Oxygen is generated from clean, dry, and compressed air by a separation process which uses the principle of selective adsorption. The air is passed through a bed of Zeolite Molecular Sieves which has a property of a very high degree of affinity to nitrogen. The Zeolite contains an infinite number of micropores and it retains the adsorbed nitrogen molecules in these pores.
Before this process is affected, the compressed air has to be purified by removing all contaminants i.e. solids, condensed liquids, and oil & water vapors by passing it through a Prefilter. Oil Removal Filter (not required if oil-free Compressor is used) and Air Dryer.
The dry & oil-free air from Air Dryer is stored in a Dry Air Receiver before it enters the PSA System. In this System, there are two adsorbers filled with ZMS, where nitrogen along with any traces of moisture, are adsorbed and product gas (dry oxygen) comes out and passes to the Oxygen Surge Vessel. In the PSA System, one adsorber is in the production cycle while the other is regenerated (desorbed) by depressurization.
The two adsorbers keep switching from adsorption to desorption automatically, through a sequence timer. The pressure in the adsorbers swings from atmospheric pressure to line pressure, which is why this process is known as Pressure Swing absorption (PSA).
Includes:
Oil Screw Air Compressor @ 7,5bar
Compressed Air Tank ( Max 16Bar ) with Drain Valve
Line Filter ( WS )
Line Filter ( P : 3 mic / — mg/m3 )
Line Filter ( X : 0.1 mic / 0.1 mg/m3 )
Dryer ( Refrigerant Type / +3˚C )
Line Filter ( Y : 0.1 mic / 0.01 mg/m3 )
Line Filter ( AC : — mic / 0.003 mg/m3 )
O2 Generator ( PSA )
* 2 molecular sieve beds,
* 1 pneumatic equipment
* 1 electrical equipment
Main technical data :
… produced oxygen flow
… produced oxygen concentration level : % 95 ~ +/- 1
… produced oxygen pressure level: 4.5 – 6 bar
Galvanized O2 Storage Tank ( Max 16 Bar )
Connection Equipment
Optional Equipment:
O2 Cylinder Filling High Pressure Compressor
Cylinder Manifold Station
Quick Comparison
Settings | O2 Generating Systems remove | ASPEL AsCARD Grey ECG Machine remove | Sonoscape E2 Ultrasound Machine remove | Sonoscape E1 Ultrasound Machine With Two Probes remove | ASPEL AsCARD Green ECG Machine remove | ASPEL Stress ECG with Treadmill and Software remove |
---|---|---|---|---|---|---|
Name | O2 Generating Systems remove | ASPEL AsCARD Grey ECG Machine remove | Sonoscape E2 Ultrasound Machine remove | Sonoscape E1 Ultrasound Machine With Two Probes remove | ASPEL AsCARD Green ECG Machine remove | ASPEL Stress ECG with Treadmill and Software remove |
Image | ![]() | ![]() | ![]() | ![]() | ![]() | ![]() |
SKU | SF1033560075-5 | SF1033560012-17 | SF1033560012-20 | SF1033560075-9 | SF1033560075-2 | |
Rating | ||||||
Price |
| $1,166.00 | $5,500.00 | $4,620.00 |
| $6,542.00 |
Stock | ||||||
Availability | ||||||
Add to cart | ||||||
Description | Shipped From Abroad
Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| Shipped from Abroad Electrocardiograph AsCARD Grey v.07.225 - is a 1, 3, 6, 12 channel ECG unit which enables to make electrocardiogram in full 12 leads. It is intended to conduct ECG examinations of adults and paediatric patients in all types of health care centres. ECG examination may be recorded in manual or automatic mode, with the possibility of analysis and interpretation. The device can be powered from 100 V ÷ 240 V mains supply or by an internal battery. Delivery & Availability: Typically 10 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | Shipped from Abroad Sonoscape E2 portable ultrasound machine is a color Doppler ultrasound system that reaches beyond your expectations due to its compact and fashionable appearance. It fulfills GI, OB/GYN, Cardiac and POC applications to fit your routine scanning needs while its color mode will help you for more accurate and efficient diagnosis of lesions. E2 provides a wide range of applications to assist users with routine scanning. E2 provides automatic calculations to enhance your diagnostic confidence and save you time for patient communication. Delivery & Availability: Typically 14 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | Shipped from Abroad SonoScape has developed a new probe and function for the E1 Exp. With these additions the E1 Exp will bring users a more efficient examination experience with satisfying image quality and a smooth workflow. Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | Shipped from Abroad AsCARD Green v.06.101 is a 1-, 3-, 6- and 12-channel ECG unit which enables to make electrocardiogram in full 12 leads. Intended for ECG examinations of adult and paediatric patients aimed at identification of cardiological abnormalities, myocardial ischaemia or infarction. The device is intended for use in healthcare facilities by duly trained personnel. ECG examination may be recorded in manual or automatic mode with the ability to perform the analysis and interpretation. Delivery & Availability: Typically 10 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | Shipped from Abroad It is a system with professional tool dedicated to exercise and resting ECG examination. Treadmill has 12 lead ECG modules. With ECG Analyzing Software. Delivery & Availability: Typically 21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. |
