “water inlet disinfection”, “water tank filling”, “manual sewage discharge”, “stop disinfection”
  • Fully automatic RO membrane anti-scaling flushing (flushing interval and duration can be set) and manual forced flushing program to extend the service life of the RO membrane
  • The life of PP, KDF, AC, RO, UP, UF, TF, and UV consumables can be set, and the used time can be displayed, and automatic replacement reminders will be given when the time expires.
  • Water shortage and water full alarm, source water, RO reverse osmosis water, DI deionized water/UP ultrapure water exceeding the standard alarm
  • Compatible with two pure water storage methods: pressure water bucket and liquid level water tank, which can directly display the water storage capacity of the water tank to meet different application needs
  • System time setting (year/month/day/hour/minute), timed standby (0~60min), timed shutdown (0~24hour) functions
  • Record and check the replacement time of consumables at any time to fully grasp the equipment maintenance information
  • Complete information query and data management functions, fully control system operation status, water quality, consumables usage, timely alarm, historical alarm and other information
  • The entire pipeline adopts quick plug-in interface, and all pipes and joints are NSF certified
  • DOW RO reverse osmosis membrane ensures stable operation and high desalination rate
  • DOW’s high-purity nuclear-grade resin ensures that the water produced reaches 18.2MΩ.cm and reduces TOC precipitation
  • Ultra-long life 254 & 185nm dual wavelength UV lamp, effective sterilization, reducing TOC
  • MWCO 5000D UF ultrafiltration module, effectively removes endotoxins/pyrogens
  • 0.2μm PES polyethersulfone composite membrane terminal filter to ensure pure water quality

Reviews

There are no reviews yet.

Be the first to review “Full Touch Screen Water Purification System”

Your email address will not be published. Required fields are marked *

Quick Comparison

SettingsFull Touch Screen Water Purification System removeVENUS SOLO OEM SENSOR removePERSONAL CO2/O2 MONITOR-ASPIDA removeDISSUB ANALYSER removeAtmosphere Protection Module removeAx60+ Kiosk remove
NameFull Touch Screen Water Purification System removeVENUS SOLO OEM SENSOR removePERSONAL CO2/O2 MONITOR-ASPIDA removeDISSUB ANALYSER removeAtmosphere Protection Module removeAx60+ Kiosk remove
Image
SKUSF1033560130126-4SF1033560130141-15SF1033560130141-11SF1033560130141-17SF1033560130141-16SF1033560130141-6
Rating
Price

$0.00

$0.00

$0.00

$0.00

$0.00

$0.00

Stock
Availability
Add to cart

DescriptionShipped From Abroad The Center series uses city tap water as the water source, conveniently and quickly produces secondary RO reverse osmosis water, DI/EDI deionized water and UP ultrapure water. It adopts standard two-stage reverse osmosis system and EDI technology and modules*, and continuously produces Class II pure water with a TOC of more than 10MΩ.cm (25℃) and less than 30ppb*, and ultrapure water of 18.2MΩ.cm (25℃).There are currently four sub-product series of Center (Center-EDI) pure water and ultrapure water, and the system water output is: 45, 60, and 90 liters/hour.
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad
Key Features
  • Single gas (user defined)
  • Backward compatible with ADC’s ‘Eclipse’
  • Linearised Output
  • Continuous status signal to check device health
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad
Key Features
  • IP65 rated, ensuring the unit is dust tight and protected against water
  • Data logging capability
  • Man down alarm
  • Time Weighted Average (TWA) monitoring
  • Rechargeable batteries
  • Intelligent software – up to 2 users registered to one unit
  • User changeable alarms
  • We recommend: 23.5% for oxygen (O2) enrichment (As per NHS SOPS/EH40/OSHA); 19.5% for oxygen (O2) deficiency 0.5%; & 1.5% for carbon dioxide (CO2) enrichment
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad
Key Features
  • Proven hyperbaric sensing capability
  • You have the ability to change sensors and maintain the unit in the dockyard, reducing costs and downtime
  • Backlit display for low/no light situations
  • Portable and lightweight making it easy to use around the submarine
  • Externally accessible batteries making for more convenient and safer changing
  • MODBUS RTU over RS485 digital communications, allowing for easy incorporation into your existing platform management system, including JANUS enabled underwater communication networks
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad
Key Features
  • Flexible to meet your specific needs and ensures you meet current legislation
  • Measures up to 2 gasses with a choice of; O2 (oxygen), CO2 (carbon dioxide) and R134a (refrigerants). The APM will soon be able to measure VOCs (volatile organic compounds)
  • Uses MODBUS RTU communications protocol
  • Temperature compensated sensors with PressureSync technology
  • Fitted with 2 relays
  • Compatible with the Analox Distributed Atmosphere Monitoring solution (DAMS)
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad
Key Features
  • Low maintenance
  • Quick Connect System
  • Pre-wired, ready to go
  • Can support up to 4 alarm units
  • Push button for unit testing
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Content
Performance characteristics
  • New 7.0-inch color touch screen

