NEUROSTIM-Transcranial Electrical Stimulator

$0.00

Shipped From Abroad

NEUROSTIM is a Transcranial Electrical Stimulator (TES) designed for neuromodulation, neuroprotection, and rehabilitation. It delivers precise electrical stimulation to targeted brain areas, aiding in motor cortex mapping, neurological recovery, and cognitive enhancement. Ideal for neurologists, neurosurgeons, and rehabilitation specialists, NEUROSTIM ensures safe, effective, and customizable stimulation for both clinical and research applications. With its advanced technology and user-friendly interface, it enhances treatment precision and patient outcomes in neuroscience and neurorehabilitation.

Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
SF1033560130187-33
Brands:: Neurosoft

Description

DC output current – up to 2mA

Neurostim is intended for the transcranial noninvasive stimulation with direct low current (up to 2 mA).

The current generates the electrical field changing the brain cortex excitability. Such brain impact has therapeutic effect in the treatment of different disorders including fibromyalgia, major depressive episode, addiction/craving, lower limb neuropathic pain and recovery of motor functions after stroke and brain injuries.

Continuous monitoring of electrode impedance

It is very important to keep the reliable skin-electrode contact during the whole stimulation procedure. Poor electrode contact due to improper electrode placement or dry-out can result in decreased therapeutic effect.  Neurostim ensures continuous impedance monitoring. If the electrode impedance is too high, a notification will sound and the stimulation will be terminated (paused).

Two modes of use: inpatient  and outpatient

For inpatient treatment Neurostim is supplied with pre-defined treatment protocols for most commonly used therapy. Just select the protocol for the particular patient from the list.

For outpatient treatment you should create a treatment course (up to 250 stimulation sessions). A patient will start the treatment sessions one by one. The completed session will be locked and cannot be used for the treatment.

USB connection for advanced control

The software can be used to control and adjust stimulator through USB. In this mode the stimulator is also powered through USB.  The software is a simple way to manage the session list. You can add, remove, edit, import and export session, download user-defined waveform.

Features
  • smulus current – up to 5 mA (30 V)
  • smulaon duraon – up to 40 min
  • smulus type:
  • tDCS (transcranial direct current smulaon)
  • tACS (transcranial alternang current smulaon)
  • tRNS (transcranial random noise smulaon)
  • tDCS-Sham (transcranial direct current smulaon + sham)
  •  tPCS (transcranial pulse current smulaon) custom waveform
  • secure administrator mode to set up sessions
  • operaon modes:
  • stand-alone
  • USB-controlled (smulaon by specified protocol; creaon and eding of smulaon protocols)
Specifications
  • 1 channel transcranial smulator for unipolar (DC) and bipolar (AC) smulaon
  • adjustable smulus current of 0 up to 5 mA with 25 µA increment
  • adjustable smulaon duraon of 15 s to 40 min with 5 s increment
  • 16 bit D/A conversion
  • sampling rate:
    tACS – 33 kHz
    tRNS – 10 kHz
    tDCS – 500 Hz
    tPCS – 10 kHz
  • storage – 250 smulaon sessions
  •  power supply: from 9 V baery of 6LR61 or HR22 type or rechargeable batteries (up to 3 hours)
    from USB of +5 V (galvanically isolated up to 4000 V)

Download Brochure

Reviews

There are no reviews yet.

Be the first to review “NEUROSTIM-Transcranial Electrical Stimulator”

Your email address will not be published. Required fields are marked *

Quick Comparison

NEUROSTIM-Transcranial Electrical Stimulator removeBRAINSWAY Deep TMS H1 Coil removeDolphin-4D Transcranial Doppler Probe removeRetractors removeFalcon-QUAD Transcranial Doppler Probe removeBRAINSWAY Deep TMS H4 Coil remove
NameNEUROSTIM-Transcranial Electrical Stimulator removeBRAINSWAY Deep TMS H1 Coil removeDolphin-4D Transcranial Doppler Probe removeRetractors removeFalcon-QUAD Transcranial Doppler Probe removeBRAINSWAY Deep TMS H4 Coil remove
Image
SKUSF1033560130187-33SF1033560130162-4SF1033560130142-1SF1033560130176-9SF1033560130142-6SF1033560130162-7
Rating
Price

