Microvolume UV Vis Spectrophotometer

$0.00

Shipped From Abroad

It is an instrument for detecting DNA, RNA, and protein concentration. A sample volume of 0.5 to 2 μl is required for each measurement, allowing fast, accurate and reproducible micro-measurements without dilution. Accessories such as cuvettes or capillaries are not required. At the end of the measurement, you can wipe off the sample directly or use a pipette to retrieve it. The procedure is quick and easy. It can also detect the concentration of OD600 bacteria/microorganisms and other culture fluids.

Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
SF1033560130127-35
Brands:: Scitek

Description

Microvolume UV Vis Spectrophotometer Features:

UV vis spectrophotometer is an instrument for detecting DNA, RNA, and protein concentration. A sample volume of 0.5 to 2 μl is required for each measurement, allowing fast, accurate and reproducible micro-measurements without dilution. Accessories such as cuvettes or capillaries are not required. At the end of the measurement, you can wipe off the sample directly or use a pipette to retrieve it. The procedure is quick and easy. It can also detect the concentration of OD600 bacteria/microorganisms and other culture fluids.

1. Can test 7-inch high-definition capacitive touch screen, stand-alone

2. Long-life LED light source assembly, mainly used for detecting nucleic acid concentration and purity.

3. Extremely fast testing speed. Samples can be tested at any time.

4. Long-life optical components, intelligent light source control system, no need to preheat.

5. Can store 100,000 data in each sub-catalog.

6. Detection limit as low as 0.5pg/μL in fluorometer mode (SP-MUV2000I only).

Advantages
  1. Can test 7-inch high-definition capacitive touch screen, stand-alone
  2. Long-life LED light source assembly, mainly used for detecting nucleic acid concentration and purity.
  3. Extremely fast testing speed. Samples can be tested at any time.
  4. Long-life optical components, intelligent light source control system, no need to preheat.
  5. Can store 100,000 data in each sub-catalog.
  6. Detection limit as low as 0.5pg/μL in fluorometer mode (SP-MUV2000I only).

 

Microvolume Spectrophotometer Specifications:
Model SP-MUV2000 SP-MUV2000I
Wavelength Range Fixed wavelength: 260nm, 280nm Fixed wavelength: 260nm, 280nm
Sample Capacity 0.5-2 μL 0.5-2 μL
Optical Path 0.2nm, 1.0mm 0. 2nm, 1.0mm
Light Source/Life UV LED/8000h UV LED/8000h
Detector UV silicon photocell UV silicon photocell
Spectral Bandwidth 8nm 8nm
Absorbance Precision 0.005Abs 0.005Abs
Accuracy ±5ng or 2% ±5ng or 2%
Range 0.2-100 (Equivalent to 10mn optical path) 0.2-100 (Equivalent to 10mn optical path)
Nucleic Acid Concentration Range 2-15000ng/μL dsDNA 2-15000ng/μL dsDNA
Detection Time 5 s 5 s
OD600 Absorbance Range 0-4.000Abs 0-4.000Abs
Absorbance Stability [0, 3)≤ 0.5%, [3,4)≤ 1% [0, 3)≤ 0.5%, [3,4)≤ 1%
Absorbance Repeatability [0, 3)≤ 0.5%, [3,4)≤ 1% [0, 3)≤ 0.5%, [3,4)≤ 1%
Absorbance Accuracy [0, 3)≤ 0.005A+1%, [3,4)≤ 2% [0, 3) ≤0.005A+1%, [3,4)≤ 2%
Fluorescence Detection / Excitation wavelength: 460n

Emission wavelength: 525nm

Fluorescence Linearity / R2>0.995
Detection Repeatability / <1.5%
Stability / <1.5%
Print Built-in thermal printer Built-in thermal printer
Data Output Method USB USB
Material of Sample Base Quartz optical fiber and high hard aluminum Quartz optical fiber and high hard aluminum
Input Voltage VAC100-240V: VDC24V 2A VAC100-240V: VDC24V 2A
Power <15W (Standby: 5W) <15W (Standby: 5W)
Size(W×D×H)(mm) 290x208x180
Shipping Size(W×D×H)(mm) 500x430x290
N.W./G.W. (kg) 2.8/4.5

Reviews

There are no reviews yet.

