NEUROSTIM-Transcranial Electrical Stimulator
$0.00
Shipped From Abroad
NEUROSTIM is a Transcranial Electrical Stimulator (TES) designed for neuromodulation, neuroprotection, and rehabilitation. It delivers precise electrical stimulation to targeted brain areas, aiding in motor cortex mapping, neurological recovery, and cognitive enhancement. Ideal for neurologists, neurosurgeons, and rehabilitation specialists, NEUROSTIM ensures safe, effective, and customizable stimulation for both clinical and research applications. With its advanced technology and user-friendly interface, it enhances treatment precision and patient outcomes in neuroscience and neurorehabilitation.
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Description
DC output current – up to 2mA
Neurostim is intended for the transcranial noninvasive stimulation with direct low current (up to 2 mA).
The current generates the electrical field changing the brain cortex excitability. Such brain impact has therapeutic effect in the treatment of different disorders including fibromyalgia, major depressive episode, addiction/craving, lower limb neuropathic pain and recovery of motor functions after stroke and brain injuries.
Continuous monitoring of electrode impedance
It is very important to keep the reliable skin-electrode contact during the whole stimulation procedure. Poor electrode contact due to improper electrode placement or dry-out can result in decreased therapeutic effect. Neurostim ensures continuous impedance monitoring. If the electrode impedance is too high, a notification will sound and the stimulation will be terminated (paused).
Two modes of use: inpatient and outpatient
For inpatient treatment Neurostim is supplied with pre-defined treatment protocols for most commonly used therapy. Just select the protocol for the particular patient from the list.
For outpatient treatment you should create a treatment course (up to 250 stimulation sessions). A patient will start the treatment sessions one by one. The completed session will be locked and cannot be used for the treatment.
USB connection for advanced control
The software can be used to control and adjust stimulator through USB. In this mode the stimulator is also powered through USB. The software is a simple way to manage the session list. You can add, remove, edit, import and export session, download user-defined waveform.
Features
- smulus current – up to 5 mA (30 V)
- smulaon duraon – up to 40 min
- smulus type:
- tDCS (transcranial direct current smulaon)
- tACS (transcranial alternang current smulaon)
- tRNS (transcranial random noise smulaon)
- tDCS-Sham (transcranial direct current smulaon + sham)
- tPCS (transcranial pulse current smulaon) custom waveform
- secure administrator mode to set up sessions
- operaon modes:
- stand-alone
- USB-controlled (smulaon by specified protocol; creaon and eding of smulaon protocols)
Specifications
- 1 channel transcranial smulator for unipolar (DC) and bipolar (AC) smulaon
- adjustable smulus current of 0 up to 5 mA with 25 µA increment
- adjustable smulaon duraon of 15 s to 40 min with 5 s increment
- 16 bit D/A conversion
- sampling rate:
tACS – 33 kHz
tRNS – 10 kHz
tDCS – 500 Hz
tPCS – 10 kHz - storage – 250 smulaon sessions
- power supply: from 9 V baery of 6LR61 or HR22 type or rechargeable batteries (up to 3 hours)
from USB of +5 V (galvanically isolated up to 4000 V)
Quick Comparison
Settings | NEUROSTIM-Transcranial Electrical Stimulator remove | Falcon-QUAD Transcranial Doppler Probe remove | Dolphin-4D Transcranial Doppler Probe remove | Falcon-PRO Transcranial Doppler Probe remove | Nitrogen Generator/Plant remove | Somatics Electroconvulsive Therapy (ECT) Machine remove |
---|---|---|---|---|---|---|
Name | NEUROSTIM-Transcranial Electrical Stimulator remove | Falcon-QUAD Transcranial Doppler Probe remove | Dolphin-4D Transcranial Doppler Probe remove | Falcon-PRO Transcranial Doppler Probe remove | Nitrogen Generator/Plant remove | Somatics Electroconvulsive Therapy (ECT) Machine remove |
Image | ![]() | ![]() | ![]() | ![]() | ![]() | ![]() |
SKU | SF1033560130187-33 | SF1033560130142-6 | SF1033560130142-1 | SF1033560130142-5 | SF103356013077 | SF1033560106-1 |
Rating | ||||||
Price |
|
|
|
|
|
|
Stock | ||||||
Availability | ||||||
Add to cart | ||||||
Description | Shipped From Abroad
NEUROSTIM is a Transcranial Electrical Stimulator (TES) designed for neuromodulation, neuroprotection, and rehabilitation. It delivers precise electrical stimulation to targeted brain areas, aiding in motor cortex mapping, neurological recovery, and cognitive enhancement. Ideal for neurologists, neurosurgeons, and rehabilitation specialists, NEUROSTIM ensures safe, effective, and customizable stimulation for both clinical and research applications. With its advanced technology and user-friendly interface, it enhances treatment precision and patient outcomes in neuroscience and neurorehabilitation.
Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| Shipped From Abroad State-of-the-Art technology to measure ABI, TBI, Doppler, PVR, PPG and stress testing. Falcon advanced EMR and PACS capabilities and reporting options are designed for medical centers and private clinics alikeDelivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| Shipped From Abroad
The cutting-edge technology of the standalone Dolphin/4D transcranial Doppler system is the optimal TCD solution for measurements of cerebral blood flow velocities.
Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| Shipped From Abroad
State-of-the-Art technology to measure Segmental Blood Pressures, ABI, TBI, Doppler, PVR, PPG and stress testing. Falcon advanced EMR and PACS capabilities and reporting options are designed for medical centers and private clinics alike. Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| Shipped From Abroad
PSA Industrıal nitrogen generator systems produce gas nitrogen from compressed air from the field where they work, and switch compatible to conventional nitrogen gas source such as tubes or cryogenic liqiud.
Delivery & Availability:
Typically, 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| Shipped from abroad
The machine provides higher stimulus current, deeper cerebral stimulus penetration, and better seizure generalization. It provides the most effective form of bilateral brief pulse ECT with a 0.5msec pulsewidth that minimizes side-effects and can be delivered at every stimulus dose including the maximum dose with efficient and accurate stimulus titration.
|
Content | DC output current – up to 2mA
Neurostim is intended for the transcranial noninvasive stimulation with direct low current (up to 2 mA).
The current generates the electrical field changing the brain cortex excitability. Such brain impact has therapeutic effect in the treatment of different disorders including fibromyalgia, major depressive episode, addiction/craving, lower limb neuropathic pain and recovery of motor functions after stroke and brain injuries.
Continuous monitoring of electrode impedance
It is very important to keep the reliable skin-electrode contact during the whole stimulation procedure. Poor electrode contact due to improper electrode placement or dry-out can result in decreased therapeutic effect. Neurostim ensures continuous impedance monitoring. If the electrode impedance is too high, a notification will sound and the stimulation will be terminated (paused).
Two modes of use: inpatient and outpatient
For inpatient treatment Neurostim is supplied with pre-defined treatment protocols for most commonly used therapy. Just select the protocol for the particular patient from the list.
For outpatient treatment you should create a treatment course (up to 250 stimulation sessions). A patient will start the treatment sessions one by one. The completed session will be locked and cannot be used for the treatment.
USB connection for advanced control
The software can be used to control and adjust stimulator through USB. In this mode the stimulator is also powered through USB. The software is a simple way to manage the session list. You can add, remove, edit, import and export session, download user-defined waveform.
Features
Specifications
| https://youtu.be/YSWvhSIS1ho?si=rXtjG78U7PQgzrlf
Features of Falcon Physiologic Machine | https://youtu.be/Id0Ma1_lEo0?si=MmwcCTMMPZd_jf6h
Features of Dolphin TCD Machine | https://youtu.be/YSWvhSIS1ho?si=ZVl2aB_GXgSRotbP
Features of Falcon Physiologic Machine | PSA Industrıal nitrogen generator systems produce gas nitrogen from compressed air from the field where they work, and switch compatible to conventional nitrogen gas source such as tubes or cryogenic liqiud.
ADVANTAGES OF NITROGEN GENERATORS/PLANT
Wide Range Of Applications
![]() | The machine provides higher stimulus current, deeper cerebral stimulus penetration, and better seizure generalization. It provides the most effective form of bilateral brief pulse ECT with a 0.5msec pulsewidth that minimizes side-effects and can be delivered at every stimulus dose including the maximum dose with efficient and accurate stimulus titration.
Features-
Click Here To Download Catalogue |
Weight | N/A | N/A | N/A | N/A | N/A | N/A |
Dimensions | N/A | N/A | N/A | N/A | N/A | N/A |
Additional information |
Reviews
There are no reviews yet.