Skyla HB1 POC Clinical Chemistry Auto Analyzer
$0.00
Shipped from Abroad
The skyla HB1 Clinical Chemistry Analyzer provides clinical testing laboratories of medical facilities and clinics with an in-vitro clinical chemistry diagnostic tool that is compact, portable, and reports rapid results. The portable design of the clinical chemistry analyzer utilizes precision photometric measurement technology, combined with the single-use disposable reagent discs. The reagent disc contains a set of dry assay reagents that are used in the quantitative testing of various biomarkers in the blood sample.
Delivery & Availability:
Typically 14 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Description
Skyla HB1 Clinical Chemistry Analyzer utilizes precision photometric measurement technology, combined with the single-use disposable reagent discs. The reagent disc contains a set of dry assay reagents that are used in the quantitative testing of various biomarkers in the blood sample. HB1 provides clinical testing laboratories of medical facilities and clinics with an in-vitro clinical chemistry diagnostic tool that is compact, portable, and reports rapid results. Only needs 200µl of blood (whole blood, serum or plasma is accepted.) and no sample preparation is required. All steps are designed automatically from checking the validity of reagent discs and cartridges to printing the results. Over 30 test parameters are allowed with fast analysis and results in 15 minutes. Internal Quality Control (IQC) with self-calibration of optical system, chemicals stability and interference alerts functions monitor and ensure the results with high accuracy.
Available Test Panels
- Renal Function – BUN, CREA eGFR
- Liver Function – ALB, TP, ALP, ALT, AST, TBIL, DBIL, GGT, LDH A/G#, GLOB#, IBIL
- Lipid Metabolism – TG, TC, HDL LDL#, VLDL
- Pancreatitis Markers – AMY, LIPA
- Carbohydrate Metabolism and Others – GLU , CPK, UA, LAC
- Inflammatory Markers – CRP
- Electrolyte – Na, K, Cl, Ca, PHOS, Mg, tCO2
SPECIFICATION
Principle
- Colormetric System : LEDs 340nm~940nm wavelength
Sample & Panel
- Test Profiles : Panels
- Measurement Time – Panel: up to 15 tests/ 15 min
- Sample Type & Volume : 200 μl whole blood (PCV<60%), plasma, serum
Device
- User Interface : 5 inch color LCD touch screen
- Internal Memory : Store up to 50,000 analysis results
- Printer : Built in thermal printer or external USB printer
(PCL 3GUI) - USB Socket : USB type A (Host) for external USB Printer, USB
flash drive (FAT) or external barcode scanner - Data transmission to PC : RS232 serial port or RJ45 (LAN)
- Dimensions : 233 (W) X 285 (D) X 300 (H) mm
- Weight : 5.5 kg
Operating Condition
- Temperature / Humidity : 10 to 32˚C / 5 to 90 %
Click Here To Download Catalogue
Reviews(6)
Quick Comparison
Settings | Skyla HB1 POC Clinical Chemistry Auto Analyzer remove | Eppendorf Pipette Tip 200ul Per Pack remove | iSED Fully Automated ESR Analyzer remove | Hawksley 1400 Haematocrit Centrifuge remove | AGD Erma EL-120 ELectrolyte Analyzer remove | Avalun LabPad Device remove | ||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Name | Skyla HB1 POC Clinical Chemistry Auto Analyzer remove | Eppendorf Pipette Tip 200ul Per Pack remove | iSED Fully Automated ESR Analyzer remove | Hawksley 1400 Haematocrit Centrifuge remove | AGD Erma EL-120 ELectrolyte Analyzer remove | Avalun LabPad Device remove | ||||||||||||||||||||||||||||||||||||||||||||||||||||||
Image | ![]() | ![]() | ![]() | ![]() | ![]() | ![]() | ||||||||||||||||||||||||||||||||||||||||||||||||||||||
SKU | SF1033560060-1 | SF1033560084-137 | SF1033560084-129 | SF1033560084-118 | SF1033560084-125 | SF1033560084-65 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||
Rating | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Price |
|
|
| $690.00 | $1,320.00 |
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||
Stock | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Availability | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Add to cart | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Description | Shipped from Abroad The skyla HB1 Clinical Chemistry Analyzer provides clinical testing laboratories of medical facilities and clinics with an in-vitro clinical chemistry diagnostic tool that is compact, portable, and reports rapid results. The portable design of the clinical chemistry analyzer utilizes precision photometric measurement technology, combined with the single-use disposable reagent discs. The reagent disc contains a set of dry assay reagents that are used in the quantitative testing of various biomarkers in the blood sample. Delivery & Availability: Typically 14 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | In stock
