Smart-RO Water Purification System

$0.00

Shipped From Abroad

An economical choice of primary pure water for daily laboratory cleaning, with an hourly water output of 15-30 liters, ion retention rate >97%, organic matter retention rate >99% (when MW >200 Daltons), particle and bacteria retention rate >99%, which can meet the water requirements for routine laboratory ware cleaning and can be used as the inlet water for ultrapure water systems, high-pressure steam sterilizers, environmental test chambers and other instruments.

Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
SF1033560130126-1
Brands:: Hi-Tech

Description

Technical Parameters
Product Model Smart-RO15 Smart-RO30
Pure water output* 15L/Hour 30L/Hour
Instantaneous water output** Up to 2.0L/Min (when there is water in the water tank)
RO reverse osmosis water indicators
 Ion retention rate 97%-99% (when using new RO membrane)
 Organic matter retention rate >99%, when MW>200 Daltons
 Particle and bacteria retention >99%
 bacteria <0.01 cfu/ml (optional (0.45+0.1)μm imported PES terminal filter)
 Particles (>0.2μm) <1/ml (optional (0.45+0.1)μm imported PES terminal filter)
Raw water requirements Urban drinking tap water, water temperature 5-45℃, water pressure 1.0-4.0Kgf/ cm2
Instantaneous water output 2.0L/min (pressure water bucket required)
Water outlet 1: RO reverse osmosis water
Dimensions/weight Length × width × height: 41 × 22 × 42 cm / about 20 kg
Electrical requirements 100-240V, 50/60Hz
power 48W 72W
System Configuration Main unit (including 1 set of purification column) + 15L pressure water bucket + TDS/conductivity test pen + accessory bag
Consumables Information
Part Number/Model Product Name Service life/root (estimated)
PC-M-PP 5μmPP depth filter element About 2-6 months
PC-PP-ZK Zikang PP filter element About 2-6 months*
PC-AC-B-ZK Zikang activated carbon filter About 4-6 months*
PTC-AC-HZS1 Organic matter purification column About 6800 liters of pure water
RO-100GPD 100GPDRO membrane About 1-2 years
RO-200GPD 200GPDRO membrane About 1-2 years
PTC-MBR-K Deionization purification column (imported resin) About 1000 liters of pure water/column
PTC-UPPR-K Ultrapure water column (imported resin) About 1000 liters of pure water/column
TF-(0.45+0.1)μm-S (0.45+0.1)μm imported PES terminal filter
UF-5000D MWCO5000DUF ultrafiltration component (original imported)
UV-(185nm&254nm)-10W-K Dual wavelength (185nm & 254nm) UV lamp assembly (imported)
LAMP-(185nm&254nm)-10W-K Dual wavelength (185 & 254nm) UV lamp (imported) About 9000 hours
UV-254-10W-K 254nmUV ultraviolet lamp assembly (imported lamp tube)
LAMP-254-10W-K 254nm UV lamp (imported) About 9000 hours

Reviews

There are no reviews yet.

Be the first to review “Smart-RO Water Purification System”

Your email address will not be published. Required fields are marked *

Quick Comparison

SettingsSmart-RO Water Purification System removeBistos BT- 740 Patient Monitor removeAtmosphere Protection Module removePERSONAL CO2/O2 MONITOR-SUB-ASPIDA removeCARBON MONOXIDE ATMOSPHERE MONITORING SYSTEM removeVENUS SOLO OEM SENSOR remove
NameSmart-RO Water Purification System removeBistos BT- 740 Patient Monitor removeAtmosphere Protection Module removePERSONAL CO2/O2 MONITOR-SUB-ASPIDA removeCARBON MONOXIDE ATMOSPHERE MONITORING SYSTEM removeVENUS SOLO OEM SENSOR remove
ImageBistos BT- 740 Patient Monitor
SKUSF1033560130126-1SF1033560059-9SF1033560130141-16SF1033560130141-13SF1033560130141-2SF1033560130141-15
Rating
Price

