NEUROSTIM-Transcranial Electrical Stimulator

$0.00

Shipped From Abroad

NEUROSTIM is a Transcranial Electrical Stimulator (TES) designed for neuromodulation, neuroprotection, and rehabilitation. It delivers precise electrical stimulation to targeted brain areas, aiding in motor cortex mapping, neurological recovery, and cognitive enhancement. Ideal for neurologists, neurosurgeons, and rehabilitation specialists, NEUROSTIM ensures safe, effective, and customizable stimulation for both clinical and research applications. With its advanced technology and user-friendly interface, it enhances treatment precision and patient outcomes in neuroscience and neurorehabilitation.

Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
SF1033560130187-33
Brands:: Neurosoft

Description

DC output current – up to 2mA

Neurostim is intended for the transcranial noninvasive stimulation with direct low current (up to 2 mA).

The current generates the electrical field changing the brain cortex excitability. Such brain impact has therapeutic effect in the treatment of different disorders including fibromyalgia, major depressive episode, addiction/craving, lower limb neuropathic pain and recovery of motor functions after stroke and brain injuries.

Continuous monitoring of electrode impedance

It is very important to keep the reliable skin-electrode contact during the whole stimulation procedure. Poor electrode contact due to improper electrode placement or dry-out can result in decreased therapeutic effect.  Neurostim ensures continuous impedance monitoring. If the electrode impedance is too high, a notification will sound and the stimulation will be terminated (paused).

Two modes of use: inpatient  and outpatient

For inpatient treatment Neurostim is supplied with pre-defined treatment protocols for most commonly used therapy. Just select the protocol for the particular patient from the list.

For outpatient treatment you should create a treatment course (up to 250 stimulation sessions). A patient will start the treatment sessions one by one. The completed session will be locked and cannot be used for the treatment.

USB connection for advanced control

The software can be used to control and adjust stimulator through USB. In this mode the stimulator is also powered through USB.  The software is a simple way to manage the session list. You can add, remove, edit, import and export session, download user-defined waveform.

Features
  • smulus current – up to 5 mA (30 V)
  • smulaon duraon – up to 40 min
  • smulus type:
  • tDCS (transcranial direct current smulaon)
  • tACS (transcranial alternang current smulaon)
  • tRNS (transcranial random noise smulaon)
  • tDCS-Sham (transcranial direct current smulaon + sham)
  •  tPCS (transcranial pulse current smulaon) custom waveform
  • secure administrator mode to set up sessions
  • operaon modes:
  • stand-alone
  • USB-controlled (smulaon by specified protocol; creaon and eding of smulaon protocols)
Specifications
  • 1 channel transcranial smulator for unipolar (DC) and bipolar (AC) smulaon
  • adjustable smulus current of 0 up to 5 mA with 25 µA increment
  • adjustable smulaon duraon of 15 s to 40 min with 5 s increment
  • 16 bit D/A conversion
  • sampling rate:
    tACS – 33 kHz
    tRNS – 10 kHz
    tDCS – 500 Hz
    tPCS – 10 kHz
  • storage – 250 smulaon sessions
  •  power supply: from 9 V baery of 6LR61 or HR22 type or rechargeable batteries (up to 3 hours)
    from USB of +5 V (galvanically isolated up to 4000 V)

Download Brochure

Reviews

There are no reviews yet.

Be the first to review “NEUROSTIM-Transcranial Electrical Stimulator”

Your email address will not be published. Required fields are marked *

Quick Comparison

SettingsNEUROSTIM-Transcranial Electrical Stimulator removeSelf-Retaining Retractor removeDolphin-IQ Transcranial Doppler Probe removeNitrogen Generator/Plant removeOxygen Generator/Plant removeBRAINSWAY Deep TMS 104 RCT System remove
NameNEUROSTIM-Transcranial Electrical Stimulator removeSelf-Retaining Retractor removeDolphin-IQ Transcranial Doppler Probe removeNitrogen Generator/Plant removeOxygen Generator/Plant removeBRAINSWAY Deep TMS 104 RCT System remove
Image
SKUSF1033560130187-33SF1033560130176-10SF1033560130142-3SF103356013077SF103356013076SF1033560130162-3
Rating
Price

