NEUROSTIM is a Transcranial Electrical Stimulator (TES) designed for neuromodulation, neuroprotection, and rehabilitation. It delivers precise electrical stimulation to targeted brain areas, aiding in motor cortex mapping, neurological recovery, and cognitive enhancement. Ideal for neurologists, neurosurgeons, and rehabilitation specialists, NEUROSTIM ensures safe, effective, and customizable stimulation for both clinical and research applications. With its advanced technology and user-friendly interface, it enhances treatment precision and patient outcomes in neuroscience and neurorehabilitation.
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Description
DC output current – up to 2mA
Neurostim is intended for the transcranial noninvasive stimulation with direct low current (up to 2 mA).
The current generates the electrical field changing the brain cortex excitability. Such brain impact has therapeutic effect in the treatment of different disorders including fibromyalgia, major depressive episode, addiction/craving, lower limb neuropathic pain and recovery of motor functions after stroke and brain injuries.
Continuous monitoring of electrode impedance
It is very important to keep the reliable skin-electrode contact during the whole stimulation procedure. Poor electrode contact due to improper electrode placement or dry-out can result in decreased therapeutic effect. Neurostim ensures continuous impedance monitoring. If the electrode impedance is too high, a notification will sound and the stimulation will be terminated (paused).
Two modes of use: inpatient and outpatient
For inpatient treatment Neurostim is supplied with pre-defined treatment protocols for most commonly used therapy. Just select the protocol for the particular patient from the list.
For outpatient treatment you should create a treatment course (up to 250 stimulation sessions). A patient will start the treatment sessions one by one. The completed session will be locked and cannot be used for the treatment.
USB connection for advanced control
The software can be used to control and adjust stimulator through USB. In this mode the stimulator is also powered through USB. The software is a simple way to manage the session list. You can add, remove, edit, import and export session, download user-defined waveform.
Features
- smulus current – up to 5 mA (30 V)
- smulaon duraon – up to 40 min
- smulus type:
- tDCS (transcranial direct current smulaon)
- tACS (transcranial alternang current smulaon)
- tRNS (transcranial random noise smulaon)
- tDCS-Sham (transcranial direct current smulaon + sham)
- tPCS (transcranial pulse current smulaon) custom waveform
- secure administrator mode to set up sessions
- operaon modes:
- stand-alone
- USB-controlled (smulaon by specified protocol; creaon and eding of smulaon protocols)
Specifications
- 1 channel transcranial smulator for unipolar (DC) and bipolar (AC) smulaon
- adjustable smulus current of 0 up to 5 mA with 25 µA increment
- adjustable smulaon duraon of 15 s to 40 min with 5 s increment
- 16 bit D/A conversion
- sampling rate:
tACS – 33 kHz
tRNS – 10 kHz
tDCS – 500 Hz
tPCS – 10 kHz - storage – 250 smulaon sessions
- power supply: from 9 V baery of 6LR61 or HR22 type or rechargeable batteries (up to 3 hours)
from USB of +5 V (galvanically isolated up to 4000 V)
Quick Comparison
NEUROSTIM-Transcranial Electrical Stimulator remove | BRAINSWAY Deep TMS H7 RCT Coil remove | DF-20A-HM Auto CPAP remove | Falcon-QUAD Transcranial Doppler Probe remove | Ectron Ectonustim Series 6 Electroconvulsive Therapy ECT Machine remove | Dolphin-XF Transcranial Robotic Probe remove | |||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Name | NEUROSTIM-Transcranial Electrical Stimulator remove | BRAINSWAY Deep TMS H7 RCT Coil remove | DF-20A-HM Auto CPAP remove | Falcon-QUAD Transcranial Doppler Probe remove | Ectron Ectonustim Series 6 Electroconvulsive Therapy ECT Machine remove | Dolphin-XF Transcranial Robotic Probe remove | ||||||||||||||||||||
Image | ![]() | ![]() | ![]() | ![]() | ![]() | ![]() | ||||||||||||||||||||
SKU | SF1033560130187-33 | SF1033560130162-6 | SF1033560130180-5 | SF1033560130142-6 | SF10335601235 | SF1033560130142-4 | ||||||||||||||||||||
Rating | ||||||||||||||||||||||||||
Price |
|
|
|
|
| $6,270.00 | ||||||||||||||||||||
Stock | ||||||||||||||||||||||||||
Availability | ||||||||||||||||||||||||||
Add to cart | ||||||||||||||||||||||||||
Description | Shipped From Abroad
NEUROSTIM is a Transcranial Electrical Stimulator (TES) designed for neuromodulation, neuroprotection, and rehabilitation. It delivers precise electrical stimulation to targeted brain areas, aiding in motor cortex mapping, neurological recovery, and cognitive enhancement. Ideal for neurologists, neurosurgeons, and rehabilitation specialists, NEUROSTIM ensures safe, effective, and customizable stimulation for both clinical and research applications. With its advanced technology and user-friendly interface, it enhances treatment precision and patient outcomes in neuroscience and neurorehabilitation.
Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| Shipped From Abroad
The H7 Coil stimulates the anterior cingulate cortex and the medial prefrontal cortex. Treatment is designed to regulate the CSTC circuit believed to be involved in the inhibition of impulsive behavior. A sham coil is integrated above the treatment coil. To the patient and operator, the helmet appears the same, pulses sound the same, and stimulation feels the same on the scalp.
Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| Shipped From Abroad
The VentMed DF-20A-HM Auto CPAP is designed for sleep apnea therapy, offering automatic pressure adjustment for comfortable breathing support. It includes a heated humidifier and has an ultra-low noise level of 22 dBA, ensuring quiet operation.
Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| Shipped From Abroad State-of-the-Art technology to measure ABI, TBI, Doppler, PVR, PPG and stress testing. Falcon advanced EMR and PACS capabilities and reporting options are designed for medical centers and private clinics alikeDelivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| Shipped From Abroad
This machines have been developed from the well-proven Series 5A and 5B ECT apparatus. The series 6+ models incorporate all the features of the corresponding Series 5B versions. Experience has shown that a very few patients sometimes require higher dosage than was available with the earlier machines and the opportunity was therefore taken to produce equipment with a second, higher, output range. Delivery & Availability: Typically 3 Months – excluding furniture and heavy/bulky equipment. Please contact us for further information. | Shipped From Abroad
Proudly introducing the X-Factor in TCD robotic solutions, assisting in obtaining bilateral TCD insonations in as quickly as just a few seconds!. Designed for short and long-term monitoring, for use in anesthesia, in the ICU, or in the TCD lab.
Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| ||||||||||||||||||||
Content | DC output current – up to 2mA
Neurostim is intended for the transcranial noninvasive stimulation with direct low current (up to 2 mA).
The current generates the electrical field changing the brain cortex excitability. Such brain impact has therapeutic effect in the treatment of different disorders including fibromyalgia, major depressive episode, addiction/craving, lower limb neuropathic pain and recovery of motor functions after stroke and brain injuries.
Continuous monitoring of electrode impedance
It is very important to keep the reliable skin-electrode contact during the whole stimulation procedure. Poor electrode contact due to improper electrode placement or dry-out can result in decreased therapeutic effect. Neurostim ensures continuous impedance monitoring. If the electrode impedance is too high, a notification will sound and the stimulation will be terminated (paused).
Two modes of use: inpatient and outpatient
For inpatient treatment Neurostim is supplied with pre-defined treatment protocols for most commonly used therapy. Just select the protocol for the particular patient from the list.
For outpatient treatment you should create a treatment course (up to 250 stimulation sessions). A patient will start the treatment sessions one by one. The completed session will be locked and cannot be used for the treatment.
USB connection for advanced control
The software can be used to control and adjust stimulator through USB. In this mode the stimulator is also powered through USB. The software is a simple way to manage the session list. You can add, remove, edit, import and export session, download user-defined waveform.
Features
Specifications
| The Brainsway Deep TMS H7 RCT Coil is a flexible coil used in transcranial magnetic stimulation (TMS) to treat obsessive-compulsive disorder (OCD) and other neuropsychiatric conditions:
Features
| Specifications:
This device is lightweight and user-friendly, featuring an intuitive display and advanced noise-canceling technology for a comfortable sleep experience | https://youtu.be/YSWvhSIS1ho?si=rXtjG78U7PQgzrlf
Features of Falcon Physiologic Machine | This machines have been developed from the well-proven Series 5A and 5B ECT apparatus. The series 6+ models incorporate all the features of the corresponding Series 5B versions. Experience has shown that a very few patients sometimes require higher dosage than was available with the earlier machines and the opportunity was therefore taken to produce equipment with a second, higher, output range.
Features:
Constant Current stimulus
Delivered Dosage Displayed
Patient Dynamic Impedance Indicator
Simple Single Dose Control
Technical Specification:
Input Supply: AC 100-120, 210-240 V 40/60 Hz
Load: 70 W
Apparatus Size: 305 x 170 x 105mm (12” x 6.5” x 4”)
Weight: 3.24kg
Low Range: 50-700mC @ 750mA
High Range: 200-100mC @ 900mA
Contents:
Two-hand headpiece: 1
C.S lead: 1
Disposable electrodes: 50
Mains cable: 1
Operating & service manual: 1
Removable stand: 1
Click Here To Download Catalogue | https://youtu.be/JwSJvUVJrxo?si=6QkpitWAwvZZSwOM
DescriptionThe Dolphin/XF is a new breakthrough development in TCD robotics. It is designed to assist the user in quickly and automatically insonating and monitoring cerebral blood flow.Features | ||||||||||||||||||||
Weight | N/A | N/A | N/A | N/A | N/A | N/A | ||||||||||||||||||||