Features of Handheld Anesthesia Gas Monitor MG1000
  • 5 Inch TFT Display with 480*272 resolution,
  • Built-in stand multi-angle observation.
  • Automatic temperature and pressure compensation.
  • Self-developed Data Analysis Software for Multi Gas Monitoring
  • Rechargeable high-capacity built-in Li Battery, continuously working for over 8 hours.
  • Suitable for adults, pediatrics, and neonates in a range of clinical environments including the OR, ICU, Ambulance, and Transportation.

 

Specifications of Handheld Anesthesia Gas Monitor MG1000
Measuring Range ETCO2 N2O ISO, ENF, HAL DES SEV Respiratory Rate
0 – 10% / 10-15% 0 – 100% 0 – 6% 0 – 18% 0 – 6% 3 – 150 BPM
Measuring Accuracy ±0.2vol %+2% of reading / 0.3vol %+2% of reading 2vol %+2% of reading 0.2vol %+2% of reading 0.2vol %+2% of reading 0.2vol %+2% of reading ±1 breath
Adapter Input AC 220V
Adapter Output DC 12V, 2A
Battery Chargeable Lithium Battery, lasts for 10 hours, Charge time: 4 Hours
Temp & Humidity Operating: 0º to 40°, 10 to 90% RH, non-condensing
Storage: -40º to 70ºC, <90% RH, non-condensing
Optional anesthesia sensor module MG-1000: Sidestream anesthesia sensor AG100
MG-1000B: Mainstream anesthesia sensor AG200

Reviews

There are no reviews yet.

Be the first to review “Handheld Anesthesia Gas Monitor MG1000”

Your email address will not be published. Required fields are marked *

Quick Comparison

SettingsHandheld Anesthesia Gas Monitor MG1000 removeTimesco Jumper Fingertip Pulse Oximeter removeAgary I.V. Cannula removeElastomeric Pump (Disposable Infusion Pump) with PCA removeRender SD-M2000C+ Anesthetic Machine removeHersill Genesis Anaesthetic Machine remove
NameHandheld Anesthesia Gas Monitor MG1000 removeTimesco Jumper Fingertip Pulse Oximeter removeAgary I.V. Cannula removeElastomeric Pump (Disposable Infusion Pump) with PCA removeRender SD-M2000C+ Anesthetic Machine removeHersill Genesis Anaesthetic Machine remove
ImageFingertip Pulse OximeterHersill Genesis Anaesthetic Machine
SKUSF1033560084-2SF1033560084-221SF1033560084-18SF1033560011-11SF1033560450-1
Rating
Price

$0.00

$17.00

$7.10

$0.00

$4,070.00

$0.00

Stock
Availability
Add to cart

DescriptionShipped From Abroad

Handheld monitor with 5-inch display, monitoring ETCO2 and anesthesia gas (N2O, ENF, HAL, SEV, DES, ISO) concentration, high accuracy, with a built-in rechargeable battery, suitable for clinical and emergency circumstances.

Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In Stock Integrated with SPO2 probe and processing display module. Small in volume、light in weight and convenient in carrying. Operation of the product is simple ,low power consumption. SPO2 , PR and Ridisplay,. Pulse rate value display, bar graph display. Low-voltage indication: low-voltage indicator appears before working abnormally which is due to low-voltage. Automatically power off function: when the device is under the state of measuring interface . it will automatically power off within 5 seconds if the finger falls out of probe. Delivery & Availability: Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.In stock I.V Cannula with wings & injection port 24G/19mm, 0.70mm/20ml/min Injection port with unidirectional valve for facilitating extra medication and preventing back flow. Specially engineered recessed plug with protective ring to avoid risk of contamination. Angle & grooved wings for easy cannulation and to prevent rolling of cannula over patient body. Colour coded cap for easy identification of guage size.
Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In Stock This product make the tension of silicon capsule as the driving force to control the flow by micro porous tube, it was pre-selected by doctor base on patients'situation, and then and then handed over to the patients ' self- management “to relieve or ease the pain

Delivery & Availability:

Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped from Abroad
  • 5.5" monochrome TFT LCD screen
  • Built in Anesthesia ventilator
  • Updated 2 high precise vaporizers ZF-3000 (Volume > 250ml)
  • Updated high brightness LED lamp
  • Compact CO2 absorber (autoclavable)
  • Optional: Continuous FIO2 monitoring
  • Optional: Anaesthesia gas scavenging system
  • Optional: Yoke system for 5L O2/N2O cylinders
  • Optional: Integrated suction unit on air
Delivery & Availability: Typically 21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped from Abroad The Genesis anaesthesia workstations meet your most ambitious requirements. They stand out for their lung protective ventilation. Application Field: Neonates, Pediatrics & Adults Ventilation Modes: Volume controlled (VC), Pressure controlled (PC), Adaptive Pressure with Volume Guaranteed (APVG) & Pressure Support Ventilation (PSV) Delivery & Availability: Typically 21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Content
Features of Handheld Anesthesia Gas Monitor MG1000
  • 5 Inch TFT Display with 480*272 resolution,
  • Built-in stand multi-angle observation.
  • Automatic temperature and pressure compensation.
  • Self-developed Data Analysis Software for Multi Gas Monitoring
  • Rechargeable high-capacity built-in Li Battery, continuously working for over 8 hours.
  • Suitable for adults, pediatrics, and neonates in a range of clinical environments including the OR, ICU, Ambulance, and Transportation.
 
Specifications of Handheld Anesthesia Gas Monitor MG1000
Measuring Range ETCO2 N2O ISO, ENF, HAL DES SEV Respiratory Rate
0 – 10% / 10-15% 0 – 100% 0 – 6% 0 – 18% 0 – 6% 3 – 150 BPM
Measuring Accuracy ±0.2vol %+2% of reading / 0.3vol %+2% of reading 2vol %+2% of reading 0.2vol %+2% of reading 0.2vol %+2% of reading 0.2vol %+2% of reading ±1 breath
Adapter Input AC 220V
Adapter Output DC 12V, 2A
Battery Chargeable Lithium Battery, lasts for 10 hours, Charge time: 4 Hours
Temp & Humidity Operating: 0º to 40°, 10 to 90% RH, non-condensing
Storage: -40º to 70ºC, <90% RH, non-condensing
Optional anesthesia sensor module MG-1000: Sidestream anesthesia sensor AG100
MG-1000B: Mainstream anesthesia sensor AG200
Integrated with SPO2 probe and processing display module • Small in volume, light in weight, convenient in carrying • Simple operation, lower power consumption • OLED screen display • SPO2, PR, bar graph of pulse, plethysmogram, blood perfusion index, battery indication display • 4 directions display, 6 display models, large fonts display • Brightness control, Demo mode, Setup menu • Movement interference • Alarm function and adjustable alarm parameters • Can be connected to mobile phones through Bluetooth; can support Android and iOS client • Auto power-off when no signal after 10s • Powered by 2*AAA alkaline batteries Specification: • Size: 62 x 37 x 32mm • Peak wavelength range of the light emitted from the probe: red light 660nm±3; infrared light 905nm±5 • Maximum optical output power of the probe: 1.2mW for infrared light (905nm) • Bluetooth module: 4.0 (single-mode) • Working temperature: 5℃ to 40℃ (41°F to 104°F) • Relative humidity: 15% to 80%, non-condensing • Atmospheric pressure: 70kPa to 106kPa • Rated voltage: DC 3V Package included: • 1 x JUMPER JPD-500F Bluetooth Fingertip Pulse Oximeter • 2 x AAA Batteries • 1 x Carry Case • 1 x Lanyard • 1 x English User ManualI.V Cannula with wings & injection port 24G/19mm, 0.70mm/20ml/min Injection port with unidirectional valve for facilitating extra medication and preventing back flow. Specially engineered recessed plug with protective ring to avoid risk of contamination. Angle & grooved wings for easy cannulation and to prevent rolling of cannula over patient body. Colour coded cap for easy identification of guage size.This product make the tension of silicon capsule as the driving force to control the flow by micro porous tube, it was pre-selected by doctor base on patients'situation, and then and then handed over to the patients ' self- management “to relieve or ease the pain Product Components: one-way valve medicated device, elastic liquid storage device, liquid medicine filter, current limiting device, automatic liquid feeding device ( CBI & PCA ), pipe and the external connector; Product Features: 1. The continued to liquid (CBI) make the drug-stored sac mechanical stretch as a driving force, limited the flow through the micro porous tube to the patient safely, effectively, slightly, continuous uniform injection of liquid to analgesic effect; extrusion pump body does not affect the liquid normal velocity; liquid filtering device which can control the particles enter the body better; 2. Continued to liquid + self control to liquid ( CBI+PCA ) make the drug-stored sac mechanical stretch as a driving force, limited the flow through the micro porous tube to the patient safely, effectively, slightly, continuous uniform injection of liquid to analgesic effect; Automatic medicated function is the patients can medicate according to pain independently. Extrusion pump body does not affect the liquid normal velocity; liquid filtering device which can control the particles enter the body better; How to use: 1. Get analgesia pump out from sterile packaging, removing the cap of medicine inlet and outlet; pour the analgesic liquid in the liquid storage device, draw out the air from the liquid storage. 2. Finish medicating, waiting for the liquid outflow from the medicine outlet; please clamp tightly to stop flowing for preparation. 3. Control keys (PCA key) is a function key to add the medicine base on continue to medicated by patients' self-controlled. So the patients can self-control the PCA key under the guidance of doctors, according to the needs while they are in treatment. At the same time, doctor should fill in PCA treatment card, so that they can analyze the condition from PCA additional times.
  • 5.5" monochrome TFT LCD screen
  • Built in Anesthesia ventilator
  • Updated 2 high precise vaporizers ZF-3000 (Volume > 250ml)
  • Updated high brightness LED lamp
  • Compact CO2 absorber (autoclavable)
  • Optional: Continuous FIO2 monitoring
  • Optional: Anaesthesia gas scavenging system
  • Optional: Yoke system for 5L O2/N2O cylinders
  • Optional: Integrated suction unit on air
 
