Spin Tissue Processor STP 120

$6,050.00

Shipped From Abroad

Myr Spin Tissue Processor STP 120 has been developed to meet the requirements of every single laboratory. The technology and the unique processing method of the STP 120 qualifies it as the most successful Spin Tissue Processors ever. With more than 3.500 units installed around the world confirms its leading position.

Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
SF1033560130128-3
Brands:: Myr

Description

Features
  • A worldwide unique technique

Tissue processing is a technique than uses alcohols to remove water from tissues and replace it with a medium that allows sectioning of tissue. Several methods are used to achieve this. Myr Spin Tissue Processor STP 120 fulfills it in a patented and unique technique that combines several movements for the tissue to achieve perfect infiltration results. This is possible thanks to the world’s best spin processing method.

  • ROTATIONAL AGITATION

The basket with the cassettes is immersed into the reagent vessel. In this position, the basket turns at 60 rpm and changes the rotational direction every 60 seconds. The rotational agitation achieves a perfect infiltration of tissue, a homogeneous mixture of the reagents and a reduction of processing time. To get better results, the user can start optionally a shaking process.

  • SHAKING

This movement can be optionally activated on the control panel and allows the basket to perform an up-down movement inside the vessel that combined with the rotational agitation fulfills a helicoidal movement that increases infiltration quality at a high degree of precision. At the end of this process, baskets start centrifuging.

  • CENTRIFUGING

This function is activated as soon as the infiltration time comes to an end. The basket rises above the reagent’s level but rests inside the vessel. For a period of 60 seconds, it starts whirling at 210 rpm and changes the rotational direction every 15 seconds. This process allows the tissue to be optimally drained and avoids carry-over of reagents from one vessel to another.

Tissue processing achieves by this method almost similar results to those obtained with vacuum systems!

  • Ergonomic control panel

The buttons of the control panel are arranged ergonomically for easy handling. The LCD display shows all the parameters throughout the process, such as program number, vessel, remaining time, start delay, total duration of the program, rotational agitation and shaking, basket’s centrifuging, temperature of paraffin baths, date and time.

  • Easy handling

The instrument has the capacity to store up to 10 different programs that can be freely set up by the user. Each one of the programs can be started in immediate or delayed mode, without a time limit. The instrument can easily be rotated via the four rollers mounted on the base. This allows the user to have fast and safe access to each one of the vessels.

  • Maximum safety standards for the user and the specimen

The individual cover for each one of the vessels reduces the emission of vapors to a minimum. The STP 120-2 and STP 120-3 versions incorporate a fume extraction system that – through a fan and an active charcoal filter – cleanse the vapors before being discharged into the air. Optional adaptor for the laboratory general extraction system.

In case of a power shutdown, the specimens are automatically lowered inside the vessel by means of a battery to protect them against desiccation and solid paraffins. Once power is restored, the instrument resumes the program at the same point in which it was interrupted. lf it is a long power failure and the paraffin baths become solidified, the safety program will be activated. The instrument will then wait for the baths to be fully liquified before going ahead with the change to the paraffin baths.

Emergency motions can be implemented through the battery, such as moving the basket up and down or station change (as long as the basket is not inside a solidified paraffin bath). The instrument is also equipped with an emergency stop button. It is possible to interrupt a program for reloading or advanced unloading of samples.

  • Alarms during the process

If the specimens remain inside a station for a longer time than the programmed time, e.g. due to a power failure, the display will show a message indicating the station number and the overtime spent in that station compared with the initially programmed time. The acoustic and visual alarms can easily be identified by the user. The keyboard can be locked by the user to avoid an inadvertent change of the process parameters during operation.