Animated menu, system information at a glance, and a new fingertip touch operation experience.

  • The lab optimized standard two-stage reverse osmosis system

The use of dual pumps, dual membranes and transition water tanks reduces system energy consumption, reduces wastewater and produces more stable water quality.

  • Advanced EDI technology and modules

Providing you with consistent 10MΩ.cm grade high purity water at an optimized operating cost.

  • Removable water tray

Prevent water droplets from splashing, store water in time, facilitate cleaning, and keep the system clean.

  • Built-in double water tank
Built-in 20L PE water tank and 1 20L pressure water bucket, saving more experimental space and eliminating the inconvenience of external water bucket.
Features and Advantages
  • The ultrapure water circulation system can be started and shut down freely to maintain the low bacterial contamination level of the system
  • Ultrapure water full pipeline disinfection program, can manually execute "circulation disinfection", "water inlet disinfection", "water tank filling", "manual sewage discharge", "stop disinfection"
  • Fully automatic RO membrane anti-scaling flushing (flushing interval and duration can be set) and manual forced flushing program to extend the service life of the RO membrane
  • The life of PP, KDF, AC, RO, UP, UF, TF, and UV consumables can be set, and the used time can be displayed, and automatic replacement reminders will be given when the time expires.
  • Water shortage and water full alarm, source water, RO reverse osmosis water, DI deionized water/UP ultrapure water exceeding the standard alarm
  • Compatible with two pure water storage methods: pressure water bucket and liquid level water tank, which can directly display the water storage capacity of the water tank to meet different application needs
  • System time setting (year/month/day/hour/minute), timed standby (0~60min), timed shutdown (0~24hour) functions
  • Record and check the replacement time of consumables at any time to fully grasp the equipment maintenance information
  • Complete information query and data management functions, fully control system operation status, water quality, consumables usage, timely alarm, historical alarm and other information
  • The entire pipeline adopts quick plug-in interface, and all pipes and joints are NSF certified
  • DOW RO reverse osmosis membrane ensures stable operation and high desalination rate
  • DOW's high-purity nuclear-grade resin ensures that the water produced reaches 18.2MΩ.cm and reduces TOC precipitation
  • Ultra-long life 254 & 185nm dual wavelength UV lamp, effective sterilization, reducing TOC
  • MWCO 5000D UF ultrafiltration module, effectively removes endotoxins/pyrogens
  • 0.2μm PES polyethersulfone composite membrane terminal filter to ensure pure water quality
Description
The Venus Solo OEM sensor is a self-contained unit designed for integration into other manufacturers’ equipment and provides a measurement of gas concentration according to specific user requirements. These GFC (Gas Filter Correlation) sensors generate a signal proportional to the infrared absorption of the measured gas. Providing the gas concentration lies within the designed range of the sensor, the signal is periodically compared with a reference gas. Gas concentrations are indicated through the non-linearised analogue signal output. Gas connections to and from the sensor are via suitable fittings on the gas measuring cell. The Venus Solo OEM Series sensors electrical supply is designed to accept 24V DC (3amp max). Our Venus Solo OEM sensor uses GFC (Gas Filter Correlation) technology to give highly accurate gas measurements. The Venus Solo can be integrated into your own gas analyzer or management system and offers the user a 0-2.5v analogue output.

