Low Temperature Formaldehyde Steam Sterilizer

$0.00

Shipped From Abroad

The low-temperature steam formaldehyde sterilizer uses a vacuum system to create a low-pressure environment in the sterilization room. In the low-pressure environment, the formaldehyde solution is vaporized to form low-temperature formaldehyde vapor. The formaldehyde vapor is used to act on the items in the sterilization room, causing microbial proteins and genetic substances on the items to denature and cause microbial death, in order to achieve the purpose of sterilization.

Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
SF1033560130127-6
Brands:: Scitek

Description

Formaldehyde Steam Sterilizer Applications:

Mainly used for low-temperature sterilization of heat and moisture resistant items, it can be used in operating rooms, supply rooms, endoscopy rooms, and other treatment rooms in medical institutions.

Formaldehyde Steam Sterilizer Specifications:
Model ST-FT100 ST-FT130 ST-FT150
Capacity 100L 130L 150L
Chamber Size(WxDxH) 700x430x360mm 750x450x400mm 820x645x400mm
Consumption 5.3KW
Sterilizer Solution 2% formaldehyde, 3% alcohol, and 95% distilled water solution
Sterilizer Solution Packaging Specification 2L
Single Cycle Dosage 0.6-1.3Kg
Operating Temperature 60℃ and 76℃
Sterilization Time 2-3.5 hours
Water Consumption 3.95Kg/min
Heating Method Electric heating
Anti-pressure 5pa
Operation Height ≤160cm
Chamber Material 5052 corrosion resistant aluminum alloy, with antioxidant treated
Cabinet Material ABS
Door Panel Material 5052 corrosion resistant aluminum alloy, with antioxidant treated, ≥10mm
Pipe Materials SS304 stainless steel
Insulation Materials High quality insulation cotton
Door Form Automatic door
Display 8 inch Touch Screen
External Size(WxDxH)(mm) 1070x790x1770
Package Size(WxDxH)(mm) 1200x900x1980
Low Temperature Formaldehyde Steam Sterilizer Features:
  • Loading method: A movable stainless steel basket with support rods to avoid stacking items.
  • Control system: Adopting Siemens PLC control system and friendly human-machine interaction interface, safe and reliable; One click start to finish, the entire process is automatically completed, displaying information such as temperature, pressure, sterilization time, etc. The system can be maintained and upgraded.
  • Heating system: PID temperature controller is used to control the door, inner tank, and steam generator respectively and ensure their working stability.
  • Display function: It can display temperature, pressure, time, operating mode, and alarm information.
  • Power outage memory function: reduces operating costs and risk of misoperation.
  • Steam generator: A self-developed fast evaporator that not only improves the vaporization rate of formaldehyde solution, but also enhances the sterilization effect.
  • Cleaning and drying function: With the independent addition of automatic cleaning and drying function, it greatly reduces the formaldehyde residue in the processed items while ensuring the basic requirement of not getting wet, ensuring that it is below the national standard value.
  • Automatic dosing function: Unique formaldehyde solution soft bag filling technology, automatic puncture filling, to avoid manual risks.
  • Printing function: capable of printing program name, sterilization date, sterilization pot number, sterilization start and end time, as well as pressure, temperature, stage time and other information of each stage of the sterilization process. Printing records should be kept for more than 5 years.
  • Storage function: Store sterilization data for no less than 15000 cycles, including program name, sterilization date, sterilization cycles, sterilization start and end time, as well as pressure, temperature, stage time, and end status of each stage of the sterilization process.
  • Alarm system: There is a high temperature alarm system.
  • Network connection: Equipped with a network connection port.
  • Vacuum pump: Adopting a German water ring vacuum pump with reliable quality, it not only meets the design pressure requirements of the sterilizer, but also accelerates the decomposition and absorption of formaldehyde vapor to a certain extent, with a higher safety factor.
  • Air filter: filtration accuracy ≤ 0.22 μ M;
  • Pressure sensor: The built-in pressure sensor uses high-precision sensors to automatically detect the pressure inside the cavity, ensuring that the accuracy of the pressure inside the cavity is controlled within an effective range.
  • Temperature sensor: embedded temperature sensor automatically detects the temperature inside the cavity, ensuring that the accuracy of the temperature inside the cavity is controlled within an effective range.
  • Multiple protection functions: equipped with multiple protection functions such as overvoltage, undervoltage, overtemperature, door failure, and door safety interlock device

Reviews

There are no reviews yet.

