Near-Infrared Spectrophotometer

$0.00

Shipped From Abroad

Model : SP-NIR450

An NIR (Near-Infrared) Spectrophotometer measures the absorption of near-infrared light (typically 780-2500 nm) by a sample. It’s widely used in agriculture, pharmaceuticals, and chemical industries for its ability to provide rapid and non-destructive analysis of the chemical composition and physical properties of a sample.

Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
SF1033560130127-72
Brands:: Scitek

Description

Near-Infrared Spectrophotometer Features:

1. There is no need to treat the sample before testing to protect the integrity of the sample.

2. 900nm-2500nm ultra-wide spectral range, fast analysis speed.

3. Core parts are all internationally famous brands

4. Built-in high-quality PTFE reference module automatic reference calibration to ensure the accuracy of measurement results.

5. Equipped with integrating sphere diffuse reflection system, large sampling spot and sample turntable

6. All tests use NIST traceable standards.

7. Liquid, powder, support particles, film and other forms of sample detection.

8. The instrument’s real-time environmental temperature and humidity monitoring allows users to optimize the measurement conditions.

9. Simple operation and intuitive user interface.

10. Can establish authoritative and professional near-infrared quantitative and qualitative analysis models.

Near-Infrared Spectrophotometer Specifications:
Model SP-NIR450
Measurement Mode The diffuse reflection sample cell
Detector Japan hamamatsu cooled InGaAs
Spectral Bandwidth(nm) 12
Wavelength Range(nm) 900-2500 nm
Wavelength Accuracy(nm) ≤0.2
Wavelength Repeatability(nm) ≤0.05
Stray Light(%) ≤0.1
Absorbance Noise(Abs) ≤0.0005
Analysis Time 1min (adjustable)
Data Transmission Mode USB2.0
Calibration Technology MPLS Modified least squares regression calibration technology
DPLS Spectrum identification and qualitative analysis technology
Item Content
Electricity 90-250V\50Hz (or 60Hz)
Ambient Temperature (℃) 5-35
Ambient Humidity (%RH) 5-85
Size(W×D×H)(mm) 540×380×220
Shipping Size(W×D×H)(mm) 780x550x400
N.W./G.W. (kg) 18/25

Reviews

There are no reviews yet.

Be the first to review “Near-Infrared Spectrophotometer”

Your email address will not be published. Required fields are marked *

Quick Comparison

SettingsNear-Infrared Spectrophotometer removeSkyla HB1 POC Clinical Chemistry Auto Analyzer removeAvalun 48 INR Microcuvette removeiSED Fully Automated ESR Analyzer removeNikon SMZ745 Stereoscopic Microscope removeErma B-111 Bilirubin Meter remove
NameNear-Infrared Spectrophotometer removeSkyla HB1 POC Clinical Chemistry Auto Analyzer removeAvalun 48 INR Microcuvette removeiSED Fully Automated ESR Analyzer removeNikon SMZ745 Stereoscopic Microscope removeErma B-111 Bilirubin Meter remove
ImageAvalun 48 INR MicrocuvetteNikon SMZ745 Stereoscopic Microscope
SKUSF1033560130127-72SF1033560060-1SF1033560084-74SF1033560084-129SF1033560084-49SF1033560084-6
Rating
Price

$0.00

$0.00

$0.00

$0.00

$0.00

$715.00

Stock

Out of stock

AvailabilityOut of stock
Add to cart

DescriptionShipped From Abroad Model : SP-NIR450 An NIR (Near-Infrared) Spectrophotometer measures the absorption of near-infrared light (typically 780-2500 nm) by a sample. It’s widely used in agriculture, pharmaceuticals, and chemical industries for its ability to provide rapid and non-destructive analysis of the chemical composition and physical properties of a sample.
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped from Abroad The skyla HB1 Clinical Chemistry Analyzer provides clinical testing laboratories of medical facilities and clinics with an in-vitro clinical chemistry diagnostic tool that is compact, portable, and reports rapid results. The portable design of the clinical chemistry analyzer utilizes precision photometric measurement technology, combined with the single-use disposable reagent discs. The reagent disc contains a set of dry assay reagents that are used in the quantitative testing of various biomarkers in the blood sample. Delivery & Availability: Typically 14 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.Out stock LabPad®’s versatility comes especially from its Tsmart® single-use microcuvette, which contains a lyophilized reagent specific to each test. The Tsmart® microcuvette is the fruit of numerous innovations that have led to many benefits for users. Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.In stock
The technical innovation of the iSED® fully-automated ESR analyzer consists of directly measuring the intensity of the red cell aggregation which is responsible for Erythrocyte Sedimentation Rate (ESR). Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock Nikon SMZ745 Stereoscopic Microscope: Featuring a zoom magnification of 7.5X and a long working distance of 115mm, Nikon SMZ745 microscopes are well suited for both industrial and biomedical applications. The adoption of a new total reflection prism produces brighter images with higher contrast, and the anti-mold design allows the microscope to be used in environments where the temperature and humidity are high. The SMZ-745T trinocular model comes equipped with a microscope camera port and a built-in 0.55x c-mount adapter, permitting direct mounting of Nikon DS Series Digital Cameras. Delivery & Availability: Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.Shipped From Aboard  The advanced B111 Bilirubinmeter provides fast, accurate results for Total bilirubin level in neonates with only 40μl serum or plasma sample. It determines total bilirubin by dual wavelength photometric analysis. Suited for pediatric setups, small workload labs & hospitals because of its compact and portable design. Advanced, benchtop and precise instrument for measuring Total Bilirubin.