The sensor is currently available as either: Carbon dioxide (CO2), carbon monoxide (CO), nitrous oxide (N20), methane (CH4) or nitric oxide (NO). If your application requires a different gas, just let us know and we can customise it to your needs. The Venus Solo is used in Military applications to protect submariners from carbon monoxide (CO) exposure.  

Technical Specification
Venus Solo

The Aspida is a robust, high specification personal oxygen (O2), carbon dioxide (CO2) or dual (O2 / CO2 combined) monitor which can be worn on a belt or even wall mounted as a backup to a primary safety system.

The Aspida, (Greek for Shield) helps you comply with the regulations, will remind you when maintenance is needed and it safeguards the user from the gas risks.  
Technical Specification
Aspida
Operating temperature -5°C to +50°C
Humidity Range 0 to 99% RH
Display High-visibility, Organic Light Emitting Diode (OLED) display
Alarm horn 95dB @ 30cm (110dB - man-down alarm)
LED indicators 1 x Green - OK, 1 x Amber - Fault, 1 x Red - Alarm
Internal data log 1 log every 30 seconds for at least 7 days of continuous use
Batteries 2 x NiMH 2100mAh AA batteries (or suitable AA type batteries)
Battery discharge time 15 hours under normal operation (passive atmospheric monitoring, minimal user interaction, no alarms)
Battery lifespan 2 years
Battery charge time 4.5 hours (from flat)
Charge power supply rating 9 V DC - 0.55A
Dimensions 127 x 44 x 90 mm / 5 x 1.7 x 3.5 inches (HxDxW)
Electronics warranty 2 years
IP rating IP65
Aspida Sensors
CO2 Sensor O2 Sensor
Sensor type Analox infrared MIR Electrochemical
Range 0.01 to 5% 0.1 to 25%
Accuracy (at standard temperature and pressure) ±2% of full scale between 0.01% and 2.5%, ±3% ±3% of full scale between 0.1% and 25%
Response time T90 <60 seconds T90 <30 seconds
Sensor life span 5 years 2 year (expected)
Characteristics

Personal Protection

Enriched oxygen (O2) can cause a condition on the human body called hyperoxia, enriched CO2 is highly toxic, both are a threat to life and must be safeguarded against. If an inert gas such as nitrogen (N2), argon (Ar), helium (He) or liquid nitrogen (LN2) leaks then this will deplete the levels of oxygen (O2) in the surrounding area, creating a dangerous atmosphere. The Aspida can offer personal protection and alerts to all of these risks, offering you true peace of mind.  

Ideal Solution

Offering audible and visual alarms, data logging and a man down alarm for lone workers, it is an ideal solution to protect staff from the dangers of a leak of carbon dioxide (CO2), oxygen (O2) or inert gas. The Aspida is an affordable, easy to operate gas detection monitor and is perfect for ensuring safety in areas where the gas is piped, used or stored. It operates using rechargeable battery technology allowing it to run for more than 12 hours continuously between charges.
 
Click here to download User Manual
Click here to download Data Sheet
Download Aspida Software
Description

The Sub Mk3P Continuous Gas Monitor from Analox is designed specifically to monitor life support gasses aboard a submarine in the event of a distressed submarine (DISSUB) situation.

