Infusion patch

$0.00

Shipped From Abroad

Other product series of infusion patches are used to solve the problem that existing infusion patches may cause pain when separated, or cannot quickly press the needle hole with a cotton swab, causing bleeding and discomfort to the patient, affecting the recovery of the needle hole. It includes: a T-shaped substrate, the T-shaped substrate is composed of a vertically arranged horizontal substrate and a longitudinal substrate, a layer of silicone gel is provided on the longitudinal substrate, a fixing groove is provided on the silicone gel, a disinfection pad is provided on the horizontal substrate, the T-shaped substrate is a PU film, and the fixing groove is composed of a needle handle fixing groove and a needle body fixing groove. The depth of the needle handle fixing groove is not more than 3mm, and the depth of the needle body fixing groove is not more than 0.5mm. In the infusion patch of this utility model, the infusion needle can be set in the fixed groove when in use, and there will be no pain when separating the infusion patch. In addition, a disinfection pad is provided on the infusion patch, which effectively prevents the problems of redness, swelling, suppuration, inflammation and the like of the needle eye caused by incomplete disinfection before acupuncture. It is convenient and comfortable to use. PARMETERS Infusion Patch

Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
SF1033560130104-11

Description

Product details

The infusion patch is used to solve the problem that the existing infusion patch may cause pain when being separated, or that the needle hole cannot be quickly pressed with a cotton swab, causing bleeding and causing discomfort to the patient, which affects the recovery of the needle hole. It includes: a T-shaped substrate, the T-shaped substrate is composed of a vertically arranged horizontal substrate and a longitudinal substrate, a layer of silicone gel is arranged on the longitudinal substrate, a fixing groove is arranged on the silicone gel, a disinfection pad is arranged on the horizontal substrate, the T-shaped substrate is a PU film, and the fixing groove is composed of a needle handle fixing groove and a needle body fixing groove. The depth of the needle handle fixing groove is not more than 3mm, and the depth of the needle body fixing groove is not more than 0.5mm. When using the infusion patch of the utility model, the infusion needle can be set in the fixing groove, and no pain will be generated when separating the infusion patch. In addition, a disinfection pad is arranged on the infusion patch, which effectively prevents the problems of redness, swelling, suppuration, inflammation, etc. of the needle hole caused by incomplete disinfection before acupuncture. It is convenient and comfortable to use.

Product parameters

Product name Part Number Dimensions (cm)
Medical breathable tape W125 1.25cm×9.14m Non-woven fabric
W250 2.5cm×9.14m non-woven fabric
E125 1.25cm×9.14m PE punching
E250 2.5cm×9.14m PE punching
Tourniquet ZCC-20 2×35cm flat
cummerbund 8×42cm
Swimming stickers B0607S 6×7cm
cummerbund C0407 4×7cm

Reviews

There are no reviews yet.

Be the first to review “Infusion patch”

Your email address will not be published. Required fields are marked *

Quick Comparison

SettingsInfusion patch removeIntersurgical Solus i-gel LMA (Size; 2, 3, 4 & 5) removeMaico TouchTymp MI36 Tympanometry removeBistos BT- 720 Patient Monitor removeBistos BT- 740 Patient Monitor removeMaico MA25 Audiometer remove
NameInfusion patch removeIntersurgical Solus i-gel LMA (Size; 2, 3, 4 & 5) removeMaico TouchTymp MI36 Tympanometry removeBistos BT- 720 Patient Monitor removeBistos BT- 740 Patient Monitor removeMaico MA25 Audiometer remove
ImageMaico TouchTymp MI36 Tympanometry and AmpBistos BT-720 Patient MonitorBistos BT- 740 Patient MonitorMaico MA25 Audiometer
SKUSF1033560130104-11SF1033560084-20SF1033560063-10SF1033560059-8SF1033560059-9SF1033560063-5
Rating
Price