Technical Data Spin Tissue Processor STP 120
Power requirements
Nominal voltage 100 – 120 V 220-240 V AC (±10%)
Network’s frequency 50/60 Hz
Consumption 400 VA
Fuses 115 V (2xT4A) 230 V (2xT2A)
Accumulator Nickel-Cadmium 12 V 600 mA
Capacity
Reagent stations
Number of vessels 10 (9 if 3 paraffin baths are used)
Volume per vessel 1,8 l
Paraffin stations
Number 2 (optionally 3)
Volume 1,8 l
Nominal voltage 24 V AC
Nominal power per station 100 VA
Temperature setting range (temperature increase by 1 degree celsius) 45 – 70 °C
Overtemperature release 75 °C (± 4 °C)
Cassette baskets
Number of baskets 1 (optionally 2)
Basket capacity 120 cassettes (optionally 240)
Programming
Number of programs 10 (selectable)
Infiltration time per station from 1 m to 99 h 59 m
Rotational agitation selectable
Shaking selectable
Centrifuging time selectable
Program start delay selectable without time limit
Dimensions
Diameter 850 mm
Height 500 – 700 mm
Diameter of the roller’s circle 670 mm
Weight
Including packaging 130 kg
Net (fully equipped) 70 kg

Optional accessories

Spiral support for a second cassette basket (double processing capacity)
Additional basket
Additional paraffin bath (necessary when operating the processor with two baskets)
Fume extraction system with active charcoal filter

 

Click here to download Catalogue

Reviews

There are no reviews yet.

Be the first to review “Spin Tissue Processor STP 120”

Your email address will not be published. Required fields are marked *

Quick Comparison

SettingsSpin Tissue Processor STP 120 removeSyringe Needle Destroyer removeOptika B-510ASB Trinocular Phase Contrast Microscope removeOPTIKA B-510-5 Trinocular Discussion Microscope removeHawksley 1400 Haematocrit Centrifuge removeOptika B-382PH-ALC Binocular Phase Contrast Microscope remove
NameSpin Tissue Processor STP 120 removeSyringe Needle Destroyer removeOptika B-510ASB Trinocular Phase Contrast Microscope removeOPTIKA B-510-5 Trinocular Discussion Microscope removeHawksley 1400 Haematocrit Centrifuge removeOptika B-382PH-ALC Binocular Phase Contrast Microscope remove
ImageOptika B-510ASB Trinocular Phase Contrast MicroscopeOPTIKA B-510-5 Trinocular Discussion MicroscopeOptika B-382PH-ALC Binocular Phase Contrast Microscope
SKUSF1033560130128-3SF1033560084-206SF1033560098-9SF1033560098-17SF1033560084-118SF1033560098-8
Rating
Price

