/

Infrared Sterilizer

$0.00

Shipped From Abroad

By precisely controlling the intensity of infrared radiation and irradiation time, Infrared Sterilizer can effectively kill all kinds of bacteria and viruses, which is a kind of efficient and environmentally friendly disinfection equipment. Widely used in hospitals, food factories, laboratories and other places that require sterile environment.

Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
SF1033560130127-14
Brands:: Scitek

Description

Infrared Sterilizer Features:
  • No flammable gas, no naked flame.
  • Infrared tungsten halogen lamp sterilization, sterilization temperature reach to 900-1300℃ in a few seconds, instantaneous heating, low energy consumption.
  • Infrared sensor control, automatically triggers the start, it can be operated with one hand.
  • Automatic termination after sterilization complete.
  • No preheating required, low cost of use.
  • Don’t consume oxygen when working, it can be used for microbial experiments in anaerobic chambers.
Infrared Sterilizer Specifications:
Model IR-950S
Maximum Temp in Central Zone 900~1300℃
Maximum Outer Diameter of

Sterilization Goods

Ø15mm
Length of Heating Area 100mm
Automatic Sterilization

Shutdown Time

7S
Power 600W
Voltage AC110V or 220V, 50/60Hz
Ambient Temperature 5~40℃
Sizes(WxDxH) 160x140x220mm
Shipping Size(WxDxH) 175x165x275mm
N.W./G.W. (kg) 2.7/3.2

 

Product Data

Infrared sterilizer can achieve very high temperatures, typically ranging from 900°C to 1300°C, within a matter of seconds. These high temperatures are critical for the effective destruction of microorganisms, including bacteria, viruses, and spores.

  • Maximum Temp in Central Zone (℃) : 900~1300
  • Maximum Outer Diameter of Sterilization Goods (mm) : Ø15
  • Length of Heating Area (mm) : 100
  • Automatic Sterilization Shutdown Time (s) : 7

Reviews

There are no reviews yet.

Be the first to review “Infrared Sterilizer”

Your email address will not be published. Required fields are marked *

Quick Comparison

SettingsInfrared Sterilizer removeOPTIKA B-383DK Trinocular Darkfeld Microscope removeDirty Linen Trolley removeSyringe Needle Destroyer removeFirst Aid Box Aluminium Large removeOPTIKA B-382PL-ALC Binocular Brightfeld Microscope remove
NameInfrared Sterilizer removeOPTIKA B-383DK Trinocular Darkfeld Microscope removeDirty Linen Trolley removeSyringe Needle Destroyer removeFirst Aid Box Aluminium Large removeOPTIKA B-382PL-ALC Binocular Brightfeld Microscope remove
ImageOPTIKA B-383DK Trinocular Darkfeld MicroscopeOPTIKA B-382PL-ALC Binocular Brightfeld Microscope
SKUSF1033560130127-14SF1033560098-14SF1033560084-226SF1033560084-206SF1033560084-251SF1033560098-13
Rating
Price

$0.00

$0.00

$76.00

$157.00

$69.50

$0.00

Stock
Availability
Add to cart

DescriptionShipped From Abroad By precisely controlling the intensity of infrared radiation and irradiation time, Infrared Sterilizer can effectively kill all kinds of bacteria and viruses, which is a kind of efficient and environmentally friendly disinfection equipment. Widely used in hospitals, food factories, laboratories and other places that require sterile environment.
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped from Abroad B-383DK - Darkfield Microscope Laboratory upright microscope for brightfield and darkfield observations with N-PLAN objectives (and W-PLAN 100x with iris) for biology and especially darkfield fresh blood analysis and the exclusive X-LED3 illumination system. The special condenser with integrated, exclusive X-LED3 illuminator replaces any other external and expensive lighting source required for these applications and is ideal for great-looking, rich and high-quality specimen view. Delivery & Availability: Typically 21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.In stock
No of Wheel 4
Usage Hospital
Cloth Material Synthetic
Pole Material Aluminium / SS
Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock Needle destruction destroy the needle immediately following its use. Needle destruction are an absolute necessity in developing parts of the world to prevent the reuse of needles and the spread of bloodborne pathogens. They are NOT a good alternative, however, for hospital use in the developed parts of the world. Needle destruction are products that bend, cut, or destroy the needle. This are distinctly different from needle destroyer that send an arc of electricity to vaporize and melt the needle.
Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock First Aid Box Aluminium Large contains variety of medical item for emergency rescue, it contains items from simple digital or disposable thermometers to hard to find first aid items such as medical scissors, and many other items that could help save a situation before being taken to the hospital for proper treatment.
Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped from Abroad The OPTIKA B-380 is an educational and laboratory microscope for routine applications. Dye-cast frame, with high stability and ergonomy, for transmitted light observation. Delivery & Availability: Typically 21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Content
Infrared Sterilizer Features:
  • No flammable gas, no naked flame.
  • Infrared tungsten halogen lamp sterilization, sterilization temperature reach to 900-1300℃ in a few seconds, instantaneous heating, low energy consumption.
  • Infrared sensor control, automatically triggers the start, it can be operated with one hand.
  • Automatic termination after sterilization complete.
  • No preheating required, low cost of use.
  • Don’t consume oxygen when working, it can be used for microbial experiments in anaerobic chambers.
Infrared Sterilizer Specifications:
Model IR-950S
Maximum Temp in Central Zone 900~1300℃
Maximum Outer Diameter of Sterilization Goods Ø15mm
Length of Heating Area 100mm
Automatic Sterilization Shutdown Time 7S
Power 600W
Voltage AC110V or 220V, 50/60Hz
Ambient Temperature 5~40℃
Sizes(WxDxH) 160x140x220mm
Shipping Size(WxDxH) 175x165x275mm
N.W./G.W. (kg) 2.7/3.2
 