Be the first to review “Microvolume UV Vis Spectrophotometer”

Your email address will not be published. Required fields are marked *

Quick Comparison

SettingsMicrovolume UV Vis Spectrophotometer removeSkyla HB1 POC Clinical Chemistry Auto Analyzer removeAutomatic Pipette removeAvalun LabPad Device removeiSED Fully Automated ESR Analyzer remove8 Bucket Centrifuge remove
NameMicrovolume UV Vis Spectrophotometer removeSkyla HB1 POC Clinical Chemistry Auto Analyzer removeAutomatic Pipette removeAvalun LabPad Device removeiSED Fully Automated ESR Analyzer remove8 Bucket Centrifuge remove
ImageAvalun Labpad machine
SKUSF1033560130127-35SF1033560060-1SF1033560084-130SF1033560084-65SF1033560084-129SF1033560084-114
Rating
Price

$0.00

$0.00

$0.00

$0.00

$0.00

$72.50

Stock
Availability
Add to cart

DescriptionShipped From Abroad It is an instrument for detecting DNA, RNA, and protein concentration. A sample volume of 0.5 to 2 μl is required for each measurement, allowing fast, accurate and reproducible micro-measurements without dilution. Accessories such as cuvettes or capillaries are not required. At the end of the measurement, you can wipe off the sample directly or use a pipette to retrieve it. The procedure is quick and easy. It can also detect the concentration of OD600 bacteria/microorganisms and other culture fluids.
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped from Abroad The skyla HB1 Clinical Chemistry Analyzer provides clinical testing laboratories of medical facilities and clinics with an in-vitro clinical chemistry diagnostic tool that is compact, portable, and reports rapid results. The portable design of the clinical chemistry analyzer utilizes precision photometric measurement technology, combined with the single-use disposable reagent discs. The reagent disc contains a set of dry assay reagents that are used in the quantitative testing of various biomarkers in the blood sample. Delivery & Availability: Typically 14 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.In stock
This Automatic Pipette will help you get your lab up and running in no time—at a great price! Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock The coagulometer, LabPad® INR, measures blood coagulation time thanks to a patented optical technology. This portable In-Vitro Diagnostics (IVD) device works with the Tsmart® INR single-use microcuvettes. Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.In stock
The technical innovation of the iSED® fully-automated ESR analyzer consists of directly measuring the intensity of the red cell aggregation which is responsible for Erythrocyte Sedimentation Rate (ESR). Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock
Classification: Laboratory Centrifuge
Brand Name: xiangtian
Model Number: 800-1
Place of Origin: Jiangsu, China
Time range: 0-60min
Max speed: 4000r/min
Max RCF: 1790xg
Capacity: 20ml*6
  Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Content
Microvolume UV Vis Spectrophotometer Features:
UV vis spectrophotometer is an instrument for detecting DNA, RNA, and protein concentration. A sample volume of 0.5 to 2 μl is required for each measurement, allowing fast, accurate and reproducible micro-measurements without dilution. Accessories such as cuvettes or capillaries are not required. At the end of the measurement, you can wipe off the sample directly or use a pipette to retrieve it. The procedure is quick and easy. It can also detect the concentration of OD600 bacteria/microorganisms and other culture fluids. 1. Can test 7-inch high-definition capacitive touch screen, stand-alone 2. Long-life LED light source assembly, mainly used for detecting nucleic acid concentration and purity. 3. Extremely fast testing speed. Samples can be tested at any time. 4. Long-life optical components, intelligent light source control system, no need to preheat. 5. Can store 100,000 data in each sub-catalog. 6. Detection limit as low as 0.5pg/μL in fluorometer mode (SP-MUV2000I only).
Advantages
  1. Can test 7-inch high-definition capacitive touch screen, stand-alone
  2. Long-life LED light source assembly, mainly used for detecting nucleic acid concentration and purity.
  3. Extremely fast testing speed. Samples can be tested at any time.
  4. Long-life optical components, intelligent light source control system, no need to preheat.
  5. Can store 100,000 data in each sub-catalog.
  6. Detection limit as low as 0.5pg/μL in fluorometer mode (SP-MUV2000I only).
 
