Infrared Sterilizer

Ask for Price$0.00

Shipped From Abroad

By precisely controlling the intensity of infrared radiation and irradiation time, Infrared Sterilizer can effectively kill all kinds of bacteria and viruses, which is a kind of efficient and environmentally friendly disinfection equipment. Widely used in hospitals, food factories, laboratories and other places that require sterile environment.

Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
SF1033560130127-14
Brands:: Scitek

Description

Infrared Sterilizer Features:
  • No flammable gas, no naked flame.
  • Infrared tungsten halogen lamp sterilization, sterilization temperature reach to 900-1300℃ in a few seconds, instantaneous heating, low energy consumption.
  • Infrared sensor control, automatically triggers the start, it can be operated with one hand.
  • Automatic termination after sterilization complete.
  • No preheating required, low cost of use.
  • Don’t consume oxygen when working, it can be used for microbial experiments in anaerobic chambers.
Infrared Sterilizer Specifications:
Model IR-950S
Maximum Temp in Central Zone 900~1300℃
Maximum Outer Diameter of

Sterilization Goods

Ø15mm
Length of Heating Area 100mm
Automatic Sterilization

Shutdown Time

7S
Power 600W
Voltage AC110V or 220V, 50/60Hz
Ambient Temperature 5~40℃
Sizes(WxDxH) 160x140x220mm
Shipping Size(WxDxH) 175x165x275mm
N.W./G.W. (kg) 2.7/3.2

 

Product Data

Infrared sterilizer can achieve very high temperatures, typically ranging from 900°C to 1300°C, within a matter of seconds. These high temperatures are critical for the effective destruction of microorganisms, including bacteria, viruses, and spores.

  • Maximum Temp in Central Zone (℃) : 900~1300
  • Maximum Outer Diameter of Sterilization Goods (mm) : Ø15
  • Length of Heating Area (mm) : 100
  • Automatic Sterilization Shutdown Time (s) : 7

Reviews

There are no reviews yet.

Be the first to review “Infrared Sterilizer”

Your email address will not be published. Required fields are marked *

Quick Comparison

Infrared Sterilizer removeNihon Kohden Neuropack S3 Electromyogram (EMG) Machine removeSyringe Needle Destroyer removeSiare Morpheus M Anaesthetic Machine removeSIGNERS SUPiA X-ray Digitizer ( CR Scanner) removeDirty Linen Trolley remove
NameInfrared Sterilizer removeNihon Kohden Neuropack S3 Electromyogram (EMG) Machine removeSyringe Needle Destroyer removeSiare Morpheus M Anaesthetic Machine removeSIGNERS SUPiA X-ray Digitizer ( CR Scanner) removeDirty Linen Trolley remove
ImageElectromyogram (EMG) MachineSIGNERS SUPiA X-ray Digitizer
SKUSF1033560130127-14SF1033560020-3SF1033560084-206SF1033560101-2SF1033560050-01SF1033560084-226
Rating
Price

Ask for Price$0.00

Ask for Price$0.00

$157.00

Ask for Price$0.00

Ask for Price$0.00

$76.00

Stock
Availability
Add to cart

DescriptionShipped From Abroad By precisely controlling the intensity of infrared radiation and irradiation time, Infrared Sterilizer can effectively kill all kinds of bacteria and viruses, which is a kind of efficient and environmentally friendly disinfection equipment. Widely used in hospitals, food factories, laboratories and other places that require sterile environment.
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped from abroad The Neuropack S3 combines Nihon Kohden’s gold-standard amplifiers with time-saving and easy-to-use clinical software, bringing neurodiagnostic labs a feature-rich system that provides cleaner, easier and faster data. The foundation of effective neurodiagnostic testing is a system that can provide a full complement of neurodiagnostic tests while also offering the quality needed to analyze and monitor nervous system function. Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.In stock Needle destruction destroy the needle immediately following its use. Needle destruction are an absolute necessity in developing parts of the world to prevent the reuse of needles and the spread of bloodborne pathogens. They are NOT a good alternative, however, for hospital use in the developed parts of the world. Needle destruction are products that bend, cut, or destroy the needle. This are distinctly different from needle destroyer that send an arc of electricity to vaporize and melt the needle.
Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped from Abroad The MORPHEUS M is an anaesthesia machine and it can be used on adult, children and newborn patients. The MORPHEUS M is suitable for administration of Oxygen – Air – Nitrous Oxide – Halothane – Enflurane – Isoflurane – Sevoflurane – Desflurane mixtures. Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped from Abroad SUPiA made by Signers offers such a better clinic environment with no chemicals, ideal space, high-resolution image quality, and affordability.

