Optika B-293LD1.50 Trinocular LED Fluorescence Microscope

$0.00

Shipped from Abroad

Fluorescence binocular and trinocular microscopes especially designed for tubercolosis and malaria analysis.

Delivery & Availability:
Typically 21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.

SF1033560098-7
Brands:: Optika
Brands

Description

Fluorescence binocular and trinocular microscopes especially designed for tubercolosis and malaria analysis.

Features: 

  • Observation mode: Brightfield.
  • Head: Trinocular, 360° rotating and 30° inclined. Interpupillary distance 48-75mm.
  • Dioptric adjustement: On the left eyepiece tube.
  • Eyepieces: WF10x/20 mm, high eye-point and secured by a screw.
  • Nosepiece: Quadruple revolving nosepiece, rotation on ball bearings.
  • Objectives:
    Equipped with binocular head and following objectives:
    IOS N-PLAN 10x/0.25 (Cover/No Cover), with anti-fungus treatment
    IOS N-PLAN 20x/0.40 (Cover/No Cover), with anti-fungus treatment
    IOS N-PLAN 40x/0.65 (Cover/No Cover), with anti-fungus treatment
    IOS W-PLAN MET 50x/0.75 (No Cover), with anti-fungus treatment
  • Specimen stage: Double layer rackless mechanical sliding stage, 150×139 mm, 75×33 mm X-Y movement range. Vernier scale on the two axes, accuracy: 0.1 mm.
  • Focusing: Coaxial coarse and fine focusing mechanism with limit stop to prevent the contact between objective and specimen. Adjustable tension of coarse focusing knob.
  • Condenser: Abbe N.A. 1.25, with objective-coded iris diaphragm, focusable and centerable.
  • Brightfield Illumination (Fixed Koehler type): X-LED3 with white 3.6 W LED (6,300 K) and light intensity control. Multi-plug 100-240Vac/6Vdc external power supply.
  • Fluorescence Illumination: Extra efficiency LED, with light intensity control. Peak wavelength: 465 nm, Power: 3.6W.
  • Epi Fluorescence Attachment: Slider with 3 positions (2 fluorescence, 1 brightfield), with 1 included filterset: Fluorescence B: EX 460-490, DM 505, EM 515LP: Acridine Yellow, Acridine Orange, Auramine, DiO, DTAF, FITC, GFP, YFP, etc.

 

Technical Specifications:

Observation Method –

Transmitted Light

Brightfield Yes
  Phase contrast (Positive type) As optional
  Darkfield As optional
  Simple polarized light As optional
Observation Method –

Incident Light

Fluorescence Yes
Main Body Type Upright
  Construction material Aluminum die-cast
  Trasportation handle Yes
Head Type Trinocular (Siedentopf)
  Split ratio 50/50
  Inclination 30°
  360° rotating Yes
  Interpupillary distance (mm) 48-75
  Dioptric adjustement On left tube
  Fixing screw for eyepieces Yes
  Tube inner diameter (mm) 23
Eyepieces Field number (mm) 20
  Magnification 10x
  Pointer As optional
  Micrometric scale As optional
  Diameter of micrometer glass (mm) 21
  High eyepoint (for glass wearers) Yes
  Rubber cup Yes
Nosepiece Positions Quadruple
  Bi-directional Yes
  Rotation on ball bearings Yes
  Objective thread RMS
Objectives Optical system
  Anti-fungus treatment Yes
  Parfocal distance (mm) 45
  Standard magnifications 40x-400x
  Type IOS
  Objectives included OS N-PLAN

10x/0.25, W.D. 5.8 mm

IOS N-PLAN

20x/0.40, W.D. 5.1 mm

IOS N-PLAN

40x/0.65, W.D. 0.43 mm

IOS W-PLAN MET

50x/0.75, W.D. 0.32 mm

Stage Type Double layer
  Dimensions (mm) 150×139
  Moving mechanism Rackless
  Moving range (mm) 75×33
  Material Anti-scratch painting
  Specimen holder Yes
  Slide number 1
  X-Y Vernier scale Yes
  Vernier scale accuracy (mm) 0.1
Condenser – Single