$6,050.00

$157.00

$0.00

$0.00

$690.00

$0.00

Stock
Availability
Add to cart

DescriptionShipped From Abroad Myr Spin Tissue Processor STP 120 has been developed to meet the requirements of every single laboratory. The technology and the unique processing method of the STP 120 qualifies it as the most successful Spin Tissue Processors ever. With more than 3.500 units installed around the world confirms its leading position.
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock Needle destruction destroy the needle immediately following its use. Needle destruction are an absolute necessity in developing parts of the world to prevent the reuse of needles and the spread of bloodborne pathogens. They are NOT a good alternative, however, for hospital use in the developed parts of the world. Needle destruction are products that bend, cut, or destroy the needle. This are distinctly different from needle destroyer that send an arc of electricity to vaporize and melt the needle.
Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped from Abroad Advanced routine laboratory microscope for brightfield and phase contrast observations with IOS W-PLAN objectives and rackless stage. Ideal for Asbestos analysis in accordance to international rules with 12.5x eyepieces and Walton & Becket graticule to perform perfect asbestos fibers analysis at a glance. The high-efficiency X-LED3 makes it reliable for all transmitted light observations.
Delivery & Availability: Typically 21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped from Abroad OPTIKA B-510 Series represents the ideal, ultra-modern, advanced routine microscope for efficient analysis in transmitted light applications, carefully engineered considering all the relevant aspects for users.
Delivery & Availability: Typically 21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock
The Hawksley Haematospin 1400 Centrifuges are built in the UK and are made from durable and high-quality components. These centrifuges are ideal for veterinary laboratories and practices specifically designed to produce reliable and accurate results on blood and urine. One of the main features of this centrifuge is that it takes both 2ml microtubes and 75mm microhaematocrits. The classic design of these centrifuges is used worldwide with guaranteed support for all servicing and parts. Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped from Abroad Phase contrast, darkfield and brightfield binocular microscope with W-PLAN objectives, rackless stage and combining the exclusive X-LED3  with ALC (Automatic Light Control) for great-looking, rich and highquality view.
Delivery & Availability: Typically 21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Content
Features
  • A worldwide unique technique
Tissue processing is a technique than uses alcohols to remove water from tissues and replace it with a medium that allows sectioning of tissue. Several methods are used to achieve this. Myr Spin Tissue Processor STP 120 fulfills it in a patented and unique technique that combines several movements for the tissue to achieve perfect infiltration results. This is possible thanks to the world’s best spin processing method.
  • ROTATIONAL AGITATION
The basket with the cassettes is immersed into the reagent vessel. In this position, the basket turns at 60 rpm and changes the rotational direction every 60 seconds. The rotational agitation achieves a perfect infiltration of tissue, a homogeneous mixture of the reagents and a reduction of processing time. To get better results, the user can start optionally a shaking process.
  • SHAKING
This movement can be optionally activated on the control panel and allows the basket to perform an up-down movement inside the vessel that combined with the rotational agitation fulfills a helicoidal movement that increases infiltration quality at a high degree of precision. At the end of this process, baskets start centrifuging.
  • CENTRIFUGING
This function is activated as soon as the infiltration time comes to an end. The basket rises above the reagent’s level but rests inside the vessel. For a period of 60 seconds, it starts whirling at 210 rpm and changes the rotational direction every 15 seconds. This process allows the tissue to be optimally drained and avoids carry-over of reagents from one vessel to another.

Tissue processing achieves by this method almost similar results to those obtained with vacuum systems!

  • Ergonomic control panel
The buttons of the control panel are arranged ergonomically for easy handling. The LCD display shows all the parameters throughout the process, such as program number, vessel, remaining time, start delay, total duration of the program, rotational agitation and shaking, basket’s centrifuging, temperature of paraffin baths, date and time.
  • Easy handling
The instrument has the capacity to store up to 10 different programs that can be freely set up by the user. Each one of the programs can be started in immediate or delayed mode, without a time limit. The instrument can easily be rotated via the four rollers mounted on the base. This allows the user to have fast and safe access to each one of the vessels.
  • Maximum safety standards for the user and the specimen
The individual cover for each one of the vessels reduces the emission of vapors to a minimum. The STP 120-2 and STP 120-3 versions incorporate a fume extraction system that – through a fan and an active charcoal filter – cleanse the vapors before being discharged into the air. Optional adaptor for the laboratory general extraction system. In case of a power shutdown, the specimens are automatically lowered inside the vessel by means of a battery to protect them against desiccation and solid paraffins. Once power is restored, the instrument resumes the program at the same point in which it was interrupted. lf it is a long power failure and the paraffin baths become solidified, the safety program will be activated. The instrument will then wait for the baths to be fully liquified before going ahead with the change to the paraffin baths.

Emergency motions can be implemented through the battery, such as moving the basket up and down or station change (as long as the basket is not inside a solidified paraffin bath). The instrument is also equipped with an emergency stop button. It is possible to interrupt a program for reloading or advanced unloading of samples.