$0.00

$715.00

$0.00

$0.00

$0.00

$0.00

Stock
Availability
Add to cart

DescriptionShipped From Abroad An economical choice of primary pure water for daily laboratory cleaning, with an hourly water output of 15-30 liters, ion retention rate >97%, organic matter retention rate >99% (when MW >200 Daltons), particle and bacteria retention rate >99%, which can meet the water requirements for routine laboratory ware cleaning and can be used as the inlet water for ultrapure water systems, high-pressure steam sterilizers, environmental test chambers and other instruments.
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped from Abroad Bistos BT - 740 Patient Monitor: Bistos Patient Vital Signs Monitor, ECG, Resp., SpO2, NIBP, Temp., BT-740. The Bistos BT-740 is a multi-parameter patient monitor with an 8.4" TFT Color screen. The standard paramaters are ECG, respiratory, SpO2, NIBP and temperature. Additional options are EtCO2, IBP, Multi-gas, CO and Masimo SpO2. The BT-740 has a fanless design for quiet operation. Delivery & Availability: Typically 7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.Shipped From Abroad
Key Features
  • Flexible to meet your specific needs and ensures you meet current legislation
  • Measures up to 2 gasses with a choice of; O2 (oxygen), CO2 (carbon dioxide) and R134a (refrigerants). The APM will soon be able to measure VOCs (volatile organic compounds)
  • Uses MODBUS RTU communications protocol
  • Temperature compensated sensors with PressureSync technology
  • Fitted with 2 relays
  • Compatible with the Analox Distributed Atmosphere Monitoring solution (DAMS)
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad
Key features
  • It is the only portable monitor to be pressure corrected ensuring no false readings are given
  • The Sub Aspida is compact in size (127 x 44 x 90mm LxDxW)
  • The oxygen (O2) sensor can be calibrated on air, reducing costly gas requirements and making you self sufficient in the maintenance of the sensor
  • The carbon dioxide (CO2) sensor only needs calibrating every 12 months
  • OLED (Organic Light Emitting Diode) display
  • Pressure compensated CO2 & O2 sensors
  • Rechargeable battery-operated (NiMH)
  • Datalogging
  • Man-down alarm
  • Can offer continuous monitoring or spot checking
  • Audio, visual and vibration alarms
  • TWA (Time Weighted Average) Alarm
  • User maintainable
  • Can be worn on the belt or clipped to a panel
  • Pressure range of 700-1200mbara
  • Maintenance reminders as standard
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad

The COSAMS unit was designed specifically for use on submarines, most directly those that operate on diesel engines. Built to exacting military standards for performance, reliability and endurance, the Analox COSAMS uses proprietary Gas Filter Correlation (GFC) technology to specifically analyze the unique properties of CO.