Be the first to review “Low Temperature Formaldehyde Steam Sterilizer”

Your email address will not be published. Required fields are marked *

Quick Comparison

SettingsLow Temperature Formaldehyde Steam Sterilizer removeDrGem Ceiling Mounted Digital X-ray removeASPEL AsCARD Grey ECG Machine removeASPEL Stress ECG with Ergometer and Software removeBistos BT-770-12.1" Touchscreen Patient Monitor removeDrGem GXR-SD 400mA Floor Mounted Digital X-ray remove
NameLow Temperature Formaldehyde Steam Sterilizer removeDrGem Ceiling Mounted Digital X-ray removeASPEL AsCARD Grey ECG Machine removeASPEL Stress ECG with Ergometer and Software removeBistos BT-770-12.1" Touchscreen Patient Monitor removeDrGem GXR-SD 400mA Floor Mounted Digital X-ray remove
ImageDrGem GXR-SD 400mA Ceiling Mounted Digital X-ray MachineASPEL AsCARD Grey ECG MachineASPEL Stress ECG and ErgometerBistos BT-770-12.1" Touchscreen Patient MonitorDrGem GXR-SD 400mA Floor Mounted Digital X-ray Machine
SKUSF1033560130127-6SF1033560074-4SF1033560075-5SF1033560075-1SF1033560059-1SF1033560074-5
Rating
Price