$0.00

$0.00

$0.00

$0.00

$0.00

$0.00

Stock
Availability
Add to cart

DescriptionShipped From Abroad NEUROSTIM is a Transcranial Electrical Stimulator (TES) designed for neuromodulation, neuroprotection, and rehabilitation. It delivers precise electrical stimulation to targeted brain areas, aiding in motor cortex mapping, neurological recovery, and cognitive enhancement. Ideal for neurologists, neurosurgeons, and rehabilitation specialists, NEUROSTIM ensures safe, effective, and customizable stimulation for both clinical and research applications. With its advanced technology and user-friendly interface, it enhances treatment precision and patient outcomes in neuroscience and neurorehabilitation.
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad
The H1 Coil stimulates the bilateral prefrontal cortex, with a preference for the left dorsolateral prefrontal cortex. In addition to numerous published, double-blind, randomized controlled trials validating the efficacy of Deep TMS for depression, clinical data of over 1,000 patients in real practice settings has shown compelling results. Among patients who completed 30 sessions, approximately 4 out of 5 achieved a clinical response, and approximately 2 out of 3 achieved remission from depression.
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad The cutting-edge technology of the standalone Dolphin/4D transcranial Doppler system is the optimal TCD solution for measurements of cerebral blood flow velocities.
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.

Shipped From Abroad

State-of-the-Art technology to measure ABI, TBI, Doppler, PVR, PPG and stress testing. Falcon advanced EMR and PACS capabilities and reporting options are designed for medical centers and private clinics alike
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad The H4 Coil stimulates the bilateral insula and prefrontal cortex. Nearly 1 in 3 patients who completed 18 sessions achieved 4 or more weeks of abstinence from smoking in a large scale, double-blind, multicenter randomized controlled trial. 2 out of 3 patients who quit smoking by the end of treatment remained abstinent for at least an additional three months
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
ContentDC output current – up to 2mA Neurostim is intended for the transcranial noninvasive stimulation with direct low current (up to 2 mA). The current generates the electrical field changing the brain cortex excitability. Such brain impact has therapeutic effect in the treatment of different disorders including fibromyalgia, major depressive episode, addiction/craving, lower limb neuropathic pain and recovery of motor functions after stroke and brain injuries. Continuous monitoring of electrode impedance It is very important to keep the reliable skin-electrode contact during the whole stimulation procedure. Poor electrode contact due to improper electrode placement or dry-out can result in decreased therapeutic effect.  Neurostim ensures continuous impedance monitoring. If the electrode impedance is too high, a notification will sound and the stimulation will be terminated (paused). Two modes of use: inpatient  and outpatient For inpatient treatment Neurostim is supplied with pre-defined treatment protocols for most commonly used therapy. Just select the protocol for the particular patient from the list. For outpatient treatment you should create a treatment course (up to 250 stimulation sessions). A patient will start the treatment sessions one by one. The completed session will be locked and cannot be used for the treatment. USB connection for advanced control The software can be used to control and adjust stimulator through USB. In this mode the stimulator is also powered through USB.  The software is a simple way to manage the session list. You can add, remove, edit, import and export session, download user-defined waveform.
Features
  • smulus current – up to 5 mA (30 V)
  • smulaon duraon – up to 40 min
  • smulus type:
  • tDCS (transcranial direct current smulaon)
  • tACS (transcranial alternang current smulaon)
  • tRNS (transcranial random noise smulaon)
  • tDCS-Sham (transcranial direct current smulaon + sham)
  •  tPCS (transcranial pulse current smulaon) custom waveform
  • secure administrator mode to set up sessions
  • operaon modes:
  • stand-alone
  • USB-controlled (smulaon by specified protocol; creaon and eding of smulaon protocols)
Specifications
  • 1 channel transcranial smulator for unipolar (DC) and bipolar (AC) smulaon
  • adjustable smulus current of 0 up to 5 mA with 25 µA increment
  • adjustable smulaon duraon of 15 s to 40 min with 5 s increment
  • 16 bit D/A conversion
  • sampling rate: tACS – 33 kHz tRNS – 10 kHz tDCS – 500 Hz tPCS – 10 kHz
  • storage – 250 smulaon sessions
  •  power supply: from 9 V baery of 6LR61 or HR22 type or rechargeable batteries (up to 3 hours) from USB of +5 V (galvanically isolated up to 4000 V)
Download Brochure
The BrainsWay Deep TMS H1 Coil is a transcranial magnetic stimulation (TMS) device that's used to treat depression and other mental disorders: 
  • Design
    The H1 Coil is a flexible, soft copper coil that's placed inside a helmet to stimulate the brain. The coil's design allows for a wider and deeper distribution of magnetic fields than traditional TMS coils.
  • Effectiveness
    The H1 Coil is effective in treating depression and has also been explored as a treatment for other conditions:
    • DepressionThe H1 Coil is FDA-cleared to treat major depressive disorder (MDD) in adults who haven't responded well to other antidepressant medications.
    • Other conditionsThe H1 Coil has been explored as a treatment for negative symptoms of schizophrenia, bipolar depression, and migraine.
  • Benefits
    The H1 Coil's design allows for greater neuron activation, which can lead to more effective stimulation and fewer targeting errors.
  • Safety
    The H1 Coil is considered a safe and effective clinical tool.
Features
  • Flexible base
    The H1 coil has a flexible base that can adapt to the shape of the patient's head. 
  • Tangential coil components
    The H1 coil has tangential coil components that are close to the brain targets. 
  • Parallel coil components
    The H1 coil has parallel coil components that direct the electric pulse beams. 
  • Electrical pulses
    The H1 coil has numerous electrical pulses that converge from various directions. 
  • Return paths
    The return paths of the electrical pulses are located at a distance from the target area. 
  • Stimulates the prefrontal cortex
    The H1 coil stimulates the bilateral prefrontal cortex, with a preference for the left dorsolateral prefrontal cortex (DLPFC). 
  • Deeper and broader stimulation
    The H1 coil's patented design enables deeper and broader stimulation than traditional TMS coils.
    Click here to download Brochure
https://youtu.be/Id0Ma1_lEo0?si=MmwcCTMMPZd_jf6h
Features of Dolphin TCD Machine

