It is an instrument for detecting DNA, RNA, and protein concentration. A sample volume of 0.5 to 2 μl is required for each measurement, allowing fast, accurate and reproducible micro-measurements without dilution. Accessories such as cuvettes or capillaries are not required. At the end of the measurement, you can wipe off the sample directly or use a pipette to retrieve it. The procedure is quick and easy. It can also detect the concentration of OD600 bacteria/microorganisms and other culture fluids.

Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
SF1033560130127-35
Brands:: Scitek

Description

Microvolume UV Vis Spectrophotometer Features:

UV vis spectrophotometer is an instrument for detecting DNA, RNA, and protein concentration. A sample volume of 0.5 to 2 μl is required for each measurement, allowing fast, accurate and reproducible micro-measurements without dilution. Accessories such as cuvettes or capillaries are not required. At the end of the measurement, you can wipe off the sample directly or use a pipette to retrieve it. The procedure is quick and easy. It can also detect the concentration of OD600 bacteria/microorganisms and other culture fluids.

1. Can test 7-inch high-definition capacitive touch screen, stand-alone

2. Long-life LED light source assembly, mainly used for detecting nucleic acid concentration and purity.

3. Extremely fast testing speed. Samples can be tested at any time.

4. Long-life optical components, intelligent light source control system, no need to preheat.

5. Can store 100,000 data in each sub-catalog.

6. Detection limit as low as 0.5pg/μL in fluorometer mode (SP-MUV2000I only).

Advantages
  1. Can test 7-inch high-definition capacitive touch screen, stand-alone
  2. Long-life LED light source assembly, mainly used for detecting nucleic acid concentration and purity.
  3. Extremely fast testing speed. Samples can be tested at any time.
  4. Long-life optical components, intelligent light source control system, no need to preheat.
  5. Can store 100,000 data in each sub-catalog.
  6. Detection limit as low as 0.5pg/μL in fluorometer mode (SP-MUV2000I only).

 

Microvolume Spectrophotometer Specifications:
Model SP-MUV2000 SP-MUV2000I
Wavelength Range Fixed wavelength: 260nm, 280nm Fixed wavelength: 260nm, 280nm
Sample Capacity 0.5-2 μL 0.5-2 μL
Optical Path 0.2nm, 1.0mm 0. 2nm, 1.0mm
Light Source/Life UV LED/8000h UV LED/8000h
Detector UV silicon photocell UV silicon photocell
Spectral Bandwidth 8nm 8nm
Absorbance Precision 0.005Abs 0.005Abs
Accuracy ±5ng or 2% ±5ng or 2%
Range 0.2-100 (Equivalent to 10mn optical path) 0.2-100 (Equivalent to 10mn optical path)
Nucleic Acid Concentration Range 2-15000ng/μL dsDNA 2-15000ng/μL dsDNA
Detection Time 5 s 5 s
OD600 Absorbance Range 0-4.000Abs 0-4.000Abs
Absorbance Stability [0, 3)≤ 0.5%, [3,4)≤ 1% [0, 3)≤ 0.5%, [3,4)≤ 1%
Absorbance Repeatability [0, 3)≤ 0.5%, [3,4)≤ 1% [0, 3)≤ 0.5%, [3,4)≤ 1%
Absorbance Accuracy [0, 3)≤ 0.005A+1%, [3,4)≤ 2% [0, 3) ≤0.005A+1%, [3,4)≤ 2%
Fluorescence Detection / Excitation wavelength: 460n

Emission wavelength: 525nm

Fluorescence Linearity / R2>0.995
Detection Repeatability / <1.5%
Stability / <1.5%
Print Built-in thermal printer Built-in thermal printer
Data Output Method USB USB
Material of Sample Base Quartz optical fiber and high hard aluminum Quartz optical fiber and high hard aluminum
Input Voltage VAC100-240V: VDC24V 2A VAC100-240V: VDC24V 2A
Power <15W (Standby: 5W) <15W (Standby: 5W)
Size(W×D×H)(mm) 290x208x180
Shipping Size(W×D×H)(mm) 500x430x290
N.W./G.W. (kg) 2.8/4.5

Reviews

There are no reviews yet.