Delivery & Availability:

Typically 14 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock
No of Wheel 4
Usage Hospital
Cloth Material Synthetic
Pole Material Aluminium / SS
Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Content
Infrared Sterilizer Features:
  • No flammable gas, no naked flame.
  • Infrared tungsten halogen lamp sterilization, sterilization temperature reach to 900-1300℃ in a few seconds, instantaneous heating, low energy consumption.
  • Infrared sensor control, automatically triggers the start, it can be operated with one hand.
  • Automatic termination after sterilization complete.
  • No preheating required, low cost of use.
  • Don’t consume oxygen when working, it can be used for microbial experiments in anaerobic chambers.
Infrared Sterilizer Specifications:
Model IR-950S
Maximum Temp in Central Zone 900~1300℃
Maximum Outer Diameter of Sterilization Goods Ø15mm
Length of Heating Area 100mm
Automatic Sterilization Shutdown Time 7S
Power 600W
Voltage AC110V or 220V, 50/60Hz
Ambient Temperature 5~40℃
Sizes(WxDxH) 160x140x220mm
Shipping Size(WxDxH) 175x165x275mm
N.W./G.W. (kg) 2.7/3.2
 
Product Data
Infrared sterilizer can achieve very high temperatures, typically ranging from 900°C to 1300°C, within a matter of seconds. These high temperatures are critical for the effective destruction of microorganisms, including bacteria, viruses, and spores.
  • Maximum Temp in Central Zone (℃) : 900~1300
  • Maximum Outer Diameter of Sterilization Goods (mm) : Ø15
  • Length of Heating Area (mm) : 100
  • Automatic Sterilization Shutdown Time (s) : 7
The Neuropack S3 combines Nihon Kohden’s gold-standard amplifiers with time-saving and easy-to-use clinical software, bringing neurodiagnostic labs a feature-rich system that provides cleaner, easier and faster data. The foundation of effective neurodiagnostic testing is a system that can provide a full complement of neurodiagnostic tests while also offering the quality needed to analyze and monitor nervous system function. Features:
  • State-of-the-art low-noise amplifier with 18-bit A/D converters and artifact-reduction software provides clean waveforms
  • Built-in rejection ratios of 110 dB or greater (differential mode) and 112 dB or greater (isolation mode) limit variations in signals
  • Electrode input impedance of 200 MΩ ±20% helps ensure clean signals
  • On-screen examination guide directs electrode and stimulation placement for smooth and efficient examinations
  • HL7® gateway integration helps ensure quick flow of information and streamlines workflow
  • Intuitive control panel and stimulators aid in acquiring and progressing through studies
  • Customizable protocols shorten examination time
  • One-click report generation produces print-ready reports with customized logos, test results, exam waveforms and highlighted abnormal values
  • Proprietary all-in-one NCS program performs MCS, SCS and F-wave for quick examinations
  • Customized auto-copy settings allow waveforms to be stored and automatically transferred to long-term storage
  Technical Specifications: Main unit: DC-960B Electrode junction box, 2 or 4 ch: JB-962B or JB-964B Control unit, desktop: GG-961BK Power supply: SC-230BK Cart: KD-026A Arm: KH-960A Holder: DI-961B Somato control box: RY-960B LCD display: Local purchase Printer: Local purchase Number of channels: 2 or 4 Input impedance Common mode: >100 MΩ Differential Mode: >200 MΩ CMRR Differential Mode: >106 dB Isolation Mode: >112 dB Noise level: 0.6 μVrms Sampling Resolution: 18 bit Sensitivity: 1 to 500 μVrms/div., and 1 to 10 mVrms/div. Low-cut filter: 0.01 Hz to 3 kHz High-cut filter: 10 kHz to 20 kHz Analysis time base: 0.1 ms/div to 1 s /div Model Suffixes EEG-1200 has the following suffixies: J: 110-127 V AC operation K: 220-240 V AC operation  
Click Here To Download Catalogue
                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                             
Needle destruction destroys the needle immediately following its use. Needle destruction are an absolute necessity in developing parts of the world to prevent the reuse of needles and the spread of bloodborne pathogens. They are NOT a good alternative, however, for hospital use in the developed parts of the world. Needle destruction are products that bend, cut, or destroy the needle. This are distinctly different from needle destroyer that send an arc of electricity to vaporize and melt the needle. Features:
  • Well built
  • Easy to maintain
  • Having a rubbish drawer with alarm function, this is our most popular model of Syringe Destroyer for use in labs, pharma, universities and doctors clinics
  • With its low factory-direct price and excellent quality, its a great addition to add to any medical industry or university office that wants to ensure the safety and legal compliance of its operations