Delivery & Availability:

Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Content
Near-Infrared Spectrophotometer Features:
1. There is no need to treat the sample before testing to protect the integrity of the sample. 2. 900nm-2500nm ultra-wide spectral range, fast analysis speed. 3. Core parts are all internationally famous brands 4. Built-in high-quality PTFE reference module automatic reference calibration to ensure the accuracy of measurement results. 5. Equipped with integrating sphere diffuse reflection system, large sampling spot and sample turntable 6. All tests use NIST traceable standards. 7. Liquid, powder, support particles, film and other forms of sample detection. 8. The instrument's real-time environmental temperature and humidity monitoring allows users to optimize the measurement conditions. 9. Simple operation and intuitive user interface. 10. Can establish authoritative and professional near-infrared quantitative and qualitative analysis models.
Near-Infrared Spectrophotometer Specifications:
Model SP-NIR450
Measurement Mode The diffuse reflection sample cell
Detector Japan hamamatsu cooled InGaAs
Spectral Bandwidth(nm) 12
Wavelength Range(nm) 900-2500 nm
Wavelength Accuracy(nm) ≤0.2
Wavelength Repeatability(nm) ≤0.05
Stray Light(%) ≤0.1
Absorbance Noise(Abs) ≤0.0005
Analysis Time 1min (adjustable)
Data Transmission Mode USB2.0
Calibration Technology MPLS Modified least squares regression calibration technology
DPLS Spectrum identification and qualitative analysis technology
Item Content
Electricity 90-250V\50Hz (or 60Hz)
Ambient Temperature (℃) 5-35
Ambient Humidity (%RH) 5-85
Size(W×D×H)(mm) 540×380×220
Shipping Size(W×D×H)(mm) 780x550x400
N.W./G.W. (kg) 18/25
Skyla HB1 Clinical Chemistry Analyzer utilizes precision photometric measurement technology, combined with the single-use disposable reagent discs. The reagent disc contains a set of dry assay reagents that are used in the quantitative testing of various biomarkers in the blood sample. HB1 provides clinical testing laboratories of medical facilities and clinics with an in-vitro clinical chemistry diagnostic tool that is compact, portable, and reports rapid results. Only needs 200µl of blood (whole blood, serum or plasma is accepted.) and no sample preparation is required. All steps are designed automatically from checking the validity of reagent discs and cartridges to printing the results. Over 30 test parameters are allowed with fast analysis and results in 15 minutes. Internal Quality Control (IQC) with self-calibration of optical system, chemicals stability and interference alerts functions monitor and ensure the results with high accuracy. Available Test Panels
  • Renal Function - BUN, CREA eGFR
  • Liver Function - ALB, TP, ALP, ALT, AST, TBIL, DBIL, GGT, LDH A/G#, GLOB#, IBIL
  • Lipid Metabolism - TG, TC, HDL LDL#, VLDL
  • Pancreatitis Markers - AMY, LIPA
  • Carbohydrate Metabolism and Others - GLU , CPK, UA, LAC
  • Inflammatory Markers - CRP
  • Electrolyte - Na, K, Cl, Ca, PHOS, Mg, tCO2
SPECIFICATION Principle
  • Colormetric System : LEDs 340nm~940nm wavelength
Sample & Panel
  • Test Profiles : Panels
  • Measurement Time - Panel: up to 15 tests/ 15 min
  • Sample Type & Volume : 200 μl whole blood (PCV<60%), plasma, serum 
Device
  • User Interface : 5 inch color LCD touch screen
  • Internal Memory : Store up to 50,000 analysis results
  • Printer : Built in thermal printer or external USB printer (PCL 3GUI)
  • USB Socket : USB type A (Host) for external USB Printer, USB flash drive (FAT) or external barcode scanner
  • Data transmission to PC : RS232 serial port or RJ45 (LAN)
  • Dimensions : 233 (W) X 285 (D) X 300 (H) mm
  • Weight : 5.5 kg
Operating Condition
  • Temperature / Humidity : 10 to 32˚C / 5 to 90 %
 
Click Here To Download Catalogue
LabPad®’s versatility comes especially from its Tsmart® single-use microcuvette, which contains a lyophilized reagent specific to each test. The Tsmart® microcuvette is the fruit of numerous innovations that have led to many benefits for users.
Features:
  • Fully automated "plug-and-play"   behavior
  • Reduced blood volume (only 3µL)
  • A large space for blood drop-off
  • Fills up quickly, using just capillarity
  • Easy handling, thanks to its 3D shape
  • Optimized preservation in individual pouches, in boxes of 12, 24, or 48 units
The technical innovation of the iSED® fully-automated ESR analyzer consists of directly measuring the intensity of the red cell aggregation which is responsible for Erythrocyte Sedimentation Rate (ESR). Unlike traditional ESR methodologies that measure the aggregation of the red blood cells indirectly, the iSED measures it directly and expresses the values in mm/hr. Features:
  • Results in 20 Seconds