| In stock
| In stock
| Shipped From Abroad
| In stock The coagulometer, LabPad® INR, measures blood coagulation time thanks to a patented optical technology. This portable In-Vitro Diagnostics (IVD) device works with the Tsmart® INR single-use microcuvettes. Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | ||||||||||||||||||||||||||||||||||||||||||||||||||||||
Content | Skyla HB1 Clinical Chemistry Analyzer utilizes precision photometric measurement technology, combined with the single-use disposable reagent discs. The reagent disc contains a set of dry assay reagents that are used in the quantitative testing of various biomarkers in the blood sample. HB1 provides clinical testing laboratories of medical facilities and clinics with an in-vitro clinical chemistry diagnostic tool that is compact, portable, and reports rapid results. Only needs 200µl of blood (whole blood, serum or plasma is accepted.) and no sample preparation is required. All steps are designed automatically from checking the validity of reagent discs and cartridges to printing the results. Over 30 test parameters are allowed with fast analysis and results in 15 minutes. Internal Quality Control (IQC) with self-calibration of optical system, chemicals stability and interference alerts functions monitor and ensure the results with high accuracy.
Available Test Panels
Click Here To Download Catalogue |
| The technical innovation of the iSED® fully-automated ESR analyzer consists of directly measuring the intensity of the red cell aggregation which is responsible for Erythrocyte Sedimentation Rate (ESR). Unlike traditional ESR methodologies that measure the aggregation of the red blood cells indirectly, the iSED measures it directly and expresses the values in mm/hr.
Features:
| The Hawksley Haematospin 1400 Centrifuges are built in the UK and are made from durable and high-quality components. These centrifuges are ideal for veterinary laboratories and practices specifically designed to produce reliable and accurate results on blood and urine. One of the main features of this centrifuge is that it takes both 2ml microtubes and 75mm microhaematocrits. The classic design of these centrifuges is used worldwide with guaranteed support for all servicing and parts.
Technical specifications:
Click Here To Download Catalogue | Electrolyte Analyzer ERMA EL-120 is ideal for medium to high volume Laboratories and Hospitals . It offers reliable, automated samples handling and work flow offences . It also allows measurement of specific ions, accurately and precisely . This supports fast diagnosis of critically ill patients and reduces the risks of patient discomfort associated with repeated sampling Precise & Accurate Results Economical to use Large Touchscreen Display with Graphical User Interface.
Features:
Click Here To Download Catalogue | The coagulometer, LabPad® INR, measures blood coagulation time thanks to a patented optical technology. This portable In-Vitro Diagnostics (IVD) device works with the Tsmart® INR single-use microcuvettes.
Click Here To Download Catalogue | ||||||||||||||||||||||||||||||||||||||||||||||||||||||
Weight | N/A | N/A | N/A | N/A | N/A | N/A | ||||||||||||||||||||||||||||||||||||||||||||||||||||||
Dimensions | N/A | N/A | N/A | N/A | N/A | N/A | ||||||||||||||||||||||||||||||||||||||||||||||||||||||
Additional information |
Enrique Chargois
Terrific article
Beau Szynkowicz
world is changing
renault clio key replacement
Some really great info, Gladiola I detected this. I’m not spaming. I’m just saying your website is AWSOME! Thank you so much! Please vist also my website. https://local-auto-locksmith.co.uk/renault/
Aurora
Greetings from Idaho! I’m bored at work so I decided to check out your blog on my iphone during lunch break.
I really like the info you present here and can’t wait to take a look when I get home.
I’m surprised at how fast your blog loaded on my phone ..
I’m not even using WIFI, just 3G .. Anyhow, good site!
Antonia
This is my first time pay a quick visit at here and i am in fact impressed to read everthing at
single place.
Affiliate Marketing
Wow, fantastic weblog layout! How long have you ever been running a blog for? you make blogging glance easy. The whole glance of your web site is magnificent, as neatly as the content!