Microvolume Spectrophotometer Specifications:
Model SP-MUV2000 SP-MUV2000I
Wavelength Range Fixed wavelength: 260nm, 280nm Fixed wavelength: 260nm, 280nm
Sample Capacity 0.5-2 μL 0.5-2 μL
Optical Path 0.2nm, 1.0mm 0. 2nm, 1.0mm
Light Source/Life UV LED/8000h UV LED/8000h
Detector UV silicon photocell UV silicon photocell
Spectral Bandwidth 8nm 8nm
Absorbance Precision 0.005Abs 0.005Abs
Accuracy ±5ng or 2% ±5ng or 2%
Range 0.2-100 (Equivalent to 10mn optical path) 0.2-100 (Equivalent to 10mn optical path)
Nucleic Acid Concentration Range 2-15000ng/μL dsDNA 2-15000ng/μL dsDNA
Detection Time 5 s 5 s
OD600 Absorbance Range 0-4.000Abs 0-4.000Abs
Absorbance Stability [0, 3)≤ 0.5%, [3,4)≤ 1% [0, 3)≤ 0.5%, [3,4)≤ 1%
Absorbance Repeatability [0, 3)≤ 0.5%, [3,4)≤ 1% [0, 3)≤ 0.5%, [3,4)≤ 1%
Absorbance Accuracy [0, 3)≤ 0.005A+1%, [3,4)≤ 2% [0, 3) ≤0.005A+1%, [3,4)≤ 2%
Fluorescence Detection / Excitation wavelength: 460n Emission wavelength: 525nm
Fluorescence Linearity / R2>0.995
Detection Repeatability / <1.5%
Stability / <1.5%
Print Built-in thermal printer Built-in thermal printer
Data Output Method USB USB
Material of Sample Base Quartz optical fiber and high hard aluminum Quartz optical fiber and high hard aluminum
Input Voltage VAC100-240V: VDC24V 2A VAC100-240V: VDC24V 2A
Power <15W (Standby: 5W) <15W (Standby: 5W)
Size(W×D×H)(mm) 290x208x180
Shipping Size(W×D×H)(mm) 500x430x290
N.W./G.W. (kg) 2.8/4.5

Skyla HB1 Clinical Chemistry Analyzer utilizes precision photometric measurement technology, combined with the single-use disposable reagent discs. The reagent disc contains a set of dry assay reagents that are used in the quantitative testing of various biomarkers in the blood sample. HB1 provides clinical testing laboratories of medical facilities and clinics with an in-vitro clinical chemistry diagnostic tool that is compact, portable, and reports rapid results. Only needs 200µl of blood (whole blood, serum or plasma is accepted.) and no sample preparation is required. All steps are designed automatically from checking the validity of reagent discs and cartridges to printing the results. Over 30 test parameters are allowed with fast analysis and results in 15 minutes. Internal Quality Control (IQC) with self-calibration of optical system, chemicals stability and interference alerts functions monitor and ensure the results with high accuracy. Available Test Panels
  • Renal Function - BUN, CREA eGFR
  • Liver Function - ALB, TP, ALP, ALT, AST, TBIL, DBIL, GGT, LDH A/G#, GLOB#, IBIL
  • Lipid Metabolism - TG, TC, HDL LDL#, VLDL
  • Pancreatitis Markers - AMY, LIPA
  • Carbohydrate Metabolism and Others - GLU , CPK, UA, LAC
  • Inflammatory Markers - CRP
  • Electrolyte - Na, K, Cl, Ca, PHOS, Mg, tCO2
SPECIFICATION Principle
  • Colormetric System : LEDs 340nm~940nm wavelength
Sample & Panel
  • Test Profiles : Panels
  • Measurement Time - Panel: up to 15 tests/ 15 min
  • Sample Type & Volume : 200 μl whole blood (PCV<60%), plasma, serum 
Device
  • User Interface : 5 inch color LCD touch screen
  • Internal Memory : Store up to 50,000 analysis results
  • Printer : Built in thermal printer or external USB printer (PCL 3GUI)
  • USB Socket : USB type A (Host) for external USB Printer, USB flash drive (FAT) or external barcode scanner
  • Data transmission to PC : RS232 serial port or RJ45 (LAN)
  • Dimensions : 233 (W) X 285 (D) X 300 (H) mm
  • Weight : 5.5 kg
Operating Condition
  • Temperature / Humidity : 10 to 32˚C / 5 to 90 %
 
