Non-Contact Tonometer
$7,150.00
Shipped From Abroad
Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Description
Non-Contact Tonometer air puff tonometer is a non contact tonometry machine for intraocular pressure (IOP) test. This machine is simple and easy to operate, and you can get test results within 10 seconds. Contactless measurement will reduce injuries or infections on eyes.
Product features of Non-Contact Tonometer:
NCT-100 air puff non-contact tonometer utilizes image control and feature recognition for auto 3-D positioning of x-y-z with reliable judgment and measurement results, and easy to operate. The air puff non-contact tonometer can be used to measure intraocular pressure (IOP) and corneal thickness.
Performance Features of Non-Contact Tonometer:
1. Auto 3-D positioning of x-y-z results in precise and reliable measurement.
2. Full-auto measurement for both right and left eye data without manual switch.
3. Easy to operate the tonometer with colour touch monitor.
4. Stable data of IOP through soft air measurement .
5. To compensate corneal thickness measurement of IOP.
Technical Specifications of Non-Contact Tonometer:
Intraocular pressure (IOP) measuring range | 1mmHg~30mmHg /1mmHg~60mmHg ( precision of 1mmHg) |
Measuring system | dual sensor system of light and pressure |
Working distance | ≥11mm |
R/L | automatic detection and display |
Measuring result | 10 times per eye; 3 times result printing per eye |
Recording | build-in printer |
Measuring mode | auto/manual |
Focus | when luminous spot is in the focus frame, 2 modes can be chosen.
auto mode: auto intraocular pressure measurement manual mode: when it’s good focus, the frame will turn yellow into green, and click to start the measurement |
Error indication | if the measurement signal is weak, the IOP will be enclosed by ( ), or display “ERR ” |
Safety limit button | install measurement for minimum distance between head and patient |
Safety functions | the distance between air nozzle and cornea
is controlled in preset range(such as 11mm); it will stop going forward when the cornea is too closed to air head. |
Movement range | ≥30mm(front to back)/ 90mm(left to right)/ 30mm(vertical) |
Jaw layer vertical movement | 0~65mm with under jaw layer |
Display mode | 10.1-inch HDMI color LED touch monitor |
Output port | USB2.0 |
Working platform | electric elevating platform |
Weight | 19.7kg |
size | 380 mm (L) x 460mm (W) x 505mm (H) |
Power supply | 220V/50HZ |
Quick Comparison
Settings | Non-Contact Tonometer remove | Pedal Bin remove | Nihon Kohden Neuropack S3 Electromyogram (EMG) Machine remove | Urine Analyzer remove | Hospital Trolley remove | OPTIKA B-382PL-ALC Binocular Brightfeld Microscope remove | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Name | Non-Contact Tonometer remove | Pedal Bin remove | Nihon Kohden Neuropack S3 Electromyogram (EMG) Machine remove | Urine Analyzer remove | Hospital Trolley remove | OPTIKA B-382PL-ALC Binocular Brightfeld Microscope remove | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Image | ![]() | ![]() | ![]() | ![]() | ![]() | ![]() | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
SKU | SF103356013027 | SF1033560084-201 | SF1033560020-3 | SF1033560084-224 | SF1033560084-237 | SF1033560098-13 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Rating | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Price | $7,150.00 | $17.00 |
| $540.00 | $48.00 |
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Stock | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Availability | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Add to cart | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Description | Shipped From Abroad
NCT-100 air puff tonometer is a non contact tonometry machine for intraocular pressure (IOP) test. This machine is simple and easy to operate, and you can get test results within 10 seconds. Contactless measurement will reduce injuries or infections on eyes.
Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| In stock
| Shipped from abroad The Neuropack S3 combines Nihon Kohden’s gold-standard amplifiers with time-saving and easy-to-use clinical software, bringing neurodiagnostic labs a feature-rich system that provides cleaner, easier and faster data. The foundation of effective neurodiagnostic testing is a system that can provide a full complement of neurodiagnostic tests while also offering the quality needed to analyze and monitor nervous system function. Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | In stock
Used for Clinical Diagnostics.
| In stock
Dimension (mm): L550 x W420 x H880 mm
Color: Grey
Material: Stainless steel
No of wheel: 4
| Shipped from Abroad The OPTIKA B-380 is an educational and laboratory microscope for routine applications. Dye-cast frame, with high stability and ergonomy, for transmitted light observation. Delivery & Availability: Typically 21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Content | Non-Contact Tonometer air puff tonometer is a non contact tonometry machine for intraocular pressure (IOP) test. This machine is simple and easy to operate, and you can get test results within 10 seconds. Contactless measurement will reduce injuries or infections on eyes.
Product features of Non-Contact Tonometer:
NCT-100 air puff non-contact tonometer utilizes image control and feature recognition for auto 3-D positioning of x-y-z with reliable judgment and measurement results, and easy to operate. The air puff non-contact tonometer can be used to measure intraocular pressure (IOP) and corneal thickness.
Performance Features of Non-Contact Tonometer:
1. Auto 3-D positioning of x-y-z results in precise and reliable measurement.
2. Full-auto measurement for both right and left eye data without manual switch.
3. Easy to operate the tonometer with colour touch monitor.
4. Stable data of IOP through soft air measurement .
5. To compensate corneal thickness measurement of IOP.
Technical Specifications of Non-Contact Tonometer:
|
| The Neuropack S3 combines Nihon Kohden’s gold-standard amplifiers with time-saving and easy-to-use clinical software, bringing neurodiagnostic labs a feature-rich system that provides cleaner, easier and faster data. The foundation of effective neurodiagnostic testing is a system that can provide a full complement of neurodiagnostic tests while also offering the quality needed to analyze and monitor nervous system function.
Features:
Click Here To Download Catalogue | Used for Clinical Diagnostics.
|
| Observation mode: Brightfield.
Head: Binocular, 30° inclined, 360° rotating (when ALC cable is unplugged).
Interpupillary distance: Adjustable between 48 and 75 mm.
Dioptric adjustment: On the left eyepiece tube.
Eyepieces: WF10x/20 mm, high eye-point and secured by screw.
Nosepiece: Quintuple revolving nosepiece, rotation on ball bearings.
Objectives:
N-PLAN 4x/0.10
N-PLAN 10x/0.25
N-PLAN 40x/0.65
N-PLAN 100x/1.25 (Oil/Water)
All with anti-fungus treatment.
Specimen stage: Double layer rackless mechanical stage, 150×139 mm, 75×33 mm X-Y range.
Focusing: Coaxial coarse (adjustable tension) and fine focusing mechanism with limit stop to prevent the contact between objective and specimen. Condenser: Abbe N.A. 1.25, with objective-coded iris diaphragm, focusable and centerable.
Illumination (Fixed Koehler type): X-LED3 with white 3.6 W LED (6,300K) and brightness control. ALC system. Multi-plug 100-240Vac/6Vdc external power supply.
Click Here To Download Catalogue | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Weight | N/A | N/A | N/A | N/A | N/A | N/A | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Dimensions | N/A | N/A | N/A | N/A | N/A | N/A | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Additional information |
Reviews