Be the first to review “Microvolume UV Vis Spectrophotometer”

Your email address will not be published. Required fields are marked *

Quick Comparison

Microvolume UV Vis Spectrophotometer removeSkyla Hi POC Clinical Chemistry Analyzer removeNikon SMZ745 Stereoscopic Microscope removeiSED Fully Automated ESR Analyzer removeDiscover 14 Panel Cup with Adulterants Per Pack removeSkyla HB1 POC Clinical Chemistry Auto Analyzer remove
NameMicrovolume UV Vis Spectrophotometer removeSkyla Hi POC Clinical Chemistry Analyzer removeNikon SMZ745 Stereoscopic Microscope removeiSED Fully Automated ESR Analyzer removeDiscover 14 Panel Cup with Adulterants Per Pack removeSkyla HB1 POC Clinical Chemistry Auto Analyzer remove
ImageNikon SMZ745 Stereoscopic MicroscopeDrug Test Cup
SKUSF1033560130127-35SF1033560060-2SF1033560084-49SF1033560084-129SF1033560084-28SF1033560060-1
Rating
Price

Ask for Price$0.00

Ask for Price$0.00

Ask for Price$0.00

Ask for Price$0.00

Ask for Price$0.00

Ask for Price$0.00

Stock
Availability
Add to cart

DescriptionShipped From Abroad It is an instrument for detecting DNA, RNA, and protein concentration. A sample volume of 0.5 to 2 μl is required for each measurement, allowing fast, accurate and reproducible micro-measurements without dilution. Accessories such as cuvettes or capillaries are not required. At the end of the measurement, you can wipe off the sample directly or use a pipette to retrieve it. The procedure is quick and easy. It can also detect the concentration of OD600 bacteria/microorganisms and other culture fluids.
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped from Abroad The skyla Hi POC Clinical Chemistry Analyzer provides clinical testing laboratories of medical facilities and clinics with an in-vitro clinical chemistry diagnostic tool that is compact, portable, and reports rapid results.The use of skyla Hi in the management of diabetes enables better access to testing and rapid clinical decision making, discussion,and implementation of optimized treatment. Delivery & Availability: Typically 14 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.In stock Nikon SMZ745 Stereoscopic Microscope: Featuring a zoom magnification of 7.5X and a long working distance of 115mm, Nikon SMZ745 microscopes are well suited for both industrial and biomedical applications. The adoption of a new total reflection prism produces brighter images with higher contrast, and the anti-mold design allows the microscope to be used in environments where the temperature and humidity are high. The SMZ-745T trinocular model comes equipped with a microscope camera port and a built-in 0.55x c-mount adapter, permitting direct mounting of Nikon DS Series Digital Cameras. Delivery & Availability: Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.In stock
The technical innovation of the iSED® fully-automated ESR analyzer consists of directly measuring the intensity of the red cell aggregation which is responsible for Erythrocyte Sedimentation Rate (ESR). Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock
The Discover Cup is an all-in-one drug of abuse test cup. The strips are self contained and the entire cup is tamper resistant. Delivery & Availability:
Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped from Abroad The skyla HB1 Clinical Chemistry Analyzer provides clinical testing laboratories of medical facilities and clinics with an in-vitro clinical chemistry diagnostic tool that is compact, portable, and reports rapid results. The portable design of the clinical chemistry analyzer utilizes precision photometric measurement technology, combined with the single-use disposable reagent discs. The reagent disc contains a set of dry assay reagents that are used in the quantitative testing of various biomarkers in the blood sample. Delivery & Availability: Typically 14 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Content
Microvolume UV Vis Spectrophotometer Features:
UV vis spectrophotometer is an instrument for detecting DNA, RNA, and protein concentration. A sample volume of 0.5 to 2 μl is required for each measurement, allowing fast, accurate and reproducible micro-measurements without dilution. Accessories such as cuvettes or capillaries are not required. At the end of the measurement, you can wipe off the sample directly or use a pipette to retrieve it. The procedure is quick and easy. It can also detect the concentration of OD600 bacteria/microorganisms and other culture fluids. 1. Can test 7-inch high-definition capacitive touch screen, stand-alone 2. Long-life LED light source assembly, mainly used for detecting nucleic acid concentration and purity. 3. Extremely fast testing speed. Samples can be tested at any time. 4. Long-life optical components, intelligent light source control system, no need to preheat. 5. Can store 100,000 data in each sub-catalog. 6. Detection limit as low as 0.5pg/μL in fluorometer mode (SP-MUV2000I only).
Advantages
  1. Can test 7-inch high-definition capacitive touch screen, stand-alone
  2. Long-life LED light source assembly, mainly used for detecting nucleic acid concentration and purity.
  3. Extremely fast testing speed. Samples can be tested at any time.
  4. Long-life optical components, intelligent light source control system, no need to preheat.
  5. Can store 100,000 data in each sub-catalog.
  6. Detection limit as low as 0.5pg/μL in fluorometer mode (SP-MUV2000I only).
 