$0.00

$12.75

$0.00

$330.00

$715.00

$0.00

Stock
Availability
Add to cart

DescriptionShipped From Abroad Other product series of infusion patches are used to solve the problem that existing infusion patches may cause pain when separated, or cannot quickly press the needle hole with a cotton swab, causing bleeding and discomfort to the patient, affecting the recovery of the needle hole. It includes: a T-shaped substrate, the T-shaped substrate is composed of a vertically arranged horizontal substrate and a longitudinal substrate, a layer of silicone gel is provided on the longitudinal substrate, a fixing groove is provided on the silicone gel, a disinfection pad is provided on the horizontal substrate, the T-shaped substrate is a PU film, and the fixing groove is composed of a needle handle fixing groove and a needle body fixing groove. The depth of the needle handle fixing groove is not more than 3mm, and the depth of the needle body fixing groove is not more than 0.5mm. In the infusion patch of this utility model, the infusion needle can be set in the fixed groove when in use, and there will be no pain when separating the infusion patch. In addition, a disinfection pad is provided on the infusion patch, which effectively prevents the problems of redness, swelling, suppuration, inflammation and the like of the needle eye caused by incomplete disinfection before acupuncture. It is convenient and comfortable to use. PARMETERS Infusion Patch
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock
  • Made of medical grade Silicone, have good biocompatibility, non-toxic.
  • Exclusive soft seal cuff can be insert comfortable, minimizing potential trauma and increasing sealing.
  • Strengthen neck and tip eases insertion and prevents folds.
  • Kink-free tube eliminates the risk of airway tube occlusion.
  • Have different size, suitable for neonate, infant, child and adult.
  • Different color cuff, different material cuff, with aperture bar or not.
  • Reusable types must be cleaned and disinfected or sterilizated before use only 40 times.
Delivery & Availability: Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped from Abroad TouchTymp MI 36 combines diagnostic middle ear analyzer and audiometry tests in one exceptional device. The full 10.4" touchscreen with its user-friendly interface guarantees a unique intuitive operation and allows to quickly change parameters. You can easily switch between the tests without reorganizing from one to another device and beneft from its small footprint when facing limited desk space. touchTymp MI 36 really improves your workflow every day. Delivery & Availability: Typically 10 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.Shipped from abroad Bistos BT - 720 Patient Monitor: Bistos Portable Patient Vital Signs Monitor, SpO2, Pulse, *NIBP, BT-720. The Bistos BT-720 is a compact size vital signs monitor with the standard parameters of SpO2 and Pulse. You can also add the NIBP and/or Masimo SpO2 at an additional cost. The BT-720 has a 4.3" color touch screen The PC software allows the vital signs information to be transferred and analyzed on a computer. Delivery & Availability: Typically 7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.Shipped from Abroad Bistos BT - 740 Patient Monitor: Bistos Patient Vital Signs Monitor, ECG, Resp., SpO2, NIBP, Temp., BT-740. The Bistos BT-740 is a multi-parameter patient monitor with an 8.4" TFT Color screen. The standard paramaters are ECG, respiratory, SpO2, NIBP and temperature. Additional options are EtCO2, IBP, Multi-gas, CO and Masimo SpO2. The BT-740 has a fanless design for quiet operation. Delivery & Availability: Typically 7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.Shipped from Abroad the Ma 25 offers a full range of testing opportunities. frequencies range from 125 Hz to 8000 Hz and signal intensities run from -10 dBHL to 100 dBHL. Sinus and warble tone (pulsed and continuous) make it complete. Delivery & Availability: Typically 10 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Content

Product details

The infusion patch is used to solve the problem that the existing infusion patch may cause pain when being separated, or that the needle hole cannot be quickly pressed with a cotton swab, causing bleeding and causing discomfort to the patient, which affects the recovery of the needle hole. It includes: a T-shaped substrate, the T-shaped substrate is composed of a vertically arranged horizontal substrate and a longitudinal substrate, a layer of silicone gel is arranged on the longitudinal substrate, a fixing groove is arranged on the silicone gel, a disinfection pad is arranged on the horizontal substrate, the T-shaped substrate is a PU film, and the fixing groove is composed of a needle handle fixing groove and a needle body fixing groove. The depth of the needle handle fixing groove is not more than 3mm, and the depth of the needle body fixing groove is not more than 0.5mm. When using the infusion patch of the utility model, the infusion needle can be set in the fixing groove, and no pain will be generated when separating the infusion patch. In addition, a disinfection pad is arranged on the infusion patch, which effectively prevents the problems of redness, swelling, suppuration, inflammation, etc. of the needle hole caused by incomplete disinfection before acupuncture. It is convenient and comfortable to use.