  • 100µL sample drawn directly from primary EDTA tube

  • Fully automated, walk-away operation

  • Random access

  • Positive patient identification via internal barcode reader

  • Compatible with pediatric tube

     
Technical Specifications: 
Principle of Measure: Photometrical
Results: “Printed mm/hr, Range from 1-130 mm/hr”
Sample Requirements: 500uL whole blood, collected in EDTA anti-coagulant tested 24 hours from venipuncture at room temperature or refrigerated.
Tube Requirements: 13 x 75 mm, pierceable capped tube
Quality Control: Barcoded Seditrol® QC
Barcode Reader: Internal
Printer: Internal
Interface Specifications: serial RS232 port for LIS connection
Weight: 14 kg
Dimensions (H x W x D): 36 x 27 x 34 (cm) /14.3 x 10.5 x13.4 (in)
Voltage: 100-240VAC
Frequency Range: 50-60 Hz
Power: 160W
Click Here To Download Catalogue
Nikon SMZ745 Stereoscopic Microscope: Featuring a zoom magnification of 7.5X and a long working distance of 115mm, Nikon SMZ745 microscopes are well suited for both industrial and biomedical applications. The adoption of a new total reflection prism produces brighter images with higher contrast, and the anti-mold design allows the microscope to be used in environments where the temperature and humidity are high. The SMZ-745 trinocular model comes equipped with a microscope camera port and a built-in 0.55x c-mount adapter, permitting direct mounting of Nikon DS Series Digital Cameras. Features:
  • Trinocular optical head for monitoring and digital imaging
  • Impressive 7.5x zoom magnification
  • 115 mm working distance
  • Maximum ergonomics
  • Rugged, durable design suits a variety of applications and environments
Technical Specifications:
Optical system Greenough optical system
Total magnification 3.35-300x, depending on eyepiece and auxiliary objective used
Vertical tube Built-in C-mount 0.55x magnification lens (F.N. 11), compatible with 2/3 in. or smaller CCD
Eyepiece tube Fixed type
Eyepiece inclination 45°
Interpupillary distance adjustment 52-75 mm
Eyepieces (with diopter adjustment) C-W 10xB (F.N. 22), C-W 15x (F.N. 16), C-W 20x (F.N. 12.5), C-W 30x (F.N. 7)
Zooming ratio 7.5:1 (approx.)
Zooming range 0.67-5x
Auxiliary objectives G-AL 0.5x (W.D. 211 mm), G-AL 0.7x (W.D. 150 mm), G-AL 1.5x (W.D. 61 mm), G-AL 2x (W.D. 43.5 mm)
Working distance 115 mm
     
 
 
The advanced B111 Bilirubinmeter provides fast, accurate results for Total bilirubin level in neonates with only 40μl serum or plasma sample. It determines total bilirubin by dual wavelength photometric analysis. Suited for pediatric setups, small workload labs & hospitals because of its compact and portable design. Advanced, benchtop and precise instrument for measuring Total Bilirubin. Feature
  • Auto zero function: Manual blanking not required
  • Dual wavelength measurement system:
  • 2 wave lengths 455nm and 575nm
  • Plays major role to remove the interference caused due to Hemolysis & turbidity of sample
  • LED Light source:
  • LED does not require replacement as it lasts longer
  • As compared to Lamp, LED are more suitable as there is no intensity fluctuations
  • No warm up time required.
  • Flexible unit selection:
  • Two units either mg/dl or umol/L are selectable, ease of reporting
  • Compact slot for Capillary:
  • Accuracy of results are directly related to proper alignment of Capillary
  • B-111 has the easiest mode to ensure precise values
  • Data transfer:
  • External device can be connected to instrument through RS232 por
  • USB port
Technical Specification
  • Light source - LED
  • Wavelength - 455nm and 575nm
  • Net weight - 1kg
  • Measuring range - 0-30 mg/dl , 510 umol/L
  • Display - 16×2 LCD module with backlight
  • Auto calibration - Yes
  • Sample type - Serum or plasma
  • Sample volume - 40-80μL
  • Test time - <5sec
  • Units - mg/dl or umol/L
  • Dimensions - 150 (W) × 115 (H) × 190 (D) mm
  • Interface - RS232
  • Reading cuvette - Heparinized micro capillary holder
  • Storage temperature - 15-40°c
  • Power supply - DC 9V(DC adapter)
  • Power consumption - <2W
WeightN/AN/AN/AN/AN/AN/A
DimensionsN/AN/AN/AN/AN/AN/A
Additional information
Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • Rating
  • Price
  • Description
Click outside to hide the comparison bar
Compare