  • Alarms during the process
If the specimens remain inside a station for a longer time than the programmed time, e.g. due to a power failure, the display will show a message indicating the station number and the overtime spent in that station compared with the initially programmed time. The acoustic and visual alarms can easily be identified by the user. The keyboard can be locked by the user to avoid an inadvertent change of the process parameters during operation.
Technical Data Spin Tissue Processor STP 120
Power requirements
Nominal voltage 100 – 120 V 220-240 V AC (±10%)
Network’s frequency 50/60 Hz
Consumption 400 VA
Fuses 115 V (2xT4A) 230 V (2xT2A)
Accumulator Nickel-Cadmium 12 V 600 mA
Capacity
Reagent stations
Number of vessels 10 (9 if 3 paraffin baths are used)
Volume per vessel 1,8 l
Paraffin stations
Number 2 (optionally 3)
Volume 1,8 l
Nominal voltage 24 V AC
Nominal power per station 100 VA
Temperature setting range (temperature increase by 1 degree celsius) 45 – 70 °C
Overtemperature release 75 °C (± 4 °C)
Cassette baskets
Number of baskets 1 (optionally 2)
Basket capacity 120 cassettes (optionally 240)
Programming
Number of programs 10 (selectable)
Infiltration time per station from 1 m to 99 h 59 m
Rotational agitation selectable
Shaking selectable
Centrifuging time selectable
Program start delay selectable without time limit
Dimensions
Diameter 850 mm
Height 500 – 700 mm
Diameter of the roller’s circle 670 mm
Weight
Including packaging 130 kg
Net (fully equipped) 70 kg
Optional accessories
Spiral support for a second cassette basket (double processing capacity)
Additional basket
Additional paraffin bath (necessary when operating the processor with two baskets)
Fume extraction system with active charcoal filter
 