The COSAMS (Carbon Monoxide Submarine Atmosphere Monitoring System) has been designed for use on submerged submarines to support life, where crew can be living and working for up to 90 days. Carbon monoxide can be generated on a submarine in several ways, from cooking and fire, to the incomplete combustion of diesel fuel and chlorate candles.
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad
Key Features
  • Single gas (user defined)
  • Backward compatible with ADC’s ‘Eclipse’
  • Linearised Output
  • Continuous status signal to check device health
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Content
Technical Parameters
Product Model Smart-RO15 Smart-RO30
Pure water output* 15L/Hour 30L/Hour
Instantaneous water output** Up to 2.0L/Min (when there is water in the water tank)
RO reverse osmosis water indicators
 Ion retention rate 97%-99% (when using new RO membrane)
 Organic matter retention rate >99%, when MW>200 Daltons
 Particle and bacteria retention >99%
 bacteria <0.01 cfu/ml (optional (0.45+0.1)μm imported PES terminal filter)
 Particles (>0.2μm) <1/ml (optional (0.45+0.1)μm imported PES terminal filter)
Raw water requirements Urban drinking tap water, water temperature 5-45℃, water pressure 1.0-4.0Kgf/ cm2
Instantaneous water output 2.0L/min (pressure water bucket required)
Water outlet 1: RO reverse osmosis water
Dimensions/weight Length × width × height: 41 × 22 × 42 cm / about 20 kg
Electrical requirements 100-240V, 50/60Hz
power 48W 72W
System Configuration Main unit (including 1 set of purification column) + 15L pressure water bucket + TDS/conductivity test pen + accessory bag
Consumables Information
Part Number/Model Product Name Service life/root (estimated)
PC-M-PP 5μmPP depth filter element About 2-6 months
PC-PP-ZK Zikang PP filter element About 2-6 months*
PC-AC-B-ZK Zikang activated carbon filter About 4-6 months*
PTC-AC-HZS1 Organic matter purification column About 6800 liters of pure water
RO-100GPD 100GPDRO membrane About 1-2 years
RO-200GPD 200GPDRO membrane About 1-2 years
PTC-MBR-K Deionization purification column (imported resin) About 1000 liters of pure water/column
PTC-UPPR-K Ultrapure water column (imported resin) About 1000 liters of pure water/column
TF-(0.45+0.1)μm-S (0.45+0.1)μm imported PES terminal filter -
UF-5000D MWCO5000DUF ultrafiltration component (original imported) -
UV-(185nm&254nm)-10W-K Dual wavelength (185nm & 254nm) UV lamp assembly (imported) -
LAMP-(185nm&254nm)-10W-K Dual wavelength (185 & 254nm) UV lamp (imported) About 9000 hours
UV-254-10W-K 254nmUV ultraviolet lamp assembly (imported lamp tube) -
LAMP-254-10W-K 254nm UV lamp (imported) About 9000 hours
Bistos BT - 740 Patient Monitor: Bistos Patient Vital Signs Monitor, ECG, Resp., SpO2, NIBP, Temp., BT-740. The Bistos BT-740 is a multi-parameter patient monitor with an 8.4" TFT Color screen. The standard paramaters are ECG, respiratory, SpO2, NIBP and temperature. Additional options are EtCO2, IBP, Multi-gas, CO and Masimo SpO2. The BT-740 has a fanless design for quiet operation. Features:
  • 8.4" TFT Color Screen - (Optional Touch Screen Upgrade)
  • Standard parameters are ECG, Resp., SpO2, NIBP, Temp.
  • Ultra-low power consumption
  • Quiet operation
  • High accuracy SpO2 reading
  • Data transfer or firmware upgrade via USB
  • 2 Years Manufacturer's Warranty
  Technical Specifications:
Model BT-740
Display 8.4" Color TFT Screen
ECG Lead type 3/5 Lead
Gain Selection x0.25, x0.5, x1, x2, x4, auto
Sweep speed (mm/s) 12.5, 25, 50
Bandwith:(Diagnostic Mode) 0.05-130Hz
Monitoring Mode 0.5-40Hz
Surgery Mode 1-25Hz
Strong Mode 5-20Hz
Heart Rate Range (bpm) Adult:15-300
Pediatric/neonate: 15-350
Respiration Method Trance-thoracic Impedance
Measurement Range 0-120rpm
Sweep Speed (mm/s) 6.25, 12.5, 25
SpO2 Measurement Range 0-100%
Accuracy (70-100%) Adult/Pediatric +/-2%
Neonate +/-3%
Accuracy (0-69%) Unspecified
Perfusion Index 0.05-20%
Pulse Rate Range (bpm) 25-250bpm
NIBP** Method Automatic (Oscillometric)
Operation Mode Manual/Auto/STAT
Parameter Systolic, Diastolic, Mean
Systolic Range (mmHg) Adult 40-270
Pediatric 40-200
Neonate 40-130
Diastolic Range (mmHg) Adult 10-210
Pediatric 10-160
Neonate 10-90
Mean Range (mmHg) Adult 20-230
Pediatric 20-175
Neonate 20-100
Temperature Range 0-50°C
Parameter T1, T2 and TD
IBP" Channel 2 Channel, 4 Channel
Range (mmHg) -50-400
Printer* Type Thermal dot array
Print Speed (mm/s) 12.5, 25, 50
Paper Size (mm) 50
CO2* Sidestream Masimo ISA / Bistos
Mainstream Masimo IRMA / Bistos
Multi-gas O2* Masimo ISA
SpO2 Masimo* Masimo SpO2
CO* Method Thermodilution
Range 0.2-20 L/min
Battery Type (Capacity) Li-ion (440mAh)
Run Time 6 hour
Charging Time 4 hour
Interface RJ45, USB, Nursing Call
Warranty 2 Years
 