Position

Type Abbe
  Removable Yes
  Numerical aperture (N.A.) 1.25
  Magnification scale for simplified positioning Yes
  Diaphragms Iris
  Centrable Yes
  Focusable By rack and pinion
Focusing System Type Coaxial coarse & fine
  Coarse total travel (mm) 18
  Fine total travel (per single rotation) (mm) 0.4
  Fine graduations 100
  Fine resolution (µm) 4
  Upper stop to prevent contact Yes
  Adjustable tension Yes
Transmitted

Illumination

Kohler illumination Fixed
  Type X-LED
  X-LED type X-LED3
  Light source power (W) 3.6
  Brightness control Manual
  Lifetime (hours) > 65,000
  Temperature (K) 6,300
  Max. required power (W) 6
Power Supply for

Transmitted

Illumination

Type External
  Microscope connector Jack, 2.1 mm
  Power plug type Multi-plug (EU, UK, US)
  Input voltage 100/240 Vac, 50/60 Hz
  Output voltage 6 Vdc  2.5A
Accessories Included Dust cover Yes
  Immersion oil (10ml) Yes
  Tension adjustment tool Yes
  User Manual Digital version (downloadable)
Additional Information Mirror for transmitted light (as optional).

External rechargeable battery pack (as optional)

Product Weight Height (mm) 515
  Width (mm) 235
  Depth (mm) 340
Product Weight (kg) 7.5
Fluorescence

Attachment

Number of positions 3
  Blue filter set (included) specs Excitation: 460 – 490 nm; Dichroic: 505 nm;

Emission: 515LP nm

  Filter dimensions Excitation: 18 mm diam.;

Dichroic: 26.5 mm x 19 mm;

Emission: 18 mm diam.

  Filter set selection Manual
Fluorescence Light

Source

Light source Blue LED
  Watt (W) 3.6
  LED wavelength Blue LED: 465 nm
  Lifetime (hours) > 65,000
  Brightness control Yes

Reviews

There are no reviews yet.

Be the first to review “Optika B-293LD1.50 Trinocular LED Fluorescence Microscope”

Your email address will not be published. Required fields are marked *

Quick Comparison

SettingsOptika B-293LD1.50 Trinocular LED Fluorescence Microscope removeiSED Fully Automated ESR Analyzer removeEppendorf Pipette Tip 200ul Per Pack removeTest Strip for ApexBio HemoSmart Gold Hemoglobin Meter removeEppendorf Pipette Tip 20ul Per Pack removeSkyla HB1 POC Clinical Chemistry Auto Analyzer remove
NameOptika B-293LD1.50 Trinocular LED Fluorescence Microscope removeiSED Fully Automated ESR Analyzer removeEppendorf Pipette Tip 200ul Per Pack removeTest Strip for ApexBio HemoSmart Gold Hemoglobin Meter removeEppendorf Pipette Tip 20ul Per Pack removeSkyla HB1 POC Clinical Chemistry Auto Analyzer remove
ImageOptika B-293LD1.50 Trinocular LED Fluorescence MicroscopeEppendorf Pipette Tip 200ul Per PackEppendorf Pipette Tip 20ul Per Pack
SKUSF1033560098-7SF1033560084-129SF1033560084-137SF1033560084-30SF1033560084-136SF1033560060-1
Rating
Price

$0.00

$0.00

$0.00

$9.50

$0.00

$0.00

Stock
Availability
Add to cart

DescriptionShipped from Abroad Fluorescence binocular and trinocular microscopes especially designed for tubercolosis and malaria analysis.
Delivery & Availability: Typically 21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock
The technical innovation of the iSED® fully-automated ESR analyzer consists of directly measuring the intensity of the red cell aggregation which is responsible for Erythrocyte Sedimentation Rate (ESR). Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock
  • Made of high quality PP material with good transparency.
  • Applied for Gilson/Finland/Eppendorf Pipettors.
  • Carefully inspect of raw material and manufactured under strict process check, all tips are with excellent accuracy and precison.
  • Special siliconizing on the inner surface ensure no liquid adhesion and accurate sample transfer.
  • Standard tips and filter tips can be autoclaved, high temperature sterilization acceptable.
Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In Stock Twenty Five (25) Test Strip per Pack

