/ /

Multigas Monitor AneSure Mini

$1,815.00

Shipped From Abroad

AneSure Mini can simultaneously measure anesthetic gas, ETCO2, and respiratory rate. Suitable for Emergency, Pre-hospital, and Intra-hospital transport, Operating room as well as ICU.

Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
SF1033560130170-14
Brands:: Kingst

Description

Features of AneSure Portable Multigas Monitor AneSure Mini
  • Portable And Lightweight

Suitable for emergency, pre-hospital, and intra-hospital transfer, operating room, and ICU, enhancing the safety of anesthesia

  • Alarm For Data Overrun And Suffocation

Quick warm-up with the first value displayed in 5 seconds, and accurate readings displayed in 15 seconds. 24-hour trend graphs, not lost when power off

  • Large Character Mode

The data can be seen from 5 meters away;

Turn on the unit, and it is ready to use instantly with no need to calibrate;

Automatic atmospheric pressure compensation; Economical adapters reduce usage costs.

  • Firm And Durable

Suitable for various medical environments (field, helicopter, etc.)

 

Specifications of AneSure Portable Multigas Monitor AneSure Mini
AC Input 100V -240V, 50Hz/60 Hz to 5VDC Adapter with 5V type-C USBadapter Cable.
Battery Built-in rechargeable lithium battery pack (3.7V, 1200mAH)
Temperature 5 to +50℃
Humidity ≤80%
Atmospheric pressure 55 – 115 kPa
Technique NDIR (Non-dispersive infrared gas analysis)
Sampling Mode Mainstream
EtCO2, FiCO2 measurement Range: 0 – 150mmHg or 0 – 20kPa or 0 – 19.7% (v/v)

Accuracy: ±2mmHg for CO2 range 0 – 40mmHg

±5% for CO2 range from 41 – 70mmHg

±8% for CO2 range from 71 – 100mmHg

±10% Over 100mmHg

Update/Averaging Time Option of every breath or 10, 20 or 30 seconds
FiN2O/EtN2O measurement Range: 0-100%

Accuracy: ± (2 vol% + 2% of reading)

FiHAL/EtHAL, FiENF/EtENF, FiISO/EtISO measurement Range: 0-12%

Accuracy: 0-8%: ± (0.15 vol% + 5% of reading); 8-12%: unspecified

FiSEV/EtSEV measurement Range: 0-15%

Accuracy: 0-10%: ± (0.15 vol% + 5% of reading); 10-15%: unspecified

FiDES/EtDES measurement Range: 0-25%

Accuracy: 0-18%: ± (0.15 vol% + 5% of reading); 18-25%: unspecified

All FiAG Update: every 2-3 breath

Trends: 24 hours on Screen Trend and Numeric

Atmospheric Pressure Compensation Auto-compensation for atmospheric pressure variation
Respiration Rate Range: 3 – 150 breaths/minute

Accuracy: ±1% of reading or ±1 breaths/min whichever is greater

Rise time CO2 is less than70ms;

N2O is less than300ms; Anesthetic gases (halothane, enflurane, isoflurane, sevoflurane, or desflurane) are less than 300ms

Warm Up Time <15 seconds
Agent threshold 0.2%, When an agent is identified, concentrations will be reported even below 0.2% as long as apnea is not detected
Alarm limits Apnea alarm limits:15-40 sec

High alarm limits EtCO2/ FiCO2:22-150mmHg

Low alarm limits EtCO2/ FiCO2: 00-60mmHg

High alarm limits FiHAL/EtHAL, FiENF/EtENF, FiISO/EtISO:1.0-8.0%

Low alarm limits FiHAL/EtHAL, FiENF/EtENF, FiISO/EtISO:0-6.5%

High alarm limits FiSEV/EtSEV:1.0-10.0%

Low alarm limits FiSEV/EtSEV:0-6.5%

High alarm limits FiDES/EtDES:1.0-18.0%

Low alarm limits FiDES/EtDES: 0-6.5%

High alarm limits FiN2O/EtN2O:26-100%

Low alarm limits FiN2O/EtN2O: 01-78%

The high alarm limits of respiration rate:4-150 breaths/min

The low alarm limits of respiration rate:0-140 breaths/min

Size 38 x 42 x 44mm (W x H x D)
Weight 80g (including lithium battery and adult airway adapter)
Airway Adapter Dead Space: 5ml (Adult/Pediatric)

1ml (Neonate)

Warranty & Maintenance/ Calibration One-year warranty on the Main Unit and Lithium Ion Rechargeable Battery

 

Application Scenarios of AneSure Portable Multigas Monitor AneSure Mini
  • Portable, accurate, and real-time anesthetic multi-gas monitor
  • AneSure-Mini can simultaneously measure anesthetic gas, ETCO2, and respiratory rate. It is suitable for Emergency, Pre-hospital, and Intra-hospital transport, Operating room as well as ICU.
  • It has an alarm function, which will alarm when the measured value reaches the alarm limits or when suffocation occurs.
  • The first data can be obtained within 5 seconds after power-on, and full accurate data can be obtained within 15 seconds; the 24-hour Etco2 graph will not be lost when power is off.
  • It has a large-character display mode, and the data can be clearly seen from more than 5 meters away.
  • It is ready to use after the power is on.
  • With simple maintenance and a sturdy structure, suitable for various harsh environments.