Product parameters

Product name Part Number Dimensions (cm)
Medical breathable tape W125 1.25cm×9.14m Non-woven fabric
W250 2.5cm×9.14m non-woven fabric
E125 1.25cm×9.14m PE punching
E250 2.5cm×9.14m PE punching
Tourniquet ZCC-20 2×35cm flat
cummerbund 8×42cm
Swimming stickers B0607S 6×7cm
cummerbund C0407 4×7cm
 
Features:
  • Made of medical grade Silicone, have good biocompatibility, non-toxic.
  • Exclusive soft seal cuff can be insert comfortable, minimizing potential trauma and increasing sealing.
  • Strengthen neck and tip eases insertion and prevents folds.
  • Kink-free tube eliminates the risk of airway tube occlusion.
  • Have different size, suitable for neonate, infant, child and adult.
  • Different color cuff, different material cuff, with aperture bar or not.
  • Reusable types must be cleaned and disinfected or sterilizated before use only 40 times.
 
 
TouchTymp MI 36 combines diagnostic middle ear analyzer and audiometry tests in one exceptional device. The full 10.4" touchscreen with its user-friendly interface guarantees a unique intuitive operation and allows to quickly change parameters. You can easily switch between the tests without reorganizing from one to another device and beneft from its small footprint when facing limited desk space. touchTymp MI 36 really improves your workflow every day. FEATURES AT A GLANCE
  • Combo device with small footprint
  • Customizable to suit individual needs
  • High resolution and quick screen transitions
  • Full touch-based interface for intuitive handling
  • Probe tone 226 Hz, 678 Hz, 800 Hz
  • Optional high-frequency probe tone 1 kHz
  • Acoustic reflex stimuli 500 Hz,1 kHz, 2 kHz, 4 kHz, BB, HP, LP (ipsilateral and contralateral)
  • Reflex Decay test (ipsilateral and contralateral)
  • ETF test for intact and perforated eardrums
  • Air conduction audiometry
  • Bone conduction audiometry
  • Built-in printer or data transfer to PC
  • Optional MAICO Sessions PC Software connectable with OtoAccess® or Noah patient database for easy data management
Comprehensive test protocols
  • Our touchTymp MI 36 provides comprehensive standard protocols for immediate operation of screening and diagnostic test processes: tympanometry with 226 Hz, tympanometry with automatic or fxed acoustic reflexes, reflex decay, Eustachian tube function testing (ETF) plus air conduction and bone conduction audiometry. The optional high-frequency probe tone of 1 kHz is ideal for providing reliable results when testing newborns
Stay focused on your patients
  • The unique touchTymp light bar on our shoulder box probe provides a real-time progression of the immittance test. The shoulder box can easily be clipped to your patient's top for controlled handling of the diagnostic probe. The light indicator shows you which ear is tested and the test result.
Printing made easy
  • Print test results instantly by using the touchTymp built-in printer. Place the shoulder box into its holder to automatically start printing. You can transfer the results to a PC to allow long term storage, full page printout and PDF creation for EMR integration.
Compatible to Sessions: Get ready for fast data transfer!
  • Use the touchTymp MI 36 with our intuitive data transfer solution Sessions, for easy management and visualization of your immittance measurements.
  TECHNICAL SPECIFICATION Tympanometry
  • Probe Frequency - 226 Hz ± 1 %, 85 dBSPL ± 1.5 dB, 678 Hz ± 1%, 72 dBSPL ± 1.5 dB, 800 Hz ± 1%, 70.5 dBSPL ± 1.5 dB
  • Optional High Frequency - 1 kHz ± 1%, 69 dBSPL ± 1.5 dB
  • Pressure Range - -600 to + 400 daPa
  • Accuracy of Pressure - ± 5 % or ± 10 daPa
  • Volume Range - 0.0 to 6.0 ml (compensated)
  • Compliance Range - 0.1 to 8.0 ml at 226 Hz, 0.1 to 15.0 mmho at 678, 800 and 1000 Hz
  • Accuracy of Volume - ± 5 % or 0.1 ml
  • Test Time Measurement - 3 - 5 seconds
Acoustic Reflexes
  • Test Frequencies - 0.5, 1, 2, 4 kHz ± 1 %
  • Test Noise - BB, LP, HP
  • Test Methods - Ipsilateral, contralateral
  • Level Ipsilateral - 70 to 105 dBHL
  • Level Contralateral - 70 to 120 dBHL
  • Level Setting - Automatic, fxed
  • Ipsilateral Reflex - Test With AGC
Reflex Decay
  • Standard - Probe frequency 226 Hz
  • Test Frequencies - 0.5, 1, 2, 4 kHz ± 1 %
  • Test Noise - BB, LP, HP
  • Level Ipsilateral - 70 to 105 dBHL
  • Level Contralateral - 70 to 120 dBHL
Eustachian Tube Function
  • Test Methods - Intact and perforated
  • Pressure Range - -600 to + 400 daPa
Audiometry
  • Test Signals - Sinus and warble tone, (pulsed and continuous)
  • Test Frequencies - 125, 250, 500, 750, 1000, 1500, 2000, 3000, 4000, 6000, 8000 Hz (125 Hz excluded
  • from bone conduction test frequencies)
  • Level Steps - 5 or 1 dB
  • Hearing Level Range AC - -10 to 120 dBHL
  • Hearing Level Range BC -  -10 to 80 dBHL
  • Masking Noise - Narrow band and white noise
Device General
  • Display - 10.4" Graphic LED-Display with resistive touchscreen
  • PC Interface - USB
  • Probe - Lightweight diagnostic Shoulder-Box with built-in control light and switch
  • Printer - Fast 4 inch thermal printer
  • Power Supply - Mains 100 to 240 V~ ± 10 %, 50 - 60 Hz ± 10 %
  • Dimensions / Weight - W 30 x D 34.5 x H 14.8 cm / 3.2 kg
  • Languages - English, German, Spanish, French, Polish, Turkish, Russian, Chinese
 