$0.00

$0.00

$1,166.00

$4,202.00

$902.00

$0.00

Stock
Availability
Add to cart

DescriptionShipped From Abroad The low-temperature steam formaldehyde sterilizer uses a vacuum system to create a low-pressure environment in the sterilization room. In the low-pressure environment, the formaldehyde solution is vaporized to form low-temperature formaldehyde vapor. The formaldehyde vapor is used to act on the items in the sterilization room, causing microbial proteins and genetic substances on the items to denature and cause microbial death, in order to achieve the purpose of sterilization.
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In Stock The GXR-SD is a diagnostic digital radiography system that provides reliable high quality digital radiographic images with a reduced dose. The GXR-SD DR systems offer comprehensive digital solutions to all radiography needs, featuring ACQUIDR digital imaging system with stationary or portable digital flat-panel detectors as well as reliable high-frequency x-ray generators that are known worldwide for their excellent performance, lifetime and stability. Patient tables and wall stands are also offered. Delivery & Availability: Typically 21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.Shipped from Abroad Electrocardiograph AsCARD Grey v.07.225 - is a 1, 3, 6, 12 channel ECG unit which enables to make electrocardiogram in full 12 leads. It is intended to conduct ECG examinations of adults and paediatric patients in all types of health care centres. ECG examination may be recorded in manual or automatic mode, with the possibility of analysis and interpretation. The device can be powered from 100 V ÷ 240 V mains supply or by an internal battery. Delivery & Availability: Typically 10 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.Shipped from Abroad Ergometer CRG 200 is dedicated for Exercise Stress Tests System CardioTEST. The Ergometer has been designed according to modern technologies. It is controlled from PC equipped in CardioTEST software. Load level is controlled by a microprocessor, therefore it does not depend on speed, which in turn can be adjusted according to patient’s individual needs. Ergometer is equipped with ECG mode recording 12 standard leads. Delivery & Availability: Typically 21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.Shipped from Abroad The Bistos BT-770 patient monitor is equipped with a 12.1" touchscreen display, which allows for an easy operation and readability with a powerful rechargeable battery guaranteeing a continuous operation of 5 hours to monitor ECG, SpO2, NIBP, temperature and respiration Delivery & Availability: Typically 14 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.In Stock The GXR-SD Digital X-ray is a diagnostic digital radiography system that provides reliable high quality digital radiographic images with a reduced dose. The GXR-SD DR systems offer comprehensive digital solutions to all radiography needs, featuring ACQUIDR digital imaging system with stationary or portable digital flat-panel detectors as well as reliable high-frequency x-ray generators that are known worldwide for their excellent performance, lifetime and stability. Patient tables and wall stands are also offered. Delivery & Availability: Typically 21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Content
Formaldehyde Steam Sterilizer Applications:
Mainly used for low-temperature sterilization of heat and moisture resistant items, it can be used in operating rooms, supply rooms, endoscopy rooms, and other treatment rooms in medical institutions.
Formaldehyde Steam Sterilizer Specifications:
Model ST-FT100 ST-FT130 ST-FT150
Capacity 100L 130L 150L
Chamber Size(WxDxH) 700x430x360mm 750x450x400mm 820x645x400mm
Consumption 5.3KW
Sterilizer Solution 2% formaldehyde, 3% alcohol, and 95% distilled water solution
Sterilizer Solution Packaging Specification 2L
Single Cycle Dosage 0.6-1.3Kg
Operating Temperature 60℃ and 76℃
Sterilization Time 2-3.5 hours
Water Consumption 3.95Kg/min
Heating Method Electric heating
Anti-pressure 5pa
Operation Height ≤160cm
Chamber Material 5052 corrosion resistant aluminum alloy, with antioxidant treated
Cabinet Material ABS
Door Panel Material 5052 corrosion resistant aluminum alloy, with antioxidant treated, ≥10mm
Pipe Materials SS304 stainless steel
Insulation Materials High quality insulation cotton
Door Form Automatic door