$0.00

$0.00

$6,325.00

$0.00

$0.00

$0.00

Stock
Availability
Add to cart

DescriptionShipped From Abroad NEUROSTIM is a Transcranial Electrical Stimulator (TES) designed for neuromodulation, neuroprotection, and rehabilitation. It delivers precise electrical stimulation to targeted brain areas, aiding in motor cortex mapping, neurological recovery, and cognitive enhancement. Ideal for neurologists, neurosurgeons, and rehabilitation specialists, NEUROSTIM ensures safe, effective, and customizable stimulation for both clinical and research applications. With its advanced technology and user-friendly interface, it enhances treatment precision and patient outcomes in neuroscience and neurorehabilitation.
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad All of the advantages and performance of the cutting-edge Dolphin TCD technology for measurements of cerebral blood flow velocities are implemented in the smart and compact Dolphin/IQ Transcranial Doppler module.
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad
PSA Industrıal nitrogen generator systems produce gas nitrogen from compressed air from the field where they work, and switch compatible to conventional nitrogen gas source such as tubes or cryogenic liqiud. Delivery & Availability: Typically, 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad
PSA Medical & Industrial oxygen generator systems produce gas oxygen from compressed air from the field where they work and switch compatible to conventional oxygen gas source such as tubes or cryogenic liquid. Delivery & Availability: Typically, 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad BrainsWay's 104 RCT System enables blinded clinical research via a card reader that randomizes selection of sham or Deep TMS stimulation. The sham coil is integrated into the helmet with the treatment coil, producing similar sounds and sensations.
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
ContentDC output current – up to 2mA Neurostim is intended for the transcranial noninvasive stimulation with direct low current (up to 2 mA). The current generates the electrical field changing the brain cortex excitability. Such brain impact has therapeutic effect in the treatment of different disorders including fibromyalgia, major depressive episode, addiction/craving, lower limb neuropathic pain and recovery of motor functions after stroke and brain injuries. Continuous monitoring of electrode impedance It is very important to keep the reliable skin-electrode contact during the whole stimulation procedure. Poor electrode contact due to improper electrode placement or dry-out can result in decreased therapeutic effect.  Neurostim ensures continuous impedance monitoring. If the electrode impedance is too high, a notification will sound and the stimulation will be terminated (paused). Two modes of use: inpatient  and outpatient For inpatient treatment Neurostim is supplied with pre-defined treatment protocols for most commonly used therapy. Just select the protocol for the particular patient from the list. For outpatient treatment you should create a treatment course (up to 250 stimulation sessions). A patient will start the treatment sessions one by one. The completed session will be locked and cannot be used for the treatment. USB connection for advanced control The software can be used to control and adjust stimulator through USB. In this mode the stimulator is also powered through USB.  The software is a simple way to manage the session list. You can add, remove, edit, import and export session, download user-defined waveform.
Features
  • smulus current – up to 5 mA (30 V)
  • smulaon duraon – up to 40 min
  • smulus type:
  • tDCS (transcranial direct current smulaon)
  • tACS (transcranial alternang current smulaon)
  • tRNS (transcranial random noise smulaon)
  • tDCS-Sham (transcranial direct current smulaon + sham)
  •  tPCS (transcranial pulse current smulaon) custom waveform
  • secure administrator mode to set up sessions
  • operaon modes:
  • stand-alone
  • USB-controlled (smulaon by specified protocol; creaon and eding of smulaon protocols)
Specifications
  • 1 channel transcranial smulator for unipolar (DC) and bipolar (AC) smulaon
  • adjustable smulus current of 0 up to 5 mA with 25 µA increment
  • adjustable smulaon duraon of 15 s to 40 min with 5 s increment
  • 16 bit D/A conversion
  • sampling rate: tACS – 33 kHz tRNS – 10 kHz tDCS – 500 Hz tPCS – 10 kHz
  • storage – 250 smulaon sessions
  •  power supply: from 9 V baery of 6LR61 or HR22 type or rechargeable batteries (up to 3 hours) from USB of +5 V (galvanically isolated up to 4000 V)
Download Brochure
CODE SIZE FINISH
01-01-02 12.8 cm sharp
https://youtu.be/Id0Ma1_lEo0?si=kRJ1bUMjUCBuCAqR  
Features of Dolphin TCD Machine

Best Quality Doppler

Fully digital Doppler technology with the amazing Dolphin TCD post-processing capabilities lets you review and replay the measured spectrum with audio at any depth. Unmatched clinical diagnosis capabilities.

Best TCD Robotic Probe

The unique Dolphin/XF robotic probe changes the Transcranial Doppler monitoring market as is known to date. Fast and simple scanning is achieved thanks to special algorithms and processes for blood flow detection. The Dolphin/XF robot is comfortable and stable, simplifying probe fixation and saving time.

Continuous Monitoring Made Easy

The Dolphin devices are well designed to assist the technician or physician in performing short or long-term Monitoring. The Dolphin Headset design comes with the unique probe Quick-Lock – the best locking solution. The Dolphin software is rich with quality features for optimal patient diagnosis, including a complete replay of the entire recording, placement of automatic and predefined markers, and availability of trends display.

Unbeatable Durability and Reliability

The Dolphin is considered by many as the most reliable Transcranial Doppler machine in the market. A range of high-quality Doppler probes is available for different clinical applications and optimal Doppler penetration of the temporal window.