Click Here To Download Catalogue
   
 
The Genesis anaesthesia workstations meet your most ambitious requirements. They stand out for their lung protective ventilation, accuracy and performance, cost saving, design and ergonomics, safety and versatility.   TECHNICAL SPECIFICATION OPERATING DATA
  • Weight - 105 kg
  • Dimensions - 92 cm Wide x 68 cm Deep x 139 cm High (93 cm to the table surface)
  • Packaging Dimensions - 105 cm Wide x 75 cm Deep x 160 cm High
  • Operating voltage supply - 110 to 240 V~, 47 to 63 Hz (12 to 6 A)
  • Power input - 120 W typically (max. 1.2 kW with auxiliary outlets used)
  • Battery autonomy - 90 min typically
  • Auxiliary power outlets - 4, with automatic protection
  • O2, N2O and Air supply - 2.7 to 6.9 bar (39.1 to 100 psi)
  • Screen - TFT 18.5" (47 cm) projected capacitive touchscreen
  • Protection class - Class I, gas analyser type BF defibrillation proof
  • Classification - Class II b
  • Storage - One front drawer with self-brake system and two back cabinets with door
  • Lighting - LED bar below the screen controlled from the touchscreen
  • Auxiliary integrated systems - Auxiliary 02 flow meter (0-15 L/min), Auxiliary 02 suppy valve (NF standard) and Suction device
  • Communication ports - 1 x RS-232, 2 x USB, 1 x LAN Ethernet
Fresh Gases (02, N20 and Air, electronically controlled)
  • Fresh gas flow - 0 and 0.1 to 18 L/min 02/N20/Air
  • Accuracy - 0.1 to 0.5 L/min = ±0.05 L/min; 0.5 to 18 L/min = ±10 %
  • 02 concentration - 21 to 100% vol. with Air, 25 to 100% with N20 (minimum 200 ml/min 02)
  • 02 Safety fresh gas (backup) - 0-0.2-0.4-0.7-1-1.5- 2- 3- 4- 6- 8-10-12-15 L/min 02
  • 02 flush (+02) - 40 L/min standard (adjustable 25 - 75 L/min upon requirement)
Breathing System (CABS)
  • Autoclavable - 134 °C
  • Weight of breathing system - 9.8 kg
  • C02 absorber volume - 1.5 L
  • Leakage - < 150 mL/min (at 30 hPa)
  • Pressure limiting valve APL - 0 to 70 hPa
  • Pressure relief valve - 125 hPa
  • Vacuum safety valve - 0.3 hPa
  • resistance at 60L/min - 5.80 hPa
  • resistance at 60L/min - 2.90 hPa
  • resistance at 30L/min - 3.55 hPa
  • resistance at 30L/min - 0.89 hPa
  • Internal Compliance at 30 hPa - 15 mL
  VENTILATOR Operation / Ventilation Modes Volume controlled (VC) modes:
  • Volume Controlled Ventilation (VCV)
  • VC Synchronized Intermittent Mandatory Ventilation (VC-SIMV)
  • VC-SIMV with Pressure Support (VC-SIMV-PS) *
Pressure controlled (PC) modes:
  • Pressure Controlled Ventilation (PCV)
  • PC Synchronized Intermittent Mandatory (PC-SIMV)
  • PC-SIMV with Pressure Support (PC-SIMV-PS) *