Reviews

There are no reviews yet.

Be the first to review “Multigas Monitor AneSure Mini”

Your email address will not be published. Required fields are marked *

Quick Comparison

Multigas Monitor AneSure Mini removeOxygen Concentrator 3Ltr. removeTimesco Jumper Fingertip Pulse Oximeter removeBistos BT-770-12.1" Touchscreen Patient Monitor removeElastomeric Pump (Disposable Infusion Pump) with PCA removeTimesco Orion Laryngoscope Set remove
NameMultigas Monitor AneSure Mini removeOxygen Concentrator 3Ltr. removeTimesco Jumper Fingertip Pulse Oximeter removeBistos BT-770-12.1" Touchscreen Patient Monitor removeElastomeric Pump (Disposable Infusion Pump) with PCA removeTimesco Orion Laryngoscope Set remove
ImageFingertip Pulse OximeterBistos BT-770-12.1" Touchscreen Patient MonitorTimesco Orion Laryngoscope Set
SKUSF1033560130170-14SF1033560084-40SF1033560084-2SF1033560059-1SF1033560084-18SF1033560084-53
Rating
Price

$1,815.00

$273.00

$17.00

$902.00

$0.00

$98.50

Stock
Availability
Add to cart

DescriptionShipped From Abroad AneSure Mini can simultaneously measure anesthetic gas, ETCO2, and respiratory rate. Suitable for Emergency, Pre-hospital, and Intra-hospital transport, Operating room as well as ICU.
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock
R&D Capacity: OEM, ODM, Other
Payment Terms: LC, T/T, PayPal
Customized: Customized
Certification: CE, FDA, ISO13485
Scale: Medium
Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In Stock Integrated with SPO2 probe and processing display module. Small in volume、light in weight and convenient in carrying. Operation of the product is simple ,low power consumption. SPO2 , PR and Ridisplay,. Pulse rate value display, bar graph display. Low-voltage indication: low-voltage indicator appears before working abnormally which is due to low-voltage. Automatically power off function: when the device is under the state of measuring interface . it will automatically power off within 5 seconds if the finger falls out of probe. Delivery & Availability: Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.Shipped from Abroad The Bistos BT-770 patient monitor is equipped with a 12.1" touchscreen display, which allows for an easy operation and readability with a powerful rechargeable battery guaranteeing a continuous operation of 5 hours to monitor ECG, SpO2, NIBP, temperature and respiration Delivery & Availability: Typically 14 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.In Stock This product make the tension of silicon capsule as the driving force to control the flow by micro porous tube, it was pre-selected by doctor base on patients'situation, and then and then handed over to the patients ' self- management “to relieve or ease the pain

Delivery & Availability:

Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In Stock Timesco’s laryngoscope sets are available in a variety of configurations to suit your requirements, containing 3 blades and 1 handle and supplied in a convenient polypropylene case. Alternatively, Timesco also supplies single-use sets as a ready to use a system containing one blade and one handle in a clear pouch.

Delivery & Availability:

Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Content
Features of AneSure Portable Multigas Monitor AneSure Mini
  • Portable And Lightweight
Suitable for emergency, pre-hospital, and intra-hospital transfer, operating room, and ICU, enhancing the safety of anesthesia
  • Alarm For Data Overrun And Suffocation
Quick warm-up with the first value displayed in 5 seconds, and accurate readings displayed in 15 seconds. 24-hour trend graphs, not lost when power off
  • Large Character Mode
The data can be seen from 5 meters away; Turn on the unit, and it is ready to use instantly with no need to calibrate; Automatic atmospheric pressure compensation; Economical adapters reduce usage costs.
  • Firm And Durable
Suitable for various medical environments (field, helicopter, etc.)  
Specifications of AneSure Portable Multigas Monitor AneSure Mini
AC Input 100V -240V, 50Hz/60 Hz to 5VDC Adapter with 5V type-C USBadapter Cable.
Battery Built-in rechargeable lithium battery pack (3.7V, 1200mAH)
Temperature 5 to +50℃
Humidity ≤80%
Atmospheric pressure 55 - 115 kPa
Technique NDIR (Non-dispersive infrared gas analysis)
Sampling Mode Mainstream
EtCO2, FiCO2 measurement Range: 0 – 150mmHg or 0 – 20kPa or 0 – 19.7% (v/v) Accuracy: ±2mmHg for CO2 range 0 - 40mmHg ±5% for CO2 range from 41 - 70mmHg ±8% for CO2 range from 71 - 100mmHg ±10% Over 100mmHg
Update/Averaging Time Option of every breath or 10, 20 or 30 seconds
FiN2O/EtN2O measurement Range: 0-100% Accuracy: ± (2 vol% + 2% of reading)
FiHAL/EtHAL, FiENF/EtENF, FiISO/EtISO measurement Range: 0-12% Accuracy: 0-8%: ± (0.15 vol% + 5% of reading); 8-12%: unspecified
FiSEV/EtSEV measurement Range: 0-15% Accuracy: 0-10%: ± (0.15 vol% + 5% of reading); 10-15%: unspecified
FiDES/EtDES measurement Range: 0-25% Accuracy: 0-18%: ± (0.15 vol% + 5% of reading); 18-25%: unspecified
All FiAG Update: every 2-3 breath Trends: 24 hours on Screen Trend and Numeric
Atmospheric Pressure Compensation Auto-compensation for atmospheric pressure variation
Respiration Rate Range: 3 - 150 breaths/minute Accuracy: ±1% of reading or ±1 breaths/min whichever is greater
Rise time CO2 is less than70ms; N2O is less than300ms; Anesthetic gases (halothane, enflurane, isoflurane, sevoflurane, or desflurane) are less than 300ms
Warm Up Time <15 seconds
Agent threshold 0.2%, When an agent is identified, concentrations will be reported even below 0.2% as long as apnea is not detected
Alarm limits Apnea alarm limits:15-40 sec High alarm limits EtCO2/ FiCO2:22-150mmHg Low alarm limits EtCO2/ FiCO2: 00-60mmHg High alarm limits FiHAL/EtHAL, FiENF/EtENF, FiISO/EtISO:1.0-8.0% Low alarm limits FiHAL/EtHAL, FiENF/EtENF, FiISO/EtISO:0-6.5% High alarm limits FiSEV/EtSEV:1.0-10.0% Low alarm limits FiSEV/EtSEV:0-6.5% High alarm limits FiDES/EtDES:1.0-18.0% Low alarm limits FiDES/EtDES: 0-6.5% High alarm limits FiN2O/EtN2O:26-100% Low alarm limits FiN2O/EtN2O: 01-78% The high alarm limits of respiration rate:4-150 breaths/min The low alarm limits of respiration rate:0-140 breaths/min
Size 38 x 42 x 44mm (W x H x D)
Weight 80g (including lithium battery and adult airway adapter)
Airway Adapter Dead Space: 5ml (Adult/Pediatric) 1ml (Neonate)
Warranty & Maintenance/ Calibration One-year warranty on the Main Unit and Lithium Ion Rechargeable Battery
 
Application Scenarios of AneSure Portable Multigas Monitor AneSure Mini
  • Portable, accurate, and real-time anesthetic multi-gas monitor
  • AneSure-Mini can simultaneously measure anesthetic gas, ETCO2, and respiratory rate. It is suitable for Emergency, Pre-hospital, and Intra-hospital transport, Operating room as well as ICU.
  • It has an alarm function, which will alarm when the measured value reaches the alarm limits or when suffocation occurs.
  • The first data can be obtained within 5 seconds after power-on, and full accurate data can be obtained within 15 seconds; the 24-hour Etco2 graph will not be lost when power is off.
  • It has a large-character display mode, and the data can be clearly seen from more than 5 meters away.
  • It is ready to use after the power is on.
  • With simple maintenance and a sturdy structure, suitable for various harsh environments.
Our anesthesia system is a precision crafted, life-sustaining device. When moving to an O2 concentrator from tanks, you should expect the same attention to detail. A full 8lpm O2 flowrate capability - gives better performance at lower flow rates 20psi pressure output - your anesthesia system was designed to work from pressure O2 concentrations average 93% +/- 3% Built-in Low O2 Concentration Alarm Small footprint of 15"x15"x22" Remarkably quiet Save money over time vs. tanks Eliminate contamination hazards of tanks coming and going in your facility Works with ALL manufacturer's brands of anesthesia systems
    • .
   