Content | Oxygen is generated from clean, dry, and compressed air by a separation process which uses the principle of selective adsorption. The air is passed through a bed of Zeolite Molecular Sieves which has a property of a very high degree of affinity to nitrogen. The Zeolite contains an infinite number of micropores and it retains the adsorbed nitrogen molecules in these pores. Before this process is affected, the compressed air has to be purified by removing all contaminants i.e. solids, condensed liquids, and oil & water vapors by passing it through a Prefilter. Oil Removal Filter (not required if oil-free Compressor is used) and Air Dryer. The dry & oil-free air from Air Dryer is stored in a Dry Air Receiver before it enters the PSA System. In this System, there are two adsorbers filled with ZMS, where nitrogen along with any traces of moisture, are adsorbed and product gas (dry oxygen) comes out and passes to the Oxygen Surge Vessel. In the PSA System, one adsorber is in the production cycle while the other is regenerated (desorbed) by depressurization. The two adsorbers keep switching from adsorption to desorption automatically, through a sequence timer. The pressure in the adsorbers swings from atmospheric pressure to line pressure, which is why this process is known as Pressure Swing absorption (PSA).Includes:Oil Screw Air Compressor @ 7,5bar Compressed Air Tank ( Max 16Bar ) with Drain Valve Line Filter ( WS ) Line Filter ( P : 3 mic / — mg/m3 ) Line Filter ( X : 0.1 mic / 0.1 mg/m3 ) Dryer ( Refrigerant Type / +3˚C ) Line Filter ( Y : 0.1 mic / 0.01 mg/m3 ) Line Filter ( AC : — mic / 0.003 mg/m3 ) O2 Generator ( PSA ) * 2 molecular sieve beds, * 1 pneumatic equipment * 1 electrical equipment Main technical data : … produced oxygen flow … produced oxygen concentration level : % 95 ~ +/- 1 … produced oxygen pressure level: 4.5 – 6 bar Galvanized O2 Storage Tank ( Max 16 Bar ) Connection EquipmentOptional Equipment:O2 Cylinder Filling High Pressure Compressor Cylinder Manifold Station |
Electrocardiograph AsCARD Grey v.07.225 - is a 1, 3, 6, 12 channel ECG unit which enables to make electrocardiogram in full 12 leads. It is intended to conduct ECG examinations of adults and paediatric patients in all types of health care centres. ECG examination may be recorded in manual or automatic mode, with the possibility of analysis and interpretation. The device can be powered from 100 V ÷ 240 V mains supply or by an internal battery.
Technical Specification:1. Visualisation of 1, 3, 6 or 12 ECG waveforms, analysis results and interpretations, examinations stored in memory.
2. Recording of 12 standard leads.
3. Print out in 1, 3, 6 or 12 ECG waveforms mode. Printing of a selected group:
Click Here To Download Catalogue | SONOSCAPE E2 DETAILS
Auto Image Optimization
A portable ultrasound machine with the press of a button, the image is automatically adjusted and optimized, saving you time with parameter adjustments. Additionally, with Auto Focus on, the focus area follows the depth of the ROI box as it is moved in the scanning field, providing users with excellent image quality in the desired area of interest.
Automated Calculation
Auto IMT is used when determining the level of vascular sclerosis present in the patient by automatically tracing the thickness of the carotid vessels.
Auto trace provides users sensitive and accurate wave tracing, avoiding the error of manual trace and giving out calculation result in no time
In-Build Battery pack
This portable ultrasound machine was equipped with an in-build battery pack which enable the user to perform image scanning when AC power is not available.
Click Here To Download Catalogue | DETAILS
Efficient Diagnosis
μ-Scan, Speckle Reduction & Edge Enhancement
Spatial Compound Imaging
PIH - Pure Inversion Harmonic
Wide Scan - Enlarged Image Area
Tissue-Specific Imaging
SR Flow
Ergonomic Designs
Up to 2 Transducer Ports
Light Weight and Compact
15.6 inch Anti-flickering HD LED Screen
Tilting Monitor Angle Adjustment
Backlit Keyboard and Intelligent Panel
Long-lasting Battery for 90 mins
Ease of Use
Quick Boot Up
Auto-Brightness Adjustment
Auto Image Optimization
Auto IMT
Auto Trace
Equipped Accessories
Wi-Fi and Bluetooth Available
DICOM
500GB Hard Disk
Height Adjustable Trolley
Durable, Carry-on Site Suitcase
Click Here To Download Catalogue | AsCARD Green v.06.101 is a 1-, 3-, 6- and 12-channel ECG unit which enables to make electrocardiogram in full 12 leads. Intended for ECG examinations of adult and paediatric patients aimed at identification of cardiological abnormalities, myocardial ischaemia or infarction. The device is intended for use in healthcare facilities by duly trained personnel. ECG examination may be recorded in manual or automatic mode with the ability to perform the analysis and interpretation.
Electrocardiograph is based on advanced microprocessor technology .It is equipped with a thermal printer with high-resolution head and 4,3" LCD display. A touch panel and high-tech membrane keyboard makes this device intuitive in usage and its menu navigation exceptionally easy. This light-weight, small-footprint and battery powered cause that device can be easily transported to any location. With plastic casing and foil covered keyboard, the device is neat and easy to clean.
Technical Specifications:
Click Here To Catalogue Download | It is a system with professional tool dedicated to exercise and resting ECG examination. Treadmill has 12 lead ECG modules. With ECG Analyzing Software.
Technical Specification:
Click Here To Download Catalogue |
Weight | N/A | N/A | N/A | N/A | N/A | N/A |
Dimensions | N/A | N/A | N/A | N/A | N/A | N/A |
Additional information |