Click here to download Catalogue
Needle destruction destroys the needle immediately following its use. Needle destruction are an absolute necessity in developing parts of the world to prevent the reuse of needles and the spread of bloodborne pathogens. They are NOT a good alternative, however, for hospital use in the developed parts of the world. Needle destruction are products that bend, cut, or destroy the needle. This are distinctly different from needle destroyer that send an arc of electricity to vaporize and melt the needle. Features:
  • Well built
  • Easy to maintain
  • Having a rubbish drawer with alarm function, this is our most popular model of Syringe Destroyer for use in labs, pharma, universities and doctors clinics
  • With its low factory-direct price and excellent quality, its a great addition to add to any medical industry or university office that wants to ensure the safety and legal compliance of its operations
Specifications:
  • Short Name: Needle destruction / Needle Destroyer
  • Working Noise: ≤50 decibel
  • Superheating Sanitization Temperature: 95 deg C
  • Working Time: Can completely melt and destroy needle and neck of syringe in 5 seconds
  • Working Noise: ≤50 decibel
  • Dimensions: Approx. 38cm x 29cm x 28cm
  • Power: AC 110V or 220V
Advanced routine laboratory microscope for brightfield and phase contrast observations with IOS W-PLAN objectives and rackless stage. Ideal for Asbestos analysis in accordance to international rules with 12.5x eyepieces and Walton & Becket graticule to perform perfect asbestos fibers analysis at a glance. The high-efficiency X-LED3 makes it reliable for all transmitted light observations. Features:
  • Observation mode: Brightfield, phase contrast.
  • Head: Trinocular (fixed 50/50), 30° inclined, 360° rotating.
  • Interpupillary distance: Adjustable between 50 and 75 mm.
  • Dioptric adjustment: On the left eyepiece tube.
  • Eyepieces: WF10x/22 mm, high eye-point and WF12.5x/18 mm with dioptric adjustment, one with Walton & Beckett graticule.
  • Nosepiece: Quintuple revolving nosepiece, rotation on ball bearings.
  • Objectives: – IOS W-PLAN 4x/0.10 – IOS W-PLAN 10x/0.25 – IOS W-PLAN PH 40x/0.65 – IOS W-PLAN 100x/1.25 (Oil) All with anti-fungus treatment.
  • Specimen stage: Double layer rackless mechanical stage, 233×147 mm, 78×54 mm X-Y range.
  • Focusing: Coaxial coarse (adjustable tension) and fine focusing mechanism with limit stop to prevent the contact between objective and specimen.
  • Condenser: Abbe N.A. 1.25, with objective-coded iris diaphragm, focusable and centerable. With 40x phase contrast slider.
  • Transmitted illumination (Full Koehler type):  X-LED³ with white 3.6 W LED (6,300K) with brightness control. Multi-plug 100-240Vac/6Vdc external power supply.
  Technical Specifications:
Observation Method - Transmitted Light Brightfield Yes
  Phase contrast (Positive type) Yes
  Darkfield As optional
  Simple polarized light As optional
Main Body Type Upright
  Construction material Aluminum die-cast
  Trasportation handle Yes
Head Type Trinocular (Siedentopf)
  Split ratio 50/50
  Inclination 30°
  360° rotating Yes
  Interpupillary distance (mm) 50-75
  Tube inner diameter (mm) 30
Eyepieces Field number (mm) 22
  Magnification 10x
  Planar type Yes
  Micrometric scale As optional
  Diameter of micrometer glass (mm) 26
  High eyepoint (for glass wearers) Yes
  Rubber cup Yes
  Retractable protections Yes
Nosepiece Positions Quintuple
  Reversed Yes
  Bi-directional Yes
  Rotation on ball bearings Yes
  Objective thread RMS
Objectives Optical system
  Anti-fungus treatment Yes
  Parfocal distance (mm) 45
