Key Features
  • Operating temperature 0 °C to 40 °C (32 °F to 104 °F)
  • Dual state-of-the-art oxygen and carbon dioxide sensors
  • Two analogue outputs, one for each gas detected
  • Maximum power consumption less than 5 watts
  • Designed to operate safely in a vacuum for four hours
Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
SF1033560130141-12
Brands:: Analox

Description

Description

The SV-Multigas-2 is a dual oxygen (O2) and carbon dioxide (CO2) monitor designed for vehicles operating in the upper atmosphere. Housed in a robust, compact enclosure, the unit is ideal for use in airborne delivery systems, satellites and aircraft cabins. Since 2014 the SV-Multigas-2 has been successfully used in rockets travelling to outer space.

Flexibility

The SV-Multigas-2 incorporates user maintainable analogue sensors that provide a 1 to 5 V output. This modular approach to gas monitoring ensures that our customers have the flexibility to integrate the unit into their own system. It can be either installed directly in the gas path or used for general air monitoring.

 

Technical Specification

SV-Multigas-2

Reviews

There are no reviews yet.

Be the first to review “OXYGEN & CARBON DIOXIDE MONITOR”

Your email address will not be published. Required fields are marked *

Quick Comparison

OXYGEN & CARBON DIOXIDE MONITOR removeAx60+ Kiosk removeCARBON MONOXIDE MONITORING SYSTEM (AX60+ CO) removePilot-RO Water Purification System removeFull Touch Screen Water Purification System removeVENUS SOLO OEM SENSOR remove
NameOXYGEN & CARBON DIOXIDE MONITOR removeAx60+ Kiosk removeCARBON MONOXIDE MONITORING SYSTEM (AX60+ CO) removePilot-RO Water Purification System removeFull Touch Screen Water Purification System removeVENUS SOLO OEM SENSOR remove
Image
SKUSF1033560130141-12SF1033560130141-6SF1033560130141-1SF1033560130126-2SF1033560130126-4SF1033560130141-15
Rating
Price

$0.00

$0.00

$0.00

$0.00

$0.00

$0.00

Stock
Availability
Add to cart

DescriptionShipped From Abroad
Key Features
  • Operating temperature 0 °C to 40 °C (32 °F to 104 °F)
  • Dual state-of-the-art oxygen and carbon dioxide sensors
  • Two analogue outputs, one for each gas detected
  • Maximum power consumption less than 5 watts
  • Designed to operate safely in a vacuum for four hours
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad
Key Features
  • Low maintenance
  • Quick Connect System
  • Pre-wired, ready to go
  • Can support up to 4 alarm units
  • Push button for unit testing
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad

The Ax60+ CO protects users in plant rooms, parking garages and anywhere that carbon monoxide can collect. The Ax60+ CO also can be used for online cylinder filling, to protect divers from compressed air contaminated with carbon monoxide related to compressor maintenance or contamination at the compressor inlet.

The Ax60+ CO benefits from the ability to operate as a single sensor and alarm or as part of a system of up to 4 sensors. Each system can also be composed of Ax60+: O2 sensors and Ax60+ CO2 sensors so it can fulfil multiple application needs.
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad An economical choice of primary pure water for daily laboratory cleaning , with a water output of 45 - 180 liters per hour, ion retention rate >98%, organic matter retention rate >99% (when MW >200 Daltons), particle and bacteria retention rate >99%, which can meet the requirements of conventional production process water and laboratory utensil cleaning water, and can be used as the inlet water for ultrapure water systems, high-pressure steam sterilizers, environmental test chambers and other instruments.
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad The Center series uses city tap water as the water source, conveniently and quickly produces secondary RO reverse osmosis water, DI/EDI deionized water and UP ultrapure water. It adopts standard two-stage reverse osmosis system and EDI technology and modules*, and continuously produces Class II pure water with a TOC of more than 10MΩ.cm (25℃) and less than 30ppb*, and ultrapure water of 18.2MΩ.cm (25℃).There are currently four sub-product series of Center (Center-EDI) pure water and ultrapure water, and the system water output is: 45, 60, and 90 liters/hour.
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad
Key Features
  • Single gas (user defined)
  • Backward compatible with ADC’s ‘Eclipse’
  • Linearised Output
  • Continuous status signal to check device health
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Content
Description
The SV-Multigas-2 is a dual oxygen (O2) and carbon dioxide (CO2) monitor designed for vehicles operating in the upper atmosphere. Housed in a robust, compact enclosure, the unit is ideal for use in airborne delivery systems, satellites and aircraft cabins. Since 2014 the SV-Multigas-2 has been successfully used in rockets travelling to outer space. Flexibility The SV-Multigas-2 incorporates user maintainable analogue sensors that provide a 1 to 5 V output. This modular approach to gas monitoring ensures that our customers have the flexibility to integrate the unit into their own system. It can be either installed directly in the gas path or used for general air monitoring.  
Technical Specification
SV-Multigas-2
CO2 MONITOR & ALARM DESIGNED FOR KIOSKS

