OBS-50 High Frequency Coagulator

$0.00

Shipped From Abroad

This unit is widely used in many different sectors including plastic surgery, dermatology, ENT, Ophthalmology, somatology, gynecology, proctology, and urology.

Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
SF1033560130165-3
Brands:: OBS

Description

 

The OBS-50 is a market leader across the world due to its ease of use, high security, power on self test, full-range monitoring, remote control and precise output.

  • Power output can be controlled by the easy to use power adjustment button on the electrosurgical hand pencil which can shorten the operation time.
  • With the inbuilt memory function on the device, you can set the required function parameters then power off the unit, next time the unit is powered on, the unit the last set parameter will be displayed.
  • Output power of between 10 and 30 watts or less can be adjusted up and down by 0.1-watt increments, which is suitable for various delicate procedures.
  • It can be used with disposable dispersive electrode

 What’s in the box?

  • x1 OBS-50 High-Frequency Electric Coagulator Unit
  • x1 Reusable power control electrosurgical pencil
  • x10 Non-Sterile Single-Use Short Sharp Tips
  • x10 Non-Sterile Single-Use Short Blunt Tips
  • x1 Power cord
  • x1 Instruction manual
Multiple Applications to meet your different clinic demands

Desiccation 

  • Monopolar output mode without using the dispersive electrode
  • Contact or insert into the tissue with the electrode
  • The unit produces a high-frequency current, which runs through the patient via the electrode and then returns to the unit through grounding.
  • High-frequency current vaporises the liquid inside the tissue cell therefore causing denaturation on the protein

Fulguration

  • Another monopoly output mode without using a dispersive electrode
  • Holding the electrode above the lesions rather than contact directly, will release an electric arc to the tissue.
  • Range of action in this mode is limited to the surface where the arc contacts the tissue

Coagulation

  • Suitable for hemostasis and shrinkage of tissue
  • Used in control of hemostasis
  • Suitable for more difficult cutting procedures for good hemostasis

Monopolar coagulation

  • Monopolar output mode using the dispersive electrode
  • Under this mode, the high-frequency current that is produced from the unit flows through the patient and then returns to the unit via a dispersive electrode
  • The dispense electrode can draw more high-frequency current to the electrode, making the tip of electrode produce a more powerful desiccation to the tissue.

Bipolar Coagulation

  • An Output mode in which the high-frequency current circulates between two nearby electrodes (bipolar forceps), without using the dispersive electrode.
  • In contrast to the effect of monopolar coagulation, since the high-frequency current is only circulated separately in the forceps, the bipolar coagulation effect acts only on the tissue surface, causing minimal damage to the tissue.

Standard Accessories (Can be purchased Separately)

  • Single foot switch
  • Reusable power control electrosurgical pencil
  • Reusable dispersive electrode (Patient Plate) & Cable
  • Reusable bipolar forceps & cable
  • Reusable Connecting Cable (for disposable dispersive electrode)
  • Disposable dispersive electrodes
  • Wall mounting Plate

Output Mode 

Monopolar coagulation: (30W, load:1000Ω)

Bipolar coagulation: (30W, load:200Ω)

Technical parameters

Ambient Temperature  10°C – 40°C
RH Range ≤80%
atmospheric pressure range 50.0kPa-106.0kPa
Power supply 220/110V,50/60Hz
operating Frequency 550kHz+10%

Reviews

There are no reviews yet.

Be the first to review “OBS-50 High Frequency Coagulator”

Your email address will not be published. Required fields are marked *

Quick Comparison

SettingsOBS-50 High Frequency Coagulator removeElectrosurgical Bipolar Forceps removeDisposable Electrosurgical Pencil removeOBS-100C(II) Cold RF Unit removeSS-100 Smoke Evacuation System removeOBS-100B Cold Bipolar Coagulator remove
NameOBS-50 High Frequency Coagulator removeElectrosurgical Bipolar Forceps removeDisposable Electrosurgical Pencil removeOBS-100C(II) Cold RF Unit removeSS-100 Smoke Evacuation System removeOBS-100B Cold Bipolar Coagulator remove
Image
SKUSF1033560130165-3SF1033560130165-18SF1033560130165-10SF1033560130165-6SF1033560130165-9SF1033560130165-8
Rating
Price

$0.00

$0.00

$0.00

$0.00

$0.00

$0.00

Stock
Availability
Add to cart

DescriptionShipped From Abroad This unit is widely used in many different sectors including plastic surgery, dermatology, ENT, Ophthalmology, somatology, gynecology, proctology, and urology.
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad Electrosurgical Bipolar Forceps are specialized surgical instruments used in electrosurgery. They have two electrodes at the tips, which allow for precise control of electrical current to coagulate, cut, or seal tissue with minimal damage to surrounding areas.
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad A Disposable Electrosurgical Pencil is a single-use tool used in surgery to cut and cauterize tissue. It features an ergonomic design for easy handling and comes with various electrode tips to suit different surgical needs. It ensures patient safety by being sterile and disposable.
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad OBS-100C(II) uses high-frequency radio wave technology as an energy source to cut and coagulate soft tissue. it operates at 3.8MHz, enabling a precise incision with significantly less heat and resultant heat damage than typically found with conventional electrosurgery. Since tissue stays cooler with high-frequency radio wave technology, you can feel confident that you are minimizing cellular destruction along the incision path.
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad

The SS-100 Smoke Evacuation System is designed to protect medical staff and patients from harmful surgical smoke generated during electrosurgical procedures

Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad The OBS-100B Cold Bipolar Coagulator is a precision electrosurgical device designed for delicate surgeries. It ensures minimal tissue irritation, offers a non-stick effect, and operates without sparking, making it ideal for microsurgical applications like neurosurgery and ophthalmology.
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Content   The OBS-50 is a market leader across the world due to its ease of use, high security, power on self test, full-range monitoring, remote control and precise output.
  • Power output can be controlled by the easy to use power adjustment button on the electrosurgical hand pencil which can shorten the operation time.
  • With the inbuilt memory function on the device, you can set the required function parameters then power off the unit, next time the unit is powered on, the unit the last set parameter will be displayed.
  • Output power of between 10 and 30 watts or less can be adjusted up and down by 0.1-watt increments, which is suitable for various delicate procedures.
  • It can be used with disposable dispersive electrode
 What's in the box?
  • x1 OBS-50 High-Frequency Electric Coagulator Unit
  • x1 Reusable power control electrosurgical pencil
  • x10 Non-Sterile Single-Use Short Sharp Tips
  • x10 Non-Sterile Single-Use Short Blunt Tips
  • x1 Power cord
  • x1 Instruction manual
Multiple Applications to meet your different clinic demands
Desiccation 
  • Monopolar output mode without using the dispersive electrode
  • Contact or insert into the tissue with the electrode
  • The unit produces a high-frequency current, which runs through the patient via the electrode and then returns to the unit through grounding.
  • High-frequency current vaporises the liquid inside the tissue cell therefore causing denaturation on the protein
Fulguration
  • Another monopoly output mode without using a dispersive electrode
  • Holding the electrode above the lesions rather than contact directly, will release an electric arc to the tissue.
  • Range of action in this mode is limited to the surface where the arc contacts the tissue
Coagulation
  • Suitable for hemostasis and shrinkage of tissue
  • Used in control of hemostasis
  • Suitable for more difficult cutting procedures for good hemostasis
Monopolar coagulation
  • Monopolar output mode using the dispersive electrode
  • Under this mode, the high-frequency current that is produced from the unit flows through the patient and then returns to the unit via a dispersive electrode
  • The dispense electrode can draw more high-frequency current to the electrode, making the tip of electrode produce a more powerful desiccation to the tissue.
Bipolar Coagulation
  • An Output mode in which the high-frequency current circulates between two nearby electrodes (bipolar forceps), without using the dispersive electrode.
  • In contrast to the effect of monopolar coagulation, since the high-frequency current is only circulated separately in the forceps, the bipolar coagulation effect acts only on the tissue surface, causing minimal damage to the tissue.
Standard Accessories (Can be purchased Separately)
  • Single foot switch
  • Reusable power control electrosurgical pencil
  • Reusable dispersive electrode (Patient Plate) & Cable
  • Reusable bipolar forceps & cable
  • Reusable Connecting Cable (for disposable dispersive electrode)
  • Disposable dispersive electrodes
  • Wall mounting Plate
Output Mode  Monopolar coagulation: (30W, load:1000Ω) Bipolar coagulation: (30W, load:200Ω) Technical parameters
Ambient Temperature  10°C - 40°C
RH Range ≤80%
atmospheric pressure range 50.0kPa-106.0kPa
Power supply 220/110V,50/60Hz
operating Frequency 550kHz+10%
 
Features:
  1. Two Electrodes: The tips of the forceps act as both the active and return electrodes.
  2. Precision Control: Allows for targeted application of electrical energy.
  3. Reduced Risk of Burns: The current is confined between the forceps, minimizing the risk of accidental burns.
  4. Reusable: Often made from stainless steel or titanium and can be sterilized for multiple uses.
  5. Variety of Designs: Available in straight, angled, and bayonet styles to suit different surgical needs.
Uses:
  1. Coagulation: Used to stop bleeding by coagulating blood vessels.
  2. Tissue Cutting: Can be used to cut tissue with precision.
  3. Sealing: Effective in sealing blood vessels and tissue bundles.
  4. Versatility: Used in various surgical fields such as general surgery, gynecology, neurosurgery, and ENT (Ear, Nose, and Throat) surgery.
Features
Handswitching pencils are available with either push-button or rocker switch controls to accommodate the surgeon's preference. Switches have a high level of tactile feedback - surgeons can hear and feel the switch engage, preventing accidental activation of the device.
  • Designed with the surgeon in mind
  • Slim and lightweight, tapered ergonomic design, streamlined design.
  • Slip-proof handling and water resistant Rocker or Push-Button Switch
  • Switch and buttons designed for smooth activation
  • Equipped with a range of monopolar cutting and coagulation electrodes to satisfy all users requirements.
  • With hexagonal shape to protect against inadvertent twisting, the electrodes can be locked safely into place and are easily exchanged and replaced.
Experts have identified harmful smoke which contains a variety of toxic gases and vapors will occur during electrosurgical operation. Medical staff and patients exposure to the smoke in large may cause viral contamination,respiratory problems,nausea and burning eyes.To use a smoke evacuation system is the most effective way of protecting operating room staff and patients from hazards.
 
Features
  • Effective smoke removal: Captures toxic gases and vapors.
  • Compact and portable: Weighs 3.5 kg with a trolley cart for easy mobility.
  • Quiet operation: Works at 55 dB.
  • High efficiency: Processes 3.5-4.2 cubic meters of smoke per hour.
  • Automatic startup: Can be activated by an internal sensor or foot switch
 
Features
  • Low voltage output: Ensures minimal irritation to neuromuscular tissues.
  • Sparkless operation: Reduces tissue sticking.
  • Superb non-stick effect: Enhances surgical precision.
  • Suitable for microsurgery: Ideal for neurosurgery, ophthalmology, gynecology, and plastic surgery
 
WeightN/AN/AN/AN/AN/AN/A
DimensionsN/AN/AN/AN/AN/AN/A
Additional information
Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • Rating
  • Price
  • Description
Click outside to hide the comparison bar
Compare