Delivery & Availability:

Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock
  • Made of high quality PP material with good transparency.
  • Applied for Gilson/Finland/Eppendorf Pipettors.
  • Carefully inspect of raw material and manufactured under strict process check, all tips are with excellent accuracy and precison.
  • Special siliconizing on the inner surface ensure no liquid adhesion and accurate sample transfer.
  • Standard tips and filter tips can be autoclaved, high temperature sterilization acceptable.
Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped from Abroad The skyla HB1 Clinical Chemistry Analyzer provides clinical testing laboratories of medical facilities and clinics with an in-vitro clinical chemistry diagnostic tool that is compact, portable, and reports rapid results. The portable design of the clinical chemistry analyzer utilizes precision photometric measurement technology, combined with the single-use disposable reagent discs. The reagent disc contains a set of dry assay reagents that are used in the quantitative testing of various biomarkers in the blood sample. Delivery & Availability: Typically 14 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
ContentFluorescence binocular and trinocular microscopes especially designed for tubercolosis and malaria analysis. Features: 
  • Observation mode: Brightfield.
  • Head: Trinocular, 360° rotating and 30° inclined. Interpupillary distance 48-75mm.
  • Dioptric adjustement: On the left eyepiece tube.
  • Eyepieces: WF10x/20 mm, high eye-point and secured by a screw.
  • Nosepiece: Quadruple revolving nosepiece, rotation on ball bearings.
  • Objectives: Equipped with binocular head and following objectives: IOS N-PLAN 10x/0.25 (Cover/No Cover), with anti-fungus treatment IOS N-PLAN 20x/0.40 (Cover/No Cover), with anti-fungus treatment IOS N-PLAN 40x/0.65 (Cover/No Cover), with anti-fungus treatment IOS W-PLAN MET 50x/0.75 (No Cover), with anti-fungus treatment
  • Specimen stage: Double layer rackless mechanical sliding stage, 150×139 mm, 75×33 mm X-Y movement range. Vernier scale on the two axes, accuracy: 0.1 mm.
  • Focusing: Coaxial coarse and fine focusing mechanism with limit stop to prevent the contact between objective and specimen. Adjustable tension of coarse focusing knob.
  • Condenser: Abbe N.A. 1.25, with objective-coded iris diaphragm, focusable and centerable.
  • Brightfield Illumination (Fixed Koehler type): X-LED3 with white 3.6 W LED (6,300 K) and light intensity control. Multi-plug 100-240Vac/6Vdc external power supply.
  • Fluorescence Illumination: Extra efficiency LED, with light intensity control. Peak wavelength: 465 nm, Power: 3.6W.
  • Epi Fluorescence Attachment: Slider with 3 positions (2 fluorescence, 1 brightfield), with 1 included filterset: Fluorescence B: EX 460-490, DM 505, EM 515LP: Acridine Yellow, Acridine Orange, Auramine, DiO, DTAF, FITC, GFP, YFP, etc.
  Technical Specifications:
Observation Method - Transmitted Light Brightfield Yes
  Phase contrast (Positive type) As optional
  Darkfield As optional
  Simple polarized light As optional
Observation Method - Incident Light Fluorescence Yes