Click Here To Download Catalogue
 
Descriptions
The Analox APM (Atmosphere Protection Module) is a configurable modular system which has the ability to monitor up to 2 gasses. This unique solution can be used as a stand alone atmosphere monitor or it can be integrated into existing PMS systems.  
Technical Specifications
System Specifications
Operating Temperature 0°C to +45°C +32°F to +113°F
Operating pressure 700 to 1300mBar
Humidity Range 0 to 95% RH
Power 24vDC (nominal) as standard
Communications MODBUS RTU
Relays 2 as standard
Calibration interval Before mission and / or every 3 months
Sensor Unit
Sensor type Range Danger
CO2 NDIR 0 to 5% / 0 to 30mBar Toxic
O2 (Depleted) Electrochemical 0 to 25% / 0 to 2500mBar Asphyxiation
O2 (enriched) Electrochemical 0 to 25% / 0 to 2500mBar Fire/explosion
R134a NDIR 0 to 1000ppm Asphyxiation
VOCs PID 0 to 20ppm Toxic
Click here to download Data Sheet
Download Pumped Detectors Technical Manual
Description
The Sub Aspida is a personal, portable monitor which is used to detect levels of carbon dioxide (CO2) and oxygen (O2) in pressurized environments.
CO2 monitoring & O2 monitoring with the Sub Aspida
Unlike industrial sensing monitors, the Sub Aspida was designed with pressure corrected sensors, giving you 100% confidence in your readings. The Sub Aspida has been upgraded to support those who work at high altitude. Pressure tested to 10,000 ft or 700 MB, the Sub Aspida will remain accurate and reliable when monitoring CO2 and O2 in the atmosphere, meaning you can concentrate on the job at hand!  
Technical Specification
SUB-ASPIDA
Key Features
  • Uses a GFC infra-red sensing technique ensuring the system is not sensitive to hydrogen or water vapor
  • Built-in auto-zero function ensures sensor stability
  • Real-time monitoring ensures rapid response to carbon monoxide (CO) issues as they occur
  • 90 days data-logging allows records to be stored and used should they ever be needed
  • Easy to maintain allowing you to be more self-sufficient whilst minimizing downtime
  • Designed specifically for the submarine environment so it is able to cope with the demands of the environment in terms of EMC, shock and temperature
 
Technical Specifications

Click here to download Data Sheet
Click here to download Manual
Description
The Venus Solo OEM sensor is a self-contained unit designed for integration into other manufacturers’ equipment and provides a measurement of gas concentration according to specific user requirements. These GFC (Gas Filter Correlation) sensors generate a signal proportional to the infrared absorption of the measured gas. Providing the gas concentration lies within the designed range of the sensor, the signal is periodically compared with a reference gas. Gas concentrations are indicated through the non-linearised analogue signal output. Gas connections to and from the sensor are via suitable fittings on the gas measuring cell. The Venus Solo OEM Series sensors electrical supply is designed to accept 24V DC (3amp max). Our Venus Solo OEM sensor uses GFC (Gas Filter Correlation) technology to give highly accurate gas measurements. The Venus Solo can be integrated into your own gas analyzer or management system and offers the user a 0-2.5v analogue output.

The sensor is currently available as either: Carbon dioxide (CO2), carbon monoxide (CO), nitrous oxide (N20), methane (CH4) or nitric oxide (NO). If your application requires a different gas, just let us know and we can customise it to your needs. The Venus Solo is used in Military applications to protect submariners from carbon monoxide (CO) exposure.  

Technical Specification
Venus Solo
WeightN/AN/AN/AN/AN/AN/A
DimensionsN/AN/AN/AN/AN/AN/A
Additional information
Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • Rating
  • Price
  • Description
Click outside to hide the comparison bar
Compare