  Standard magnifications 40x-1000x
  Type IOS W-PLAN
  Objectives included 4x/0.10, W.D. 17.3 mm 10x/0.25, W.D. 10 mm PH 40x/0.65, W.D. 0.54 mm 100x/1.25 (Oil), W.D. 0.13 mm
Stage Type Double layer
  Dimensions (mm) 233x147
  Moving mechanism Rackless
  Moving range (mm) 78x54
  Material Anti-scratch painting
  Specimen holder Yes
  Slide number 2
  X-Y Vernier scale Yes
  Vernier scale accuracy (mm) 0.1
Condenser - Multiple Position Type Abbe. Brightfield - Phase contrast
  Number of positions 2 (BF, 40x)
  Numerical aperture (N.A.) 1.25
  Magnification scale for simplified positioning Yes
  Removable Yes
  Diaphragms Iris
  Centrable Yes
  Focusable By rack and pinion
Focusing System Type Coaxial coarse & fine
  Coarse total travel (mm) 25
  Fine total travel (per single rotation) (mm) 0.2
  Fine graduations 100
  Fine resolution (µm) 2
  Upper stop to prevent contact Yes
  Adjustable tension Yes
  Flat knob for ergonomy Yes
Transmitted Illumination Kohler illumination Full
  Type X-LED
  X-LED type X-LED3
  Light source power (W) 3.6
  Brightness control Manual  
  Lifetime (hours) > 65,000
  Temperature (K) 6,300
  Max. required power (W) 6
Power Supply for Transmitted Illumination Type External
  Microscope connector Jack, 2.1 mm
  Power plug type Multi-plug (EU, UK, US)
  Input voltage 100/240 Vac, 50/60 Hz
  Output voltage 6 Vdc  2.5A
Accessories Included Dust cover Yes
  Immersion oil (10ml) Yes
  Tension adjustment tool Yes
  Allen wrench Yes
  Centering telescope Yes
  Green filter Yes
  User Manual Digital version (downloadable)
Additional Information Heating stage (as optional). External rechargeable battery pack (as optional).
Product Weight Height (mm) 405
  Width (mm) 235
  Depth (mm) 370
Product Weight (kg) 9
Observation mode: Brightfield. Head: Trinocular (fixed photo port 50/50), 30° inclined, 360° rotating. Interpupillary distance: Adjustable between 50 and 75 mm. Dioptric adjustment: On the left eyepiece tube. Eyepieces: Main head: WF10x/22 mm, high eye-point and with rubber cups. Additional head(s): WF10x/20 mm, high eye-point. Nosepiece: Quintuple revolving nosepiece, rotation on ball bearings. Objectives (strain-free): – IOS W-PLAN 4x/0.10 – IOS W-PLAN 10x/0.25 – IOS W-PLAN 40x/0.65 – IOS W-PLAN 100x/1.25 (Oil) All with anti-fungus treatment. Specimen stage: Double layer rackless mechanical stage, 233×147 mm, 78×54 mm X-Y range. Focusing: Coaxial coarse (adjustable tension) and fine focusing mechanism with limit stop to prevent the contact between objective and specimen. Condenser: Swing-out N.A. 0.2/0.9, with iris diaphragm, focusable and centerable. Transmitted illumination (Full Koehler type): X-LED3 with white 3.6 W LED (6,300K) with brightness control. Multi-plug 100-240Vac/6Vdc external power supply.
Specifications:
Optics
Image scale 4-100
Number of objectives 4
Lighting Transmitted light
Field curvature Plan
Colour correction achromatic
Suspension yes
Immersion lens yes
Condensor Abbe N.A.1.25
Lamp type LED (X-LED3, 3.6 W, comparable to a 50 W halogen bulb)
Objective 1 IOS W-PLAN 4x/0.10, W.D. 17.3 mm
Objective 2 IOS W-PLAN 10x/0.25, W.D. 10 mm
Objective 3 IOS W-PLAN 40x/0.65, W.D. 0.54 mm
Objective 4 IOS W-PLAN 100x/1.25, W.D. 0.13 mm, oil
Eyepiece WF 10x / 22 mm (Ø 30mm)
infinity corrected yes
Magnification 40-1000
Optical system infinity
Capacity
Brightness control yes
Fluorescence yes
brightfield yes
Mechanics
Type of build Trinocular
Viewing posture (°) 30° angled eyepiece
Specimen stage Cross table
Revolver 5
Focusing Coarse and fine movement
General
Weight (g) 9100
Height (mm) 420
Width (mm) 270
Length (mm) 390
Series B-510
Field of application
Biology and Medicine yes
 