Main Body Type Upright
  Construction material Aluminum die-cast
  Trasportation handle Yes
Head Type Trinocular (Siedentopf)
  Split ratio 50/50
  Inclination 30°
  360° rotating Yes
  Interpupillary distance (mm) 48-75
  Dioptric adjustement On left tube
  Fixing screw for eyepieces Yes
  Tube inner diameter (mm) 23
Eyepieces Field number (mm) 20
  Magnification 10x
  Pointer As optional
  Micrometric scale As optional
  Diameter of micrometer glass (mm) 21
  High eyepoint (for glass wearers) Yes
  Rubber cup Yes
Nosepiece Positions Quadruple
  Bi-directional Yes
  Rotation on ball bearings Yes
  Objective thread RMS
Objectives Optical system
  Anti-fungus treatment Yes
  Parfocal distance (mm) 45
  Standard magnifications 40x-400x
  Type IOS
  Objectives included OS N-PLAN 10x/0.25, W.D. 5.8 mm IOS N-PLAN 20x/0.40, W.D. 5.1 mm IOS N-PLAN 40x/0.65, W.D. 0.43 mm IOS W-PLAN MET 50x/0.75, W.D. 0.32 mm
Stage Type Double layer
  Dimensions (mm) 150x139
  Moving mechanism Rackless
  Moving range (mm) 75x33
  Material Anti-scratch painting
  Specimen holder Yes
  Slide number 1
  X-Y Vernier scale Yes
  Vernier scale accuracy (mm) 0.1
Condenser - Single Position Type Abbe
  Removable Yes
  Numerical aperture (N.A.) 1.25
  Magnification scale for simplified positioning Yes
  Diaphragms Iris
  Centrable Yes
  Focusable By rack and pinion
Focusing System Type Coaxial coarse & fine
  Coarse total travel (mm) 18
  Fine total travel (per single rotation) (mm) 0.4
  Fine graduations 100
  Fine resolution (µm) 4
  Upper stop to prevent contact Yes
  Adjustable tension Yes
Transmitted Illumination Kohler illumination Fixed
  Type X-LED
  X-LED type X-LED3
  Light source power (W) 3.6
  Brightness control Manual
  Lifetime (hours) > 65,000
  Temperature (K) 6,300
  Max. required power (W) 6
Power Supply for Transmitted Illumination Type External
  Microscope connector Jack, 2.1 mm
  Power plug type Multi-plug (EU, UK, US)
  Input voltage 100/240 Vac, 50/60 Hz
  Output voltage 6 Vdc  2.5A
Accessories Included Dust cover Yes
  Immersion oil (10ml) Yes
  Tension adjustment tool Yes
  User Manual Digital version (downloadable)
Additional Information Mirror for transmitted light (as optional). External rechargeable battery pack (as optional)
Product Weight Height (mm) 515
  Width (mm) 235
  Depth (mm) 340
Product Weight (kg) 7.5
Fluorescence Attachment Number of positions 3
  Blue filter set (included) specs Excitation: 460 - 490 nm; Dichroic: 505 nm; Emission: 515LP nm
  Filter dimensions Excitation: 18 mm diam.; Dichroic: 26.5 mm x 19 mm; Emission: 18 mm diam.
  Filter set selection Manual
Fluorescence Light Source Light source Blue LED
  Watt (W) 3.6
  LED wavelength Blue LED: 465 nm
  Lifetime (hours) > 65,000
  Brightness control Yes
The technical innovation of the iSED® fully-automated ESR analyzer consists of directly measuring the intensity of the red cell aggregation which is responsible for Erythrocyte Sedimentation Rate (ESR). Unlike traditional ESR methodologies that measure the aggregation of the red blood cells indirectly, the iSED measures it directly and expresses the values in mm/hr. Features:
  • Results in 20 Seconds