Best Quality Doppler

Fully digital Doppler technology with the amazing Dolphin TCD post-processing capabilities lets you review and replay the measured spectrum with audio at any depth. Unmatched clinical diagnosis capabilities.

Best TCD Robotic Probe

The unique Dolphin/XF robotic probe changes the Transcranial Doppler monitoring market as is known to date. Fast and simple scanning is achieved thanks to special algorithms and processes for blood flow detection. The Dolphin/XF robot is comfortable and stable, simplifying probe fixation and saving time.

Continuous Monitoring Made Easy

The Dolphin devices are well designed to assist the technician or physician in performing short or long-term Monitoring. The Dolphin Headset design comes with the unique probe Quick-Lock – the best locking solution. The Dolphin software is rich with quality features for optimal patient diagnosis, including a complete replay of the entire recording, placement of automatic and predefined markers, and availability of trends display.

Unbeatable Durability and Reliability

The Dolphin is considered by many as the most reliable Transcranial Doppler machine in the market. A range of high-quality Doppler probes is available for different clinical applications and optimal Doppler penetration of the temporal window.

Designed for Portability

The Dolphin TCD machines are the most portable TCD machine on the market. Dolphin/MAX and Dolphin/4D are slim, lightweight, and have a large 18″ Touch Screen, which can be seen from a distance in the ICU or other clinical settings. Their design allows you to simply hand carry them or use the VESA mount options to easily connect the TCD system to a cart or trolley. The Dolphin/MAX has a built-in integrated battery that lasts for hours.

Complete Network Connectivity

The unmatched Dolphin connectivity capabilities are ideal for hospital IT personnel and EMR / PACS administrators. The advanced Dolphin TCD networking abilities allow a simple plug-and-play operation to quickly configure connectivity with automated DICOM Worklist & Storage, Structured Report, and HL7. With unlimited Review Stations, measurements can be reanalyzed and interpreted from the comfort of your office. Final reporting can also be configured and finalized from any location.