Specifications:
  • Short Name: Needle destruction / Needle Destroyer
  • Working Noise: ≤50 decibel
  • Superheating Sanitization Temperature: 95 deg C
  • Working Time: Can completely melt and destroy needle and neck of syringe in 5 seconds
  • Working Noise: ≤50 decibel
  • Dimensions: Approx. 38cm x 29cm x 28cm
  • Power: AC 110V or 220V
The MORPHEUS M is an anaesthesia machine and it can be used on adult, children and newborn patients. The MORPHEUS M is suitable for administration of Oxygen – Air – Nitrous Oxide – Halothane – Enflurane – Isoflurane – Sevoflurane – Desflurane mixtures. Features:
  • Mechanic gas mixing system
  • Electronic lung ventilator with 12” TFT colour display
  • Valves group: open, semi-closed, closed, heated, with soda lime absorber (1,5 Kg)
  • SIARETEX rapid connection device, Selectatec compatible for 2 vaporizers
  • Gas supply group
  • Ventilation modalities: APCV-PCV; APCV-TV; PSV; APNEA BACK-UP; VC-VAC; VC-VAC BABY; SIMV+PS (volumetric); SPONT; MANUAL.
  • Measured parameters: PAW; PEEP; Vte; ExpMV; Rate; I:E; FiO2, Pmax; Pmean; Pause; Vti; FLOWi; FLOWe; Tinsp; Tesp; Tpause; Cs; Ri
  • Displayed ventilation curves: Paw, Flow, Volume, Loop (Volume/Paw ; Volume/Flow)
  • Adjustable parameters: – O2 built-in Mixer device from 21% to 99% – I:E Adjustable Ratio: 1:1-1:2-1:3-1:4-2:1-3:1 – Inspiratory Flow – PEEP – Breathing Rate – Minute Volume; – Tidal Volume – Inspiratory Pressure Limit – Inspiratory Pause – Inspiratory Time – Trigger
  • Mechanic flowmeter module: 3-flow mechanical flow meter (O2 – N2O – AIR) with 5 flow meters for low flows. Equipped with safety systems (MIX-LIFE, CUT-OFF, flow meter protection valve).
  • Breathing system: The breathing system of Morpheus guarantees to the user an absolute flexibility and easy handling thanks to the noble construction materials employed. The valves group can be drawn-up and it’s totally autoclavable at 121°C and all its parts are manually dismountable, with no need of special tools.The breathing system is made of; Calibrated APL valve, Fresh gas collecting bag, O2 cell for reading of FiO2, Removable 1 kg soda lime canister, Manually inspectionable bellows jar, Safety valve for ambience air suction in case of fresh gas failure, Flow transducer inside the group located on the expiratory line.
Optional accessories 11054 AIRPAK 54 stand-alone medical air compressor 100150/IDF Isoflurane Vaporizer 100148/IDF Fluo-Halotane Vaporizer 100145/IDF Sevoflurane Vaporizer 100151/IDF Desflurane Vaporizer A57.049-800601 gas analysis module (5 AA – CO2 – N2O – O2 – MAC) ric.auto  
Click Here To Download Catalogue
                              )
SUPiA X-ray Digitizer made by Signers offers such a better clinic environment with no chemicals, ideal space, high-resolution image quality, and affordability FEATURE Rigid Type • No damage or scratch on image plates during scanning & erasing • Scanning & Erasing without a roller • No cut-off image during winter and cold period Durability • Extremely simple structure design • Strong aluminum base plate • Flip covers preventing dust from inside scanner Barcode System • Automatically recognising cassette sizes(14x17", 10x12", 18x24cm) by barcode reader Compact & lightweight design
  • Very small and compatible CR on desktop (only 63.5cm)
  • Only 21.5kg (47.4lbs)
Cassette Strong structure • Strong enough against external impact • Totally metal frame • Enduring under 150kg on cassette Featherlight • 14x17" : 2.05kg 10x12" : 0.99kg 18x24cm : 0.75kg Dust free & Easy cleaning • Easy to clean up dust on IPs • Prevent dust from outside User friendly design • Various colors 14x17"(Green), 10x12"(Blue), 18x24cm(Pink)) • Barcode label   TECHNICAL SPECIFICATION
  SUPiA Specifications
Cassette SUPiA CR Cassette 14x17 (inch) SUPiA CR Cassette 10x12 (inch) SUPiA CR Cassette 18x24 (cm)
Throughput Up to 94 IPs/hour (14x17"/160μm)
Slots Single Cassette feed
Dimensions (W x D x H) 436 x 636 x 196mm
Weight 21.5kg (47.4lbs)
Grayscale Resolution Acquisition : 16 bits per pixel Display : 12 bits per pixel
Power Supply Conditions Single Phase 50 ~ 60Hz AC 90 ~ 264V
Network 100 MBit
PC Connection USB 2.0
Computer Min. requirements

OS : Win 7 or 10

CPU : Intel i5

RAM : 4GB

Graphic Card : Intel HD 2500

HDD : 500GB

Monitor : FHD 1920 x 1080

Operating conditions Temperature : 10 ~ 30˚C Humidity : 15 ~ 85% RH
 
Click Here To Download Catalogue
No of Wheel 4
Usage Hospital
Cloth Material Synthetic
Pole Material Aluminium / SS
WeightN/AN/AN/AN/AN/AN/A
DimensionsN/AN/AN/AN/AN/AN/A
Additional information
Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • Rating
  • Price
  • Description
Click outside to hide the comparison bar
Compare