Non-Contact Tonometer

Ask for Price$0.00

Shipped From Abroad

NCT-100 air puff tonometer is a non contact tonometry machine for intraocular pressure (IOP) test. This machine is simple and easy to operate, and you can get test results within 10 seconds. Contactless measurement will reduce injuries or infections on eyes.

Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.

SF103356013027
Brands:: Vision Star

Description

Non-Contact Tonometer air puff tonometer is a non contact tonometry machine for intraocular pressure (IOP) test. This machine is simple and easy to operate, and you can get test results within 10 seconds. Contactless measurement will reduce injuries or infections on eyes.

Product features of Non-Contact Tonometer:
NCT-100 air puff non-contact tonometer utilizes image control and feature recognition for auto 3-D positioning of  x-y-z with reliable judgment and measurement results, and easy to operate. The air puff non-contact tonometer can be used to measure intraocular pressure (IOP) and corneal thickness.

Performance Features of Non-Contact Tonometer:
1. Auto 3-D positioning of x-y-z results in precise and reliable measurement.
2. Full-auto measurement for both right and left eye data without manual switch.
3. Easy to operate the tonometer with colour touch monitor.
4. Stable data of IOP through soft air measurement .
5. To compensate corneal thickness measurement of IOP.

Technical Specifications of Non-Contact Tonometer:

Intraocular pressure (IOP) measuring range 1mmHg~30mmHg /1mmHg~60mmHg ( precision of 1mmHg)
Measuring system dual sensor system of light and pressure
Working distance ≥11mm
R/L automatic detection and display
Measuring result 10 times per eye; 3 times result printing per eye
Recording  build-in printer
Measuring mode auto/manual
Focus when luminous spot is in the focus frame, 2 modes can be chosen.

auto mode: auto intraocular pressure measurement

manual mode: when it’s good focus, the

frame will turn yellow into green, and click

to start the measurement

Error indication if the measurement signal is weak, the IOP will be enclosed by ( ), or display “ERR ”
Safety limit button install measurement for minimum distance between head and patient
Safety functions the distance between air nozzle and cornea

is controlled in preset range(such as 11mm);

it will stop going forward when the cornea is

too closed to air head.

Movement range ≥30mm(front to back)/ 90mm(left to right)/ 30mm(vertical)
Jaw layer vertical movement 0~65mm with under jaw layer
Display mode 10.1-inch HDMI color LED touch monitor
Output port USB2.0
Working platform electric elevating platform
Weight 19.7kg
size 380 mm (L) x 460mm (W) x 505mm (H)
Power supply 220V/50HZ

Reviews

There are no reviews yet.

Be the first to review “Non-Contact Tonometer”

Your email address will not be published. Required fields are marked *

Quick Comparison

SettingsNon-Contact Tonometer removeKick About removeScrub Suit removeUrine Analyzer removeMedical Safety Google removeFeeding Table remove
NameNon-Contact Tonometer removeKick About removeScrub Suit removeUrine Analyzer removeMedical Safety Google removeFeeding Table remove
Image
SKUSF103356013027SF1033560084-238SF1033560084-202SF1033560084-224SF1033560084-196SF1033560084-195
Rating
Price