Unmatched HITS Detection

Optimal and accurate counts of suspected embolic events using a high-resolution proprietary algorithm that simultaneously detects HITS (emboli events) in all gates! The numerous advanced analysis options of each suspected emboli include an extraordinary high-resolution power M Mode display during HITS detection (up to 50 times faster than the Doppler spectrum!).
CODE SIZE FINISH
01-01-02 12.8 cm sharp
https://youtu.be/YSWvhSIS1ho?si=rXtjG78U7PQgzrlf  
Features of Falcon Physiologic Machine

Segmental Blood Pressures

Measure lower extremity pressures easily with 10 color-coded channels and a variety of Doppler probes and PPG sensors. Complete the vascular diagnosis with supportive stress testing. Falcon is considered by many the best segmental pressure machine with numerous advanced features such as 10 simultaneous PVR measurements and limitless post-processing capabilities.

Fast and Accurate ABI & TBI

Quickly measure ABI and TBI with either Doppler or Photoplethysmography (PPG). With the Falcon ABI and TBI machine, all measurements are saved automatically and sent directly to the dedicated interactive summary screen.

Highest Durability and Reliability

The Falcon is the most reliable peripheral vascular machine in the market. Thanks to the high quality Doppler probes, 10 Independent Pressure Channels (IPU Technology) and 5 PPG Ports, the Falcon design significantly reduces any down-time. Falcon is in distributed worldwide for over 10 years with the lowest fail rate in the market!

Complete Network Connectivity

The Falcon unmatched connectivity capabilities are a paradise to hospital IT personnel and EMR and PACS managers. The advanced networking abilities allow a plug-and-play operation to easily configure connectivity with automated DICOM Worklist & Storage, Structured Report, and HL7. With unlimited Review Stations, measurements can be reanalyzed and interpreted from the comfort of your office. Final reporting can also be configured and finalized from any location.

Simplify Your Workflow

The Falcon vascular diagnosis device has the ability to configure as many dedicated examination protocols that allow to save time and optimize the patient vascular diagnosis​. Enjoy the user-friendly protocol builder to configure your workflow according to your needs!​

Ease of Use

Minimal learning curve thanks to user-friendly software with a large touch-screen display. A selection of wired and wireless remote control​ and footswitch allows keeping your focus on the patient rather than on the physiologic vascular equipment.

Dedicated Specialty Tests

The Falcon is the complete vascular physiologic assessment machine with dedicated protocols that guide you through step-by-step diagnostic measurements of specific vascular conditions.  The dedicated diagnosis protocols include measurements of Thoracic Outlet Syndrome (TOS), diagnosis of Raynaud’s Phenomenon, evaluation of Penile Function or Erectile Dysfunction, assessment of Allen’s Test (or Palmar Arch Test), measurements of Venous Reflux and Venous Capacitance and Outflow, Pulse Wave Velocity, and more.
Advanced Reporting The famous Falcon user-friendly report builder tool allows you to design your own report layout easily. Then, add your institute/clinic logo and details to create a detailed and impressive diagnosis report that meets your institute standards. Save a lot of time by building your report with preconfigured interpretation templates.

Advanced Research Options

The Falcon vascular research machine is famous for its built-in statistics tool with on-screen graphs, segments filtering, and Excel tool, which are all designed to simplify the work of vascular and physiological researchers. Export to PDF, Excel, Word, JPEG, VSX, Video clips, and more to support your vascular research and teaching needs, as well as support your clinical vascular publications.
The BrainsWay Deep TMS H4 Coil is a non-invasive treatment that uses magnetic energy waves to stimulate brain structures associated with addiction and weight loss: 
  • Treatment
    The H4 Coil is used to treat smoking addiction and weight loss. It generates electromagnetic pulses that stimulate the bilateral insula and prefrontal cortex of the brain.
  • Benefits
    Deep TMS is a well-tolerated treatment that can be integrated into a patient's daily schedule. It's said to have no side effects and no recovery period. Patients may start to feel relief from symptoms within a few weeks.
  • Technology
    The H4 Coil is part of a helmet that contains BrainsWay's patented H-Coils, which are designed to stimulate deeper and broader areas of the brain than traditional TMS coils. The helmet also has a touchscreen interface, adjustable positioning arm, and cooling system.
  • Safety
    The H4 Coil has lower rates of headache, treatment site discomfort, and jaw pain than other coils, but higher rates of general discomfort

Click here to download Brochure

WeightN/AN/AN/AN/AN/AN/A
DimensionsN/AN/AN/AN/AN/AN/A
Additional information
Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • Rating
  • Price
  • Description
Click outside to hide the comparison bar
Compare