Display 8 inch Touch Screen
External Size(WxDxH)(mm) 1070x790x1770
Package Size(WxDxH)(mm) 1200x900x1980
Low Temperature Formaldehyde Steam Sterilizer Features:
  • Loading method: A movable stainless steel basket with support rods to avoid stacking items.
  • Control system: Adopting Siemens PLC control system and friendly human-machine interaction interface, safe and reliable; One click start to finish, the entire process is automatically completed, displaying information such as temperature, pressure, sterilization time, etc. The system can be maintained and upgraded.
  • Heating system: PID temperature controller is used to control the door, inner tank, and steam generator respectively and ensure their working stability.
  • Display function: It can display temperature, pressure, time, operating mode, and alarm information.
  • Power outage memory function: reduces operating costs and risk of misoperation.
  • Steam generator: A self-developed fast evaporator that not only improves the vaporization rate of formaldehyde solution, but also enhances the sterilization effect.
  • Cleaning and drying function: With the independent addition of automatic cleaning and drying function, it greatly reduces the formaldehyde residue in the processed items while ensuring the basic requirement of not getting wet, ensuring that it is below the national standard value.
  • Automatic dosing function: Unique formaldehyde solution soft bag filling technology, automatic puncture filling, to avoid manual risks.
  • Printing function: capable of printing program name, sterilization date, sterilization pot number, sterilization start and end time, as well as pressure, temperature, stage time and other information of each stage of the sterilization process. Printing records should be kept for more than 5 years.
  • Storage function: Store sterilization data for no less than 15000 cycles, including program name, sterilization date, sterilization cycles, sterilization start and end time, as well as pressure, temperature, stage time, and end status of each stage of the sterilization process.
  • Alarm system: There is a high temperature alarm system.
  • Network connection: Equipped with a network connection port.
  • Vacuum pump: Adopting a German water ring vacuum pump with reliable quality, it not only meets the design pressure requirements of the sterilizer, but also accelerates the decomposition and absorption of formaldehyde vapor to a certain extent, with a higher safety factor.
  • Air filter: filtration accuracy ≤ 0.22 μ M;
  • Pressure sensor: The built-in pressure sensor uses high-precision sensors to automatically detect the pressure inside the cavity, ensuring that the accuracy of the pressure inside the cavity is controlled within an effective range.
  • Temperature sensor: embedded temperature sensor automatically detects the temperature inside the cavity, ensuring that the accuracy of the temperature inside the cavity is controlled within an effective range.
  • Multiple protection functions: equipped with multiple protection functions such as overvoltage, undervoltage, overtemperature, door failure, and door safety interlock device
DrGem Ceiling Mounted Digital X-ray is a diagnostic digital radiography system that provides reliable high quality digital radiographic images with a reduced dose. The GXR-SD DR systems offer comprehensive digital solutions to all radiography needs, featuring ACQUIDR digital imaging system with stationary or portable digital flat-panel detectors as well as reliable high-frequency x-ray generators that are known worldwide for their excellent performance, lifetime and stability. Patient tables and wall stands are also offered. Features:
  • TS-CSA-A (Vertical movement, 1.6m stroke, rail length 3x4meter) including HV cable 15m
  • WBS-TA: Vertical movement
  1. V Stroke:1,450mm in Uprigh Bucky Position,
  2. 1,526mm in Horizontal Bucky position.
  • PBT-4 is a 4 way Floating Tabletop. A large tabletop with extended travel enables all radiography studies with minimal patient movement. Fully fat tabletop without a frame on the edge makes cleanliness and odors free
  • Digital Flat Panel Detector (FPD) – Wireless 17X14 (Csl, 4336W) with Auto Exposure Detection (AED) function, there is no DR trigger cable between detector and generator.
  • Full Featured Imaging Software & Excellent Digital Image Processing:
  1. Provides convenient user interface and easy operation
  2. Anatomical view-based digital image processing automatically optimizes and enhances the quality of the captured image for the pictured anatomy.
  3. Radiographic stand & automatic collimator control function
  4. DICOM 3.0 networking interface includes Worklist, Print, Store, Query for integration with any PACS or RIS
  • Included – Software, HP Laptop Computer
  1. CPU≥3.2GHz
  2. Memory capacity:≥4GB
  3. Hard drive capacity :≥500 GB
  4. Resolution: 1280 x 1024
  5. Display size: 21 inch color LCD screen
  6. 64 bit Windows 10 operation system
  7. Core: i5
  Technical Specification:
  • Power Rating - 32KW
  • Generator - GXR-32S
  • Rotor - Dual Speed Starter(DSS)
  • Input Power - 400/480VAC, Three phase
  • Line Frequency - 50/60Hz
  • X-ray tube - DXT-12M, (0.6/1.2mm, 300kHU)
  • Tube Voltage - 40 to 150kV, 1kV Step
  • Tube Current – 10 to 640mA
  • Output - 640mA@81kV,  500mA@104kV, 400mA@130kV, 320mA@150kV
  • Time Range - 1ms to 10s
  • mAs Range - 0.1 to 800mAs
  • Reproducibility - Coe­cient of Variation : kV < 0.005, Time < 0.005,mAs < 0.01
  • Accuracy - kV < ±(1%+1kV), mA < ±(3%+1mA), Time <±(1%+0.5ms), mAs < ±(3%+0.1mAs)
  • Linearity - Coe­cient of Linearity < 0.01 : CL = (X1-X2)/(X1+X2), where X is mR/mAs
  • Mechanical Parts:
-TS-CSA-A (Vertical movement, 1.6m, stroke rail length 3x4meter) including HV cable 15m - PBT-4: 4 way Floating Tabletop. - WBS-TA: a. Vertical    movement
  1. V Stroke:1,450mm in Upright Bucky
  2. Position, 1,526mm in Horizontal Bucky position.
- HVC-15: 15M HV cable - Auto Collimator  
Click Here To Download Catalogue
Electrocardiograph AsCARD Grey v.07.225 - is a 1, 3, 6, 12 channel ECG unit which enables to make electrocardiogram in full 12 leads. It is intended to conduct ECG examinations of adults and paediatric patients in all types of health care centres. ECG examination may be recorded in manual or automatic mode, with the possibility of analysis and interpretation. The device can be powered from 100 V ÷ 240 V mains supply or by an internal battery. Technical Specification:1. Visualisation of 1, 3, 6 or 12 ECG waveforms, analysis results and interpretations, examinations stored in memory. 2. Recording of 12 standard leads. 3. Print out in 1, 3, 6 or 12 ECG waveforms mode. Printing of a selected group:
  • 1 channel - (I, II, III, aVR, aVL, aVF, V1, V2, V3, V4, V5, V6),
  • 3 channels in standard format - (I-II-III, aVR-aVL-aVF, V1-V2-V3, V4-V5-V6),
  • 3 channels in Cabrera format - (aVL-I-aVR, II-aVF-III, V1-V2-V3, V4-V5-V6),
  • 6 channels in standard format - (I-II-III-aVR-aVL-aVF, V1-V2-V3-V4-V5-V6),
  • 6 channels in Cabrera format - (aVL-I-aVR-II-aVF-III, V1-V2-V3-V4-V5-V6),
  • 12 channels in standard format - (I-II-III-aVR-aVL-aVF-V1-V2-V3-V4-V5-V6),
  • 12 channels in Cabrera format - (aVL-I-aVR-II-aVF-III-V1-V2-V3-V4-V5-V6).
4. Available types of examinations: manual, AUTO, SPIRO, automatic to clipboard, AUTOMANUAL, LONG (v.07.xx5). 5. Automatic record ECG signal from all 12 leads simultaneously, with save to temporary memory function, then depending on the settings: print out examination's result, analysis, interpretation or save to database. 6. Adjustable length of automatic examination recording — interval of 6–30 seconds. 7. Reverse recording in automatic examination to clipboard and in manual examination (v.07.xx5). 8. Rhythm print out in AUTO examination and automatic examination to clipboard. 9. Definable stages of examination according to set up parameters in AUTOMANUAL examination. 10. Storing an examination in memory, 1–15 minutes in LONG mode (v.07.xx5). 11. ECG printed directly from the electrocardiograph using PCL5/6 printer. 12. Printout from database. Possibility to printout additional information about examination or patient. 13. Alpha-numerical soft-key keyboard with functional buttons. 14. Possibility to set parameters: speed, sensitive, intensity of printing. 15. Menu displayed on the screen for easy operation using touch panel. 16. Database of patients and examinations. Internal memory up to 1000 patients, 1000 examinations. 17. Viewing of the memory-stored examinations on display, with the possibility of changing the number of leads, augmentation and speed. 18. Automatic analysis and interpretation in compliance with EN 60601-2-51 (CSE database) - Analysis and interpretation dependable on age & sex of a patient. 19. Up to 130 automatic examinations in battery mode. 20. Continuous heart rate (HR) measurement and display. 21. Adapted to direct operation on an open heart. 22. Device allows to enable and disable the following filters:
  • power line interference filter; filters available: 50 Hz, 60 Hz,
  • muscle interference filter; filters available: 25 Hz, 35 Hz, 45 Hz,
  • contour line filters; filters available: 0.15 Hz, 0.45 Hz, 0.75 Hz, 1.5 Hz,
  • the low-pass filter (v.07.224, v.07.324, v.07.225, v.07.325): 75 Hz, 100 Hz, 125 Hz, 150 Hz,
  • the auto-adaptive filter (v.07.224, v.07.324, v.07.225, v.07.325).
23. Detection of electrode detachment, independent for each channel (INOP control). 24. Detection of cardiac stimulator. 25. Sound signalling of detected stimulations of heart stimulator. 26. Protection against defibrillation pulse. 27. ECG recordings optionally saved on PenDrive, send on email or to other AsCARD via EKG-MAIL. 28. Wireless communication with the LAN or the Internet (v.07.3xx). 29. Wired communication with the LAN or the Internet. 30. Cooperation with CardioTEKA and CardioTEL. 31. Possibility of accepting orders for examination and sending back the results in HL7 standard via Internet (v.07.3xx). 32. Possibility of conducting preliminary spirometry examinations by using SPIRO-31 attachment. 33. EMR – keep performed examinations in specified period of time on external data storage (USB memory). Accessories 1. Limb electrodes, 4 pieces (EKK type). 2. Chest electrodes, 6 pieces (EPP type). 3. KEKG 30R ECG cable. 4. Main cable. 5. R-A4 paper, 112 mm wide (1 reel). 6. ECG gel. 7. Operation manual.  
Click Here To Download Catalogue
Ergometer CRG 200 is dedicated for Exercise Stress Tests System CardioTEST. The Ergometer has been designed according to modern technologies. It is controlled from PC equipped in CardioTEST software. Load level is controlled by a microprocessor, therefore it does not depend on speed, which in turn can be adjusted according to patient’s individual needs. Ergometer is equipped with ECG mode recording 12 standard leads. Technical Specifications:
  • Cooperation with the CardioTEST cardiovascular exercise system and AsTER cardiac rehabilitation system,
  • Control using a computer through the RS-232 port,
  • Braking: a processor-controlled brake with torque measurement,
  • Load range: 25 - 1000 W,
  • Speed ​​range: 20 - 150 rpm,
  • Load independent of the number of turns,
  • Built-in ECG module,
  • 12 standard leads in diagnostic mode,
  • 2 leads in training mode,
  • Sensitivity 2,5 / 5/10/20 mm / mV,
  • Shift 25/50/100 mm / s,
  • Digital filters 25 Hz, 35 Hz, 50 Hz, anti-frit filter,
  • Digital filter of the isoelectric line,
  • Measuring range HR 15-240 bpm,
  • Maximum patient weight 200 kg,
  • Power supply: 230 V, 50 Hz, 60VA,
  • Dimensions: (LxWxH) 1190x600x1370 mm.
CardioTEST Software:
  • excellent quality of ECG waveforms thanks to the use of digital filters eliminating the swimming of the isoelectric line and disruption of muscle origin,
  • uninterrupted recording and presentation of 12-lead ECG signal,
  • presentation of averaged P-QRS-T units with 12 leads along with the results of ST level and slope measurements,
  • automatic HR measurement, ST level and ST segment slope,
  • automatic control of cycloergometer and treadmill load,
  • archiving and printing of the research report,
  • automatic determination of measuring points with the possibility of manual correction,
  • automatic arrhythmia analysis,
  • presentation of parameters regarding: test phase, current load, stage time and total effort time,
  • monitored parameters: rhythm rate, MET, double product, blood pressure, level, ST segment slope and load,
  • real-time ECG printout,
  • preview of trends of all measured parameters during the test,
  • alarm system for monitored parameters and arrhythmia,
  • an option to automatically measure blood pressure,
  • archiving and printing a report enabling a reliable assessment of the study (such an report contains ECG, average P-QRS-T assemblies and a table with measurement results),
  • standard test protocols and the ability to define your own protocols also in RAMP mode,
  • preview the report on the screen before printing the report,
  • function of reanalysis of the performed test,
  • presentation of 3D trends illustrating ST segment changes.
 