Click Here To Download Catalogue
Bistos BT - 720 Patient Monitor: Bistos Portable Patient Vital Signs Monitor, SpO2, Pulse, *NIBP, BT-720. The Bistos BT-720 is a compact size vital signs monitor with the standard parameters of SpO2 and Pulse. You can also add the NIBP and/or Masimo SpO2 at an additional cost. The BT-720 has a 4.3" color touch screen The PC software allows the vital signs information to be transferred and analyzed on a computer. Features:
  • 3" color touch screen
  • Standard Confirgurations: SpO2 and Pulse
  • Optioal NIBP and Masimo SpO2
  • Short/long trend graphic/trend table display
  • Audio and visual alarm, adjustable alarm limit
  • Automatic brightness adjustment
  • Accurate SpO2 reading during motion or low perfusion
  • Perfusion index data / bar graphic display
  • Pitch tone variation for pulse rate
  • Internal memory for data storage
  • SD card for easy software upgrade
  • Over 8 hours of operation with the re-chargeable li-ion battery
  • PC software for data review and analysis on a computer
  Technical Specifications:
Model BT-720
Display 4.3" Color LCD Touch Screen
SpO2 Measurement Range 0-100%
Accuracy (70-100%) Adult/Pediatric +/- 2%
Neonate +/- 3%
Accuracy (0-69%) Unspecified
Perfusion Index 0.05-20%
Pulse Rate Range (bpm) 25-250
NIBP* (Optional) Method Automatic Oscillometric
Operation Mode Manual/Automatic/STAT
Parameter Systolic/Diastolic/Mean
Systolic Range (mmHg) Adult 40-270
Pediatric 40-200
Neonate 40-130
Diastolic Range Adult 100-210
Pediatric 100-160
Neonate 10-90
Mean Range Adult 20-230
Pediatric 20-175
Neonate 20-100
SpO2 Masimo* (Optional) Masimo SpO2
Battery Type (Capacity) Li-ion (4400mAh)
Run time 8 Hours
Charging Time 8 Hours
Interface RJ45, SD Card Slot
Warranty 2 Years
 