Designed for Portability

The Dolphin TCD machines are the most portable TCD machine on the market. Dolphin/MAX and Dolphin/4D are slim, lightweight, and have a large 18″ Touch Screen, which can be seen from a distance in the ICU or other clinical settings. Their design allows you to simply hand carry them or use the VESA mount options to easily connect the TCD system to a cart or trolley. The Dolphin/MAX has a built-in integrated battery that lasts for hours.

Complete Network Connectivity

The unmatched Dolphin connectivity capabilities are ideal for hospital IT personnel and EMR / PACS administrators. The advanced Dolphin TCD networking abilities allow a simple plug-and-play operation to quickly configure connectivity with automated DICOM Worklist & Storage, Structured Report, and HL7. With unlimited Review Stations, measurements can be reanalyzed and interpreted from the comfort of your office. Final reporting can also be configured and finalized from any location.

Unmatched HITS Detection

Optimal and accurate counts of suspected embolic events using a high-resolution proprietary algorithm that simultaneously detects HITS (emboli events) in all gates! The numerous advanced analysis options of each suspected emboli include an extraordinary high-resolution power M Mode display during HITS detection (up to 50 times faster than the Doppler spectrum!).
PSA Industrıal nitrogen generator systems produce gas nitrogen from compressed air from the field where they work, and switch compatible to conventional nitrogen gas source such as tubes or cryogenic liqiud.

ADVANTAGES OF NITROGEN GENERATORS/PLANT

  • High flow capacity: The wide product range and gas flows exceeding 1,000 Nm³/h

  • Desired purity: Nitrogen concentrations from 95% to 99.999%.

  • Continuous availability: 24 hours a day, 7 days a week

  • Cost savings: Low operating expenses, limited maintenance costs.

  • Fully automated and monitored including oxygen sensor as standard.

Wide Range Of Applications

  • Food & beverage (storage & packaging).

  • Pharmaceutical applications.

  • Plastic injection molding.

  • Electronics.

  • Laser cutting.

  • Semiconductor manufacturing.

  • Chemical applications.

  • Metal heat treatment.

  • Cable & optical fiber industries.

  • Glass industries.

  • Fire prevention.

  • Aquaculture.

grafik_son.jpg
PSA Medical & Industrıal oxygen generator systems produce gas oxygen from compressed air from the field where they work and switch compatible to conventional oxygen gas source such as tubes or cryogenic liqiud.

OXYGEN PURITY - PSA oxygen generators, continuously 90-95% purity oxygen produces.

OXYGEN FLOW - LINAIR TECHNOLOGIES manufactures oxygen generators with capacities from 1 Nm3/h to 1000 Nm3/h.

OXYGEN OUTLET PRESSURE - Oxygen generators produces 4-6 bar oxygen.

ADVANTAGES OF OXYGEN GENERATORS/Plant

  • Consistently high purity guaranteed.

  • Oxygen production according to your needs 24/7.

  • Purity control of instantaneously produced oxygen.

  • Instant monitoring of parameters such as purity, pressure, flow rate on the screen.

  • No need for an extra operator since it works fully automatically.

The BrainsWay Deep TMS 104 RCT System is a non-invasive treatment for mental health conditions that uses magnetic pulses to stimulate the brain.
  • ComponentsIncludes a stimulator, touchscreen interface, cooling system, and card reader 
  • TreatmentPatients wear a helmet with electromagnetic coils that deliver magnetic pulses to the brain 
  • PurposeTreats conditions like major depressive disorder (MDD), obsessive-compulsive disorder (OCD), and smoking cessation 
  • SafetyWell-tolerated treatment with a favorable safety profile 
  • EffectivenessResearch shows that Deep TMS is effective in alleviating symptoms 
  • InsuranceMany insurance providers offer coverage for Deep TMS 
  • Ease of useDesigned to be easy to use for operators and comfortable for patients 
  • Sham-enabledVersions are available for randomized controlled clinical research 
 
Features
The BrainsWay Deep TMS 104 RCT System has several features, including:
  • H-CoilsThe system's patented H-Coils are flexible and embedded in a cushioned, cooled helmet that fits each patient's head. The H-Coils provide deeper and broader stimulation than traditional TMS coils, which are rigid and shaped like a figure-8. 
  • Touchscreen interfaceThe system has an intuitive touchscreen interface. 
  • Cooling systemThe system has an efficient cooling system. 
  • Card readerThe system has a card reader that randomly selects sham or Deep TMS stimulation. 
  • Sham-enabled versionsSham-enabled versions are available for randomized controlled clinical research.
 

Click here to download Brochure 

WeightN/AN/AN/AN/AN/AN/A
DimensionsN/AN/AN/AN/AN/AN/A
Additional information
Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • Rating
  • Price
  • Description
Click outside to hide the comparison bar
Compare