Microvolume Spectrophotometer Specifications:
Model SP-MUV2000 SP-MUV2000I
Wavelength Range Fixed wavelength: 260nm, 280nm Fixed wavelength: 260nm, 280nm
Sample Capacity 0.5-2 μL 0.5-2 μL
Optical Path 0.2nm, 1.0mm 0. 2nm, 1.0mm
Light Source/Life UV LED/8000h UV LED/8000h
Detector UV silicon photocell UV silicon photocell
Spectral Bandwidth 8nm 8nm
Absorbance Precision 0.005Abs 0.005Abs
Accuracy ±5ng or 2% ±5ng or 2%
Range 0.2-100 (Equivalent to 10mn optical path) 0.2-100 (Equivalent to 10mn optical path)
Nucleic Acid Concentration Range 2-15000ng/μL dsDNA 2-15000ng/μL dsDNA
Detection Time 5 s 5 s
OD600 Absorbance Range 0-4.000Abs 0-4.000Abs
Absorbance Stability [0, 3)≤ 0.5%, [3,4)≤ 1% [0, 3)≤ 0.5%, [3,4)≤ 1%
Absorbance Repeatability [0, 3)≤ 0.5%, [3,4)≤ 1% [0, 3)≤ 0.5%, [3,4)≤ 1%
Absorbance Accuracy [0, 3)≤ 0.005A+1%, [3,4)≤ 2% [0, 3) ≤0.005A+1%, [3,4)≤ 2%
Fluorescence Detection / Excitation wavelength: 460n Emission wavelength: 525nm
Fluorescence Linearity / R2>0.995
Detection Repeatability / <1.5%
Stability / <1.5%
Print Built-in thermal printer Built-in thermal printer
Data Output Method USB USB
Material of Sample Base Quartz optical fiber and high hard aluminum Quartz optical fiber and high hard aluminum
Input Voltage VAC100-240V: VDC24V 2A VAC100-240V: VDC24V 2A
Power <15W (Standby: 5W) <15W (Standby: 5W)
Size(W×D×H)(mm) 290x208x180
Shipping Size(W×D×H)(mm) 500x430x290
N.W./G.W. (kg) 2.8/4.5

skyla Hi Analyzer enables better access to testing and rapid clinical decision making, discussion, and implementation of optimized treatment. To get the result, only prepare <1 μl fingertips blood or venous blood (depends on test item) without pretreatment with easy steps and then read the result after 6 mins. The device allows two specimens be tested in one run and provides fully automatic procedures from checking the validity of cartridge to printing the results. Reagent Kit
  • HbA1C
  • CRP
  • Lipid Panel (TC,TG, HDL, LDL#)
  • Lipid Plus Panel (Glu,TC,TG, HDL, LDL#)
Main Specification
Principle
Turbidimetric Method / Biochemistry
Device
Testing Time
5~20 minutes (depends on test items)
Display and Interface
5″ TFT color touch screen LCD
Memory Capacity
50,000 test results
Dimension of Analyzer
270 x 188 x 148 mm
Weight of Analyzer
1.7 kg
Dimension of Printer Module
134 x 100 x 82.7 mm
Weight of Printer Module
0.37 kg
Power Supply
100~240 volts AC, 50-60Hz
Data Transmission
USB 2.0*4 / USB 3.0*1 / RS232*1 / RJ45*1 / Wi-Fi (optional)
Reagent and Samples
Samples
Fingertips blood or venous blood
Samples Volume
0.8 ~ 30 μL (depends on test item)
Storage Temperature (Reagent)
2 ~ 8˚C
Humidity
Relative humidity < 95% (Non-condensing)
Temperature
10 ~ 32 ˚C
Click Here To Download Catalogue
Nikon SMZ745 Stereoscopic Microscope: Featuring a zoom magnification of 7.5X and a long working distance of 115mm, Nikon SMZ745 microscopes are well suited for both industrial and biomedical applications. The adoption of a new total reflection prism produces brighter images with higher contrast, and the anti-mold design allows the microscope to be used in environments where the temperature and humidity are high. The SMZ-745 trinocular model comes equipped with a microscope camera port and a built-in 0.55x c-mount adapter, permitting direct mounting of Nikon DS Series Digital Cameras. Features:
  • Trinocular optical head for monitoring and digital imaging
  • Impressive 7.5x zoom magnification
  • 115 mm working distance
  • Maximum ergonomics
  • Rugged, durable design suits a variety of applications and environments
Technical Specifications:
Optical system Greenough optical system
Total magnification 3.35-300x, depending on eyepiece and auxiliary objective used
Vertical tube Built-in C-mount 0.55x magnification lens (F.N. 11), compatible with 2/3 in. or smaller CCD
Eyepiece tube Fixed type
Eyepiece inclination 45°
Interpupillary distance adjustment 52-75 mm
Eyepieces (with diopter adjustment) C-W 10xB (F.N. 22), C-W 15x (F.N. 16), C-W 20x (F.N. 12.5), C-W 30x (F.N. 7)
Zooming ratio 7.5:1 (approx.)
Zooming range 0.67-5x
Auxiliary objectives G-AL 0.5x (W.D. 211 mm), G-AL 0.7x (W.D. 150 mm), G-AL 1.5x (W.D. 61 mm), G-AL 2x (W.D. 43.5 mm)
Working distance 115 mm
     