  • 100µL sample drawn directly from primary EDTA tube

  • Fully automated, walk-away operation

  • Random access

  • Positive patient identification via internal barcode reader

  • Compatible with pediatric tube

     
Technical Specifications: 
Principle of Measure: Photometrical
Results: “Printed mm/hr, Range from 1-130 mm/hr”
Sample Requirements: 500uL whole blood, collected in EDTA anti-coagulant tested 24 hours from venipuncture at room temperature or refrigerated.
Tube Requirements: 13 x 75 mm, pierceable capped tube
Quality Control: Barcoded Seditrol® QC
Barcode Reader: Internal
Printer: Internal
Interface Specifications: serial RS232 port for LIS connection
Weight: 14 kg
Dimensions (H x W x D): 36 x 27 x 34 (cm) /14.3 x 10.5 x13.4 (in)
Voltage: 100-240VAC
Frequency Range: 50-60 Hz
Power: 160W
Click Here To Download Catalogue
  • Made of high quality PP material with good transparency.
  • Applied for Gilson/Finland/Eppendorf Pipettors.
  • Carefully inspect of raw material and manufactured under strict process check, all tips are with excellent accuracy and precison.
  • Special siliconizing on the inner surface ensure no liquid adhesion and accurate sample transfer.
  • Standard tips and filter tips can be autoclaved, high temperature sterilization acceptable.
  Classification: PIPETTE Brand Name: Vchanslab,Yingmed,OEM Model Number: YM-K7028 Place of Origin: China Product name: Pipette Tips Material: Polypropylene Certificate: CE/ISO13485/FDA Color: Natural, Blue, Yellow Application: Laboratory, Teaching, Hospital
Twenty Five (25) Test Strip per Pack
  • Made of high quality PP material with good transparency.
  • Applied for Gilson/Finland/Eppendorf Pipettors.
  • Carefully inspect of raw material and manufactured under strict process check, all tips are with excellent accuracy and precison.
  • Special siliconizing on the inner surface ensure no liquid adhesion and accurate sample transfer.
  • Standard tips and filter tips can be autoclaved, high temperature sterilization acceptable.
  Classification: PIPETTE Brand Name: Vchanslab,Yingmed,OEM Model Number: YM-K7028 Place of Origin: China Product name: Pipette Tips Material: Polypropylene Certificate: CE/ISO13485/FDA Color: Natural, Blue, Yellow Application: Laboratory, Teaching, Hospital
Skyla HB1 Clinical Chemistry Analyzer utilizes precision photometric measurement technology, combined with the single-use disposable reagent discs. The reagent disc contains a set of dry assay reagents that are used in the quantitative testing of various biomarkers in the blood sample. HB1 provides clinical testing laboratories of medical facilities and clinics with an in-vitro clinical chemistry diagnostic tool that is compact, portable, and reports rapid results. Only needs 200µl of blood (whole blood, serum or plasma is accepted.) and no sample preparation is required. All steps are designed automatically from checking the validity of reagent discs and cartridges to printing the results. Over 30 test parameters are allowed with fast analysis and results in 15 minutes. Internal Quality Control (IQC) with self-calibration of optical system, chemicals stability and interference alerts functions monitor and ensure the results with high accuracy. Available Test Panels
  • Renal Function - BUN, CREA eGFR
  • Liver Function - ALB, TP, ALP, ALT, AST, TBIL, DBIL, GGT, LDH A/G#, GLOB#, IBIL
  • Lipid Metabolism - TG, TC, HDL LDL#, VLDL
  • Pancreatitis Markers - AMY, LIPA
  • Carbohydrate Metabolism and Others - GLU , CPK, UA, LAC
  • Inflammatory Markers - CRP
  • Electrolyte - Na, K, Cl, Ca, PHOS, Mg, tCO2
SPECIFICATION Principle
  • Colormetric System : LEDs 340nm~940nm wavelength
Sample & Panel
  • Test Profiles : Panels
  • Measurement Time - Panel: up to 15 tests/ 15 min
  • Sample Type & Volume : 200 μl whole blood (PCV<60%), plasma, serum 
Device
  • User Interface : 5 inch color LCD touch screen
  • Internal Memory : Store up to 50,000 analysis results
  • Printer : Built in thermal printer or external USB printer (PCL 3GUI)
  • USB Socket : USB type A (Host) for external USB Printer, USB flash drive (FAT) or external barcode scanner
  • Data transmission to PC : RS232 serial port or RJ45 (LAN)
  • Dimensions : 233 (W) X 285 (D) X 300 (H) mm
  • Weight : 5.5 kg
Operating Condition
  • Temperature / Humidity : 10 to 32˚C / 5 to 90 %
 
Click Here To Download Catalogue
WeightN/AN/AN/AN/AN/AN/A
DimensionsN/AN/AN/AN/AN/AN/A
Additional information
Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • Rating
  • Price
  • Description
Click outside to hide the comparison bar