Ask for Price$0.00

$28.00

$11.00

$540.00

$1.99

$31.50

Stock
Availability
Add to cart

DescriptionShipped From Abroad
NCT-100 air puff tonometer is a non contact tonometry machine for intraocular pressure (IOP) test. This machine is simple and easy to operate, and you can get test results within 10 seconds. Contactless measurement will reduce injuries or infections on eyes.
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock
  • Supplied with one 35 cms. dia. S.S. Basin.
  • Stainless steel pipe construction mounted on three 10 cms. dia. castors.
Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock
  • V-neckline
  • Short raglan sleeves
  • Two pockets: one on the Top left and one on the right bottom.
  • Double stitch detail for durability
  • Side vents at hem
  • Customised polycotton fabric 
Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock Used for Clinical Diagnostics.
Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock
Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock
  • Strong wooden top.
  • With Casters for easy movement.
Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Content Non-Contact Tonometer air puff tonometer is a non contact tonometry machine for intraocular pressure (IOP) test. This machine is simple and easy to operate, and you can get test results within 10 seconds. Contactless measurement will reduce injuries or infections on eyes. Product features of Non-Contact Tonometer: NCT-100 air puff non-contact tonometer utilizes image control and feature recognition for auto 3-D positioning of  x-y-z with reliable judgment and measurement results, and easy to operate. The air puff non-contact tonometer can be used to measure intraocular pressure (IOP) and corneal thickness. Performance Features of Non-Contact Tonometer: 1. Auto 3-D positioning of x-y-z results in precise and reliable measurement. 2. Full-auto measurement for both right and left eye data without manual switch. 3. Easy to operate the tonometer with colour touch monitor. 4. Stable data of IOP through soft air measurement . 5. To compensate corneal thickness measurement of IOP. Technical Specifications of Non-Contact Tonometer:
Intraocular pressure (IOP) measuring range 1mmHg~30mmHg /1mmHg~60mmHg ( precision of 1mmHg)
Measuring system dual sensor system of light and pressure
Working distance ≥11mm
R/L automatic detection and display
Measuring result 10 times per eye; 3 times result printing per eye
Recording  build-in printer
Measuring mode auto/manual
Focus when luminous spot is in the focus frame, 2 modes can be chosen. auto mode: auto intraocular pressure measurement manual mode: when it’s good focus, the frame will turn yellow into green, and click to start the measurement
Error indication if the measurement signal is weak, the IOP will be enclosed by ( ), or display “ERR ”
Safety limit button install measurement for minimum distance between head and patient
Safety functions the distance between air nozzle and cornea is controlled in preset range(such as 11mm); it will stop going forward when the cornea is too closed to air head.
Movement range ≥30mm(front to back)/ 90mm(left to right)/ 30mm(vertical)
Jaw layer vertical movement 0~65mm with under jaw layer
Display mode 10.1-inch HDMI color LED touch monitor
Output port USB2.0
Working platform electric elevating platform
Weight 19.7kg
size 380 mm (L) x 460mm (W) x 505mm (H)
Power supply 220V/50HZ
  • Supplied with one 35 cms. dia. S.S. Basin.
  • Stainless steel pipe construction mounted on three 10 cms. dia. castors.
  • V-neckline
  • Short raglan sleeves
  • Two pockets: one on the Top left and one on the right bottom.
  • Double stitch detail for durability
  • Side vents at hem
  • Customised polycotton fabric 
 
  • Category: Doctor General Wear, Nurse Wear, Attendant Wear, Hospital Staff Wear, Ot Room Wear
  •  Color: Blue, Green, Magenta , Light Teal, Light Green, Sky blue, Ocean blue, Coral Pink
  •  Size: Small, Medium, Large, XL, XXL
  •  Gender: Male
  •  Material: Polycotton
  •  Sleeve Type: Half
  •  Pattern: Closed
  •  Disposable: No
  •  Neck Type: "V" Neck
  • Wash Care: Do Not Bleach, Machine Wash, Hand Wash
 
Used for Clinical Diagnostics.
  • Test Method: Dry Strip color-developing method
  • Test Principle: Dual wavelength reflectance photometry
  • Light Source: Cold Lamp with high brightness and long lifetime
  • Test System: Color-indentify system with high sensitivity and repeatability
  • Wavelength: 520nm, 640nm, 660nm
  • Throughput: 120 Strips/Hour
  • Test Mode: Single and continuous test mode are selectable
  • Test Slot: Using sliding Slot, Easy to clean and replace, lower the carryover
  • Waste Collection: Waste urine and waste strips can be collected automatically
  • Test Strip: Use GENIUS original strips only
  • Display: LCD with high brightness and resolution
  • Language: Customizable language software
  • Memory: Save 2000 samples results, and auto recover the results when power off during working
  • Interface: RS-232 serial port, can be connected to external printer and computer Printer: Inner thermal printer, can be connected to external printer
  • Report format: Half quantitative and qualitative, report the color and turbidity is available
  • Result unit: SI unit and routine unit are selectable
  • Status Check: Auto-check the status during power on and off, auto-indentify the alarm
  • Working Environment: Temperature10℃~30℃; Humidity: 20%RH~80%RH
  • Power: 100-240V, Auto adapt according to the input voltage
  • Consumption: ≤80VA
  • Quality System: Certified by TUV and CMD
  • Strong wooden top.
  • With Casters for easy movement.
WeightN/AN/AN/AN/AN/AN/A
DimensionsN/AN/AN/AN/AN/AN/A
Additional information
Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • Rating
  • Price
  • Description
Click outside to hide the comparison bar
Compare