Click Here To Download Catalogue
The Hawksley Haematospin 1400 Centrifuges are built in the UK and are made from durable and high-quality components. These centrifuges are ideal for veterinary laboratories and practices specifically designed to produce reliable and accurate results on blood and urine. One of the main features of this centrifuge is that it takes both 2ml microtubes and 75mm microhaematocrits. The classic design of these centrifuges is used worldwide with guaranteed support for all servicing and parts. Technical specifications:
  • Speed: 11,800rpm with 24- place rotor
  • RCF: 14,000g with 24-place rotor
  • Acceleration: 0-11,800rpm in 60 seconds, with 24-place rotor
  • Brake: Automatic
  • Noise: 62dB running with 24-place rotor
  • Motor: High precision AC/DC series wound motor, brush gear, computer wound coil winding, balance armature and high speed bearings.
  • Timer: 0-15 minute timer, graduated in 1 minute increments. Automatic switch at zero
  • Weight: 5.1Kg net (without rotor)
  • Dimensions: 23.5cm height x 27cm diameter, footprint 16cm diameter
  • Construction: Aluminium casing with a steel lid
  • Finish: Body cream white baked enamel, with matt black baked enamel lid
 
Click Here To Download Catalogue
Phase contrast, darkfield and brightfield binocular microscope with W-PLAN objectives, rackless stage and combining the exclusive X-LED3  with ALC (Automatic Light Control) for great-looking, rich and highquality view. Features:
  • Observation mode: Brightfield, phase contrast and darkfield (dry).
  • Head: Binocular, 30° inclined, 360° rotating (when ALC cable is unplugged).
  • Interpupillary distance: Adjustable between 48 and 75 mm.
  • Dioptric adjustment: On the left eyepiece tube.
  • Eyepieces: WF10x/20 mm, high eye-point and secured by screw.
  • Nosepiece: Quintuple revolving nosepiece, rotation on ball bearings.
  • Objectives: W-PLAN 4x/0.10 W-PLAN PH 10x/0.25 W-PLAN PH 40x/0.65 W-PLAN PH 100x/1.25 (Oil/Water) All with anti-fungus treatment.
  • Specimen stage: Double layer rackless mechanical stage, 150×139 mm, 75×33 mm X-Y range.
  • Focusing: Coaxial coarse (adjustable tension) and fine focusing mechanism with limit stop to prevent the contact between objective and specimen.
  • Condenser: Phase condenser (10x/20x, 40x, 100x) with darkfield (dry) and brightfield.
  • Illumination (Fixed Koehler type): X-LED3 with white 3.6 W LED (6,300K) and brightness control. ALC system. Multi-plug 100-240Vac/6Vdc external power supply
Technical Specifications:
Observation Method - Transmitted Light Brightfield Yes
  Phase contrast (Positive type) Yes
  Darkfield Yes
  Simple polarized light As optional
Main Body Type Upright
  Construction material Aluminum die-cast
  Trasportation handle Yes
Head Type Binocular (Siedentopf)
  Inclination 30°
  360° rotating Yes
  Interpupillary distance (mm) 48-75
  Dioptric adjustement On left tube
  Fixing screw for eyepieces Yes
  Tube inner diameter (mm) 23
Eyepieces Field number (mm) 20
  Magnification 10x
  Pointer As optional
  Micrometric scale As optional
  Diameter of micrometer glass (mm) 21
  High eyepoint (for glass wearers) Yes
  Rubber cup Yes
Nosepiece Positions Quintuple
  Reversed Yes
  Bi-directional Yes
  Rotation on ball bearings Yes
  Objective thread RMS
Objectives Optical system 160
  Anti-fungus treatment Yes
  Parfocal distance (mm) 45
  Standard magnifications 40x-1000x
  Type IOS
  W-PLAN 4x/0.10, W.D. 15.8 mm W-PLAN PH 10x/0.25, W.D. 12.2 mm W-PLAN PH 40x/0.65, W.D. 0.37 mm W-PLAN PH 100x/1.25 (Oil), W.D. 0.13 mm
Stage Type Double layer
  Dimensions (mm) 150x139
  Moving mechanism Rackless
  Moving range (mm) 75x33
  Material Anti-scratch painting
  Specimen holder Yes
  Slide number 1
  X-Y Vernier scale Yes
  Vernier scale accuracy (mm) 0.1
Condenser - Multiple Position Type Abbe. Brightfield - Phase contrast - Darkfield (dry)
  Number of positions 5 (BF, 10x/20x, 40x, 100x, DF)
  Numerical aperture (N.A.) 1.25
  Removable Yes
  Diaphragms Iris
  Centrable Yes
  Focusable By rack and pinion
Focusing System Type Coaxial coarse & fine
  Coarse total travel (mm) 25
  Fine total travel (per single rotation) (mm) 0.2
  Fine graduations 100
  Fine resolution (µm) 2
  Upper stop to prevent contact Yes
  Adjustable tension Yes
  Flat knob for ergonomy Yes
Transmitted Illumination Kohler illumination Fixed (full as optional)
  Type X-LED
  X-LED type X-LED3
  Light source power (W) 3.6
  Brightness control Manual & Automatic (ALC)
  Lifetime (hours) > 65,000
  Temperature (K) 6,300
  Max. required power (W) 6
Power Supply for Transmitted Illumination Type External
  Microscope connector Jack, 2.1 mm
  Power plug type Multi-plug (EU, UK, US)
  Input voltage 100/240 Vac, 50/60 Hz
  Output voltage 6 Vdc  2.5A
Accessories Included Dust cover Yes
  Immersion oil (10ml) Yes
  Tension adjustment tool Yes
  Allen wrench Yes
  Centering telescope Yes
  Green filter Yes
  User Manual Digital version (downloadable)
Additional Information External rechargeable battery pack (as optional)
Product Weight Height (mm) 405
  Width (mm) 235
  Depth (mm) 370
Product Weight (kg) 8
WeightN/AN/AN/AN/AN/AN/A
DimensionsN/AN/AN/AN/AN/AN/A
Additional information
Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • Rating
  • Price
  • Description
Click outside to hide the comparison bar
Compare