Near-Infrared Spectrophotometer

$0.00

Shipped From Abroad

Model : SP-NIR450

An NIR (Near-Infrared) Spectrophotometer measures the absorption of near-infrared light (typically 780-2500 nm) by a sample. It’s widely used in agriculture, pharmaceuticals, and chemical industries for its ability to provide rapid and non-destructive analysis of the chemical composition and physical properties of a sample.

Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
SF1033560130127-72
Brands:: Scitek

Description

Near-Infrared Spectrophotometer Features:

1. There is no need to treat the sample before testing to protect the integrity of the sample.

2. 900nm-2500nm ultra-wide spectral range, fast analysis speed.

3. Core parts are all internationally famous brands

4. Built-in high-quality PTFE reference module automatic reference calibration to ensure the accuracy of measurement results.

5. Equipped with integrating sphere diffuse reflection system, large sampling spot and sample turntable

6. All tests use NIST traceable standards.

7. Liquid, powder, support particles, film and other forms of sample detection.

8. The instrument’s real-time environmental temperature and humidity monitoring allows users to optimize the measurement conditions.

9. Simple operation and intuitive user interface.

10. Can establish authoritative and professional near-infrared quantitative and qualitative analysis models.

Near-Infrared Spectrophotometer Specifications:
Model SP-NIR450
Measurement Mode The diffuse reflection sample cell
Detector Japan hamamatsu cooled InGaAs
Spectral Bandwidth(nm) 12
Wavelength Range(nm) 900-2500 nm
Wavelength Accuracy(nm) ≤0.2
Wavelength Repeatability(nm) ≤0.05
Stray Light(%) ≤0.1
Absorbance Noise(Abs) ≤0.0005
Analysis Time 1min (adjustable)
Data Transmission Mode USB2.0
Calibration Technology MPLS Modified least squares regression calibration technology
DPLS Spectrum identification and qualitative analysis technology
Item Content
Electricity 90-250V\50Hz (or 60Hz)
Ambient Temperature (℃) 5-35
Ambient Humidity (%RH) 5-85
Size(W×D×H)(mm) 540×380×220
Shipping Size(W×D×H)(mm) 780x550x400
N.W./G.W. (kg) 18/25

Reviews

There are no reviews yet.

Be the first to review “Near-Infrared Spectrophotometer”

Your email address will not be published. Required fields are marked *

Quick Comparison

SettingsNear-Infrared Spectrophotometer removeAutomatic Pipette removeZenithlab (IB-9025A) Laboratory Incubator removeAlcohol Pad Per Pack removeErma B-111 Bilirubin Meter removeTest Strip for ApexBio HemoSmart Gold Hemoglobin Meter remove
NameNear-Infrared Spectrophotometer removeAutomatic Pipette removeZenithlab (IB-9025A) Laboratory Incubator removeAlcohol Pad Per Pack removeErma B-111 Bilirubin Meter removeTest Strip for ApexBio HemoSmart Gold Hemoglobin Meter remove
Image
SKUSF1033560130127-72SF1033560084-130SF1033560084-109SF1033560084-64SF1033560084-6SF1033560084-30
Rating
Price

$0.00

$0.00

$350.00

$4.25

$715.00

$9.50

Stock
Availability
Add to cart

DescriptionShipped From Abroad Model : SP-NIR450 An NIR (Near-Infrared) Spectrophotometer measures the absorption of near-infrared light (typically 780-2500 nm) by a sample. It’s widely used in agriculture, pharmaceuticals, and chemical industries for its ability to provide rapid and non-destructive analysis of the chemical composition and physical properties of a sample.
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock
This Automatic Pipette will help you get your lab up and running in no time—at a great price! Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock
  • Microprocessor control.
  • Digital display setting and actual temperature.
  • Over temperature alarm, PID self-tuning.
  • Digital display running timer.
  • Stainless steel interior.
  • Electricity leakage protection.
  • With glass inner door, With hidden door locks.
  • Mechanical overheat protection, cut off the heating sources.
  • Automatic alarm after operation.
  • Suitable for constant temperature tests.
  • Suitable for bacteria cultivation, breeding, ferment.
Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock Alcohol Pad (70% Isopropyl Alcohol Pre Pad, Alcohol Cleansing Swab). Clean the required area. Discard after single use. Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.Shipped From Aboard  The advanced B111 Bilirubinmeter provides fast, accurate results for Total bilirubin level in neonates with only 40μl serum or plasma sample. It determines total bilirubin by dual wavelength photometric analysis. Suited for pediatric setups, small workload labs & hospitals because of its compact and portable design. Advanced, benchtop and precise instrument for measuring Total Bilirubin.

Delivery & Availability:

Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In Stock Twenty Five (25) Test Strip per Pack

Delivery & Availability:

Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Content
Near-Infrared Spectrophotometer Features:
1. There is no need to treat the sample before testing to protect the integrity of the sample. 2. 900nm-2500nm ultra-wide spectral range, fast analysis speed. 3. Core parts are all internationally famous brands 4. Built-in high-quality PTFE reference module automatic reference calibration to ensure the accuracy of measurement results. 5. Equipped with integrating sphere diffuse reflection system, large sampling spot and sample turntable 6. All tests use NIST traceable standards. 7. Liquid, powder, support particles, film and other forms of sample detection. 8. The instrument's real-time environmental temperature and humidity monitoring allows users to optimize the measurement conditions. 9. Simple operation and intuitive user interface. 10. Can establish authoritative and professional near-infrared quantitative and qualitative analysis models.
Near-Infrared Spectrophotometer Specifications:
Model SP-NIR450
Measurement Mode The diffuse reflection sample cell
Detector Japan hamamatsu cooled InGaAs
Spectral Bandwidth(nm) 12
Wavelength Range(nm) 900-2500 nm
Wavelength Accuracy(nm) ≤0.2
Wavelength Repeatability(nm) ≤0.05
Stray Light(%) ≤0.1
Absorbance Noise(Abs) ≤0.0005
Analysis Time 1min (adjustable)
Data Transmission Mode USB2.0
Calibration Technology MPLS Modified least squares regression calibration technology
DPLS Spectrum identification and qualitative analysis technology
Item Content
Electricity 90-250V\50Hz (or 60Hz)
Ambient Temperature (℃) 5-35
Ambient Humidity (%RH) 5-85
Size(W×D×H)(mm) 540×380×220
Shipping Size(W×D×H)(mm) 780x550x400
N.W./G.W. (kg) 18/25
This Automatic Pipette will help you get your lab up and running in no time—at a great price! Features:
  • Lowest operation and tip ejection forces
  • Fully autoclavable
  • Ultra light weight with space-age materials
  • Secondary adjustment option for various liquid classes
  • Spring loaded tip con
  • For transferring molecular samples and PCR mix solutions.
  • One set is for DNA work and the other for RNA work. Each with the following specs
  • Light weight, traditional tip shaft, and will fit all generic brands of tips
  • Equal to or better than accuracy and precision compared to ISO 8655, so results can be trusted.
  • Easy and quick volume adjustment with or without gloves. Foolproof volume lock prevents accidental volume changes.
  • Low maintenance and autoclavable 121° for at least 20 minutes
  • Quick release
Features:
  • Microprocessor control.
  • Digital display setting and actual temperature.
  • Over temperature alarm, PID self-tuning.
  • Digital display running timer.
  • Stainless steel interior.
  • Electricity leakage protection.
  • With glass inner door, With hidden door locks.
  • Mechanical overheat protection, cut off the heating sources.
  • Automatic alarm after operation.
  • Suitable for constant temperature tests.
  • Suitable for bacteria cultivation, breeding, ferment.
  Technical Specification: Model: IB-9025A Working size: 250x250x250mm/9.84x9.84x9.84inch Power: 150W Temperature range: Room temperature+5~65℃ Temperature resolution: 0.1℃ Temperature fluctuation: ±0.5℃ Timer: 0-9999min Voltage: 110V 60Hz / 220V 50Hz Dimension: 380x370x580mm/14.96x14.57x22.83inch Size: 52cm*46cm*75cm / 20.5in*18.2in*29.6in Gross Weight:42kg / 93lb Net Weight: 23kg / 51lb Warranty: 1 year
Alcohol Pad (70% Isopropyl Alcohol Pre Pad, Alcohol Cleansing Swab). Clean the required area. Discard after single use. Size and packing of Medical Alcohol pad:
  • Pad Size: Unfolded: 30 x 60 mm (other size can be request ).
  • Folded: 30x30 mm, 30 x 35mm,can be 2ply or 4ply ( other size, ply can be request ).
  • Aluminum Package: 60 x 50 mm , 50 x 50mm approximate ( other size can be request ).
  • Packing: 100/200 pcs per inner box, 50/ 100 boxes per carton(packing can be request).
Use of Medical Alcohol pad:
  • For cleaning prior to injection or to disinfect the hurted skin for family and medical treatment organization use.
  • For preparation and immediate disinfection of skin, wound area orr Instrument and utensil.
Notice of Medical Alcohol pad:
  • Not for eyes;
  • keep out of reach of children;
  • For external use only;
  • please stop using if you feel allergic or amyctic
Materials - Non-Woven Fabric
Trademark - OEM/ODM
Specification - CE&ISO13485
   
The advanced B111 Bilirubinmeter provides fast, accurate results for Total bilirubin level in neonates with only 40μl serum or plasma sample. It determines total bilirubin by dual wavelength photometric analysis. Suited for pediatric setups, small workload labs & hospitals because of its compact and portable design. Advanced, benchtop and precise instrument for measuring Total Bilirubin. Feature
  • Auto zero function: Manual blanking not required
  • Dual wavelength measurement system:
  • 2 wave lengths 455nm and 575nm
  • Plays major role to remove the interference caused due to Hemolysis & turbidity of sample
  • LED Light source:
  • LED does not require replacement as it lasts longer
  • As compared to Lamp, LED are more suitable as there is no intensity fluctuations
  • No warm up time required.
  • Flexible unit selection:
  • Two units either mg/dl or umol/L are selectable, ease of reporting
  • Compact slot for Capillary:
  • Accuracy of results are directly related to proper alignment of Capillary
  • B-111 has the easiest mode to ensure precise values
  • Data transfer:
  • External device can be connected to instrument through RS232 por
  • USB port
Technical Specification
  • Light source - LED
  • Wavelength - 455nm and 575nm
  • Net weight - 1kg
  • Measuring range - 0-30 mg/dl , 510 umol/L
  • Display - 16×2 LCD module with backlight
  • Auto calibration - Yes
  • Sample type - Serum or plasma
  • Sample volume - 40-80μL
  • Test time - <5sec
  • Units - mg/dl or umol/L
  • Dimensions - 150 (W) × 115 (H) × 190 (D) mm
  • Interface - RS232
  • Reading cuvette - Heparinized micro capillary holder
  • Storage temperature - 15-40°c
  • Power supply - DC 9V(DC adapter)
  • Power consumption - <2W
Twenty Five (25) Test Strip per Pack
WeightN/AN/AN/AN/AN/AN/A
DimensionsN/AN/AN/AN/AN/AN/A
Additional information
Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • Rating
  • Price
  • Description
Click outside to hide the comparison bar
Compare