Click Here To Download Catalogue
This Automatic Pipette will help you get your lab up and running in no time—at a great price! Features:
  • Lowest operation and tip ejection forces
  • Fully autoclavable
  • Ultra light weight with space-age materials
  • Secondary adjustment option for various liquid classes
  • Spring loaded tip con
  • For transferring molecular samples and PCR mix solutions.
  • One set is for DNA work and the other for RNA work. Each with the following specs
  • Light weight, traditional tip shaft, and will fit all generic brands of tips
  • Equal to or better than accuracy and precision compared to ISO 8655, so results can be trusted.
  • Easy and quick volume adjustment with or without gloves. Foolproof volume lock prevents accidental volume changes.
  • Low maintenance and autoclavable 121° for at least 20 minutes
  • Quick release
The coagulometer, LabPad® INR, measures blood coagulation time thanks to a patented optical technology. This portable In-Vitro Diagnostics (IVD) device works with the Tsmart® INR single-use microcuvettes.
  • User-friendly: the LabPad® INR is designed to be easy to use especially thanks to its 3D-shaped microcuvette that only requires a small drop of blood from a fingertip. Thanks to the color screen, both measurement steps and browsing the list of results are easy to visualize.
  • Quick and reliable: the reliability of INR results is obtained by quality controls that are performed automatically before each measurement. In less than one minute, you can see if you are in your therapeutic range.
  • Connected: the result obtained after performing the test can be transferred to healthcare professionals in charge of your treatment monitoring. This result is complementary to the pie charts and trend reports directly displayed on the LabPad® INR to help you monitoring your treatment
 
Click Here To Download Catalogue
   
The technical innovation of the iSED® fully-automated ESR analyzer consists of directly measuring the intensity of the red cell aggregation which is responsible for Erythrocyte Sedimentation Rate (ESR). Unlike traditional ESR methodologies that measure the aggregation of the red blood cells indirectly, the iSED measures it directly and expresses the values in mm/hr. Features:
  • Results in 20 Seconds

  • 100µL sample drawn directly from primary EDTA tube

  • Fully automated, walk-away operation

  • Random access

  • Positive patient identification via internal barcode reader

  • Compatible with pediatric tube

     
Technical Specifications: 
Principle of Measure: Photometrical
Results: “Printed mm/hr, Range from 1-130 mm/hr”
Sample Requirements: 500uL whole blood, collected in EDTA anti-coagulant tested 24 hours from venipuncture at room temperature or refrigerated.
Tube Requirements: 13 x 75 mm, pierceable capped tube
Quality Control: Barcoded Seditrol® QC
Barcode Reader: Internal
Printer: Internal
Interface Specifications: serial RS232 port for LIS connection
Weight: 14 kg
Dimensions (H x W x D): 36 x 27 x 34 (cm) /14.3 x 10.5 x13.4 (in)
Voltage: 100-240VAC
Frequency Range: 50-60 Hz
Power: 160W
Click Here To Download Catalogue
800-1  electric centrifuge is widely used in hospitals, chemical and Biological Chemistry Laboratory for serum, plasma, immune qualitative analysis experiment. Has beautiful shape, large capacity, small volume, complete function. Its performance is stable, the speed is adjustable and can automatically adjust the balance, low temperature, high efficiency and wide applicability and advantages. Technical Specifications:
Type No.
800-1
Power  source
220V 50HZ     110V  60HZ
Speed Range (rpm)
0~4000(rpm)
Time Range(min)
0-60min
Capacity (ml)
20(ml)×6
Maximum centrifugal force(xg)
1790(xg)
Package Size (cm)
29*29*26
 
Click Here To Download Catalogue
WeightN/AN/AN/AN/AN/AN/A
DimensionsN/AN/AN/AN/AN/AN/A
Additional information
Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • Rating
  • Price
  • Description
Click outside to hide the comparison bar
Compare