The Ax60+ Kiosk is a CO2 monitor and alarm specifically designed by Analox to alert personnel to a build up/leak of CO2 using a state-of-the-art infrared sensor. The alarm provides both audio and visual alerts in the case of increased levels of carbon dioxide (CO2). Up to four alarms can be added as needed and the unit does not need periodic calibration.

CO2 monitoring with the AX60+ Kiosk
The Ax60+ Kiosk is a smaller version of the popular Ax60+ carbon dioxide (CO2) monitor. It is simple to wall mount in the area where carbon dioxide (CO2) is stored or piped. The Ax60+ Kiosk sensor needs to be installed at a height of 12-18 inches (305-457mm) above the floor – this is because the carbon dioxide (CO2) that leaks from a gas cylinder is denser than ambient air and can collect at low levels. The alarm should be located above the sensor at about head height or at the entrance to the kiosk.  
Technical Specification
Sensor Unit
https://youtu.be/--wsZFTYVWs?si=nI8q1AThpkBD4yNv https://youtu.be/Bi7CmSLIIbA?si=dVXlyZaRw893no_T  
Key Features
  • Ambient CO monitoring
  • Online CO monitoring
  • Can be used with Nitrogen (N2) background gasses or, with calibration, can be used with Helium (He) background gasses
  • Has up to 3 user configurable alarms
  • Can operate as a stand alone sensor or as part of a larger system
  • Compatible with the rest of the Ax60+ range
 
Click here to download Quick Start Guide
Click here to download Manual
Click here to download Service Manual
An economical choice of primary pure water for daily laboratory cleaning , with a water output of 45 - 180 liters per hour, ion retention rate >98%, organic matter retention rate >99% (when MW >200 Daltons), particle and bacteria retention rate >99%, which can meet the requirements of conventional production process water and laboratory utensil cleaning water, and can be used as the inlet water for ultrapure water systems, high-pressure steam sterilizers, environmental test chambers and other instruments
Technical Parameters
Product Model Pilot-RO45 Pilot-RO63 Pilot-RO90 Pilot-RO120 Pilot-RO180
Pure water output* 45L/Hour 63L/Hour 90L/Hour 120L/Hour 180L/Hour
RO reverse osmosis water indicators
 Ion retention rate 98%-99% (when using new RO membrane)
 Organic matter retention rate >99%, when MW>200 Daltons
 Particle and bacteria retention >99%
 bacteria <0.01 cfu/ml (optional 0.2μm imported PES terminal filter)
 Particles (>0.2μm) <1/ml (optional (0.2μm imported PES terminal filter)
Raw water requirements Urban drinking tap water, water temperature 5-45℃, water pressure 1.0-4.0Kgf/ cm2
Size and weight Length × width × height: 640 × 540 × 1110mm; Weight: about 70Kg
Electrical requirements 220V, 50/Hz
power 120W 120W 240W 240W 240W
System Configuration Main unit (including 1 set of purification column) + 2 built-in 15L pressure water buckets + TDS/conductivity test pen + accessory bag
Performance characteristics
  • New 7.0-inch color touch screen

Animated menu, system information at a glance, and a new fingertip touch operation experience.