 
 
The technical innovation of the iSED® fully-automated ESR analyzer consists of directly measuring the intensity of the red cell aggregation which is responsible for Erythrocyte Sedimentation Rate (ESR). Unlike traditional ESR methodologies that measure the aggregation of the red blood cells indirectly, the iSED measures it directly and expresses the values in mm/hr. Features:
  • Results in 20 Seconds

  • 100µL sample drawn directly from primary EDTA tube

  • Fully automated, walk-away operation

  • Random access

  • Positive patient identification via internal barcode reader

  • Compatible with pediatric tube

     
Technical Specifications: 
Principle of Measure: Photometrical
Results: “Printed mm/hr, Range from 1-130 mm/hr”
Sample Requirements: 500uL whole blood, collected in EDTA anti-coagulant tested 24 hours from venipuncture at room temperature or refrigerated.
Tube Requirements: 13 x 75 mm, pierceable capped tube
Quality Control: Barcoded Seditrol® QC
Barcode Reader: Internal
Printer: Internal
Interface Specifications: serial RS232 port for LIS connection
Weight: 14 kg
Dimensions (H x W x D): 36 x 27 x 34 (cm) /14.3 x 10.5 x13.4 (in)
Voltage: 100-240VAC
Frequency Range: 50-60 Hz
Power: 160W
Click Here To Download Catalogue
All-in-One Design
FDA 510(K) & CLIA Waived Up to 99% accuracy rate Results in as little as 1 minute 24 Month Shelf Life from Date of Manufacture Secure, seal and send to lab for confirmation Built in temperature strip Available to test up to 17 substances with adulterants or 18 without adulterants Adulterants available
 
 
Skyla HB1 Clinical Chemistry Analyzer utilizes precision photometric measurement technology, combined with the single-use disposable reagent discs. The reagent disc contains a set of dry assay reagents that are used in the quantitative testing of various biomarkers in the blood sample. HB1 provides clinical testing laboratories of medical facilities and clinics with an in-vitro clinical chemistry diagnostic tool that is compact, portable, and reports rapid results. Only needs 200µl of blood (whole blood, serum or plasma is accepted.) and no sample preparation is required. All steps are designed automatically from checking the validity of reagent discs and cartridges to printing the results. Over 30 test parameters are allowed with fast analysis and results in 15 minutes. Internal Quality Control (IQC) with self-calibration of optical system, chemicals stability and interference alerts functions monitor and ensure the results with high accuracy. Available Test Panels
  • Renal Function - BUN, CREA eGFR
  • Liver Function - ALB, TP, ALP, ALT, AST, TBIL, DBIL, GGT, LDH A/G#, GLOB#, IBIL
  • Lipid Metabolism - TG, TC, HDL LDL#, VLDL
  • Pancreatitis Markers - AMY, LIPA
  • Carbohydrate Metabolism and Others - GLU , CPK, UA, LAC
  • Inflammatory Markers - CRP
  • Electrolyte - Na, K, Cl, Ca, PHOS, Mg, tCO2
SPECIFICATION Principle
  • Colormetric System : LEDs 340nm~940nm wavelength
Sample & Panel
  • Test Profiles : Panels
  • Measurement Time - Panel: up to 15 tests/ 15 min
  • Sample Type & Volume : 200 μl whole blood (PCV<60%), plasma, serum 
Device
  • User Interface : 5 inch color LCD touch screen
  • Internal Memory : Store up to 50,000 analysis results
  • Printer : Built in thermal printer or external USB printer (PCL 3GUI)
  • USB Socket : USB type A (Host) for external USB Printer, USB flash drive (FAT) or external barcode scanner
  • Data transmission to PC : RS232 serial port or RJ45 (LAN)
  • Dimensions : 233 (W) X 285 (D) X 300 (H) mm
  • Weight : 5.5 kg
Operating Condition
  • Temperature / Humidity : 10 to 32˚C / 5 to 90 %
 
Click Here To Download Catalogue