Click Here To Download Catalogue
 
Bistos BT - 740 Patient Monitor: Bistos Patient Vital Signs Monitor, ECG, Resp., SpO2, NIBP, Temp., BT-740. The Bistos BT-740 is a multi-parameter patient monitor with an 8.4" TFT Color screen. The standard paramaters are ECG, respiratory, SpO2, NIBP and temperature. Additional options are EtCO2, IBP, Multi-gas, CO and Masimo SpO2. The BT-740 has a fanless design for quiet operation. Features:
  • 8.4" TFT Color Screen - (Optional Touch Screen Upgrade)
  • Standard parameters are ECG, Resp., SpO2, NIBP, Temp.
  • Ultra-low power consumption
  • Quiet operation
  • High accuracy SpO2 reading
  • Data transfer or firmware upgrade via USB
  • 2 Years Manufacturer's Warranty
  Technical Specifications:
Model BT-740
Display 8.4" Color TFT Screen
ECG Lead type 3/5 Lead
Gain Selection x0.25, x0.5, x1, x2, x4, auto
Sweep speed (mm/s) 12.5, 25, 50
Bandwith:(Diagnostic Mode) 0.05-130Hz
Monitoring Mode 0.5-40Hz
Surgery Mode 1-25Hz
Strong Mode 5-20Hz
Heart Rate Range (bpm) Adult:15-300
Pediatric/neonate: 15-350
Respiration Method Trance-thoracic Impedance
Measurement Range 0-120rpm
Sweep Speed (mm/s) 6.25, 12.5, 25
SpO2 Measurement Range 0-100%
Accuracy (70-100%) Adult/Pediatric +/-2%
Neonate +/-3%
Accuracy (0-69%) Unspecified
Perfusion Index 0.05-20%
Pulse Rate Range (bpm) 25-250bpm
NIBP** Method Automatic (Oscillometric)
Operation Mode Manual/Auto/STAT
Parameter Systolic, Diastolic, Mean
Systolic Range (mmHg) Adult 40-270
Pediatric 40-200
Neonate 40-130
Diastolic Range (mmHg) Adult 10-210
Pediatric 10-160
Neonate 10-90
Mean Range (mmHg) Adult 20-230
Pediatric 20-175
Neonate 20-100
Temperature Range 0-50°C
Parameter T1, T2 and TD
IBP" Channel 2 Channel, 4 Channel
Range (mmHg) -50-400
Printer* Type Thermal dot array
Print Speed (mm/s) 12.5, 25, 50
Paper Size (mm) 50
CO2* Sidestream Masimo ISA / Bistos
Mainstream Masimo IRMA / Bistos
Multi-gas O2* Masimo ISA
SpO2 Masimo* Masimo SpO2
CO* Method Thermodilution
Range 0.2-20 L/min
Battery Type (Capacity) Li-ion (440mAh)
Run Time 6 hour
Charging Time 4 hour
Interface RJ45, USB, Nursing Call
Warranty 2 Years
 
Click Here To Download Catalogue
 
MA 25 offers a full range of testing opportunities. frequencies range from 125 Hz to 8000 Hz and signal intensities run from -10 dBHL to 100 dBHL. Sinus and warble tone (pulsed and continuous) make it complete. FEATURES AT A GLANCE • air conduction with 11 frequencies from 125 to 8000 Hz • customize the frequencies to your own needs • Operated with 3 standard AA batteries or with a medically approved external power supply (optional) • pure, pulse, warble tones • Exceptionally lightweight, only 980 g • Ma 25e extends functionality of Ma 25 SLEEK AND SMALL DESIGN the super-lightweight Ma 25 weighs in at only 980 g. Small enough to hold in the palm of your hand! tucked into its carrying case, the Ma 25 is one of our smallest, lightest portables. ACCURATE AND DEPENDABLE ENGINEERING Because it is portable, the Ma 25 has been engineered to be tough and reliable. take the Ma 25 everywhere with confidence. User-friendly knobs make adjusting frequency and hearing levels easy and comfortable! MA 25E EXTENDS FUNCTIONALITY OF MA 25 the Ma 25e extends the Ma 25 functionalities with an automatic test according to Hughson-Westlake. parameters can easily be adapted to your personal preferences. the talk forward function makes the Ma 25e easy to work with, particularly in sound booth installations. TECHNICAL SPECIFICATION
  • Test Signals - Sinus and warble tone (pulsed and continuous)
  • Test Frequencies Hz - 125, 250, 500, 750, 1000, 1500, 2000, 3000, 4000, 6000, 8000
  • Level Steps - 5 or 1 dB
  • Hearing Level Range - 90 dBHL at 0.25 and 8 kHz, 70 dBHL at 0.125 kHz, -10 dBHL - 100 dBHL
  • Audiometer Class - Class 4 according to En 60 645-1
  • Power Supply - 3 AA batteries (100 hours life time typically) or optional power supply
Click Here To Download Catalogue
WeightN/AN/AN/AN/AN/AN/A
DimensionsN/AN/AN/AN/AN/AN/A
Additional information
Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • Rating
  • Price
  • Description
Click outside to hide the comparison bar
Compare