  • The lab optimized standard two-stage reverse osmosis system

The use of dual pumps, dual membranes and transition water tanks reduces system energy consumption, reduces wastewater and produces more stable water quality.

  • Advanced EDI technology and modules

Providing you with consistent 10MΩ.cm grade high purity water at an optimized operating cost.

  • Removable water tray

Prevent water droplets from splashing, store water in time, facilitate cleaning, and keep the system clean.

  • Built-in double water tank
Built-in 20L PE water tank and 1 20L pressure water bucket, saving more experimental space and eliminating the inconvenience of external water bucket.
Features and Advantages
  • The ultrapure water circulation system can be started and shut down freely to maintain the low bacterial contamination level of the system
  • Ultrapure water full pipeline disinfection program, can manually execute "circulation disinfection", "water inlet disinfection", "water tank filling", "manual sewage discharge", "stop disinfection"
  • Fully automatic RO membrane anti-scaling flushing (flushing interval and duration can be set) and manual forced flushing program to extend the service life of the RO membrane
  • The life of PP, KDF, AC, RO, UP, UF, TF, and UV consumables can be set, and the used time can be displayed, and automatic replacement reminders will be given when the time expires.
  • Water shortage and water full alarm, source water, RO reverse osmosis water, DI deionized water/UP ultrapure water exceeding the standard alarm
  • Compatible with two pure water storage methods: pressure water bucket and liquid level water tank, which can directly display the water storage capacity of the water tank to meet different application needs
  • System time setting (year/month/day/hour/minute), timed standby (0~60min), timed shutdown (0~24hour) functions
  • Record and check the replacement time of consumables at any time to fully grasp the equipment maintenance information
  • Complete information query and data management functions, fully control system operation status, water quality, consumables usage, timely alarm, historical alarm and other information
  • The entire pipeline adopts quick plug-in interface, and all pipes and joints are NSF certified
  • DOW RO reverse osmosis membrane ensures stable operation and high desalination rate
  • DOW's high-purity nuclear-grade resin ensures that the water produced reaches 18.2MΩ.cm and reduces TOC precipitation
  • Ultra-long life 254 & 185nm dual wavelength UV lamp, effective sterilization, reducing TOC
  • MWCO 5000D UF ultrafiltration module, effectively removes endotoxins/pyrogens
  • 0.2μm PES polyethersulfone composite membrane terminal filter to ensure pure water quality
Description
The Venus Solo OEM sensor is a self-contained unit designed for integration into other manufacturers’ equipment and provides a measurement of gas concentration according to specific user requirements. These GFC (Gas Filter Correlation) sensors generate a signal proportional to the infrared absorption of the measured gas. Providing the gas concentration lies within the designed range of the sensor, the signal is periodically compared with a reference gas. Gas concentrations are indicated through the non-linearised analogue signal output. Gas connections to and from the sensor are via suitable fittings on the gas measuring cell. The Venus Solo OEM Series sensors electrical supply is designed to accept 24V DC (3amp max). Our Venus Solo OEM sensor uses GFC (Gas Filter Correlation) technology to give highly accurate gas measurements. The Venus Solo can be integrated into your own gas analyzer or management system and offers the user a 0-2.5v analogue output.

The sensor is currently available as either: Carbon dioxide (CO2), carbon monoxide (CO), nitrous oxide (N20), methane (CH4) or nitric oxide (NO). If your application requires a different gas, just let us know and we can customise it to your needs. The Venus Solo is used in Military applications to protect submariners from carbon monoxide (CO) exposure.  

Technical Specification
Venus Solo
WeightN/AN/AN/AN/AN/AN/A
DimensionsN/AN/AN/AN/AN/AN/A
Additional information
Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • Rating
  • Price
  • Description
Click outside to hide the comparison bar
Compare