Adaptive Pressure with Volume Guaranteed (APVG) modes (other trade names: Autoflow,PCVR, PRVC, AVAPS, VC+)
  • Adaptive Pressure with Volume Guaranteed (APVG) *
  • APVG Synchronized Intermittent Mandatory (APVG-SIMV) *
  • APVG -SIMV with Pressure Support (APVG-SIMV-PS) *
Pressure Support Ventilation (PSV) *
  • (other trade names: PS, ASB, SPS, IPS)
  Non-mechanical Operation / Ventilation Modes
  • Manual ventilation through the CABS system (Auto/Manual software controlled)
  • Spontaneous ventilation either through the bellows (auto mode) or through the bag
  • (manual mode) Manual ventilation through the external fresh gas outlet for non-rebreathing systems (Bain, Mapleson, ...)
Application field: Neonates, Pediatrics & Adults
  • Tidal volume - 5 to 1500 mL
  • Inspiratory pressure - 0 to 68 hPa
  • Ventilation frequency ­- 3 to 120/min
  • Inspiratory time - 0.05 to 16.6s
  • l:E ratio - 5:1 to 1:8
  • Inspiratory pause - 0 to 60%
  • Inspiratory flow - max. 150 L/min
  • PEEP - 0 to 30 hPa
  • Flow trigger - 0.2 to 15 L/min
  • Pressure support - 5 to 50 hPa
  • Ramp time - 0.1 to 2 s
  • Maximum pressure - 0 to 68 hPa
  MONITORING
  • 5" (47 cm) projected capacitive touchscreen, supported on a 360° rotating and 2 axis tilting arm.
  • Measurements displayed: Peak pressure; Plateau pressure; Mean pressure; Expiratory minute ventilation; Expiratory tidal volume; Inspiratory tidal volume; Expiratory volumeter; Breathing rate; Compliance and Resistance (in VC modes); Patient info (age, weight, MAC, Class ASA); Connected sensors; Battery status; Power supply status; Gases supply pressures for 02, N20 and Air; Inspiratory and expiratory concentration of 02, N20, C02 and Anaesthetic gas*
  • Parametres charted as curves (up to 3 simultaneously): Airway pressure; Expiratory flow; Inspiratory flow; Volume; Fresh gases (Rotstyle); Concentration of 02, N20, C02 and Anaesthetic gas*; Trends: Minute volume, MAC and gases (02, N20, C02 and Anaesthetic gas).
  • Display for the performance of the hospital Anaesthetic Gas Scavenging System (AGSS).
  • Configurable interface: bright/dark, multi-language.
  • Loops (up to 2 simultaneously): Volume-Pressure, Flow-Volume, Pressure-Flow, C02-Volume.
  • Fresh gas virtual rotameters for 02, N20, Air. * C02, N20 and Anaesthetic gas monitoring with the accessory multigas analyzer main-stream or side-stream; 02 real-time monitoring via paramagnetic
 
Click Here To Download Catalogue
WeightN/AN/AN/AN/AN/AN/A
DimensionsN/AN/AN/AN/AN/AN/A
Additional information
Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • Rating
  • Price
  • Description
Click outside to hide the comparison bar
Compare