Portable and lightweight, the Sub Mk3P monitor provides crucial information to the senior survivor about the state of the atmosphere inside the submarine during a time of crisis. This information helps that officer make one of the most challenging decisions any submariner ever has to make – attempt to escape the submarine or wait for rescue teams.
Technical Specification

Temperature & Humidity Sensor

Main Unit
Battery power 4 x ‘D’ alkaline cells (Hyperbaric)
External power 24V dc (9-36V dc), <0.5A
Backup batteries 2 x LR43 alkaline manganese cells
Displays 6 x 4 character LCD, with symbols and LED backlights
Operating temperature -5 to 50°C
Storage temperature -5 to 50°C
Operating pressure 0.7 to 10barA
Operating humidity 0 to 100%RH (Non-condensing)
Standards/ compliance NATO STANAG 1476:2014 ANEP/MNEP 85 & 86 (2014) DEF STAN 59-411:2014 (EMC) IACs E10:2014 (MarED) type tested IP65 CE marked (RoHS)"
Dimensions (W, H, D) 240mm x 198mm x 127mm
Weight 2kg with batteries installed
O2 Sensor
Range 0 to 2000mbar pO2
Accuracy ±10mbar (0 to 300mbar pO2) ±50mbar (300 to 2000mbar pO2)
Response time (t90) 20s
Detection mode Electro-chemical
Shelf life (in sealed packaging) 6 months
Expected life (in air) 12 months
CO2 Sensor
Range 0 to 100mbar pCO2
Accuracy ±10mbar
Response time (t90) 60s
Detection mode Infrared
Expected life (in air) 5 years
Pressure Sensor
Range 0.7 to 10barA (-3 to 90MSW or -10 to 300FSW)
Accuracy (including annual drift) -0.07bar +0.04bar
Response time (t90) <1s
Detection mode Piezoresistive
Expected life (in air) >12 months (Replaced as a part of the O2sensor)
Click here to download Data Sheet
Click here to download Technical Manual
Descriptions
The Analox APM (Atmosphere Protection Module) is a configurable modular system which has the ability to monitor up to 2 gasses. This unique solution can be used as a stand alone atmosphere monitor or it can be integrated into existing PMS systems.  
Technical Specifications
System Specifications
Operating Temperature 0°C to +45°C +32°F to +113°F
Operating pressure 700 to 1300mBar
Humidity Range 0 to 95% RH
Power 24vDC (nominal) as standard
Communications MODBUS RTU
Relays 2 as standard
Calibration interval Before mission and / or every 3 months
Sensor Unit
Sensor type Range Danger
CO2 NDIR 0 to 5% / 0 to 30mBar Toxic
O2 (Depleted) Electrochemical 0 to 25% / 0 to 2500mBar Asphyxiation
O2 (enriched) Electrochemical 0 to 25% / 0 to 2500mBar Fire/explosion
R134a NDIR 0 to 1000ppm Asphyxiation
VOCs PID 0 to 20ppm Toxic
Click here to download Data Sheet
Download Pumped Detectors Technical Manual
CO2 MONITOR & ALARM DESIGNED FOR KIOSKS

The Ax60+ Kiosk is a CO2 monitor and alarm specifically designed by Analox to alert personnel to a build up/leak of CO2 using a state-of-the-art infrared sensor. The alarm provides both audio and visual alerts in the case of increased levels of carbon dioxide (CO2). Up to four alarms can be added as needed and the unit does not need periodic calibration.

CO2 monitoring with the AX60+ Kiosk
The Ax60+ Kiosk is a smaller version of the popular Ax60+ carbon dioxide (CO2) monitor. It is simple to wall mount in the area where carbon dioxide (CO2) is stored or piped. The Ax60+ Kiosk sensor needs to be installed at a height of 12-18 inches (305-457mm) above the floor – this is because the carbon dioxide (CO2) that leaks from a gas cylinder is denser than ambient air and can collect at low levels. The alarm should be located above the sensor at about head height or at the entrance to the kiosk.  
Technical Specification
Sensor Unit
WeightN/AN/AN/AN/AN/AN/A
DimensionsN/AN/AN/AN/AN/AN/A
Additional information
Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • Rating
  • Price
  • Description
Click outside to hide the comparison bar
Compare