Integrated with SPO2 probe and processing display module • Small in volume, light in weight, convenient in carrying • Simple operation, lower power consumption • OLED screen display • SPO2, PR, bar graph of pulse, plethysmogram, blood perfusion index, battery indication display • 4 directions display, 6 display models, large fonts display • Brightness control, Demo mode, Setup menu • Movement interference • Alarm function and adjustable alarm parameters • Can be connected to mobile phones through Bluetooth; can support Android and iOS client • Auto power-off when no signal after 10s • Powered by 2*AAA alkaline batteries Specification: • Size: 62 x 37 x 32mm • Peak wavelength range of the light emitted from the probe: red light 660nm±3; infrared light 905nm±5 • Maximum optical output power of the probe: 1.2mW for infrared light (905nm) • Bluetooth module: 4.0 (single-mode) • Working temperature: 5℃ to 40℃ (41°F to 104°F) • Relative humidity: 15% to 80%, non-condensing • Atmospheric pressure: 70kPa to 106kPa • Rated voltage: DC 3V Package included: • 1 x JUMPER JPD-500F Bluetooth Fingertip Pulse Oximeter • 2 x AAA Batteries • 1 x Carry Case • 1 x Lanyard • 1 x English User Manual
Bistos BT-770 is a 12.1" touchscreen patient monitor designed for easy operations. SPECIFICATIONS
  • 12.1“ color TFT touch screen
  • ECG, Resp., SpO2, NIBP, Temp., CO2, IBP, Multi-gas, C.O., Masimo SpO2
  • Precise ECG measurement with pacemaker detection ST segment and 16 types of arrhythmia analysis Double overpressure protection for NIBP Intelligent cuff inflation pressure adjustment
  • Smart Hook/Stand design, provide multiple placement modes Plug & Play Modular IBP& C.O., Modular Printer Multiple configuration options: 4-channel IBP, CO2, invasive C.O., Multi-gas Over 5 hours continuous working on battery 12-15V wide range DC input, suitable for ambulance Capable to connect with central monitoring system HL7 export to clinical information systems (option)
 
Click Here To Download Catalogue
This product make the tension of silicon capsule as the driving force to control the flow by micro porous tube, it was pre-selected by doctor base on patients'situation, and then and then handed over to the patients ' self- management “to relieve or ease the pain Product Components: one-way valve medicated device, elastic liquid storage device, liquid medicine filter, current limiting device, automatic liquid feeding device ( CBI & PCA ), pipe and the external connector; Product Features: 1. The continued to liquid (CBI) make the drug-stored sac mechanical stretch as a driving force, limited the flow through the micro porous tube to the patient safely, effectively, slightly, continuous uniform injection of liquid to analgesic effect; extrusion pump body does not affect the liquid normal velocity; liquid filtering device which can control the particles enter the body better; 2. Continued to liquid + self control to liquid ( CBI+PCA ) make the drug-stored sac mechanical stretch as a driving force, limited the flow through the micro porous tube to the patient safely, effectively, slightly, continuous uniform injection of liquid to analgesic effect; Automatic medicated function is the patients can medicate according to pain independently. Extrusion pump body does not affect the liquid normal velocity; liquid filtering device which can control the particles enter the body better; How to use: 1. Get analgesia pump out from sterile packaging, removing the cap of medicine inlet and outlet; pour the analgesic liquid in the liquid storage device, draw out the air from the liquid storage. 2. Finish medicating, waiting for the liquid outflow from the medicine outlet; please clamp tightly to stop flowing for preparation. 3. Control keys (PCA key) is a function key to add the medicine base on continue to medicated by patients' self-controlled. So the patients can self-control the PCA key under the guidance of doctors, according to the needs while they are in treatment. At the same time, doctor should fill in PCA treatment card, so that they can analyze the condition from PCA additional times.Timesco’s laryngoscope sets are available in a variety of configurations to suit your requirements, containing 3 blades and 1 handle and supplied in a convenient polypropylene case. Alternatively, Timesco also supply single use sets as a ready to use system containing one blade and one handle in a clear pouch.
  • A clear, impact resistant polypropylene case, which allows the contents to be clearly visible.
  • Designed to hold Macintosh 2, 3 and 4 blades and a laryngoscope handle.
  • There is a unique flexible button on the lid to allow EES engines and handles to be tested without opening the case.
  • Contains BioCote silver phosphate glass antimicrobial technology to preserve the surface and prevent degradation caused by microbial growth.
  • Set consists of Orion handle, Orion Mac 4, 3 & 2 blades
  • CE marked
  • Latex free
  • Extensive guarantees
  • ISO 7376 compatible
  • Supplied with multilingual instructions
Click Here To Download Catalogue
WeightN/AN/AN/AN/AN/AN/A
DimensionsN/AN/AN/AN/AN/AN/A
Additional information
Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • Rating
  • Price
  • Description
Click outside to hide the comparison bar
Compare