Click Here To Download Catalogue 
Bistos BT-770 is a 12.1" touchscreen patient monitor designed for easy operations. SPECIFICATIONS
  • 12.1“ color TFT touch screen
  • ECG, Resp., SpO2, NIBP, Temp., CO2, IBP, Multi-gas, C.O., Masimo SpO2
  • Precise ECG measurement with pacemaker detection ST segment and 16 types of arrhythmia analysis Double overpressure protection for NIBP Intelligent cuff inflation pressure adjustment
  • Smart Hook/Stand design, provide multiple placement modes Plug & Play Modular IBP& C.O., Modular Printer Multiple configuration options: 4-channel IBP, CO2, invasive C.O., Multi-gas Over 5 hours continuous working on battery 12-15V wide range DC input, suitable for ambulance Capable to connect with central monitoring system HL7 export to clinical information systems (option)
 
Click Here To Download Catalogue
DrGem GXR-SD 400mA Floor Mounted Digital X-ray system matches with a radiographic room which perfectly fits your workow and can be easily upgraded to DR system with the help of DR interface and PC interface in GXR generator as well as Bucky suitable to Flat Panel Detector. GXR X-ray system is equipped with a high frequency X-ray generator which consistently produces high quality radiograph in favor of high quality X-ray output with a very small kV ripple and accurate mA and mAs. GXR X-ray system is designed to provide convenience to operator and comfort to patient Features of DrGem GXR-SD 400mA Floor Mounted Digital X-ray:
  • PBT-6 is a 4 way Motorized Tabletop with Elevating feature (66cm). A large tabletop with extended travel enables all radiography studies with minimal patient movement. Fully fat tabletop without a frame on the edge makes cleanliness and odors free
  • Automatic Stitching - GXR-SD system provides outstanding automatic stitching function with Source tilting method
  • Digital Flat Panel Detector (FPD) – Wireless 17X14 (Csl, 4336W) with Auto Exposure Detection (AED) function, there is no DR trigger cable between detector and generator.
  • Full Featured Imaging Software & Excellent Digital Image Processing:
  1. Provides convenient user interface and easy operation
  2. Anatomical view-based digital image processing automatically optimizes and enhances the quality of the captured image for the pictured anatomy.
  3. Radiographic stand & automatic collimator control function
  4. DICOM 3.0 networking interface includes Worklist, Print, Store, Query for integration with any PACS or RIS
  • Included – Software, HP Laptop Computer
  1. CPU≥3.2GHz
  2. Memory capacity:≥4GB
  3. Hard drive capacity :≥500 GB
  4. Resolution: 1280 x 1024
  5. Display size: 21 inch color LCD screen
  6. 64 bit Windows 10 operation system
  7. Core: i5
  Technical Specifications of DrGem GXR-SD 400mA Floor Mounted Digital X-ray:
  • Power Rating - 32KW
  • Generator - GXR-32S
  • Rotor - Dual Speed Starter(DSS)
  • Input Power - 400/480VAC, Three phase
  • Line Frequency - 50/60Hz
  • X-ray tube - DXT-12M, (0.6/1.2mm, 300kHU)
  • Tube Voltage - 40 to 150kV, 1kV Step
  • Tube Current – 10 to 640mA
  • Output - 640mA@81kV,  500mA@104kV, 400mA@130kV, 320mA@150kV
  • Time Range - 1ms to 10s
  • mAs Range - 0.1 to 800mAs
  • Reproducibility - Coe­cient of Variation : kV < 0.005, Time < 0.005,mAs < 0.01
  • Accuracy - kV < ±(1%+1kV), mA < ±(3%+1mA), Time <±(1%+0.5ms), mAs < ±(3%+0.1mAs)
  • Linearity - Coe­cient of Linearity < 0.01 : CL = (X1-X2)/(X1+X2), where X is mR/mAs
 
Click Here To Download Catalogue
WeightN/AN/AN/AN/AN/AN/A
DimensionsN/AN/AN/AN/AN/AN/A
Additional information
Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • Rating
  • Price
  • Description
Click outside to hide the comparison bar