Product Data
Infrared sterilizer can achieve very high temperatures, typically ranging from 900°C to 1300°C, within a matter of seconds. These high temperatures are critical for the effective destruction of microorganisms, including bacteria, viruses, and spores.
  • Maximum Temp in Central Zone (℃) : 900~1300
  • Maximum Outer Diameter of Sterilization Goods (mm) : Ø15
  • Length of Heating Area (mm) : 100
  • Automatic Sterilization Shutdown Time (s) : 7
Observation mode: Brightfield, oil immersion darkfield. Head: Trinocular (fixed 50/50), 30° inclined, 360° rotating. Interpupillary distance: Adjustable between 48 and 75 mm. Dioptric adjustment: On the left eyepiece tube. Eyepieces: WF10x/20 mm, high eye-point and secured by screw. Nosepiece: Quintuple revolving nosepiece, rotation on ball bearings. Objectives: N-PLAN 4x/0.10 N-PLAN 10x/0.25 N-PLAN 40x/0.65 W-PLAN 100x/1.25 (oil) with iris All with anti-fungus treatment. Specimen stage: Double layer rackless mechanical stage, 150×139 mm, 75×33 mm X-Y range. Focusing: Coaxial coarse (adjustable tension) and fine focusing mechanism with limit stop to prevent the contact between objective and specimen. Brightfield condenser: Abbe N.A. 1.25, with objective-coded iris diaphragm, focusable and centerable. Darkfieldfield condenser: Darkfield N.A. 1.36 (oil immersion) with built-in X-LED3. Transmitted illumination (Fixed Koehler type): X-LED3 with white 3.6 W LED (6,300K) with brightness control. Multi-plug 100-240Vac/6Vdc external power supply.  
Click Here To Download Catalogue
No of Wheel 4
Usage Hospital
Cloth Material Synthetic
Pole Material Aluminium / SS
Needle destruction destroys the needle immediately following its use. Needle destruction are an absolute necessity in developing parts of the world to prevent the reuse of needles and the spread of bloodborne pathogens. They are NOT a good alternative, however, for hospital use in the developed parts of the world. Needle destruction are products that bend, cut, or destroy the needle. This are distinctly different from needle destroyer that send an arc of electricity to vaporize and melt the needle. Features:
  • Well built
  • Easy to maintain
  • Having a rubbish drawer with alarm function, this is our most popular model of Syringe Destroyer for use in labs, pharma, universities and doctors clinics
  • With its low factory-direct price and excellent quality, its a great addition to add to any medical industry or university office that wants to ensure the safety and legal compliance of its operations
Specifications:
  • Short Name: Needle destruction / Needle Destroyer
  • Working Noise: ≤50 decibel
  • Superheating Sanitization Temperature: 95 deg C
  • Working Time: Can completely melt and destroy needle and neck of syringe in 5 seconds
  • Working Noise: ≤50 decibel
  • Dimensions: Approx. 38cm x 29cm x 28cm
  • Power: AC 110V or 220V
First Aid Box Aluminium Large contains variety of medical item for emergency rescue, it can contain items from simple digital or disposable thermometers to hard to find first aid items such as medical scissors, and many other items that could help save a situation before being taken to the hospital for proper treatment.Observation mode: Brightfield. Head: Binocular, 30° inclined, 360° rotating (when ALC cable is unplugged). Interpupillary distance: Adjustable between 48 and 75 mm. Dioptric adjustment: On the left eyepiece tube. Eyepieces: WF10x/20 mm, high eye-point and secured by screw. Nosepiece: Quintuple revolving nosepiece, rotation on ball bearings. Objectives: N-PLAN 4x/0.10 N-PLAN 10x/0.25 N-PLAN 40x/0.65 N-PLAN 100x/1.25 (Oil/Water) All with anti-fungus treatment. Specimen stage: Double layer rackless mechanical stage, 150×139 mm, 75×33 mm X-Y range. Focusing: Coaxial coarse (adjustable tension) and fine focusing mechanism with limit stop to prevent the contact between objective and specimen. Condenser: Abbe N.A. 1.25, with objective-coded iris diaphragm, focusable and centerable. Illumination (Fixed Koehler type): X-LED3 with white 3.6 W LED (6,300K) and brightness control. ALC system. Multi-plug 100-240Vac/6Vdc external power supply.  
Click Here To Download Catalogue
WeightN/AN/AN/AN/AN/AN/A
DimensionsN/AN/AN/AN/AN/AN/A
Additional information
Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • Rating
  • Price
  • Description
Click outside to hide the comparison bar
Compare